HomeMy WebLinkAboutPLANS - 21-00387 - 154 Elm Ave - Solar PanelsCOVER SHEET PV-1 PV-1 COVER PV-2 SITE PLAN PV-3 ARRAY LAYOUT PV-4 STRUCTURAL ELEVATION PV-5 SINGLE LINE DIAGRAM PV-6 MSP PHOTOS PV-7 ELECTRICAL NOTES PV-8 SIGNAGE PV-9 SITE DIRECTORY ATTACHMENTS: +MODULE SPEC SHEET +INVERTER SPEC SHEET +RACKING SPEC SHEET +ENGINEERING LETTER NORTH SHEET INDEX CONTRACTOR SIGNATURE DRAWING TYPE PROJECT ADDRESS RYKER PARKINSON 154 ELM AVE REXBURG, ID 83440 DATE REVISION # SHEET NUMBER 5/26/2021HORIZON PWR 237 N 2ND ST, SUITE 202 REXBURG, ID 83440 888-468-7180 LICENSE #: 051666 VICINITY MAP: (NOT TO SCALE) PROJECT NARRATIVE: SYSTEM DESCRIPTION: 1.3.75 KW DC GRID-TIED SOLAR PHOTOVOLTAIC SYSTEM 2.(2) ARRAYS ON A SINGLE STORY RESIDENCE WITH A TRAPEZOIDAL SEAM METAL ROOF. 3.(1) INVERTER LOCATED ADJACENT MAIN SERVICE PANEL AND UTILITY METER. 4.CONNECT SYSTEM TO MAIN SERVICE PANEL LOCATED ON EXTERIOR OF RESIDENCE WITH NEW PV BREAKER. AC DISCONNECT LOCATED ADJACENT TO MSP. 5.RUN EMT ON EXTERIOR OF THE RESIDENCE, ON ROOF, AND UNDER EAVES. 6.ROOF STRUCTURE: 2"X6" TRUSSES AT 24" O.C. 7.FIRE RATING: JINKO SOLAR TYPE-1 MODULE WITH IRONRIDGE CLASS-A RACKING SYSTEM EQUIPMENT LIST: (10) 375W JINKO SOLAR EAGLE 66TR G4 MODULES: JKM375M-6RL3-B (1) SOLAREDGE HD-WAVE 3.0KW INVERTERS: SE3000H-US (10) SOLAR EDGE POWER OPTIMIZERS: P401 (1) SQUARE-D DU221RB 30A NON-FUSED AC DISCONNECT (14) IRONRIDGE UFO CLAMPS (12) IRONRIDGE CAMO END CLAMPS (26) S-5! PROTEA-BRACKET FOOTINGS (~70 FT) IRONRIDGE XR100 RACKING (1) 20 AMP 2-POLE PV BREAKER (AT MSP) DESIGN CRITERIA: EXPOSURE: B ASCE 7-16 RISK II 3 SEC WIND GUST = 105 MPH GROUND SNOW LOAD = 51 PSF REFERENCE CODES AND CONSTRUCTION NOTES: THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES: 2017 NATIONAL ELECTRICAL CODE (NEC), 2018 INTERNATIONAL BUILDING CODE (IBC), MANUFACTURER AND PV INDUSTRY STANDARDS, AND ALL STATE AND JURISDICTION BY-LAWS AND ORDINANCES. PROJECT SHALL BE INSTALLED BY A LICENSED CONTRACTOR. FRONT OF HOUSE: PV-2 NORTH CONTRACTOR SIGNATURE DRAWING TYPE PROJECT ADDRESS RYKER PARKINSON 154 ELM AVE REXBURG, ID 83440 DATE REVISION # SHEET NUMBER 5/26/2021HORIZON PWR 237 N 2ND ST, SUITE 202 REXBURG, ID 83440 888-468-7180 LICENSE #: 051666 SITE PLAN SCALE: 1" = 20'1 ARRAY INFORMATION ARRAY # OF MODULES PITCH MAGNETIC ORIENTATION TRUE ORIENTATION AR-01 8 19°102°90° AR-02 2 19°192°180° SITE PLAN NOTES: ·SMOKE / CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INSTALLED AND IN WORKING CONDITION. ·NOTIFY UTILITY COMPANY BEFORE ACTIVATION OF PV SYSTEM. (N) AC DISCONNECT SWITCH APN #: RPR0POW0063250 YEAR BUILT: 1966 FIRE OFFSETS: 36" FROM RIDGE 36" FROM EDGE 36" SHARED FOR HIPS AND VALLEYS (N) SOLAREDGE 3.0K INVERTER W/ INTEGRATED DC DISCONNECT (E) MAIN RESIDENCE (E) GARAGE (N) PV ARRAY AR-01 (E) DRIVEWAY MAIN SERVICE PANEL AND UTILITY METER (POINT OF SOLAR CONNECTION) (E) PROPERTY LINE ELM AVE(N) PV ARRAY AR-02 125'94'125'94' 73.0" 40.5"1.37" JINKO SOLAR EAGLE 66TR G4 JKM375M-6RL3-B 375W SPECS: L: 73.05" W: 40.51" D: 1.37" 46.96 LBS. CONTRACTOR SIGNATURE DRAWING TYPE PROJECT ADDRESS RYKER PARKINSON 154 ELM AVE REXBURG, ID 83440 DATE REVISION # SHEET NUMBER 5/26/2021HORIZON PWR 237 N 2ND ST, SUITE 202 REXBURG, ID 83440 888-468-7180 LICENSE #: 051666 ARRAY LAYOUT SCALE: 1/8" = 1'1 NORTH CONSTRUCTION NOTES ·ROOF PITCH: 19° ·ROOF CLADDING: TRAPEZOIDAL SEAM METAL ROOF ·ROOF STRUCTURE: 2"X6" TRUSSES AT 24" O.C. ·MOUNTS ARE ON GRID SPACING, OCCURRING AT RAFTERS. ·VERIFY RAFTER LOCATIONS IN FIELD. ·REFER TO MODULE AND RACKING MFR'S INSTALL MANUALS. ·MAX SPAN BETWEEN MOUNTS: 50" O.C. ·APPROX (26) MOUNTS TOTAL ·PLUMBING AND MECHANICAL VENTS SHALL NOT BE COVERED BY SOLAR MODULES. ·ALL FASTENERS STAINLESS STEEL U.O.N. ARRAY LAYOUT (N) JUNCTION BOX (TYP) (UNDER ARRAY) ADDITIONAL NOTES: ·FINAL LOCATION OF ALL CONDUIT AND JUNCTION BOXES TO BE DETERMINED AT TIME OF INSTALLATION. ·CONDUIT TO BE PAINTED TO MATCH EXTERIOR OF RESIDENCE WHERE APPLICABLE AND IS TO BE SUPPORTED EVERY 10' MAX. ·30" WIDE X 36" DEEP WORKING SPACE CLEARANCES REQUIRED ABOUT ALL ELECTRICAL EQUIPMENT. ·STAGGER PENETRATIONS TO EVENLY DISTRIBUTE LOAD ACROSS ALL TRUSSES UNDER ARRAY. ·ALL DIMENSIONS ARE APPROXIMATIONS. PV-3 (N) IRONRIDGE XR100 RAILING (N) CONDUIT RUN: 3/4" EMT (ON ROOF, UNDER EAVES) (N) CONDUIT RUN: 3/4" EMT MODULE DETAIL SCALE: 3/8" = 1'2 1 PV4 (N) ROOF MOUNTS EVERY 50" O.C. MAX (N) AC DISCONNECT SWITCH (N) SOLAREDGE 3.0K INVERTER W/ INTEGRATED DC DISCONNECT (E) 4X VENTS MAIN SERVICE PANEL AND UTILITY METER (POINT OF SOLAR CONNECTION) RIDGE 19° (N) PV ARRAY AR-01 (166.4 SQ. FT.) (E) PEAK OF SEAMS EVERY 10" O.C. (N) PV ARRAY AR-02 (41.6 SQ. FT.)RIDGE19°(E) CHIMNEY 3'3' 3'3'4'-2" MAX PV-4 CONTRACTOR SIGNATURE DRAWING TYPE PROJECT ADDRESS RYKER PARKINSON 154 ELM AVE REXBURG, ID 83440 DATE REVISION # SHEET NUMBER 5/26/2021HORIZON PWR 237 N 2ND ST, SUITE 202 REXBURG, ID 83440 888-468-7180 LICENSE #: 051666 ROOF ELEVATION SCALE: 1/2" = 1'1 SOLAR MODULE STRUCTURAL ELEVATION LOAD INFORMATION QUANTITY WEIGHT / UNIT TOTAL WEIGHT MODULES 10 46.96 LBS 469.6 LBS OPTIMIZERS 10 1.43 LBS 14.3 LBS FOOTINGS 26 0.757 LBS/FT 19.7 LBS RAILING 70 FT 0.685 LBS/FT 48.0 LBS RAIL SPLICES 0 0.40 LBS 0.0 LBS MID CLAMPS 14 0.081 LBS 1.1 LBS END CLAMPS 12 0.17 LBS 2.0 LBS WEIGHT OF ARRAY 554.7 LBS AREA 208.0 SQFT WEIGHT PER AREA 2.67 LBS / SQFT WEIGHT PER PENETRTION 21.3 LBS / PEN. ASSUMPTIONS: EXPOSURE: B ASCE 7-16 RISK II 3 SEC WIND GUST = 105 MPH GROUND SNOW LOAD = 51 PSF STRUCTURAL EVALUATION: DEAD LOAD: 2.67 PSF < 4.0 PSF OK 21.3 LBS/PEN < 40 LBS/PEN OK FOOTING SPACING: 48" < 59"OK (SEE IRONRIDGE SPAN TABLE) FRONT VIEW FOOTING DETAIL SCALE: 3/4" = 1'2 SOLAR MODULE IRONRIDGE UFO CLAMP IRONRIDGE XR100 RAILING IRONRIDGE UFO CLAMP IRONRIDGE XR100 RAILING 2"X6" TRUSS @ 24" O.C. 1/2" PLYWOOD SHEATHING 2"X6" TRUSSES @ 24" OC RIDGE BOARD TOP PLATE LOAD BEARING WALL TRAPEZOIDAL SEAM METAL ROOF @ 10" O.C. @ 19° PITCH 8MM HEX SCREW, 1" IN LENGTH (4 PER BRACKET) FACTORY APPLIED SEALANT S-5! PROTEA-BRACKET FOOTING 3'4"19°TRAPEZOIDAL SEAM METAL ROOF @ 19° PITCH 8MM HEX SCREW, 1" IN LENGTH (4 PER BRACKET) FACTORY APPLIED SEALANT 2' 10" 4'-2" MAX AC OUT DC IN NOTES: ·CONDUTORS ON ROOF MUST BE SUNLIGHT RESISTANT, 90°C RATED AND SUITABLE FOR WET LOCATIONS. ·SEE RACKING SPEC SHEETS FOR RACKING EQUIPMENT GROUNDING METHOD. ·ALL GROUNDING CONDUCTORS MUST BE PROTECTED FROM DAMAGE IF NOT INSTALLED IN CONDUIT. ·ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF. ·ALL DEVICES USED FOR BONDING FRAMES OF MODULES OR OTHER EQUIPMENT TO THE GROUNDING SYSTEM MUST BE LISTED AND IDENTIFIED FOR THE PURPOSE. ·SOLAREDGE OPTIMIZERS ARE TO BE BONDED TO RACKING BY USING EITHER AN OPTIMIZER ATTACHMENT KIT OR A SOLAREDGE GROUNDING PLATE. (SEE SPEC SHEETS). ·ALL CONDUCTORS LOCATED WITHIN ATTIC OR ENTERING THE STRUCTURE SHALL BY INSTALLED AT LEAST 18" BELOW THE ROOF DECK. NOTE: INTEGRATED DC DISCONNECT IS INSTALLED WITH RAPID SHUTDOWN DEVICE BY MANUFACTURER IN COMPLIANCE WITH NEC 690.12. CONDUCTORS EXPOSED TO FREE AIR (2) #10 AWG PV-WIRE CONDUCTORS (1) #6 AWG BARE COPPER GROUND AR-01 (8) 375W JINKO EAGLE 66TR G4 MODULES: JKM375M-6RL3-B IN (1) PARTIAL STRING OF (10) MODULES AT (19°) PITCH AND (90°) ORIENTATION (8) SOLAREDGE: P401 DC OPTIMIZERS SOLADECK 0799 SERIES UL50 TYPE 3R JUNCTION BOX SOLAREDGE TECHNOLOGIES: HD-WAVE SE3000H-US (240V) GRID TIED 2-POLE 3000 WATT INVERTER AC MAX OUTPUT CURRENT OF 12.5A UTILITY INTERACTIVE INVERTER W/ INTEGRATED DC DISCONNECT 8.5A MAX, 480VDC MAX (ADJACENT TO UTILITY METER) NOTE: SOLADECK JUNCTION BOX IS UL50 TYPE 3R AND NEMA TYPE 3R RATED, CONFORMING TO UL 1741. SOLADECK PRODUCTS ARE LISTED BY ETL TO UL STANDARDS (SEE SPEC SHEETS). NOTE THAT 8*3/4" = 6" < 8", SO OK TO USE. SQUARE-D DU221RB SINGLE PHASE, 30AMP, 240V, NON-FUSED, NEMA 3R ENCLOSURE (OR EQUIV.) AC DISCONNECT (WITHIN 3' OF UTILITY METER) 120/240 VAC SERVICE IDAHO POWER #: 47-604-146 EXISTING 100A MSP W/ 100A MAIN BREAKER. INSTALL NEW 20A 2-POLE PV BREAKER AT END OF BUS BAR. N G FACILITY GROUND UTILITY METER (E) 100A 2-POLE MAIN BREAKER (N) 20A 2-POLE PV BREAKER 3/4" EMT OR EQUIVALENT (2) #10 AWG THWN-2 CONDUCTORS (1) #10 AWG THWN-2 NEUTRAL (1) #8 AWG THWN-2 GROUND 3/4" EMT OR EQUIVALENT (ON ROOF, UNDER EAVES) (2) #10 AWG THWN-2 CONDUCTORS (1) #10 AWG THWN-2 GROUND CONDUCTORS EXPOSED TO FREE AIR (2) #10 AWG PV-WIRE CONDUCTORS (1) #6 AWG BARE COPPER GROUND AR-02 (2) 375W JINKO EAGLE 66TR G4 MODULES: JKM375M-6RL3-B IN (1) PARTIAL STRING OF (10) MODULES AT (19°) PITCH AND (180°) ORIENTATION (2) SOLAREDGE: P401 DC OPTIMIZERS SOLADECK 0799 SERIES UL50 TYPE 3R JUNCTION BOX 3/4" EMT OR EQUIVALENT (ON ROOF, UNDER EAVES) (2) #10 AWG THWN-2 CONDUCTORS (1) #10 AWG THWN-2 GROUND PV-5 CONTRACTOR SIGNATURE DRAWING TYPE PROJECT ADDRESS RYKER PARKINSON 154 ELM AVE REXBURG, ID 83440 DATE REVISION # SHEET NUMBER 5/26/2021HORIZON PWR 237 N 2ND ST, SUITE 202 REXBURG, ID 83440 888-468-7180 LICENSE #: 051666 ELECTRICAL DIAGRAM NO SCALE1 SINGLE LINE DIAGRAM 3.75 KW (DC) SOLAR ARRAY: (10) 375W JINKO SOLAR EAGLE 66TR G4 MODULES: JKM375M-6RL3-B, WITH (10) SOLAR EDGE POWER OPTIMIZERS: P401 WITH (1) SOLAR EDGE HD-WAVE 3.0KW INVERTER: SE3000H-US, WITH (1) STRINGS OF (10) MODULES IN SERIES. PV-6 CONTRACTOR SIGNATURE DRAWING TYPE PROJECT ADDRESS RYKER PARKINSON 154 ELM AVE REXBURG, ID 83440 DATE REVISION # SHEET NUMBER 5/26/2021HORIZON PWR 237 N 2ND ST, SUITE 202 REXBURG, ID 83440 888-468-7180 LICENSE #: 051666 ELECTRICAL CALCS ELECTRICAL NOTES ·ALL PV MODULES, ARRAY FRAMING AND RACKING SHALL BE GROUNDED PER MFR'S SPECIFICATIONS. ·ALL EQUIPMENT WILL BE UL 1703, UL 1741, OR UL 2703 LISTED AND CERTIFIED. ·MODULES WILL BE GROUNDED WITH INTEGRADED GROUNDING MODULE CLAMPS. ARRAY FRAME WILL BE GROUNDED WITH ILSCO GBL-4DBT (OR EQUIVALENT - SUITABLE FOR DIRECT BURIAL AND CONTACT WITH COPPER OR ALUMINUM) LAY IN TYPE GROUNDING LUG. USE SPECIFIED MODULE GROUNDING POINTS. ·ALL WIRE TERMINATIONS, SPLICES AND CONNECTIONS SHALL BE MADE USING A LISTED DEVICE OR ELECTRICAL BOX SUITED FOR THE PURPOSE. ALL WIRES NOT IN CONDUIT TO BE PROVIDED WITH STRAIN RELIEF AT ENTRY INTO JUNCTION BOXES. ·PROVIDE AND INSTALL CONDUIT EXPANSION FITTINGS, PER MANUFACTURER'S SPECIFICATIONS, IN CONDUIT RUNS WHERE THERMAL EXPANSION IS 0.25" OR MORE, BASED ON RECORD MAXIMUM AND MINIMUM TEMPERATURES FOR THE SITE (SEE NEC TABLE 310.15(B)(2)(C), AND USING EXPANSION COEFFICIENT OF STEEL. ·BOTH ENDS OF ALL METALLIC CONDUIT CONTAINING GROUNDING ELECTRODE CONDUCTORS SHALL BE BONDED PER NEC 250.64(E). ·PROVIDE AND INSTALL ALL GROUNDING AS REQUIRED BY NEC ARTICLES 250, 690 AND SYSTEM MANUFACTURER. ·INSTALLATIONS WHICH USE TRANSFORMER-LESS INVERTERS - PV WIRE TYPE IS REQUIRED FOR ALL DC WIRE RUNS IN FREE AIR, OR NOT IN CONDUIT. ·EACH CURRENT CARRYING CONDUCTOR IN ALL PV SOURCE CIRCUITS OR PV OUTPUT CIRCUITS SHALL BE DISCONNECTED/ FUSED, WHEN NECESSARY. ·CONTRACTOR SHALL VERIFY EXISTENCE OF UNDERGROUND UTILITIES PRIOR TO ANY EXCAVATIONS. ·ELECTRICAL TRENCH RUNS, WHERE USED, SHALL USE SCHEDULE 40 PVC CONDUIT AND PROVIDE 18" MIN CLEARANCE FROM TOP OF CONDUIT TO GRADE, AND MAGNETIC WARNING TAPE AT 12" BELOW GRADE. 