HomeMy WebLinkAboutRESCHECK - 06-00598 - 556 Woodbridge St - New SFR✓ - - "'kill1w
0600598
556 Woodbridge St-TDG
Q1REScheck Software Version 3.7.3
Compliance Certificate
Project Titie: Stonebridge Lot #2
Report Date: 09/05/06
Data filename: C:\Documents and Settings\Swtt\Desktop\TDG\Rescheck Stonebridge Lot 2.rck
Energy Code: 2003 IECC
Location: Rexburg, Idaho
Construction Type: Single Family
Glazing Area Percentage: 18%
Heating Degree Days: 8693
Construction Site: Owner/Agent: Designer/Contractor:
Rexburg, ID 83440 The Development Group
Rexburg, ID 83440
Ceiling 1: Cathedral Ceiling (no attic): 1545 40.0 0.0 40
Wall 1: Wood Frame, 16" o.c.: 207 23.0 0.0 9
Window 1: Vinyl Frame:Double Pane with Low-E: 6 0.350 2
Window 2: Vinyl Frame:Double Pane with Low-E: 6 0.350 2
Window 3: Vinyl Frame:Double Pane with Low-E: 15 0.350 5
Window 4: Vinyl Frame:Double Pane with Low-E: 15 0.350 5
Wall 2: Wood Frame, 16" o.c.: 495 23.0 0.0 22
Window 5: Vinyl Frame:Double Pane with Low-E: 10 0.350 4
Window 6: Vinyl Frame:Double Pane with Low-E: 10 0.350 4
Window 7: Vinyl Frame:Double Pane with Low-E: 15 0.350 5
Window 8: Vinyl Frame:Double Pane with Low-E: 15 0.350 5
Window 9: Vinyl Frame:Double Pane with Low-E: 15 0.350 5
Window 10: Vinyl Frame:Double Pane with Low-E: 15 0.350 5
Door 1: Glass: 21 0.350 7
Wall 3: Wood Frame, 16" o.c.: 306 23.0 0.0 16
Window 11: Vinyl Frame:Double Pane with Low-E: 8 0.350 3
Window 12: Vinyl Frame:Double Pane with Low-E: 8 0.350 3
Wall 4: Wood Frame. 16" o.c.: 108 23.0 0.0 4
Window 13: Vinyl Frame: Double Pane with Low-E: 15 0.350 5
Window 14: Vinyl Frame:Double Pane with Low-E: 15 0.350 5
Wall 5: Wood Frame, 16" o.c.: 36 23.0 0.0 2
Wall 6: Wood Frame, 16" o.c.: 108 23.0 0.0 5
Window 15: Vinyl Frame:Double Pane with Low-E: 12 0.350 4
Window 16: Vinyl Frame:Double Pane with Low-E: 12 0.350 4
Wall 7: Wood Frame, 16" o.c.: 117 23.0 0.0 6
Wall 8: Wood Frame. 16" o.c.: 63 23.0 0.0 1
Window 17: Vinyl Frame:Double Pane with Low-E: 10 0.350 4
Window 18: Vinyl Frame:Double Pane with Low-E: 10 0.350 4
Door 2: Solid: 21 0.350 7
Wall 9: Wood Frame, 16" o.c.: 225 23.0 0.0 11
Door 3: Solid: 21 0.350 7
Stonebridge Lot #2 Page 1 of 2
Basement Wall 1: Solid Concrete or Masonry:
Window 19: Vinyl Frame:Double Pane with Low-E:
Basement Wall 2: Solid Concrete or Masonry:
Window 20: Vinyl Frame:Double Pane with Low-E:
Window 21: Vinyl Frame:Double Pane with Low-E:
Basement Wall 3: Solid Concrete or Masonry:
Window 22: Vinyl Frame:Double Pane with Low-E:
Window 23: Vinyl Frame:Double Pane with Low-E:
Basement Wall 4: Solid Concrete or Masonry:
Basement W211 5: Solid Concrete or Masonry:
Basement Wall 6: Solid Concrete or Masonry:
Basement Wall 7: Solid Concrete or Masonry:
Basement Wall 8: Solid Concrete or Masonry:
Fumace 1: Forced Hot Air: 92 AFUE
207
13.0
0.0
11
15
0.350
5
495
13.0
0.0
26
16
0.350
6
16
0.350
6
288
13.0
0.0
15
16
0.350
6
16
0.350
6
108
13.0
0.0
6
36
13.0
0.0
2
108
13.0
0.0
6
117
13.0
0.0
7
288
13.0
0.0
16
Compliance Statement. The proposed 1.Iding design described here is consistent with the building plans, specifications, and other
calculation s submitted vi the perm application. The proposed building has been designed to meet the 20031ECC requirements in
RESche k Versi o0 .3 nd to corrly with the mandatory requirements listed in the REScheck Inspection Checklist.
