HomeMy WebLinkAboutFA POWER INFO - 20-00977 - Cal Ranch Interior - RemodelDescription AL602ULADA is an extremely cost effective voltage regulated remote NAC Power Extender. It may be connected to any 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and providing auxiliary power to support system accessories. AL602ULADA NAC Power Extender Altronix Corporation | 140 58th St | Brooklyn, NY 11220 USA phone: +1 718.567.8181 | fax: +1 718.567.9056 | email: info@altronix.com | www.altronix.com Rev. AL602ULADA - 03032020 Input Voltage 120VAC, 60Hz, 4A. Two (2) Class A or two (2) Class B inputs. Two (2) NC dry contact trigger inputs. Input Ratings (INP1 and INP2): 8-30VDC 6.5mA max from FACP. 12V 6.5mA, 24V 6.5mA from FACP. Output Voltage 24VDC power-limited outputs. Current 6.5A max. total alarm current. 2.5A max. current per output. Two (2) outputs may be paralleled for more power on an indicating circuit. Auxiliary 1A. Other Thermal and short circuit protection with auto reset. Filtered and regulated outputs. Programmable Supervised Indicating Circuit Outputs: Four (4) Class B, or Two (2) Class A, or One (1) Class A and Two (2) Class B. Back-up Battery (not included) Type Sealed lead acid or gel type. Failover Upon AC loss, instantaneous. Supervision AC Failure Form “C” contacts. Battery Form “C” contacts. Indicators (LED) AC Power (Green) Input voltage is present. DC Output (Red) Powered. Logic Board Output status. (Red and Green) Agency Listings UL UL864 (Control Units and Accessories for Fire Systems). MEA NYC Department of Buildings Approved. FM Factory Mutual Approved. CSFM California State Fire Marshal Approved. Special Features - 2-wire horn/strobe Sync mode allows audible notification appliances (horns) and visual notification appliances (strobes) to be silenced/deactivated at the same time. - Sync protocols include Potter/Amseco, Gentex®, System Sensor®, and CooperWheelock®. - Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit). - Compatible with 12VDC or 24VDC fire panels. - Output loop supervision steered to Input 1 or Input 2. - Signal circuit trouble memory (helps identify intermittent loop problems). - Common trouble input and output for external trouble signals tie-in. - Ground fault detection. Physical and Environmental Dimensions (H x W x D) 15.5” x 12” x 4.5” (393.7mm x 304.8mm x 114.3mm). Enclosure accommodates up to two (2) 12VDC/12AH batteries. Product Weight 9.6 lb. (4.35 kg). Shipping Weight 12.3 lb. (5.58 kg). Temperature Operating 0ºC to 49ºC (32ºF to 120ºF). Storage -20ºC to 70ºC (-4ºF to 158ºF). Relative Humidity 85% +/-5%. BTU/Hr. (approx.): 31 BTU/Hr. Specifications AL602ULADA