24" CLEARANCE AND SCHEDULE 80 PVC IS REQUIRED IN AREAS WHERE SUBJECT TO VEHICLE TRAFFIC. ·CHECK WITH LOCAL JURISDICTION FOR ANY ADDITIONAL FILL AND COMPACTION REQUIREMENTS, SPOILS TREATMENT AND/OR EROSION CONTROL MEASURES PRIOR TO EXCAVATION. ·INSTALLATIONS IN LIGHTENING-PRONE LOCATIONS ARE RECOMMENDED TO UTILIZE DC LIGHTENING ARRESTORS IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ·SUPPLY SIDE CONNECTIONS SHALL ONLY BE MADE WITH LISTED AND APPROVED TAPS. ·ALL WIRE RUNS SHALL NOT EXCEED 2% CALCULATED VOLTAGE DROP. ·VERIFY EXISTING GROUNDING ELECTRODE. IF NONE EXISTS, A NEW GROUND ROD MAY BE REQUIRED. MIN. SIZE 8' LONG x 5/8" DIA, COPPER CLAD. BOND TO GAS, AND HOT AND COLD WATER PIPES. ·USE WATERPROOF FITTINGS FOR ALL EXTERIOR CONDUIT. ·GROUNDING ELECTRODE CONDUCTOR (AC SIDE OF INVERTER) IS #8 IF IN CONDUIT, OR #6 AWG IF EXPOSED AND SUBJECT TO DAMAGE, AND SHALL BE CONTINUOUS FROM INVERTER TO GROUND ROD. USE IRREVERSIBLE SPLICES WHERE NECESSARY. ·EQUIPMENT GROUNDING CONDUCTOR (DC SIDE OF INVERTER) IS #10 IF IN CONDUIT, OR #6 AWG IF EXPOSED AND SUBJECT TO DAMAGE (NEC 690.46). ALLOWABLE SOLAR BACKFEED CALCULATION AT MSP BUS BAR RATING 100 A MAIN BREAKER RATING 100 A SOLAR BACKFEED BREAKER 20 A MAX ALLOWABLE BACKFEED (100A X 120%) - 100A BREAKER = 20A ALLOWABLE ≥ 20A SOLAR, OK TO CONNECT VIA PV BREAKER (PER NEC 705.12). DC MAX VOLTAGE CALCULATION (COLD TEMP) MODULE VOC 44.12 VDC VOC TEMP COEFFICIENT -0.28%/°C EXTREME LOW TEMP -22 °C ΔT FROM STC 47 °C ΔVOC 5.81 VDC ADJUSTED MODULE VOC 49.93 VDC ADJUSTED STRING VOLTAGE FOR LOW TEMP 49.93 VDC < 60 VDC, SO OK ASSUMPTIONS: HIGH TEMPERATURE = 29 °C LOW TEMPERATURE = -22 °C ADDED TEMPERATURE FOR CONDUIT ON ROOF = 22 °C 60 °C RATED WIRE FOR ROMEX 75 °C RATED WIRE FOR AC CURRENT THAT TERMINATES AT A BREAKER DC AMPACITY CALCULATION MAX OUTPUT CURRENT 15.0 A CONTINUOUS DUTY AND HIGH IRIDESCENCE FACTOR 1.56 MULTIPLE CONDUCTOR FACTOR 1.0 TEMP CORRECTION FACTOR 0.76 AMPACITY OF #10 WIRE (@ 90 °C)40 A MAXIMUM AMPACITY 15.0 A * 1.56 = 23.4 A < 40 A ADJUSTED AMPACITY 40 A * 1.0 * 0.76 = 30.4 A > 18.8 A CALCULATIONS: VMPP = 380 V VMAX = 480 V IMAX = 15 A IMPP = (10 MODULES) * 375 W / 380 V = 9.9 A < 15.0 A, SO OK ISC = 11.01 A < 11.75 A, SO OK VMAX = 49.93 V < 60 V, SO OK AC AMPACITY CALCULATION FOR 3.0 KW INVERTER INVERTER OUTPUT CURRENT 12.5 A CONTINUOUS DUTY FACTOR 1.25 MULTIPLE CONDUCTOR FACTOR 1.0 TEMP CORRECTION FACTOR 1.0 AMPACITY OF #10 WIRE (USE 75°)35.0 A MAXIMUM AMPACITY 12.5 A * 1.25 = 15.6 A < 35.0 A ADJUSTED AMPACITY 35 A * 1.0 * 1.0 = 35.0 A > 12.5 A INVERTER OCPD RATING 20 A INVERTER SPECS MAKE SOLAR EDGE MODEL SE3000H-US RATED AC POWER 3000 W TRANSFORMERLESS, UNGROUNDED YES MAX INPUT VOLTAGE 480 VDC NOMINAL INPUT VOLTAGE 380 VDC MAX INPUT CURRENT 8.5 A RATED AC VOLTAGE 240 VAC AC VOLTAGE RANGE 211 - 264 VAC MAX AC OUTPUT CURRENT 12.5 A AC OVERCURRENT PROTECTION 20 A POWER OPTIMIZER SPECS MAKE SOLAR EDGE MODEL P401 RATED DC POWER 400 W MAX INPUT VOLTAGE 60 VDC MPPT OPERATING RANGE 8 - 60 VDC MAX ISC INPUT CURRENT 11.75 A MAX OUTPUT CURRENT 15 A OPERATING OUTPUT VOLTAGE 5 - 60 VDC MAX ALLOWED SYSTEM VOLTAGE 480 VDC NUMBER OF UNITS PER STRING 8-15 MAX POWER PER STRING 5700 W PV MODULE SPECS MAKE JINKO SOLAR: EAGLE 66TR G4 MODEL JKM375M-6RL3-B SHORT CIRCUIT CURRENT 11.01 A OPEN CIRCUIT VOLTAGE 44.12 VDC OPERATING CURRENT 10.19 A OPERATING VOLTAGE 36.80 VDC NOMINAL POWER 375 W V(OC) TEMPERATURE COEFFINIENT -0.28 %/°C 3.75 KW (DC) SOLAR ARRAY: (10) 375W JINKO SOLAR EAGLE 66TR G4 MODULES: JKM375M-6RL3-B, WITH (10) SOLAR EDGE POWER OPTIMIZERS: P401 WITH (1) SOLAR EDGE HD-WAVE 3.0KW INVERTER: SE3000H-US, WITH (1) STRINGS OF (10) MODULES IN SERIES. PV-7 CONTRACTOR SIGNATURE DRAWING TYPE PROJECT ADDRESS RYKER PARKINSON 154 ELM AVE REXBURG, ID 83440 DATE REVISION # SHEET NUMBER 5/26/2021HORIZON PWR 237 N 2ND ST, SUITE 202 REXBURG, ID 83440 888-468-7180 LICENSE #: 051666 PLACARDS PLACARDS1 SIGNAGE NOTES ·SIGNAGE SHALL BE PERMANENTLY AFFIXED TO EQUIPMENT WITH POP-RIVETS, SCREWS OR APPROVED ADHESIVE. ·OUTDOOR SIGNAGE SHALL BE UV STABLE AND SUITABLE FOR ITS ENVIRONMENT. CONDUIT STICKERS SHALL BE SHALL BE REFLECTIVE. ·PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PHOTO PLATING, SHALL HAVE RED BACKGROUND WITH WHITE LETTERING. MINIMUM FONT SIZE SHALL BE 3/8" HEIGHT AND ALL CAPITAL LETTERS. ·DEVICES MARKED WITH "LINE" AND "LOAD" ARE NOT SUITABLE FOR FOR BACKFEED OR REVERSE CURRENT. ·SIGNAGE CANNOT BE HAND WRITTEN. ·NET METER BASE, PRODUCTION METER BASE, AND SOLAR AC DISCONNECT ENGRAVED LABELS MUST BE MECHANICALLY FASTENED WITH RIVETS, SCREWS, OR BOLTS. LABEL PLACEMENT: MAIN SERVICE PANEL SOLAR PV SYSTEM AC POINT OF CONNECTION AC OUTPUT CURRENT 12.5 A NOMINAL AC VOLTAGE 240 V THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) LABEL PLACEMENT: MAIN SERVICE PANEL RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSYEM REFELECTIVE MATERIAL REQUIRED PLACEMENT: INVERTER, AC DISCONNECTS LABEL PLACEMENT: MAIN PANEL NEAR METER LABEL PLACEMENT: AC BREAKER (INSIDE OF PANEL, NEXT TO BREAKER) LABEL PLACEMENT: AC DISCONNECTS, PV BREAKER LABEL PLACEMENT: ALL AC AND DC DISCONNECTS WEATHER RESISTANT PLASTIC PLACARD PLACEMENT: AC DISCONNECTLABEL USED ON UNGROUNDED SYSTEMS ONLY PLACEMENT: INVERTER, DC DISCONNECT LABEL PLACEMENT: INVERTER, AC DISCONNECT LABEL PLACEMENT: INVERTER LABEL PLACEMENT: AC CONDUIT LABEL PLACEMENT: FD MARKING REQUIREMENTS: WARNING LABEL SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, JUNCTION BOXES, AND DISCONNECTS. MARKING SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES EVERY 10 FEET (3048 MM) 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS LABEL PLACEMENT: DC DISCONNECT LABEL PLACEMENT: AC BREAKER (INSIDE OF PANEL, NEXT TO BREAKER) WARNING: ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. PV SYSTEM DISCONNECT FOR UTILITY OPERATION WARNING - Dual Power Sources Second source is photovoltaic system WARNING - Electric Shock Hazard No user serviceable parts inside Contact authorized servicer for assistance WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED WARNING: PHOTOVOLTAIC POWER SOURCE WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED PHOTOVOLTAIC POWER SOURCESOLAR DISCONNECT WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPICITY OF BUSBAR.LABEL PLACEMENT: MAIN PANEL (COVER) LABEL PLACEMENT: INVERTER 1 DIRECT CURRENT PHOTOVOLTAIC POWER SOURCE MAXIMUM VOLTAGE 480.0 V MAXIMUM CIRCUIT CURRENT 8.5 A MAXIMUM RATED OUTPUT CURRENT OF DC-TO-DC CONVERTER 15.0 A SITE DIRECTORY 154 ELM AVE REXBURG, ID 83440 WARNING POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: PV AC DISCONNECT SWITCH PV DC DISCONNECT ON INVERTER MAIN SERVICE PANEL AND UTILITY METER "YOU ARE HERE" PV SOLAR ARRAY PV SOLAR ARRAY • NYSE-listed since 2010, Bloomberg Tier 1 manufacturer • Best-selling panel globally for last 4 years • Top performance in the strictest 3rd party labs • 99.9% on-time delivery to the installer • Premium solar panel factories in USA and Malaysia EAGLE 66TR G4 370-390 WATT TILING RIBBON MODULE Positive power tolerance of 0~+3% KEY FEATURES BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US SOLAR BRAND THE MOST DEPENDABLE TR Technology Tiling Ribbon eliminates cell gaps to increase module efficiency and power. 9BB Half Cell Technology Uniquely designed 9 busbar half cut solar cells deliver ultra-high power in a small footprint. Shade Tolerant Twin array design allows continued performance even with shading by trees or debris. Designed for Long Life Uses the same DuPont protective film as the Space Station, Mars Lander, and jetliners. Leading Warranty 12-year product and 25-year linear power warranty; 98% guaranteed first year, max 0.55% annual loss. 25 ENGINEERING DRAWINGS PACKAGING CONFIGURATION TEMPERATURE CHARACTERISTICS MAXIMUM RATINGS MECHANICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS No. of Cells 132 (2x66) Dimensions 1855x1029x35mm (73.03×40.51×1.37 in) Weight 21.5 kg (47.40 lbs) Front Glass 3.2mm, Anti-Reflection Coating High Transmission, Low Iron, Tempered Glass Frame Anodized Aluminum Alloy Junction Box IP67 Rated Output Cables 12 AWG, 2053mm (80.83in) or Customized Length Connector MC4 Fire Type Type 1 Pressure Rating 5400Pa (Snow) & 2400Pa (Wind) 2 pallets = 1 stack; 31pcs/pallets, 62pcs/stack, 744pcs/ 40’HQ Container Temperature Coefficients of Pmax -0.35%/°C Temperature Coefficients of Voc -0.28%/°C Temperature Coefficients of Isc 0.048%/°C Nominal Operating Cell Temperature (NOCT)45 ± 2°C Operating Temperature (°C)-40°C~+85°C Maximum System Voltage 1000VDC Maximum Series Fuse Rating 20A Module Type JKM370M-6RL3-B JKM375M-6RL3-B JKM380M-6RL3-B JKM385M-6RL3-B JKM390M-6RL3-B STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT Maximum Power (Pmax)370Wp 275Wp 375Wp 279Wp 380Wp 283Wp 385Wp 286Wp 390Wp 290Wp Maximum Power Voltage (Vmp)36.71V 33.49V 36.80V 33.57V 36.90V 33.70V 37.02V 33.90V 37.15V 34.02V Maximum Power Current (Imp)10.08A 8.22A 10.19A 8.31A 10.30A 8.39A 10.40A 8.45A 10.50A 8.53A Open-circuit Voltage (Voc)44.02V 41.55V 44.12V 41.64V 44.22V 41.74V 44.34V 41.85V 44.47V 41.97V Short-circuit Current (lsc)10.90A 8.80A 11.01A 8.89A 11.12A 8.98A 11.22A 9.06A 11.32A 9.14A Module Efficiency STC (%)19.38%19.65%19.91%20.17%20.43% ELECTRICAL PERFORMANCE & TEMPERATURE DEPENDENCE BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US *STC: Irradiance 1000W/m2 NOCT: Irradiance 800W/m2 *Power measurement tolerance: +/- 3% Cell Temperature 25°C Ambient Temperature 20°C AM = 1.5 AM = 1.5 Wind Speed 1m/s The company reserves the final right for explanation on any of the information presented hereby. JKM370-390M-6RL3-B-A1-US Voltage (V) Temperature Dependence of Isc, Voc, Pmax Current-Voltage & Power-Voltage Curves (390W) Front Side Back Length: +/- 2mm Width: +/- 2mm Height: +/- 1mm Row Pitch: +/- 2mm Cell Temperature (°C) • ISO9001:2008 Quality Standards • ISO14001:2004 Environmental Standards • IEC61215, IEC61730 certified products • UL61730 Certification • ISO45001:2018 Occupational Health & Safety Standards 25-Year Performance Warranty KEY FEATURESLINEAR PERFORMANCE WARRANTY Diamond Half Cell Technology World-record breaking efficient mono PERC half cut solar cells deliver high power in a small footprint. Designed for Long Life Uses the same DuPont protective film as the Space Station, Mars Lander, and jetliners. 25-year warranty. Shade Tolerant Twin array design allows continued performance even with shading by trees or debris. Power Boost in Cloudy Conditions A special film diffuses light, boosting performance even without direct sunlight. Protected Against All Environments Certified to withstand humidity, heat, rain, marine environments, wind, hailstorms, and packed snow. BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US • NYSE-listed since 2010, Bloomberg Tier 1 manufacturer • Best-selling panel globally for last 4 years • Top performance in the strictest 3rd party labs • 99.9% on-time delivery to the installer • Automated manufacturing utilizing artificial intelligence • Vertically integrated, tight controls on quality • Premium solar assembly in USA and Malaysia EAGLE 60HM G2 310-330 WATT • HALF CELL MONO PERC MODULE Positive power tolerance of 0~+3% • ISO9001:2008 Quality Standards • ISO14001:2004 Environmental Standards • IEC61215, IEC61730 certified products • OHSAS18001 Occupational Health & Safety Standards • UL1703 certified products SOLAR BRAND THE MOST DEPENDABLE Years 1 5 10 15 20 25Guaranteed power performance97.5% 83.1% 100% 60% 40% 20% 0% Nomenclature: JKM330M - 60HBL Code Cell Code Backsheet Code Cell null Full null White null Normal H Half B Black L Diamond 25-Year Performance Warranty KEY FEATURESLINEAR PERFORMANCE WARRANTY Diamond Half Cell Technology World-record breaking efficient mono PERC half cut solar cells deliver high power in a small footprint. Designed for Long Life Uses the same DuPont protective film as the Space Station, Mars Lander, and jetliners. 