Loading...
HomeMy WebLinkAboutCOMCHECK - 06-00620 - Galbraith Eye Clinic - Tenant FinishNMMDEC-21-2006 12:44 PM DC ELECTRIC INC 208 552 4622 •t! ar Lighting Compliance Certificate 2004 I ECC Report Date: 12/21/06 Data filename: Untltled.ock 0600620 P.01 Galbraith Eye Clinic Suite 44 Section 1: Project Information Project Th1w Construction Site: Owner/Agent: 10 Shawn Galbraith Eye Cllnlc Tra)o Plaza -Suite 1 Rexburg, ID Section 2: General Information Building Use Description by: Pro)ect Type: New Construction Building Tyge Flaor Artie Medical and Clinical Care 1900 Section 3: Requirements Checklist Interior Lighting: 1. Total actual weft must be lobe than or equal to total allowed weft. Allowed Watts Actusl Weirs complies 2280 2220 YES Daslg nor/Contrecto r: Dale Clements PO Box 3118 Idaho Falls, ID 83404 208-832.1911 Exterior Lighting: Q 2. Efficacy greater than 46 lumara 1. Exceptions: Speclellzed lighting highlighting features of historic buildings; 9lgnage; safety, or Security lighting; low-vollege landscape lighting. Controls, switching, and Wlring: ❑ 3. Independent controls for each space (awhch%occupency sensor). Exceptions: Areas designated as security or emergency areas that must be continuously Illuminated. Lighting In stairways or corlldom that are elements of the means of agrees. L) 4. Master switch at entry to holellmotel guest room_ O 6. Individual dwelling unite separately metered. 6. Each space provided with a manual contralto provide uniform light reduction by at least 60%. Exceptbns: Only one luminelre In apace; An occupant-saneing device controls the area; The area In a corridor, storeroom, restroom, public lobby or guest room; Areas that use leas than 0.6 Wettnraq.ft. 7, Automatio lighting shutoff Control In buildings larger than 6.000 sq.r, O 8. Photocell/astronomical time switch on exterior Ilghte. D 1�GE9VE DEC 2 1 2006 110 CITY OF REXBURG Page 1 of 3 DEC-21-2006 12:44 PM DC ELECTRIC INC 208 552 4622 P. 02 COMcheck Software Version 3.3.1 Lighting Application Worksheet 2004 IECC Report Date: Date filename: Unfitled.eck Section 1: Allowed Lighting Power Calculation A B C 0 Floor Am Allowed Allowed Waft Won@ 1 M MedIcal and Clinical Care 1900 1.2 2280 Total Alk3Am3d Watts = 2280 Section 2: Actual Lighting Power Calculation A a C 0 E FbdUre 10 : Description I Lamp I Wattage Par Lamp I Ballast Lamps/ 0 of Fixture (C X 0) Fbdure 1hdurez Waft. Linear Fluorescent 1: 48' To 32W / Electronic 4 16 128 1920 Incandescent 1: Incandescent 75W 1 2 ISO 300 Total Actual Wift n 2220 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts Is grater then or equal to zem, the bulldlng Compiles. Total Allowed Watts m 2260 Total Actual Watts = 2220 Project coffwllance M 60 Mg - Page 3 of 3 DEC-21-2006 12:45 PM DC ELECTRIC INC 208 552 4622 P.03 Ex 1 aePt MM Ughting Intended for 24 hour use. 0 8. Tandem wired cn04emp artd #900-IaMp ballasted tuminalres (No single -lamp ballasts). ExoeRtlons: Eiectwic high-ftquency ballaste, Luminaires on emergency ctroults or with no available palr. Section 4: Compliance Statement ComPllanOO Stetdment: The proposed lighting design represented In this document Is conalstent with the building plans, spectRcatlons and other calculation submitted with this permit appilcation. The proposed lighting system has been designed to meet the 2004 IECC, Chapter 0, requirements In COMaheck Vefaion 3.3.1 and to comply with the mand ry requirements in the Requirements Checklist. Name -Title c -.1! - O h StgnatUre Date Page 2 of 3 ti Lighting Compliance Certificate 2001 IECC Permit #06 00348 Dc ( Professional Bldg for Tern.Bagley Trejo Professional Plaza Lot # I Block # I COMcheck-EZ Software Version 2.4 Release 2c Data filename: C:\Program Files\Check\COMcheck-EZ\Terry Bagley Eye Clinie.cck Section 1: Project Information Project Name: Designer/Contractor: Telephone: Document Author: Telephone: Date: Bagley Eye Center Suite 1 Rexburg,ldaho aC E12e4-RIe ZnC. 5S3-1 Cl It Section 2: General Information Building Use Description by: Whole Building Type Building Type Floor Area Medical and Clinical Care 1900 Project Description (check one): New Construction _ Addition _ Alteration _ Unconditioned Shell (File Affidavit) Section 3: Requirements Checklist Bldg. Dept. Use [ ] Interior Lighting 1. Total actual watts must be less than or equal to total allowed watts Allowed Watts Actual Watts Complies(Y/N) 3040 3010 YES Exterior Lighting [ ] 2. Efficacy greater than 45 lumens/W Exceptions: Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low -voltage landscape lighting. Controls, Switching, and Wiring [ ] 3. Independent controls for each space (switch/occupancy sensor). Exception: Areas that must be continuously lighted. [ ] 4. Master switch at entry to hotel/motel guest room. [ ] 5. Two switches or dimmer in each space to provide uniform light reduction capability. Exceptions: Only one luminaire in space; An occupant -sensing device controls the area; The area is a corridor, storage, restroom, or lobby; Areas that must be cont Areas greater than 250 sq.ft. py E NOV 1 6 2006 CITY OF REXBURG Lighting Application Worksheet 2001 IECC COMcheck EZ Software Version 2.4 Release 2c Section 1: Allowed Lighting Power Calculation A B C D Total Floor Allowed Allowed Area Watts Watts Building_Tne (ft2) (watts/ft2) (B x C) Medical and Clinical Care 1900 1.6 3040 Section 2: Actual Lighting Power Calculation A B Fixture Fixture Description / ID Lamp Description / Wattage Per Lamp / Ballast 1 48" T8 32W / Electronic 2 Incandescent 75W Total Allowed Watts = 3040 C D E F Lamps/ # of Fixture Fixture Fixtures Watt. x E 4 20 128 2560 1 6 75 450 Total Actual Watts = 3010 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 3040 Total Actual Watts = 3010 Project Compliance = 30 Lighting PASSES: Design 1% better than code w [ ] 6. Photocell/astronomical time switch on exterior lights. j Exceptions: Areas requiring lighting during daylight hours [ ] ( 7. Tandem wired one -lamp and three -lamp ballasted luminaires. Exceptions: Electronic high -frequency ballasts; Luminaires not on same switch Section 4: Compliance Statement The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2001 IECC, Chapter 8, requirements in COMcheck EZ Version 2.4 Release 2c and to comply with the mandatory requirements in the Requirements ecklist. D-oz 4'o'z I / /A � cipal Lighting Designer -Name Signature Date, 6ALI, dexxcl�5 COMcheck Software Version 3.3.0 Lighting Compliance Certificate 2003 IECC Report Date: 12/21/06 Data filename: Untitied.cck Section 1: Project Information Project Title: Bagley Eye Center Construction Site: Owner/Agent: Trejo Professional Plaza Suite 1 Terry Bagley Rexburg, ID 83440 Rexburg, ID 83440 Permit No. 06 00348 Permit Date: November 1, 2006 Section 2: General Information Building Use Description by: Project Type: New Construction Building Type Floor Area Medical and Clinical Care 1900 Section 3: Requirements Checklist Interior Lighting: 1. Total actual watts must be less than or equal to total allowed wafts. Allowed Watts Actual Watts Complies 2280 3010 NO 2. Exit signs 5 Watts or less per side. Designer/Contractor. DC Electric 208-552-1911 Exterior Lighting: O 3. Efficacy greater than 45 lumenslW. Exceptions: Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low -voltage landscape lighting. Controls, Switching, and Wiring: ❑ 4. Independent controls for each space (switch/occupancy sensor). Exceptions: Areas designated as security or emergency areas that must be continuously illuminated. Lighting in stairways or corridors that are elements of the means of egress. 5. Master switch at entry to hotel motel guest room. 6. Individual dwelling units separately metered. El 7. Each space provided with a manual control to provide uniform light reduction by at least 50%. Exceptions: Only one luminaire in space; An occupant -sensing device controls the area; The area is a corridor, storeroom, restroom, public lobby or guest room; Areas that use less than 0.6 WatLs/sq.ft. ❑ 8. Automatic lighting shutoff control In buildings larger than 5,000 sq.ft. Page 1 of 3 0 9. Photocell/astronomical time on exterior lights. Exceptions: Lighting Intended for 24 hour use. 10. Tandem wined one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts). Exceptions: Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair. Page 2 of 3 COMcheck Software Version 3.3.0 Lighting Application Worksheet 2003 IECC Report Date: Data filename: Untitled.cck Section 1: Allowed Lighting Power Calculation A B C D Floor Area Allowed Allowed Watts Watts /ft2 Medical and Clinical Care 1900 1.2 2280 Total Allowed Watts = 2280 Section 2: Actual Lighting Power Calculation A B c D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Waft. Linear Fluorescent 1: 1: 48" T8 32W / Electronic 4 20 128 2560 Incandescent 1: 2: Incandescent 75W 1 6 75 450 Total Actual Watts = 3010 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 2280 Total Actual Watts = 3010 Project Compliance = -730 Page 3 of 3