Loading...
HomeMy WebLinkAboutSTAFF REVIEWS - Webster, Wade - 221 W 4th S - Singles Housing - Site PlanMemorandum To: Kurt Hibbard CC: John Millar From: Val Christensen Date: 11/5/2002 Re: Erickson Lot I have reviewed the apartment site plan located on the old Erickson Pontiac lot and have observed the following discrepancies or questions: 1. The 25' setback is missing on 3" West. In addition to the parking spaces located in the setback off 3rd West, parking spaces are also located in the setbacks off 4" South and 2"d West. 2. We were told that there would be 6 students in each living unit. If this is so, the amount of parking spaces falls well short of the 302 spaces required. 3. No handicapped spaces are shown. The Americans with Disabilities Act (ADA) requires 8 handicapped spaces in this size of a parking lot. Seven of these handicapped spaces are required to have 5' wide access aisles adjacent to them and one handicapped space is required to be "van accessible" wit a 9' wide access aisle. 4. The percent of compact spaces is higher than allowed by ordinance. 5. The South leg of the parking lot is too far from its snow removal area. 6. Some of the spaces do not have an aisle extension to allow for backing out of the space. 7. Utility services are not shown to the apartment building. 8. A storm water retention area is needed for this size of a parking lot. FILE MEM ORA NDUM To: Wade Webster, et. al. From: Kurt Hibbert, P & Z Administrator Date: November 5, 2002 Subject: Site Plan Deficiencies: Wade Webster Apartments Dear Wade, After a cursory review, the following items need to be addressed. You need to submit a new corrected site plan addressing the issues of the building department and the Planning and Zoning Department. I have attached the memo from Val in the building Department. I would encourage your engineer to contact Chris Huskinson at the fire department directly for the Fire Department Review. • The west side of the site plan bordering Yd East does not meet the engineering section for the sidewalk and curb and gutter. The side walk cannot be on the curb. The drawing incorrectly indicates the setback being 25 ft. from the curb line and not the property line. • The planning and Zoning Commission has required that all entrances to the development be properly lighted. • The parking ratio of compact spaces to full size spaces must be no less that a 60/40 Ratio. This parking requirement must be met for the site plan to be approved. Kurt Hibbert City of Rexburg / Planning and Zoning Administrator cc. File MEMO: TO: TO WHOM IT MAY CONCERN FROM: CHRIS HUSKINSON, FIRE INSPECTOR DATE: NOVEMBER 5, 2002 RE: WADE WEBSTER APARTMENTS (4 TI SOUTH & 2"n WEST) TO WHOM IT MAY CONCERN Upon review of the site plan drawings submitted the following items need to be addressed: 1. All areas adjacent to buildings not marked for parking shall be signed "No Parking Fire Lane" in addition to having the curb painted red and maintained. 2. ACCESS: 1997 Uniform Fire Code Section 902.2.1 states: "Fire apparatus access roads shall be provided... when any portion of the facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building." In this case the building is too long with no access from the south side to provide for safe and efficient firefighting operations. 3. ACCESS: 1997 Uniform Fire Code Section 902.2.2.4 states: "Dead-end fire apparatus access roads in excess of 150 feet in length shall be provided with approved provisions for the turning around of fire apparatus." In this case the access through the parking lot to the rear of the building on the western end exceeds the allowable distance by approximately 50 feet. 4. WATER SUPPLY: The drawing shows only one new hydrant and no existing fire hydrants. Additional hydrants are required, and as noted, the building shall be fully sprinklered including the attic spaces. If there are any questions please feel free to contact me. Z4 -- Chris Chris Huskinson Fire Inspector