25-year warranty. Shade Tolerant Twin array design allows continued performance even with shading by trees or debris. Power Boost in Cloudy Conditions A special film diffuses light, boosting performance even without direct sunlight. Protected Against All Environments Certified to withstand humidity, heat, rain, marine environments, wind, hailstorms, and packed snow. BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US • NYSE-listed since 2010, Bloomberg Tier 1 manufacturer • Best-selling panel globally for last 4 years • Top performance in the strictest 3rd party labs • 99.9% on-time delivery to the installer • Automated manufacturing utilizing artificial intelligence • Vertically integrated, tight controls on quality • Premium solar assembly in USA and Malaysia EAGLE 60HM G2 310-330 WATT • HALF CELL MONO PERC MODULE Positive power tolerance of 0~+3% • ISO9001:2008 Quality Standards • ISO14001:2004 Environmental Standards • IEC61215, IEC61730 certified products • OHSAS18001 Occupational Health & Safety Standards • UL1703 certified products SOLAR BRAND THE MOST DEPENDABLE Years 1 5 10 15 20 25Guaranteed power performance97.5% 83.1% 100% 60% 40% 20% 0% Nomenclature: JKM330M - 60HBL Code Cell Code Backsheet Code Cell null Full null White null Normal H Half B Black L Diamond The company reserves the final right for explanation on any of the information presented hereby. TR JKM380-400M-6RL3-B-A2-EN-F35 (IEC2016) Engineering Drawings SPECIFICATIONS Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5STC: Irradiance 800W/m 2 AM=1.5NOCT: Power measurement tolerance: ± 3%* * Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature(℃) Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C Temperature Dependence of Isc,Voc,Pmax -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax Current-Voltage & Power-Voltage Curves (380W) 5 10 15 20 25 30 35 40 45 500 0 2 4 6 8 10 12 0 70 140 210 350 280 420 STC NOCTSTC NOCT TCONCTS -40℃~+85℃ 1000VDC (IEC) 20A 0~+3% -0.35%/℃ -0.28%/℃ 0.048%/℃ 45±2℃ TCONCTS 20.17% 385Wp 37.02V 10.40A 44.34V 11.22A 286Wp 8.45A 33.90V 41.85V 9.06A JKM385M-6RL3-B JKM390M-6RL3-B JKM395M-6RL3-B JKM400M-6RL3-B 20.43% 390Wp 37.15V 10.50A 44.47V 11.32A 290Wp 8.53A 34.02V 41.97V 9.14A 20.69% 395Wp 37.27V 10.60A 44.59V 11.42A 294Wp 8.61A 34.13V 42.09V 9.22A 20.96% 400Wp 37.39V 10.70A 44.71V 11.52A 298Wp 8.69A 34.25V 42.20V 9.30A STC NOCT JKM380M-6RL3-B 19.91% 380Wp 36.90V 10.30A 44.22V 11.12A 283Wp 8.39A 33.70V 41.74V 8.98A1855mm (73.03")1029 mm (40.51") A A H 1360mm (53.54")860mm (33.86")981mm (38.62")3535 R4. 5 149 Lenth: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm Packaging Configuration ( Two pallets = One stack ) 31pcs/pallets, 62pcs/stack, 744pcs/ 40'HQ Container Mechanical Characteristics Cell Type No.of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22.1kg (48.72 lbs) IP67 Rated TUV 1×4.0mm2 (+): 290mm , (-): 145 mm or Customized Length 3.2mm,Anti-Reflection Coating, High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1855×1029×35mm (73.03×40.51×1.37 inch) 132 (2×66) P type Mono-crystalline 35 35 C CB B A The company reserves the final right for explanation on any of the information presented hereby. TR JKM380-400M-6RL3-B-A2-EN-F35 (IEC2016) Engineering Drawings SPECIFICATIONS Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5STC: Irradiance 800W/m 2 AM=1.5NOCT: Power measurement tolerance: ± 3%* * Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature(℃) Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C Temperature Dependence of Isc,Voc,Pmax -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax Current-Voltage & Power-Voltage Curves (380W) 5 10 15 20 25 30 35 40 45 500 0 2 4 6 8 10 12 0 70 140 210 350 280 420 STC NOCTSTC NOCT TCONCTS -40℃~+85℃ 1000VDC (IEC) 20A 0~+3% -0.35%/℃ -0.28%/℃ 0.048%/℃ 45±2℃ TCONCTS 20.17% 385Wp 37.02V 10.40A 44.34V 11.22A 286Wp 8.45A 33.90V 41.85V 9.06A JKM385M-6RL3-B JKM390M-6RL3-B JKM395M-6RL3-B JKM400M-6RL3-B 20.43% 390Wp 37.15V 10.50A 44.47V 11.32A 290Wp 8.53A 34.02V 41.97V 9.14A 20.69% 395Wp 37.27V 10.60A 44.59V 11.42A 294Wp 8.61A 34.13V 42.09V 9.22A 20.96% 400Wp 37.39V 10.70A 44.71V 11.52A 298Wp 8.69A 34.25V 42.20V 9.30A STC NOCT JKM380M-6RL3-B 19.91% 380Wp 36.90V 10.30A 44.22V 11.12A 283Wp 8.39A 33.70V 41.74V 8.98A1855mm (73.03")1029 mm (40.51") A A H 1360mm (53.54")860mm (33.86")979mm (38.54")3535 R4. 5 149 Lenth: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm Packaging Configuration ( Two pallets = One stack ) 31pcs/pallets, 62pcs/stack, 744pcs/ 40'HQ Container Mechanical Characteristics Cell Type No.of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22.1kg (48.72 lbs) IP67 Rated TUV 1×4.0mm2 (+): 290mm , (-): 145 mm or Customized Length 3.2mm,Anti-Reflection Coating, High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1855×1029×35mm (73.03×40.51×1.37 inch) 132 (2×66) P type Mono-crystalline The company reserves the final right for explanation on any of the information presented hereby. TR JKM380-400M-6RL3-B-A2-EN-F35 (IEC2016) Engineering Drawings SPECIFICATIONS Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5STC: Irradiance 800W/m 2 AM=1.5NOCT: Power measurement tolerance: ± 3%* * Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature(℃) Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C Temperature Dependence of Isc,Voc,Pmax -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax Current-Voltage & Power-Voltage Curves (380W) 5 10 15 20 25 30 35 40 45 500 0 2 4 6 8 10 12 0 70 140 210 350 280 420 STC NOCTSTC NOCT TCONCTS -40℃~+85℃ 1000VDC (IEC) 20A 0~+3% -0.35%/℃ -0.28%/℃ 0.048%/℃ 45±2℃ TCONCTS 20.17% 385Wp 37.02V 10.40A 44.34V 11.22A 286Wp 8.45A 33.90V 41.85V 9.06A JKM385M-6RL3-B JKM390M-6RL3-B JKM395M-6RL3-B JKM400M-6RL3-B 20.43% 390Wp 37.15V 10.50A 44.47V 11.32A 290Wp 8.53A 34.02V 41.97V 9.14A 20.69% 395Wp 37.27V 10.60A 44.59V 11.42A 294Wp 8.61A 34.13V 42.09V 9.22A 20.96% 400Wp 37.39V 10.70A 44.71V 11.52A 298Wp 8.69A 34.25V 42.20V 9.30A STC NOCT JKM380M-6RL3-B 19.91% 380Wp 36.90V 10.30A 44.22V 11.12A 283Wp 8.39A 33.70V 41.74V 8.98A1855mm (73.03")1029 mm (40.51") A A H 1360mm (53.54")860mm (33.86")979mm (38.54")3535 R4. 5 149 Lenth: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm Packaging Configuration ( Two pallets = One stack ) 31pcs/pallets, 62pcs/stack, 744pcs/ 40'HQ Container Mechanical Characteristics Cell Type No.of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22.1kg (48.72 lbs) IP67 Rated TUV 1×4.0mm2 (+): 290mm , (-): 145 mm or Customized Length 3.2mm,Anti-Reflection Coating, High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1855×1029×35mm (73.03×40.51×1.37 inch) 132 (2×66) P type Mono-crystalline The company reserves the final right for explanation on any of the information presented hereby. TR JKM380-400M-6RL3-B-A2-EN-F35 (IEC2016) Engineering Drawings SPECIFICATIONS Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5STC: Irradiance 800W/m 2 AM=1.5NOCT: Power measurement tolerance: ± 3%* * Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature(℃) Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C Temperature Dependence of Isc,Voc,Pmax -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax Current-Voltage & Power-Voltage Curves (380W) 5 10 15 20 25 30 35 40 45 500 0 2 4 6 8 10 12 0 70 140 210 350 280 420 STC NOCTSTC NOCT TCONCTS -40℃~+85℃ 1000VDC (IEC) 20A 0~+3% -0.35%/℃ -0.28%/℃ 0.048%/℃ 45±2℃ TCONCTS 20.17% 385Wp 37.02V 10.40A 44.34V 11.22A 286Wp 8.45A 33.90V 41.85V 9.06A JKM385M-6RL3-B JKM390M-6RL3-B JKM395M-6RL3-B JKM400M-6RL3-B 20.43% 390Wp 37.15V 10.50A 44.47V 11.32A 290Wp 8.53A 34.02V 41.97V 9.14A 20.69% 395Wp 37.27V 10.60A 44.59V 11.42A 294Wp 8.61A 34.13V 42.09V 9.22A 20.96% 400Wp 37.39V 10.70A 44.71V 11.52A 298Wp 8.69A 34.25V 42.20V 9.30A STC NOCT JKM380M-6RL3-B 19.91% 380Wp 36.90V 10.30A 44.22V 11.12A 283Wp 8.39A 33.70V 41.74V 8.98A1855mm (73.03")1029 mm (40.51") A A H 1360mm (53.54")860mm (33.86")981mm (38.62")3535 R4. 5 149 Lenth: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm Packaging Configuration ( Two pallets = One stack ) 31pcs/pallets, 62pcs/stack, 744pcs/ 40'HQ Container Mechanical Characteristics Cell Type No.of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22.1kg (48.72 lbs) IP67 Rated TUV 1×4.0mm2 (+): 290mm , (-): 145 mm or Customized Length 3.2mm,Anti-Reflection Coating, High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1855×1029×35mm (73.03×40.51×1.37 inch) 132 (2×66) P type Mono-crystalline 35 35 C CB B A INVERTERSsolaredge.com Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Fixed voltage inverter for longer strings UL1741 SA certified, for CPUC Rule 21 grid compliance Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 Small, lightweight, and easy to install both outdoors or indoors Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEARWARRANTY MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)----Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Single Phase Inverter with HD-Wave Technology for North America MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(3)Consumption metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown - NEC 2014, NEC 2017 and NEC 2020, 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14-6 AWG 1'' Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1-2 strings / 14-6 AWG 1'' Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(4)˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (3) Inverter with Revenue Grade Meter P/N: SExxxxH-US000BNC4; Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BNI4 . For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box(4) Full power up to at least 50˚C / 122˚F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2020/V01/ENG NAM. Subject to change without notice. POWER OPTIMIZERsolaredge.com PV power optimization at the module-level Specifically designed to work with SolarEdge inverters Up to 25% more energy Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module- level monitoring Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Power Optimizer For North America P370 / P400 / P401 / P485 / P505 25 YEARWARRANTY © SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 01/2021/V02/ENG NAM. Subject to change without notice. (6) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf(7) It is not allowed to mix P485/P505 with P370/P400/P401 in one string(8) If the inverters rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to: https://www.solaredge. com/sites/default/files/se-power-optimizer-single-string-design-application-note.pdf (9) For 208V grid: it is allowed to install up to 7,200W per string when the maximum power difference between each string is 1,000W(10) For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W Power Optimizer For North America P370 / P400 / P401 / P485 / P505 Optimizer model(typical module compatibility) P370(for higher-power 60 and 72-cell modules) P400 (for 72 & 96-cell modules) P401(for high power 60 and 72 cell modules) P485 (for high-voltage modules) P505 (for higher current modules) INPUT Rated Input DC Power(1)370 400 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 60 80 60 125 83 Vdc MPPT Operating