Loading...
HomeMy WebLinkAboutFA PRODUCT INFO - 20-00977 - Cal Ranch Interior - Remodel Intrusion Alarm Systems | D9127 Series POPIT Modules D9127 Series POPIT Modules www.boschsecurity.com u Provides point identification of initiating devices u Supervises wiring to devices for circuit integrity u Expands the number of points in the system u Compact size u Terminal connections for reliability The D9127 Series POPIT Modules includes the D9127T (with magnetic tamper switch) and the D9127U (without tamper). They are used with a D8125 or B299 Addressable Expansion Module when there is a need to expand a compatible control panel beyond its standard number of on-board initiating zones or points. Future system expansion is very economical as D9127 Series POPITs can be added anywhere along the two-wire data expansion loop from the D8125 or B299 modules. Both modules include proven technology that combines zone and point supervision with individual device addressing on one pair of wires. Screw terminals provide reliable connections for the data expansion loop and supervised sensor loop wiring. Install a 33 kΩ end-of-line resistor at the farthest point on the loop for proper supervision. The units are small and easily installed in standard outlet boxes, above false ceilings, closets, or other accessible locations. Certifications and approvals Region Regulatory compliance/quality marks USA UL UL UL 365 - Police Station Connected Bur-glar Alarm Units UL UL 464 - Standard for Audible Signal Ap-pliances UL UL 609 - Standard for Local BurglarAlarm Units and Systems UL UL 864 - Standard for Control Units andAccessories for Fire Alarm Systems(10th edition) UL UL 985 - Household Fire Warning Sys-tem Units (6th edition) UL UL 1023 - Household Burglar Alarm Sys-tem Units UL UL 1076 - Proprietary Burglar AlarmUnits and Systems UL UL 1610 - Central Station Burglar AlarmUnits UL UL 1635 - Standard for Digital AlarmCommunicator System Units Region Regulatory compliance/quality marks FM CSFM California State Fire Marshal FDNY-CoA 6059 [D9412GV3 & D7412GV3] FDNY-CoA 6286 D7412GV4 D9412GV4 NYC COA6286 2018-2021 FDNY-CoA 6196 Australia CTICK C-Tick Canada ULC CAN/ULC S304 - Standard for Signal Re-ceiving Center and Premise BurglarAlarm ULC S303 - Local Burglar Alarm Units andSystems ULC ULC 365 - Police Station Connected Bur-glar Alarm Units ULC APOU7.S1871 Proprietary Alarm UnitsCertified for Canada ULC ULC-ORD C1023 - Household BurglarAlarm System Units Installation/configuration notes Compatibility Information Control Panels All G Series control panels, D9412, D7412, D7212, D7212B1, D9112, D9112B1, D8112G1, D8112G2, and D9124 Modules D8125, B299 The D8125 or B299 POPEX Modules are required. The D9127 modules are wired in parallel on the D8125 or B299 data loops. Number of POPIT Modules per Control Panel D7212G, D7212GV2, D7212GV3 32 D9127 POPITs D7212B1 40 D9127 POPITs D7212, D7412, D7412G, D7412GV2, D7412GV3, D7412GV4 67 D9127 POPITs D9124 119 D9127 POPITs D9112B1 126 D9127 POPITs D9112, D9412, D9412G, D9412GV2, D9412GV3, D9412GV4 238 D9127 POPITs B8512G (D8125)67 D9127 POPITs B8512G (B299)91 D9127 POPITs B9512G (D8125)238 D9127 POPITs B9512G (B299)591 D9127 POPITs Wiring Considerations Wire Size Maximum Length of all Data Expansion Loops Combined 0.8 mm (22 AWG)549 m (1800 ft) 1.0 mm (20 AWG)881 m (2890 ft) 1.2 mm (18 AWG)1402 m (4600 ft) 1.5 mm (16 AWG)2231 m (7320 ft) 1.8 mm (14 AWG)3551 m (11650 ft) D8125 or B299 POPIT Loops Use one two-wire data expansion loop, or distribute the POPITs on multiple loops. The maximum lengths shown in the following table are for all data expansion loops combined connected to the same D8125 or B299 module. Setting DIP switches on the POPIT modules assigns them to point numbers. The switch setting on each POPIT assigns it a point number, regardless of its physical location. POPIT to Sensor Loops The number of detection devices each sensor loop can supervise is limited only by the resistance on the loop. Resistance on each sensor loop must be less than 100 Ω not including the end-of-line (EOL) resistor. Certain UL and National Fire Protection Association (NFPA) applications can limit the number of detection devices. Consult the appropriate UL or NFPA standards. Terminate each POPIT sensor loop with the 33 kΩ EOL resistor included with each POPIT. Use a twisted-pair wire (six twists per foot) in all POPIT installations for both the data expansion loop wiring and the POPIT sensor loops. Run wires away from AC sources to prevent AC induction. Technical specifications Environmental Considerations Relative humidity Up to 93% non-condensing Temperature (operating) 0°C to +60°C (+32°F to +140°F) For UL Certifcated Installations, 0°C to +50°C (+32°F to +122°F) Properties Color Off white Dimensions 8.1 cm x 3.8 cm x 2.4 cm (3.2 in. x 1.5 in. x 0.9 in.) Material UL Listed fire-resistant 2 | D9127 Series POPIT Modules Power Requirements Current draw 0.8 mA maximum Resistance Maximum increase in resistance on the POPIT loop is 1000 Ω. Maximum resistance between the D8125 or B299 modules and each POPIT is 90 Ω. Voltage (operating)12 VDC nominal Sensor Loop Resistance Maximum resistance on the sensor loop is 100 Ω. Response time 1 sec approximately Ordering information D9127T POPIT input module with tamper Includes a magnetic tamper switch. Order number D9127T D9127U POPIT input module without tamper No tamper switch. Order number D9127U D9127T-CHI POPIT input module with tamper Includes a magnetic tamper switch. Order number D9127T-CHI 3 | D9127 Series POPIT Modules Represented by: Europe, Middle East, Africa:Germany:North America:Asia-Pacific: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 emea.securitysystems@bosch.com emea.boschsecurity.com Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@us.bosch.com www.boschsecurity.us Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia © Bosch Security Systems 2020 | Data subject to change without notice 2538178443 | en, V15, 25. Jun 2020