Loading...
HomeMy WebLinkAboutFA PRODUCT INFO 4 - 20-00977 - Cal Ranch Interior - Remodel Fire Alarm Systems | FMM‑462 Family POPIT Addressable Manual Stations FMM‑462 Family POPIT Addressable Manual Stations www.boschsecurity.com u Single‑gang mounting u Latching alarm lever and key‑locked reset u Rugged die‑cast housing with 14 gauge (1.9 mm) plated steel back and corrosion‑resistant construction u Optional scored acrylic breakrod The FMM‑462 Addressable Manual Stations allow people evacuating a building to initiate an alarm and alert others still inside. The included POPIT module is addressed using on- board slide switches. It is then connected to the control panel’s data expansion loop. The POPIT is polled by the control panel and sends reports on any opens, shorts, or ground faults on the manual station's wiring. The addressable feature allows the agencies responding to alarm or trouble conditions to go to the point that initiated the alarm or trouble report. These low-profile manual stations are die cast with rounded edges to fit most design applications. All metallic components are painted or plated to inhibit corrosion. These manual stations conform to the Americans with Disabilities Act (ADA) standards. Functions Addressable Operation The POPIT connects to a two‑wire data expansion circuit from the control panel. Device address is set through slide switches on the POPIT Module, allowing programmable device identification by the control panel. Certifications and approvals ADA Complies with Americans with Disabilities Act ADA 4.28.3 NFPA Complies with National Fire Protection Association NFPA 72 Region Regulatory compliance/quality marks USA UL UNIU: Boxes, Non-Coded (UL38) CSFM see the Bosch website (www.boschse-curity.com) Installation/configuration notes WARNING This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to: www.P65Warnings.ca.gov. Compatibility Information The following table lists control panels compatible with the FMM‑462 and FMM-462-D manual stations: Control Panels Active products: D9412GV4, D7412GV4, D7212GV4***, D9412GV3, D7412GV3, and D7212GV3*** Inactive products*: D9412GV2, D7412GV2, and D7212GV2*** Legacy products**: D9412G, D7412G, D7212G***, D9412, D7412, and D7212*** D9124 D9112, D8112, and D7112 * Inactive products are no longer available for general sale ** Legacy products were investigated to comply only to UL864 8th edition *** Indicates products which are not UL listed for commercial fire applications Mounting Considerations The manual stations are for indoor use only. The manual station and the wiring from the control panel data expansion loop fit into a single‑gang back box for flush mounting. Use the larger FMM‑100BB‑R Back Box for surface mounting and to provide additional room for system wiring and the module. Technical specifications Electrical Current (alarm):0.8 mA Current (normal):0.5 mA Voltage (operating):7 VDC to 15 VDC supplied by the control panel Environmental Temperature (operating): +14°F to +120°F (-10°C to +49°C) Mechanical Activation Force:5 lb (2.3 kg) Alarm Response Time:1 sec (approximately) Dimensions (HxWxD):4.75 in. x 3.2 in. x 0.875 in. (12.1 cm x 8.1 cm x 2.2 cm) Material:Painted die‑cast metal, plated steel back and painted steel front Ordering information FMM-462 Manual station, single-action, red The single‑action manual station is UL Listed and meets Americans with Disabilities Act (ADA) requirements. It has a latching alarm lever with a key‑locked reset, a rugged die‑cast housing, and corrosion‑resistant construction. Order number FMM-462 FMM-462-D Manual station, double-action, red The double‑action manual station is UL Listed and meets Americans with Disabilities Act (ADA) requirements. It has a latching alarm lever with a key‑locked reset, a rugged die‑cast housing, and corrosion‑resistant construction. Order number FMM-462-D Accessories D102 Replacement key for D101 lock set The D102 is a replacement key for locks stamped with 1358. Order number D102 FMM-100BB-R Surface backbox, 4.75x3.25x2.25", red Red surface-mount metal back box Order number FMM-100BB-R FMM-100GR Break rods, scored acrylic, 12pcs Scored acrylic rods (12 per package) Order number FMM-100GR 2 | FMM‑462 Family POPIT Addressable Manual Stations 3 | FMM‑462 Family POPIT Addressable Manual Stations Represented by: Europe, Middle East, Africa:Germany:North America:Asia-Pacific: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 emea.securitysystems@bosch.com emea.boschsecurity.com Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@us.bosch.com www.boschsecurity.us Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia © Bosch Security Systems 2019 | Data subject to change without notice 2708443915 | en, V6, 06. Sep 2019