Range 8 - 60 8 - 80 8-60 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 11.75 11 14 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014, 2017(2) & 2020 NEC 2014 & 2020 NEC 2014, 2017(2) & 2020 EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0 , UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H)129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 153 x 29.5 /5.1 x 6 x 1.16 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in Weight (including cables)655 / 1.4 750 / 1.7 655 / 1.4 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(3)Single or dual MC4(3)(4)MC4(3) Input Wire Length 0.16 / 0.52, 0.9 / 2.95(4)0.16 / 0.52 0.16 / 0.52, 0.9 / 2.95(4)0.16 / 0.52 0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 1.2 / 3.9 m / ft Operating Temperature Range(5) -40 to +85 / -40 to +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed(2) NEC 2017 requires max input voltage be not more than 80V(3) For other connector types please contact SolarEdge(4) For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals(5) For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details PV System Design Using a SolarEdge Inverter(6)(7) Single Phase HD-Wave Single phase Three Phase for 208V grid Three Phase for 277/480V grid Minimum String Length (Power Optimizers) P370, P400, P401 8 10 18 P485, P505 6 8 14 Maximum String Length (Power Optimizers)25 25 50 Maximum Nominal Power per String 5700(8) (6000 with SE7600-US - SE11400-US)5250(8)6000(9)12750(10)W Parallel Strings of Different Lengths or Orientations Yes SolarEdge P-5 Series Power Optimizers Grounding Using a Grounding Plate When the power optimizer is mounted on a grounded structure, equipment grounding is usually done using the star washer supplied with the optimizers (refer to the SolarEdge Installation Guide). For selected mounting systems with sliding nut fasteners, use the SolarEdge grounding plate (part number SE-GNDPLATE-100) instead of the supplied star washer as described below. The SolarEdge grounding plate penetrates the galvanized or anodized coating of the structure to ensure a low-resistance connection (per UL1741 certification). For information about grounding mounting systems using the SolarEdge grounding methods, refer to the Grounding SolarEdge Power Optimizers application note available on the SolarEdge website at: http://www.solaredge.com/files/pdfs/grounding_se_power_optimizers.pdf To establish equipment grounding: 1. Slide the nut fastener in the desired location in the rail. 2. Attach a grounding plate to the power optimizer (see Figure 1): Insert the two plate tubs into the two designated holes in the power optimizer back cover. 3. Install the power optimizer onto the rail using hardware suitable for the specific mounting structure ( screws, nuts, bolts, washers, etc. not supplied by SolarEdge). 4. Tighten the screw with a torque of 9.5 N*m / 7 lb*ft. Figure 1: Example of grounding a power optimizer using the grounding plate Rail with sliding nut fastener Insert the plate tabs into the indicated holes Grounding plate Mounting structure specific hardware (not supplied by SolarEdge) SolarEdge P-5 Series Power Optimizers Grounding Using a Grounding Terminal Power optimizers that are available for North America (part numbers: Pxxx-2N and Pxxx-5N) must be grounded. When the power optimizer is mounted on a grounded structure, equipment grounding is done using the washers supplied with the optimizers (refer to the SolarEdge Installation Guide). When the power optimizer is mounted on an un-grounded structure, such as a wooden structure, grounding terminals (kit part number: SE-GNDLUG5-100, 100 terminals in one kit) are used to create equipment grounding. . To establish equipment grounding: 1. When installing the power optimizer, attach a grounding terminal to each power optimizer (see Figure 1). 2. Connect an equipment-grounding conductor to the grounding terminal. The grounding terminal accepts a wire size of 6- 14 AWG and must be sized for equipment per NEC 250.122. 3. Tighten the screw connecting the power optimizer to the rack with a torque of 9.5 N*m / 7 lb*ft. Figure 1: Grounding a power optimizer using the grounding terminal kit AUTHORIZATION TO MARK Applicant:Manufacturer: Address:Address: Country:Country: Contact:Contact: Phone:Phone: FAX:FAX: Email:Email: Standard(s): Product: Brand Name: Models: This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2010 Ed.2+R:15Feb2018] Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4] Power Box and Power Optimizer PB followed by 001 to 350; followed by -AOB or -TFI. OP followed by 001 to 500; followed by -LV, -MV, -IV or -EV. P followed by 001 to 960. SP followed by 001 to 350. SolarEdge Control Number:4004590 Authorized by: for L. Matthew Snyder, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. oren.b@solaredge.com emily_chen2@jabil.com Party Authorized To Apply Mark:Same as Manufacturer Report Issuing Office:3933 US Route 11, Cortland NY 13045 Oren Bachar Emily Chen +972 9 957 6620 86-20 2805 5789 +972 9 957 6591 NA Solar Edge Technologies LTD Jabil Circuit (Guangzhou) LTD 1 HaMada Street Herzeliya 4673335 GUANGZHOU ECNMC & TECH DEV EAST DISTRICT 128 JUN CHENG RD GUANGZHOU GUANGDONG 510530 CHINA Israel China This authorizes the application of the Certification Mark(s)shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report.This authorization also applies to multiple listee model(s)identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable.The certification mark(s)may ATM for Report 100269032CRT-001 Page 1 of 5 ATM Issued: 18-Jun-2020 ED 16.3.15 (20-Apr-17) Mandatory 3933 US Route 11 Cortland, NY 13045 Telephone: 607 758 6711 Facsimile: 607-753-1045 www.intertek.com Page 1 of 1 This report is for the exclusive use of Intertek’s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek’s responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. Intertek Testing Services NA, Inc. SD 12.1.2 (11/11/10) Informative 05/3/2013 Mr. Meir Adest SolarEdge Technologies 6 Ha’Harash St. Hod Hasharon, 45240 Israel Subject: Grounding testing of Solaredge optimizer as part of UL 1741 certification. Dear Mr. Adest, This letter is to confirm that the grounding of the Solaredge optimizer, as described in the Solaredge manual, was tested as part of the listing evaluation and complied with the standard’s requirement of less than 0.1 Ohm resistance. If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. Please note; this Letter Report does not represent authorization for the use of any Intertek certification marks. Troy Hewitt Global Business Leader Wind Energy Intertek 3933 US Route 11 Cortland NY, 13045 USA Intertek 3933 US Route 11 Cortland, NY 13045 Telephone: 607-753-7311 www.intertek.com Subject: ETL Evaluation of SolarEdge Products to NEC 2017 Rapid Shutdown Requirements To, whom it may concern This letter represents the testing results of the below listed products to the requirements contained in the following standards: The evaluation was done on the PV Rapid Shutdown System (PVRSS), and covers installations consisting of optimizers and inverters with part numbers listed below. The testing done has verified that controlled conductors are limited to: • Not more than 30 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation outside the array. • Not more than 80 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation inside the array. The rapid shutdown initiation is performed by either disconnecting the AC feed to the inverter, or – if the inverter DC Safety switch is readily accessible – by turning off the DC Safety switch. Applicable products: (1) Power optimizers: PB followed by 001 to 350; followed by -AOB or -TFI. OP followed by 001 to 500; followed by -LV, -MV, -IV or -EV. P followed by 001 to 960. SP followed by 001 to 350. When optimizers are connected to 2 or more modules in series, the max input voltage may exceed 80V. Following the implementation of the NEC 2017 rapid shutdown value of 80V max inside of the array at the beginning of 2019, modules exceeding this combined input max voltage will be required to use optimizers with parallel inputs. (2) 1 -PH Inverters SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A- US / SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US when the following label is labeled on the side of the inverter: Inverter part number may be followed by a suffix. (3) 3 -PH Inverters SE9KUS / SE10KUS / SE14.4KUS/ SE16.7kUS / SE17.3kUS / SE20KUS / SE30KUS / SE33.3KUS/ SE40KUS /SE43.2KUS / SE66.6KUS / SE100KUS; when the following label is labeled on the side of the inverter: Intertek 3933 US Route 11 Cortland, NY 13045 Telephone: 607-753-7311 www.intertek.com Please note, this Letter Report does not represent authorization for the use of any Intertek certification marks. Brand Name(s) SolarEdge Relevant Standard(s) UL 1741, UL 1741 CRD for rapid shutdown National Electric Code, 2017, Section 690.12 requirement for rapid shutdown Verification Issuing Office 3933 US Route 11, Cortland, NY 13045 NRTL Disclaimer, Different for each NRTL – Example: “This Verification is for the exclusive use of NRTL's Client and is provided pursuant to the agreement between NRTL and its Client. NRTL's responsibility and liability are limited to the terms and conditions of the agreement. NRTL assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or distribute this Verification. Any use of the NRTL name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by NRTL. The observations and test results referenced from this Verification are relevant only to the sample tested. This Verification by itself does not imply that the material, product, or service is or has ever been under an NRTL certification program.” Signature: Name: Mukund Rana Position: Engineering Team Leader Date: 7/28/2020 Flush Mount System Strength Tested All components evaluated for superior structural performance. PE Certified Pre-stamped engineering letters available in most states. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Design Assistant Online software makes it simple to create, share, and price projects. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. 25-Year Warranty Products guaranteed to be free of impairing defects. Built for solar’s toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Our components have been tested to the limit and proven in extreme environments, including Florida’s high-velocity hurricane zones. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 25-year warranty. Datasheet © 2020 IronRidge, Inc. All rights reserved. U.S. Patents: #8,695,290; #9,819,303; #9,865,938; Others Pending. Version 1.85 XR Rails Attachments Datasheet Design Assistant Go from rough layout to fully engineered system. For free. Go to IronRidge.com/design Resources XR100 Rail The ultimate residential solar mounting rail. • 8’ spanning capability • Heavy load capability • Clear and black finish BOSS™ Bonded Splices Bonded Structural Splices connect XR Rails together. • Integrated bonding • No tools or hardware • Self-centering stop tab XR10 Rail A low-profile mounting rail for regions with light snow. • 6’ spanning capability • Moderate load capability • Clear and black finish XR1000 Rail A heavyweight mounting rail for commercial projects. • 12’ spanning capability • Extreme load capability • Clear anodized finish FlashFoot2™ Flash and mount XR Rails with superior waterproofing. • Twist-on Cap eases install • Wind-driven rain tested • Mill and black finish Replace tiles and ensure superior waterproofing. • Flat, S, & W tile profiles • Form-fit compression seal • Single-lag universal base Knockout Tile Clamps & Grounding UFO™ Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear and black finish Stopper Sleeves Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • Sized to match modules • Clear and black finish CAMO™ Bond modules to rails while staying completely hidden. • Universal end-cam clamp • Tool-less installation • Fully assembled Endorsed by FL Building Commission Flush Mount is the first mounting system to receive Florida Product approval for 2017 Florida Building Code compliance. Learn More at bit.ly/floridacert Mount on tile roofs with a simple, adjustable hook. • Works on flat, S, & W tiles • Single-socket installation • Optional deck flashing All Tile Hook Flash and mount conduit, strut, or junction boxes. • Twist-on Cap eases install • Wind-driven rain tested • Secures ¾” or 1” conduit FlashVue™ Bonding Hardware Bond and attach XR Rails to roof attachments. • T & Square Bolt options • Nut uses 7/16” socket • Assembled and lubricated Tech Brief Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. XR Rail Family Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs Roof Mount utilizes XR Rails, along with optional all-in-one attachments, to secure systems flush against residential roofs. Corrosion-Resistant Materials XR Rails are compatible with FlashFoot and other pitched roof attachments. IronRidge offers a range of tilt leg options for flat roof mounting applications. All XR Rails are made of 6000-series aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. © 2020 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.20 Tech Brief Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria: ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. Load Rail Span Snow (PSF)Wind (MPH)4’5’ 4”6’8’10’12’ None 90 120 140 XR10 XR100 XR1000 160 20 90 120 140 160 30 90 160 40 90 160 80 160 120 160 XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 10 feet. • 10’ spanning capability • Heavy load capability • Clear & black anodized finish • Internal splices available XR10 XR10 is a sleek, low-profile mounting rail, designed for regions with light or no snow. It achieves spans up to 6 feet, while remaining light and economical. • 6’ spanning capability • Moderate load capability • Clear & black anodized finish • Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It’s built to handle extreme climates and spans up to 12 feet for commercial applications. • 12’ spanning capability • Extreme load capability • Clear anodized finish • Internal splices available *Table is meant to be a simplified span chart for conveying general rail capabilities. Use approved certification letters for actual design guidance. © 2020 IRONRIDGE, INC. VERSION 3.0 FLUSH MOUNT INSTALLATION MANUAL - 2 RATINGS Product markings are located on the Grounding Lug bolt head. MARKINGS UL 2703 LISTeD • Conforms to STD UL 2703 (2015) Standard for Safety First Edition: Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels. • Certified to CSA STD LTR AE-001-2012 Photovoltaic Module Racking Systems. • Max Overcurrent Protective Device (OCPD) Rating: 25A • Max Module Size: 25.6 ft² • Max Frameless Module Size for Canadian LTR-AE: 21.5 ft² • Module Orientation: Portrait or Landscape • CAMO Specific Allowable Design Load Rating: 50 PSF downward, 50 PSF upward, 15 PSF lateral • LTR AE Canadian Load Rating: 2400 PA • System Level Allowable Design Load Rating: meets minimum requirements of the standard (10 PSF downward, 5 PSF upward, 5 PSF lateral). Actual system structural capacity is defined by PE stamped certification letters. CLASS A SYSTeM FIRe RATING PeR UL 2703 • Any Roof Slope with Module Types 1, 2, 3, 13, 19, 25 & 29. • Any module-to-roof gap is permitted, with no perimeter guarding required. This rating is applicable with any third-party attachment.• Class A rated PV systems can be installed on Class A, B, and C roofs without affecting the roof fire rating. WATeR SeAL RATINGS: UL 441 & TAS 100(A)-95 (FLASHFOOT2, ALL TILe HOOK, KNOCKOUT TILe, FLASHVUe) • Tested and evaluated without sealant. • Any roofing manufacturer approved sealant is allowed. Ratings applicable for roof slopes between 2:12 and 12:12 STRUCTURAL CeRTIFICATION • Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7 FLORIDA PRODUCT APPROVAL #FL29843 • Conforms to TAS202, TAS100(A) • Approved for installation both inside and outside High Velocity Hurricane Zones (HVHZ) • Allowable design pressure up to +100/-100 PSF • Additional details and full list of approved components can be found Here. #5003807 © 2020 IRONRIDGE, INC. VERSION 3.0 FLUSH MOUNT INSTALLATION MANUAL - 4 COMPONeNTS BONDING HARDWARe TORQUe VALUeS Please refer to each attachment's individual section for full details on all torque values and instructions. ☐Bonded Splice Screws (5/16" Socket): 20 in-lbs ☐Universal Fastening Object (7/16" Socket): 80 in-lbs ☐Grounding Lug Nuts (7/16" Socket): 80 in-lbs ☐Grounding Lug Terminal Screws (7/16" Socket): 20 in-lbs ☐Expansion Joint Nuts (7/16" Socket): 80 in-lbs ☐Microinverter Kit Nuts (7/16" Socket): 80 in-lbs ☐Frameless Module Kit Nuts (7/16" Socket): 80 in-lbs ☐3/8" Bonding Hardware Nuts (7/16" Socket): 250 in-lbs COMPONeNTS Bonded SpliceXR Rail UFO and Stopper Sleeve CAMO Grounding Lug 8" Bonding Jumper Expansion Joint Wire ClipEnd Cap QMPV QBOX 3/8" Bonding HardwareMicroinverter Kit Frameless Module Kit Frameless End/Mid Clamp QMPV Classic Conduit Comp Mount QMPV Composition Conduit Penetration QMPV Tile Conduit Mount QMPV Tile Conduit Penetration PRe-INSTALLATION ☐Verify module compatibility. See Page 21 for info. TOOLS ReQUIReD ☐Cordless Drill (non-impact) ☐Impact Driver (for lag bolts) ☐Torque Wrench (0-250 in-lbs) ☐7/16” Socket ☐1/2" Socket ☐9/16" Socket ☐7/32" Drill bit ☐1/8" Drill bit ☐1/4" Drill bit ☐T30 Bit ☐Channel Lock Pliers ☐#3 Phillips Bit ☐Paddle Bit Ironridge L-Foot BOSS Tech Brief Class A Fire Rating Background All roofing products are tested and classified for their ability to resist fire. Recently, these fire resistance standards were expanded to include solar equipment as part of the roof system. Specifically, this requires the modules, mounting hardware and roof covering to be tested together as a system to ensure they achieve the same fire rating as the original roof covering. These new requirements are being adopted throughout the country in 2016. IronRidge Certification IronRidge was the first company to receive a Class A Fire Rating—the highest possible rating—from Intertek Group plc., a Nationally Recognized Testing Laboratory. IronRidge Flush Mount and Tilt Mount Systems were tested on sloped and flat roofs in accordance with the new UL 1703 & UL 2703 test standards. The testing evaluated the system’s ability to resist flame spread, burning material and structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Rating on your next project. Test Setup Solar Modules Solar modules are given a Type classification based on their materials and construction. Mounting System Mounting is tested as part of a system that includes type-tested modules and fire-rated roof covering. Roof Covering Roof covering products are given a Fire Class Rating of A, B or C based on their tested fire resistance. A burning wooden block is placed on module as a fan blows at 12 mph. Flame cannot be seen on underside of roof within 90 minutes. Burning Brand Test Flame at southern edge of roof is aimed up the roof as a fan blows at 12 mph. The flame cannot spread 6 feet or more in 10 minutes. Spread of Flame Test Fire Testing Process System Roof Slope Module Fire Rating* Flush Mount Any Slope Type 1, 2, & 3 Class A Tilt Mount ≤ 6 Degrees Type 1, 2, & 3 Class A *Class A rated PV systems can be installed on Class A, B, and C roofs. 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com GFT-OP-11a (24-MAR-2014) Tech Brief Simplified Grounding for Every Application The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature the UFO family—Flush Mount, Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. UFO Family of Components Universal Fastening Object (UFO) The UFO securely bonds solar modules to XR Rails. It comes assembled and lubricated, and can fit a wide range of module heights. Stopper Sleeve The Stopper Sleeve snaps onto the UFO, converting it into a bonded end clamp. BOSS™ Splice Bonded Structural Splice connects rails with built-in bonding teeth. No tools or hardware needed. Bonded Attachments The bonding bolt attaches and bonds the L-foot to the rail. It is installed with the same socket as the rest of the system. Grounding Lug A single Grounding Lug connects an entire row of PV modules to the grounding conductor. System Diagram UL Certification The IronRidge Flush Mount, Tilt Mount, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc. UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. © 2020 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.15 Tech Brief Cross-System Compatibility Feature Flush Mount Tilt Mount Ground Mount XR Rails XR1000 Only UFO/Stopper  BOSS™ Splice N/A Grounding Lugs 1 per Row 1 per Row 1 per Array Microinverters & Power Optimizers Enphase - M250-72, M250-60, M215-60, C250-72 Darfon - MIG240, MIG300, G320, G640 SolarEdge - P300, P320, P400, P405, P600, P700, P730 Fire Rating Class A Class A N/A Modules Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. í Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for grounding lugs and field installed equipment ground conductors (EGC). A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. Go to IronRidge.com/UFO Cut Sheet See Description / Length 2.44 .58 1.25 2.34 1.99 .66 .46 APPROVED MATERIALS: 6005-T6, 6005A-T61, 6105-T5, 6N01-T6 (34,000 PSI YIELD STRENGTH MINIMUM) XR100 Rail v1.1 Cut Sheet Rail shown for reference 1 1.24 1.93 0.93 11.00 BONDING SPRING STOP TAB ALIGNMENT CIRCLE 1) Bonded Splice, XR100 ITEM NO DESCRIPTION QTY IN KIT 1 SPLICE, XR100, MILL 1 Part Number Description XR100-BOSS-01-M1 Bonded Splice, XR100 Propery Value Material 6000 Series Aluminum Finish Mill Bonded Splice, XR100 v1.0 Tech Brief Solar, Sleeker Than Ever Most solar installations use mounting rails and fasteners to secure modules to the building structure, but these critical components often protrude from the sides of the modules, giving arrays a coarse look. CAMO is an invisible fastener that secures solar modules flush to rail ends, creating a clean, sleek appearance. CAMO works with nearly all solar modules and installs without tools or torque specifications. It simply rotates into place to structurally secure and electrically bond with the module. Hidden End Cam Certified to comply with International Building Code, ASCE/SEI-7, and UL 2703 Mechanical and Bonding Requirements. Cam-Locking Design CAMO’s unique design allows for a completely tool-less installation. Simply slide CAMO into the rail track and rotate the ergonomic handle 90 degrees to lock onto the module frame. It’s that easy. Standard Fastener © 2018 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.01 Tech Brief Easy, Tool-Less Installation A. PLACE CAMO Slide CAMO into rail track far enough to