Kit
Builder/Desig Company Name Date
Stonebridge Lot #2 Page 2 of 2
'►✓ %0�
REScheck Software Version 3.7.3
Inspection Checklist
Date: 09/05/06
Ceilings:
] Ceiling 1: Cathedral Ceiling (no attic), R-40.0 cavity insulation
Comments:
Above -Grade Walls:
] Wall 1: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
] Wall 2: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
] Wall 3: Wood Frame, 16" o.c.. R-23.0 cavity insulation
Comments:
] Wall 4: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
] Wall 5: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
] Wall 6: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
] Wall 7: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
] Wall 8: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
] Wall 9: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
Basement Walls:
] Basement Wall 1: Solid Concrete or Masonry, 9.0' ht18.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
] Basement Wall 2: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
] Basement Wall 3: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
] Basement Wall 4: Solid Concrete or Masonry, 9.0' ht18.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
] Basement Wall 5: Solid Concrete or Masonry, 9.0' ht18.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
] Basement Wall 6: Solid Concrete or Masonry, 9.0' hV8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
] Basement Wall 7: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
] Basement Wall 8: Solid Concrete or Masonry, 9.0' ht18.0' bg/9.0' insul, R-13.0 cavity Insulation
Comments:
Windows:
] Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0,350
For windows without labeled U-factors, describe features:
#Panes - Frame Type Thermal Break? -Yes _ No
Comments:
Page 1 of 5
] Window 2: Vinyl Frame:Double Pane with Low-E. U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 3: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 4: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 5: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 6: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 7: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 8: Vinyl Frame:Double Pane with Low-E, U-factor. 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 9: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 10: Vinyl Frame:Double Pane with Low-E, U-factor. 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 11: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 12: Vinyl Frame:Double Pane with Low-E. U-factor. 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
Window 13: Vinyl Frame:Double Pane with Low-E, U-factor. 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
Window 14: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
Window 15: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
Page 2 of 5
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 16: Vinyl Frame:Double Pane with Low-E. U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 17: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 18: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 19: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 20: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 21: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
Window 22: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
] Window 23: Vinyl Frame:Double Pane with Low-E, U-factor. 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
Doors:
] Door 1: Glass, U-factor. 0.350
Comments:
Door 2: Solid, U-factor: 0.350
Comments:
] Door 3: Solid, U-factor: 0.350
Comments:
Heating and Cooling Equipment:
] Furnace 1: Forced Hot Air: 92 AFUE or higher
Make and Model Number:
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.
] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation.
Skylights:
] Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19.
Page 3 of 5
Vapor Retarder:
] Required on the warm -in -winter side of all non -vented framed ceilings, walls, and floors.
Materials Identification:
] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
] Materials and equipment must be identified so that compliance can be determined.
] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided.
] Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or
specifications.
Duct Insulation:
] Supply ducts in unconditioned attics or outside the building must be insulated to R-11.
] Return ducts in unconditioned attics or outside the building must be insulated to R-6.
] Supply ducts in unconditioned spaces must be insulated to R-11.
] Return ducts in unconditioned spaces (except basements) must be insulated to R-2.
] Where exterior walls are used as plenums, the wall must be insulated to R-11.
] Insulation is not required on return ducts in basements.
Duct Construction:
] Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened.
] All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500
Pa).
] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the
heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
] HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
2.
Page 4 of 5
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Heated Water
Non-Circulating-Runouts
Circulating Mains and Runouts
Temperature (OF)
Up to 1"
Up to 1.25"
1.5" to 2.0" Over 2"
170-180
0.5
1.0
1.5 2.0
140-169
0.5
0.5
1.0 1.5
100-139
0.5
0.5
0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Fluid Temp.
Insulation Thickness in Inches by Pipe Sizes
Piping System Types
Range(OF)
2" Runouts 1" and Less
1.25" to 2.0"
2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
106-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)
Page 5 of 5