clear the module frame. CAMO requires 6” of clearance from end of rail. B. PLACE MODULE Place module on rails and align flush with rail ends (module cells not shown in image to provide clarity). The module can overhang the rail no more than 1/4”. C. SLIDE CAMO Pull CAMO towards rail end, at a 45 degree angle, so linear bonding pin contacts the module flange edge. D. SECURE CAMO Rotate handle with an upwards motion until CAMO snaps into rail track. Ensure CAMO bonding pins are fully seated on top of module frame. A Tested & Certified B C D UL 2703 CAMO conforms to STD UL 2703 (2015) requirements and fits modules with bottom flanges that meet specifications shown in the frame compatibility diagram on the left. See IronRidge Installation Manuals for full ratings and a list of certified compatible modules. VARIES VARIES B C A XR Rail Slope Module Mounting System Bonding Mid Clamp DETAIL C (Module Removed for Clarity) Module Mounting System Bonding End Clamp (CAMO) Module Mounting System Bonding End Clamp (UFO) DETAIL A XR Rail EXHIBIT: EX-0015 - page 1 of 3 05/25/2018 PLAN VIEW DETAIL B FLUSH MOUNT SYSTEM PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF IRONRIDGE INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF IRONRIDGE INC. IS PROHIBITED. WEIGHT: N/A SHEET 1 OF 3 --DWG. NO.SIZE SCALE: NTS EX-0015 0.4 X L ( MAX) 0.4 X L ( MAX) (L) Span GE F D Existing Roof Structure CL CL DETAIL G Module Mounting SystemBonding End Clamp (UFO) PV Module 3/8" Module Gap (TYP) DETAIL E Module Mounting SystemBonding Mid Clamp PV ModulePV Module DETAIL F Roofing Framing(By Others)Flashing(FlashFoot2 Shown for Reference) Roofing(By Others) PV Module PV Module Rail Attachment(FlashFoot2 CapShown for Reference)XR Rail DETAIL D(Module Removed For Clarity) Module Mounting SystemBonding End Clamp (CAMO) XR Rail EXHIBIT: EX-0015- page 2 of 3 05/25/2018 PLAN VIEW FLUSH MOUNT SYSTEM PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF IRONRIDGE INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF IRONRIDGE INC. IS PROHIBITED. WEIGHT: N/A SHEET 2 OF 3 --DWG. NO.SIZE SCALE: NTS EX-0015 H DETAIL H Rail Attachment(FlashFoot2 Cap Shown for Reference) Flashing(FlashFoot2 Shown for Reference) Roof Framing(By Others) Module Mounting SystemBonding End Clamp (CAMO) Module Mounting System Bonding Mid Clamp XR Rail Options, TYP: 3/8" Bolt and Nut, (TYP) Roof Panels(By Others) Roof Covering (Shown for Reference) Module Mounting SystemBonding End Clamp (UFO) OR 3.0 2.4 1.8 XR10 XR100 XR1000 EXHIBIT: EX-0015 - page 3 of 3 05/25/2018 FLUSH MOUNT SYSTEM PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF IRONRIDGE INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF IRONRIDGE INC. IS PROHIBITED. WEIGHT: N/A SHEET 3 OF 3 --DWG. NO.SIZE SCALE: NTS EX-0015 February 18, 2021 IronRidge, Inc 28357 Industrial Blvd. Hayward, CA 94545 TEL: (800) 227-9523 Attn.: Engineering Department, Re: Engineering Certification for the IronRidge XR-100 Flush Mount System Span Tables. This letter is to document that PZSE, Inc.-Structural Engineers has reviewed the Methods used to compute the IronRidge XR-100 Flush Mount System span tables. SCOPE OF THE SYSTEM: The XR-100 Flush Mount System is a solar panel support system for installing solar photovoltaic arrays on Gable and Hip roofs, slopes of 8o to 45o. Spans can vary depending on various site-specific criteria including, but not limited to, roof slope and environmental loading. SCOPE OF OUR REVIEW: PZSE, Inc.–Structural Engineers provided a review of the following  IronRidge XR-100 Flush Mount System design methodology  IronRidge XR-100 Flush Mount System Span Tables  IronRidge XR-100 Flush Mount System Typical Installation and has determined that all information, data, and analysis contained within the “Structural Certification and Span Tables for the IronRidge Flush Mount System” sealed by Gang Xuan PE, SE, dated December 31, 2019, comply with the structural requirements of the following Reference Documents:  Minimum Design Loads for Buildings and Other Structures, ASCE/SEI 7-16  International Building Code, 2018 Edition, by International Code Council, Inc.  Aluminum Design Manual, 2015 Editions, by The Aluminum Association This letter certifies that the IronRidge XR-100 Flush Mount System complies with the above Reference Documents. DESIGN RESPONSIBILITY: The IronRidge XR-100 Flush Mount System is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, the user of the Structural Certification and Span Tables for the IronRidge Flush Mount System has sole responsibility for the accuracy of the design and integrity of the system. The Structural Certification and Span Tables for the IronRidge Flush Mount System does not check the capacity of the building structure to support the loads imposed on the building by the array, such as the bending strength of the roof rafters spanning between supports. This requires additional knowledge of the building and is outside the scope of the Installation Manual and our review. If you have any questions on the above, do not hesitate to call. Prepared By: PZSE, Inc. - Structural Engineers Roseville, CA DIGITAL SIGNATURE REE NI REHCAZK.LUAP GNELANOISSEFORP 2762 FOETAT S OHADI DESNECIL EXP. 08/31/2022 © 2019 IronRidge, Inc. CA Flush Mount System Certification Letter - 1 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com Attn: Corey Geiger, COO, IronRidge Inc. Date: December 31st, 2019 Re: Structural Certification and Span Tables for the IronRidge Flush Mount System This letter addresses the structural performance and code compliance of IronRidge’s Flush Mount System. The contents of the letter shall be read in its entirety before applying to any project design. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof attachment with 3/8” stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are shown in Exhibit EX-0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards listed below, for the load conditions and configurations tabulated in the attached span tables. • ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures (ASCE 7-16) • 2018 International Building Code (IBC-2018) • 2019 California Building Code (CBC-2019) • 2015 Aluminum Design Manual (ADM-2015) The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones provided in ASCE 7-16 for gable & hip roof profiles, and roof slopes of 8° to 45°. The tabulated spans are applicable when the following conditions are met: 1. Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener). 2. The underlying roof pitch, measured between the roof surface and horizontal plane, is 45° or less. 3. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 4. A clearance from the underside of the array to the roof surface of 2” minimum shall be provided and the height of the array, the distance from the module top surface to the roof surface (defined as h2), shall not exceed 10”. 5. Module length and area shall not exceed the maximum values listed on the respective span tables. 6. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge’s Flush Mount Installation Manual and other applicable standards for the general roof construction practice. © 2019 IronRidge, Inc. CA Flush Mount System Certification Letter - 2 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com The parameters and adjustments allowed in the span tables are defined as the following: 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1.5-1. 2. Wind speed shall conform to ASCE 7-16 Fig. 26.5-1B (for Risk Category II) and applicable state & local county/city amendments to the IBC. No special wind topographic features are included and both topographic coefficient (Kzt) and wind ground elevation factor (Ke) are taken as 1.0. 3. Snow load used in the span tables is the ground snow and shall conform to ASCE 7-16 Fig. 7.2-1 and applicable state & local county/city amendments to the IBC. If the local jurisdiction specified snow load is in the format of a flat roof snow, it shall first be converted to a ground snow following the local building code/ amendments before the application of the attached span tables. No special snow conditions are considered including unbalanced, drifting, sliding, retention, or ponding snow. No rain-on-snow surcharge load is considered. The span tables do not apply to buildings which are intentionally kept below freezing, kept just above freezing, or unheated. 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: (a) For ground snow no greater than 42psf: S s ≤ 2.0g for Site Class A, B, C, & D. (b) For ground snow greater than 65psf: S s ≤ 1.0g for Site Class A, B, C, & D. (c) For ground snow between 42 and 65psf: S s ≤ 1.5g for Site Class A, B, C, & D. 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-2I and are organized into three groups in which the zones share the same External Pressure Coefficients (GCp). Roof zones comprising each group along with each roof zone’s size and location are depicted in Figures 2 and 3 below each span table. 6. The maximum rail cantilever length, measured from the rail end to the nearest attachment point, shall be the lesser of the following two conditions: 40% of the allowable span provided for the respective load & configuration condition from the span tables, or 36”. 7. Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over a minimum of three spans. 8. No rail splices are allowed in the cantilever, outer 2/3 of end spans, or middle 1/3 of interior spans. 9. Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded. If such conditions are encountered contact support@ironridge.com. 10. Systems using CAMO module clamps shall be installed with the following guidance: a) For single module installations (orphan modules) using modules with a length greater than 67.5”, CAMO clamps shall not be installed in regions that experience ground snow loads of 70psf and greater. Such scenarios are shown by asterisks in the applicable span tables. b) CAMO will function within a module’s design load ratings. Be sure the specific module being used with CAMO meets the dimensional requirements shown in the figure below and that the module selected is suitable for the environmental conditions of a particular project. Figure 1: CAMO Module Frame Dimensional Requirements © 2019 IronRidge, Inc. CA Flush Mount System Certification Letter - 4 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. Sincerely, Gang Xuan, SE Senior Structural Engineer Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 8-20 123 123 123 102 102 102 86 86 86 84 84 84 75 75 75 68 68 68 64 64 64 58 58 58 55 55 55 52 52 52 49 49 49 48 48 48 45 45 45 124 120 107 106 87 79 21-27 121 121 121 99 99 99 84 84 84 83 83 83 76 76 76 69 69 69 64 64 64 59 59 59 56 56 56 53 53 53 50 50 50 48 48 48 48 48 48 121 121 121 113 96 88 28-45 117 117 117 98 98 98 83 83 83 82 82 82 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 117 117 117 110 99 90 8-20 123 123 123 102 102 102 86 86 86 84 84 84 75 75 75 68 68 68 64 64 64 58 58 58 55 55 55 52 52 52 49 49 49 48 48 48 45 45 45 124 112 99 99 82 74 21-27 121 121 121 99 99 99 84 84 84 83 83 83 76 76 76 69 69 69 64 64 64 59 59 59 56 56 56 53 53 53 50 50 50 48 48 48 48 48 48 121 120 113 107 88 83 28-45 117 117 117 98 98 98 83 83 83 82 82 82 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 117 117 110 104 96 85 8-20 123 123 122 102 102 102 86 86 86 84 84 84 75 75 75 68 68 68 64 64 64 58 58 58 55 55 55 52 52 52 49 49 49 48 48 48 45 45 45 124 103 92 92 77 72 21-27 121 121 121 99 99 99 84 84 84 83 83 83 76 76 76 69 69 69 64 64 64 59 59 59 56 56 56 53 53 53 50 50 50 48 48 48 48 48 48 121 112 106 101 84 78 28-45 117 117 117 98 98 98 83 83 83 82 82 82 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 117 117 104 99 90 81 8-20 123 123 114 102 102 102 86 86 86 84 84 84 75 75 75 68 68 68 64 64 64 58 58 58 55 55 55 52 52 52 49 49 49 48 48 48 45 45 45 124 97 87 86 73 66 21-27 121 121 121 99 99 99 84 84 84 83 83 83 76 76 76 69 69 69 64 64 64 59 59 59 56 56 56 53 53 53 50 50 50 48 48 48 48 48 48 121 106 99 96 79 74 28-45 117 117 117 98 98 98 83 83 83 82 82 82 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 117 111 99 96 85 77 8-20 123 120 107 102 102 102 86 86 86 84 84 84 75 75 75 68 68 68 64 64 64 58 58 58 55 55 55 52 52 52 49 49 49 48 48 48 45 45 45 119 91 81 81 69 64 21-27 121 121 121 99 99 99 84 84 84 83 83 83 76 76 76 69 69 69 64 64 64 59 59 59 56 56 56 53 53 53 50 50 50 48 48 48 48 48 48 121 99 93 92 76 72 28-45 117 117 117 98 98 98 83 83 83 82 82 82 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 117 105 96 90 81 73 8-20 123 113 101 102 102 101 86 86 86 84 84 84 75 75 75 68 68 68 64 64 64 58 58 58 55 55 55 52 52 52 49 49 49 48 48 48 45 45 45 109 86 76 76 66 59 21-27 121 121 115 99 99 99 84 84 84 83 83 83 76 76 76 69 69 69 64 64 64 59 59 59 56 56 56 53 53 53 50 50 50 48 48 48 48 48 48 117 96 88 87 72 67 28-45 117 117 112 98 98 98 83 83 83 82 82 82 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 113 100 89 85 78 72 8-20 123 107 96 102 102 96 86 86 86 84 84 84 75 75 75 68 68 68 64 64 64 58 58 58 55 55 55 52 52 52 49 49 49 48 48 48 45 45 45 102 81 72 72 64 54 21-27 121 115 109 99 99 99 84 84 84 83 83 83 76 76 76 69 69 69 64 64 64 59 59 59 56 56 56 53 53 53 50 50 50 48 48 48 48 48 48 111 89 83 84 69 64 28-45 117 117 106 98 98 98 83 83 83 82 82 82 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 108 96 85 81 74 67 8-20 123 96 85 102 96 85 86 86 85 84 84 84 75 75 75 68 68 68 64 64 64 58 58 58 55 55 55 52 52 52 49 49 49 48 48 48 45 45 45 90 73 65 67 55 44 21-27 121 104 98 99 99 98 84 84 84 83 83 83 76 76 76 69 69 69 64 64 64 59 59 59 56 56 56 53 53 53 50 50 50 48 48 48 48 48 48 101 80 74 77 64 58 28-45 117 109 98 98 98 98 83 83 83 82 82 82 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 98 87 77 75 69 61 8-20 110 87 77 102 87 77 86 86 77 84 84 77 75 75 75 68 68 68 64 64 64 58 58 58 55 55 55 52 52 52 49 49 49 48 48 48 45 45 45 78 66 59 64 45 36 21-27 118 96 88 99 96 88 84 84 84 83 83 83 76 76 76 69 69 69 64 64 64 59 59 59 56 56 56 53 53 53 50 50 50 48 48 48 48 48 48 92 73 67 72 58 48 28-45 113 101 90 98 98 90 83 83 83 82 82 82 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 90 80 72 69 64 56 8-20 98 79 72 98 79 72 86 79 72 84 79 72 75 75 72 68 68 68 64 64 64 58 58 58 55 55 55 52 52 52 49 49 49 48 48 48 45 45 45 72 60 45 57 38 32 21-27 108 87 80 99 87 80 84 84 80 83 83 80 76 76 76 69 69 69 64 64 64 59 59 59 56 56 56 53 53 53 50 50 50 48 48 48 48 48 48 84 67 61 66 48 38 28-45 105 96 83 98 96 83 83 83 83 82 82 82 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 82 74 65 64 59 48 8-20 88 72 65 88 72 65 86 72 65 84 72 65 75 72 65 68 68 65 64 64 64 58 58 58 55 55 55 52 52 52 49 49 49 48 48 48 45 45 45 66 49 36 50 33 27 21-27 100 80 74 99 80 74 84 80 74 83 80 74 76 76 74 69 69 69 64 64 64 59 59 59 56 56 56 53 53 53 50 50 50 48 48 48 48 48 48 78 64 52 64 41 33 28-45 97 87 77 97 87 77 83 83 77 82 82 77 76 76 76 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 76 69 60 59 54 40 8-20 80 67 59 80 67 59 80 67 59 80 67 59 75 67 59 68 67 59 64 64 59 58 58 58 55 55 55 52 52 52 49 49 49 48 48 48 45 45 45 64 40 32 44 29 24 21-27 93 74 68 93 74 68 84 74 68 83 74 68 76 74 68 69 69 68 64 64 64 59 59 59 56 56 56 53 53 53 50 50 50 48 48 48 48 48 48 72 55 41 59 35 27 28-45 90 81 72 90 81 72 83 81 72 82 81 72 76 76 72 72 72 72 67 67 67 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 72 64 54 54 45 34 8-20 77 64 55 77 64 55 77 64 55 77 64 55 75 64 55 68 64 55 64 64 55 58 58 55 55 55 55 52 52 52 49 49 49 48 48 48 45 45 45 60 36 30 42 27 24 21-27 90 72 65 90 72 65 84 72 65 83 72 65 76 72 65 69 69 65 64 64 64 59 59 59 56 56 56 53 53 53 50 50 50 48 48 48 48 48 48 72 49 37 56 33 26 28-45 87 78 69 87 78 69 83 78 69 82 78 69 76 76 69 72 72 69 66 66 66 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 67 64 48 49 42 32 8-20 73 64 48 73 64 48 73 64 48 73 64 48 73 64 48 68 64 48 64 64 48 58 58 48 55 55 48 52 52 48 49 49 48 48 48 48 45 45 45 57 34 28 39 26 21 21-27 87 69 64 87 69 64 84 69 64 83 69 64 76 69 64 69 69 64 64 64 64 59 59 59 56 56 56 53 53 53 50 50 50 48 48 48 48 48 48 68 44 33 53 32 24 28-45 84 76 67 84 76 67 83 76 67 81 76 67 75 75 67 72 72 67 66 66 66 64 64 64 59 59 59 56 56 56 53 53 53 51 51 51 49 49 49 65 59 44 48 40 30 = min 72" span = min 64" span = min 48" span *= Note: additional installation requirement for CAMO module clamp. See Note 10 on Page 2 for details.REV 12/12/2019 = Shaded cells indicate conditions in which UFO Mid Clamp connection capacity is exceeded. See Note 9 on page 2 for details. Rail: XR100 Gable Roof Flush Mount System Span Table (inches) - Portrait or Landscape Installation Max Module Length: 80" (72 cell typ.), Max Module SF: 24 SF Exposure B Wind Speed (mph) Roof Slope (deg.) Ground Snow: 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 120 psf*Exposed Mod.Edge Mod.100 psf*110 psf* 100 mph 60 psf 70 psf*80 psf*90 psf* 90 mph 95 mph 105 mph 110 mph 115 mph 120 mph 130 mph 180 mph 140 mph 150 mph 160 mph 170 mph 175 mph • NYSE-listed since 2010, Bloomberg Tier 1 manufacturer • Best-selling panel globally for last 4 years • Top performance in the strictest 3rd party labs • 99.9% on-time delivery to the installer • Premium solar panel factories in USA and Malaysia EAGLE 66TR G4 370-390 WATT TILING RIBBON MODULE Positive power tolerance of 0~+3% KEY FEATURES BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US SOLAR BRAND THE MOST DEPENDABLE TR Technology Tiling Ribbon eliminates cell gaps to increase module efficiency and power. 9BB Half Cell Technology Uniquely designed 9 busbar half cut solar cells deliver ultra-high power in a small footprint. Shade Tolerant Twin array design allows continued performance even with shading by trees or debris. Designed for Long Life Uses the same DuPont protective film as the Space Station, Mars Lander, and jetliners. Leading Warranty 12-year product and 25-year linear power warranty; 98% guaranteed first year, max 0.55% annual loss. 25 ENGINEERING DRAWINGS PACKAGING CONFIGURATION TEMPERATURE CHARACTERISTICS MAXIMUM RATINGS MECHANICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS No. of Cells 132 (2x66) Dimensions 1855x1029x35mm (73.03×40.51×1.37 in) Weight 21.5 kg (47.40 lbs) Front Glass 3.2mm, Anti-Reflection Coating High Transmission, Low Iron, Tempered Glass Frame Anodized Aluminum Alloy Junction Box IP67 Rated Output Cables 12 AWG, 2053mm (80.83in) or Customized Length Connector MC4 Fire Type Type 1 Pressure Rating 5400Pa (Snow) & 2400Pa (Wind) 2 pallets = 1 stack; 31pcs/pallets, 62pcs/stack, 744pcs/ 40’HQ Container Temperature Coefficients of Pmax -0.35%/°C Temperature Coefficients of Voc -0.28%/°C Temperature Coefficients of Isc 0.048%/°C Nominal Operating Cell Temperature (NOCT)45 ± 2°C Operating Temperature (°C)-40°C~+85°C Maximum System Voltage 1000VDC Maximum Series Fuse Rating 20A Module Type JKM370M-6RL3-B JKM375M-6RL3-B JKM380M-6RL3-B JKM385M-6RL3-B JKM390M-6RL3-B STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT Maximum Power (Pmax)370Wp 275Wp 375Wp 279Wp 380Wp 283Wp 385Wp 286Wp 390Wp 290Wp Maximum Power Voltage (Vmp)36.71V 33.49V 36.80V 33.57V 36.90V 33.70V 37.02V 33.90V 37.15V 34.02V Maximum Power Current (Imp)10.08A 8.22A 10.19A 8.31A 10.30A 8.39A 10.40A 8.45A 10.50A 8.53A Open-circuit Voltage (Voc)44.02V 41.55V 44.12V 41.64V 44.22V 41.74V 44.34V 41.85V 44.47V 41.97V Short-circuit Current (lsc)10.90A 8.80A 11.01A 8.89A 11.12A 8.98A 11.22A 9.06A 11.32A 9.14A Module Efficiency STC (%)19.38%19.65%19.91%20.17%20.43% ELECTRICAL PERFORMANCE & TEMPERATURE DEPENDENCE BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US *STC: Irradiance 1000W/m2 NOCT: Irradiance 800W/m2 *Power measurement tolerance: +/- 3% Cell Temperature 25°C Ambient Temperature 20°C AM = 1.5 AM = 1.5 Wind Speed 1m/s The company reserves the final right for explanation on any of the information presented hereby. JKM370-390M-6RL3-B-A1-US Voltage (V) Temperature Dependence of Isc, Voc, Pmax Current-Voltage & Power-Voltage Curves (390W) Front Side Back Length: +/- 2mm Width: +/- 2mm Height: +/- 1mm Row Pitch: +/- 2mm Cell Temperature (°C) • ISO9001:2008 Quality Standards • ISO14001:2004 Environmental Standards • IEC61215, IEC61730 certified products • UL61730 Certification • ISO45001:2018 Occupational Health & Safety Standards 25-Year Performance Warranty KEY FEATURESLINEAR PERFORMANCE WARRANTY Diamond Half Cell Technology World-record breaking efficient mono PERC half cut solar cells deliver high power in a small footprint. Designed for Long Life Uses the same DuPont protective film as the Space Station, Mars Lander, and jetliners. 25-year warranty. Shade Tolerant Twin array design allows continued performance even with shading by trees or debris. Power Boost in Cloudy Conditions A special film diffuses light, boosting performance even without direct sunlight. Protected Against All Environments Certified to withstand humidity, heat, rain, marine environments, wind, hailstorms, and packed snow. BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US • NYSE-listed since 2010, Bloomberg Tier 1 manufacturer • Best-selling panel globally for last 4 years • Top performance in the strictest 3rd party labs • 99.9% on-time delivery to the installer • Automated manufacturing utilizing artificial intelligence • Vertically integrated, tight controls on quality • Premium solar assembly in USA and Malaysia EAGLE 60HM G2 310-330 WATT • HALF CELL MONO PERC MODULE Positive power tolerance of 0~+3% • ISO9001:2008 Quality Standards • ISO14001:2004 Environmental Standards • IEC61215, IEC61730 certified products • OHSAS18001 Occupational Health & Safety Standards • UL1703 certified products SOLAR BRAND THE MOST DEPENDABLE Years 1 5 10 15 20 25Guaranteed power performance97.5% 83.1% 100% 60% 40% 20% 0% Nomenclature: JKM330M - 60HBL Code Cell Code Backsheet Code Cell null Full null White null Normal H Half B Black L Diamond 25-Year Performance Warranty KEY FEATURESLINEAR PERFORMANCE WARRANTY Diamond Half Cell Technology World-record breaking efficient mono PERC half cut solar cells deliver high power in a small footprint. Designed for Long Life Uses the same DuPont protective film as the Space Station, Mars Lander, and jetliners. 25-year warranty. Shade Tolerant Twin array design allows continued performance even with shading by trees or debris. Power Boost in Cloudy Conditions A special film diffuses light, boosting performance even without direct sunlight. Protected Against All Environments Certified to withstand humidity, heat, rain, marine environments, wind, hailstorms, and packed snow. BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US • NYSE-listed since 2010, Bloomberg Tier 1 manufacturer • Best-selling panel globally for last 4 years • Top performance in the strictest 3rd party labs • 99.9% on-time delivery to the installer • Automated manufacturing utilizing artificial intelligence • Vertically integrated, tight controls on quality • Premium solar assembly in USA and Malaysia EAGLE 60HM G2 310-330 WATT • HALF CELL MONO PERC MODULE Positive power tolerance of 0~+3% • ISO9001:2008 Quality Standards • ISO14001:2004 Environmental Standards • IEC61215, IEC61730 certified products • OHSAS18001 Occupational Health & Safety Standards • UL1703 certified products SOLAR BRAND THE MOST DEPENDABLE Years 1 5 10 15 20 25Guaranteed power performance97.5% 83.1% 100% 60% 40% 20% 0% Nomenclature: JKM330M - 60HBL Code Cell Code Backsheet Code Cell null Full null White null Normal H Half B Black L Diamond The company reserves the final right for explanation on any of the information presented hereby. TR JKM380-400M-6RL3-B-A2-EN-F35 (IEC2016) Engineering Drawings SPECIFICATIONS Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5STC: Irradiance 800W/m 2 AM=1.5NOCT: Power measurement tolerance: ± 3%* * Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature(℃) Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C Temperature Dependence of Isc,Voc,Pmax -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax Current-Voltage & Power-Voltage Curves (380W) 5 10 15 20 25 30 35 40 45 500 0 2 4 6 8 10 12 0 70 140 210 350 280 420 STC NOCTSTC NOCT TCONCTS -40℃~+85℃ 1000VDC (IEC) 20A 0~+3% -0.35%/℃ -0.28%/℃ 0.048%/℃ 45±2℃ TCONCTS 20.17% 385Wp 37.02V 10.40A 44.34V 11.22A 286Wp 8.45A 33.90V 41.85V 9.06A JKM385M-6RL3-B JKM390M-6RL3-B JKM395M-6RL3-B JKM400M-6RL3-B 20.43% 390Wp 37.15V 10.50A 44.47V 11.32A 290Wp 8.53A 34.02V 41.97V 9.14A 20.69% 395Wp 37.27V 10.60A 44.59V 11.42A 294Wp 8.61A 34.13V 42.09V 9.22A 20.96% 400Wp 37.39V 10.70A 44.71V 11.52A 298Wp 8.69A 34.25V 42.20V 9.30A STC NOCT JKM380M-6RL3-B 19.91% 380Wp 36.90V 10.30A 44.22V 11.12A 283Wp 8.39A 33.70V 41.74V 8.98A1855mm (73.03")1029 mm (40.51") A A H 1360mm (53.54")860mm (33.86")981mm (38.62")3535 R4. 5 149 Lenth: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm Packaging Configuration ( Two pallets = One stack ) 31pcs/pallets, 62pcs/stack, 744pcs/ 40'HQ Container Mechanical Characteristics Cell Type No.of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22.1kg (48.72 lbs) IP67 Rated TUV 1×4.0mm2 (+): 290mm , (-): 145 mm or Customized Length 3.2mm,Anti-Reflection Coating, High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1855×1029×35mm (73.03×40.51×1.37 inch) 132 (2×66) P type Mono-crystalline 35 35 C CB B A The company reserves the final right for explanation on any of the information presented hereby. TR JKM380-400M-6RL3-B-A2-EN-F35 (IEC2016) Engineering Drawings SPECIFICATIONS Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5STC: Irradiance 800W/m 2 AM=1.5NOCT: Power measurement tolerance: ± 3%* * Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature(℃) Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C Temperature Dependence of Isc,Voc,Pmax -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax Current-Voltage & Power-Voltage Curves (380W) 5 10 15 20 25 30 35 40 45 500 0 2 4 6 8 10 12 0 70 140 210 350 280 420 STC NOCTSTC NOCT TCONCTS -40℃~+85℃ 1000VDC (IEC) 20A 0~+3% -0.35%/℃ -0.28%/℃ 0.048%/℃ 45±2℃ TCONCTS 20.17% 385Wp 37.02V 10.40A 44.34V 11.22A 286Wp 8.45A 33.90V 41.85V 9.06A JKM385M-6RL3-B JKM390M-6RL3-B JKM395M-6RL3-B JKM400M-6RL3-B 20.43% 390Wp 37.15V 10.50A 44.47V 11.32A 290Wp 8.53A 34.02V 41.97V 9.14A 20.69% 395Wp 37.27V 10.60A 44.59V 11.42A 294Wp 8.61A 34.13V 42.09V 9.22A 20.96% 400Wp 37.39V 10.70A 44.71V 11.52A 298Wp 8.69A 34.25V 42.20V 9.30A STC NOCT JKM380M-6RL3-B 19.91% 380Wp 36.90V 10.30A 44.22V 11.12A 283Wp 8.39A 33.70V 41.74V 8.98A1855mm (73.03")1029 mm (40.51") A A H 1360mm (53.54")860mm (33.86")979mm (38.54")3535 R4. 5 149 Lenth: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm Packaging Configuration ( Two pallets = One stack ) 31pcs/pallets, 62pcs/stack, 744pcs/ 40'HQ Container Mechanical Characteristics Cell Type No.of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22.1kg (48.72 lbs) IP67 Rated TUV 1×4.0mm2 (+): 290mm , (-): 145 mm or Customized Length 3.2mm,Anti-Reflection Coating, High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1855×1029×35mm (73.03×40.51×1.37 inch) 132 (2×66) P type Mono-crystalline The company reserves the final right for explanation on any of the information presented hereby. TR JKM380-400M-6RL3-B-A2-EN-F35 (IEC2016) Engineering Drawings SPECIFICATIONS Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5STC: Irradiance 800W/m 2 AM=1.5NOCT: Power measurement tolerance: ± 3%* * Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature(℃) Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C Temperature Dependence of Isc,Voc,Pmax -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax Current-Voltage & Power-Voltage Curves (380W) 5 10 15 20 25 30 35 40 45 500 0 2 4 6 8 10 12 0 70 140 210 350 280 420 STC NOCTSTC NOCT TCONCTS -40℃~+85℃ 1000VDC (IEC) 20A 0~+3% -0.35%/℃ -0.28%/℃ 0.048%/℃ 45±2℃ TCONCTS 20.17% 385Wp 37.02V 10.40A 44.34V 11.22A 286Wp 8.45A 33.90V 41.85V 9.06A JKM385M-6RL3-B JKM390M-6RL3-B JKM395M-6RL3-B JKM400M-6RL3-B 20.43% 390Wp 37.15V 10.50A 44.47V 11.32A 290Wp 8.53A 34.02V 41.97V 9.14A 20.69% 395Wp 37.27V 10.60A 44.59V 11.42A 294Wp 8.61A 34.13V 42.09V 9.22A 20.96% 400Wp 37.39V 10.70A 44.71V 11.52A 298Wp 8.69A 34.25V 42.20V 9.30A STC NOCT JKM380M-6RL3-B 19.91% 380Wp 36.90V 10.30A 44.22V 11.12A 283Wp 8.39A 33.70V 41.74V 8.98A1855mm (73.03")1029 mm (40.51") A A H 1360mm (53.54")860mm (33.86")979mm (38.54")3535 R4. 5 149 Lenth: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm Packaging Configuration ( Two pallets = One stack ) 31pcs/pallets, 62pcs/stack, 744pcs/ 40'HQ Container Mechanical Characteristics Cell Type No.of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22.1kg (48.72 lbs) IP67 Rated TUV 1×4.0mm2 (+): 290mm , (-): 145 mm or Customized Length 3.2mm,Anti-Reflection Coating, High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1855×1029×35mm (73.03×40.51×1.37 inch) 132 (2×66) P type Mono-crystalline The company reserves the final right for explanation on any of the information presented hereby. TR JKM380-400M-6RL3-B-A2-EN-F35 (IEC2016) Engineering Drawings SPECIFICATIONS Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5STC: Irradiance 800W/m 2 AM=1.5NOCT: Power measurement tolerance: ± 3%* * Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature(℃) Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C Temperature Dependence of Isc,Voc,Pmax -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax Current-Voltage & Power-Voltage Curves (380W) 5 10 15 20 25 30 35 40 45 500 0 2 4 6 8 10 12 0 70 140 210 350 280 420 STC NOCTSTC NOCT TCONCTS -40℃~+85℃ 1000VDC (IEC) 20A 0~+3% -0.35%/℃ -0.28%/℃ 0.048%/℃ 45±2℃ TCONCTS 20.17% 385Wp 37.02V 10.40A 44.34V 11.22A 286Wp 8.45A 33.90V 41.85V 9.06A JKM385M-6RL3-B JKM390M-6RL3-B JKM395M-6RL3-B JKM400M-6RL3-B 20.43% 390Wp 37.15V 10.50A 44.47V 11.32A 290Wp 8.53A 34.02V 41.97V 9.14A 20.69% 395Wp 37.27V 10.60A 44.59V 11.42A 294Wp 8.61A 34.13V 42.09V 9.22A 20.96% 400Wp 37.39V 10.70A 44.71V 11.52A 298Wp 8.69A 34.25V 42.20V 9.30A STC NOCT JKM380M-6RL3-B 19.91% 380Wp 36.90V 10.30A 44.22V 11.12A 283Wp 8.39A 33.70V 41.74V 8.98A1855mm (73.03")1029 mm (40.51") A A H 1360mm (53.54")860mm (33.86")981mm (38.62")3535 R4. 5 149 Lenth: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm Packaging Configuration ( Two pallets = One stack ) 31pcs/pallets, 62pcs/stack, 744pcs/ 40'HQ Container Mechanical Characteristics Cell Type No.of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22.1kg (48.72 lbs) IP67 Rated TUV 1×4.0mm2 (+): 290mm , (-): 145 mm or Customized Length 3.2mm,Anti-Reflection Coating, High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1855×1029×35mm (73.03×40.51×1.37 inch) 132 (2×66) P type Mono-crystalline 35 35 C CB B A 2XWGRRU3KRWRYROWDLF(QFORVXUHV6HULHV (7/OLVWHGDQGODEHOHG 5HSRUW357-5HYLVHG0D\ · 8/7\SH5(GLWLRQ(OHFWULFDOHTXLSPHQWHQFORVXUHV · &6$&1R1HPD7\SH5 · &RQIRUPVWR8/6WDQGDUG · 9'&DPSV · 9$&DPSV · \HDUOLPLWHGZDUUDQW\ &RPSRVLWLRQ&HGDU5RRI6\VWHP %DVLF6SHFLILFDWLRQV 0DWHULDORSWLRQV · 3RZGHUFRDWHGJDXJHJDOYDQL]HGVWHHO  KRXUVVDOWVSUD\ · 6WDLQOHVVVWHHO 3URFHVV-6HDPOHVVGUDZ VWDPSHG )ODVKLQJ-´[´ +HLJKW-´ &DYLW\-&XELFLQFKHV $SSUR[LPDWHZHLJKW-OE %DVH3ODWH · )DVWHQHGWREDVHXVLQJWRJJOHIDVWHQLQJV\VWHP · URRIGHFNNQRFNRXWV · .QRFNRXWVL]HV  ´  ´DQG  ´ · ´PPVORWWHGGLQUDLO · *URXQG%ORFN DŽĚĞůƐĂǀĂŝůĂďůĞŝŶ'ƌĞLJ͕ůĂĐŬŽƌ^ƚĂŝŶůĞƐƐ^ƚĞĞů ^ŽůĂĞĐŬϬϳϵϵ-Ϯ^ ^ŽůĂĞĐŬϬϳϵϵ-' 3DVVWKURXJKDQGFRPELQHUNLWVDUHDYDLODEOHIRUHLWKHU $&RU'&DSSOLFDWLRQV ^ŽůĂĞĐŬϬϳϵϵ-ϱ' Ϭϳϵϵ^ĞƌŝĞƐDŽĚĞůƐ 'ƌŽƵŶĚdLJƉĞ 'ƌŽƵŶĚtŝƌĞ^ŝnjĞ Ϭϳϵϵ-Ϯ ϮWŽƐŝƟŽŶ'ƌŽƵŶĚ ϮͬϬ-ϭϰ Ϭϳϵϵ-ϱ ϱWŽƐŝƟŽŶ'ƌŽƵŶĚ ϭϰ-ϲ Ϭϳϵϵ- ƵĂů'ƌŽƵŶĚ ϭϰ-ϴ 567&(QWHUSULVHV,QF (DX&ODLUH:, -- VDOHV#VRODGHFNFRP ϰ ^ŽůĂĞĐŬ/ŶƐƚĂůůĂƟŽŶ/ŶƐƚƌƵĐƟŽŶƐ KEKdWZKt/d,/E^d>>d/KEhEd/>zKh,sZEd/Z/E^dZhd/KE^/E>h/E'tZE/E'^ &ŝŐƵƌĞϭ · ĞƚĞƌŵŝŶĞƚŚĞůŽĐĂƟŽŶĨŽƌƚŚĞ^ŽůĂĞĐŬŽŶƚŚĞƌŽŽĨƐƵƌĨĂĐĞ͘ · hƐĞƚŚĞƚĞŵƉůĂƚĞĨƌŽŵƚŚĞďŽƩŽŵŽĨƚŚĞ^ŽůĂĞĐŬĐĂƌƚŽŶƚŽ ƚƌĂĐĞƚŚĞ^ŽůĂĞĐŬŽŶƚŚĞƐŚŝŶŐůĞƐ͘ &ŝŐƵƌĞϮ · hƐĞĂƉƌLJďĂƌƚŽůŽŽƐĞŶƚŚĞƐŚŝŶŐůĞƐ͕ƚŚĞŶƌĞŵŽǀĞĂŶLJŶĂŝůƐƚŚĂƚ ǁŽƵůĚŝŶƚĞƌĨĞƌĞǁŝƚŚƚŚĞ^ŽůĂĞĐŬŇĂƐŚŝŶŐ͘ΎdŚĞŇĂƐŚŝŶŐǁŝůů ƐůŝĚĞďĞŶĞĂƚŚƚŚĞƐŚŝŶŐůĞƐ͘ · ƵƚƚŚĞƌŽŽĮŶŐŵĂƚĞƌŝĂůƚŽƚŚĞƐŚĂƉĞŽĨƚŚĞƚĞŵƉůĂƚĞ͘ · ZĞŵŽǀĞƚŚĞŬŶŽĐŬŽƵƚƐŶĞĞĚĞĚƚŽƉĞŶĞƚƌĂƚĞƚŚĞƌŽŽĨĚĞĐŬ͘ &ŝŐƵƌĞϯ · ^ůŝĚĞƚŚĞ^ŽůĂĞĐŬŝŶƚŽƉůĂĐĞďĞŶĞĂƚŚƚŚĞƐŚŝŶŐůĞƐĂŶĚŵĂƌŬƚŚĞ ŬŶŽĐŬŽƵƚůŽĐĂƟŽŶƐ͘ · ZĞŵŽǀĞƚŚĞ^ŽůĂĞĐŬĂŶĚĚƌŝůůĂŚŽůĞƚŚƌŽƵŐŚƚŚĞƌŽŽĨĚĞĐŬϭͬϯ ůĂƌŐĞƌƚŚĂŶƚŚĞŬŶŽĐŬŽƵƚŚŽůĞƐ͘ · ĞƚĞƌŵŝŶĞƚŚĞƐŝnjĞĂŶĚŶƵŵďĞƌŽĨĮƫŶŐƐŽƌĐŽŶĚƵŝƚŶĞĞĚĞĚƚŽ ďƌŝŶŐƚŚĞĐŝƌĐƵŝƚŽƌƐƚƌŝŶŐǁŝƌŝŶŐŝŶƚŽƚŚĞ^ŽůĂĞĐŬ͘dŚĞĐŽƌŶĞƌ ĚŝŵƉůĞƐĂůůŽǁƵƉƚŽϭΗĮƫŶŐƐ͕ƚŚĞĐĞŶƚĞƌĚŝŵƉůĞƐĂůůŽǁ͘ϱΗ ĮƫŶŐƐ͘hƐĞĂŬŶŽĐŬŽƵƚƚŽŽůŽƌĚƌŝůůƚŽĐƵƚƚŚĞĮƫŶŐŚŽůĞƐǁŚĞƌĞ ƚŚĞďĂƐĞĚŝŵƉůĞƐĂƌĞůŽĐĂƚĞĚ͘ · /ŶƐƚĂůůƚŚĞĮƫŶŐƐ͕ƌĞƉŽƐŝƟŽŶƚŚĞ^ŽůĂĞĐŬĂŶĚƵƐŝŶŐƚŚĞϭΗƚƌƵƐƐ ŚĞĂĚƐĐƌĞǁƐƉƌŽǀŝĚĞĚĨĂƐƚĞŶƚŚĞ^ŽůĂĞĐŬƚŽƚŚĞƌŽŽĨĚĞĐŬĨƌŽŵ ŝŶƐŝĚĞƚŚĞĞŶĐůŽƐƵƌĞ;ůŽĐĂƟŽŶƐƐŚŽǁŶͿ͘ · hƐĞƌŽŽĨĐĞŵĞŶƚƚŽƐĞĂůƚŚĞƐŚŝŶŐůĞƐƚŽƚŚĞŇĂƐŚŝŶŐΘƌĞƉůĂĐĞ ƌŽŽĨŶĂŝůƐ͘ &ŝŐƵƌĞϰ · /ŶƐƚĂůůĐŽŵƉŽŶĞŶƚƐŶĞĞĚĞĚƚŽĐŽŶŶĞĐƚƚŚĞƐŽůĂƌƉĂŶĞůĐŝƌĐƵŝƚƐ͘ &ŝŐƵƌĞϱ · tŚĞŶĐŽŶŶĞĐƟŽŶƐĂƌĞĐŽŵƉůĞƚĞ͕ĮŶŝƐŚďLJŝŶƐƚĂůůŝŶŐƚŚĞĐŽǀĞƌ ƵƐŝŶŐƚŚĞϴͬϯϮdžϯͬϴΗŚĞdžŚĞĂĚƐĐƌĞǁƐƉƌŽǀŝĚĞĚ͘ &ŝŐƵƌĞϭ &ŝŐƵƌĞϮ &ŝŐƵƌĞϯ &ŝŐƵƌĞϰ &ŝŐƵƌĞϱ 600 Volts. Copper Conductor. Thermoplastic Insulation/Nylon Sheath, Heat, Moisture, Gasoline and Oil Resistant II. All Sizes Rated Both THHN and either THWN (sizes 14, 12, and 10 AWG) or THWN-2 (sizes 8 AWG and larger). Also Rated MTW and AWM (See Below). SIMpull® Technology for Easier Pulling. Southwire® SIMpull THHN® copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 volts. SIMpull THHN® copper conductors are designed to be installed without application of a pulling lubricant. These conductors have multiple ratings. Depending upon the product application, allowable temperatures are as follows: • THHN or T90 Nylon- Dry locations not to exceed 90° C • THWN-2- Wet or dry locations not to exceed 90° C or locations not to exceed 75° C when exposed to oil • THWN- Wet locations not to exceed 75° C or dry locations not to exceed 90° C or locations not to exceed 75° C when exposed to oil • TWN75- Wet locations not to exceed 75° C • MTW- Wet locations or when exposed to oil at temperatures not to exceed 60° C or dry locations not to exceed 90° C (with ampacity limited to that for 75° C conductor temperature per NFPA 79) • AWM- Dry locations not to exceed 105° C only when rated and used as appliance wiring material Southwire® SIMpull THHN® copper conductors comply with the following: • ASTM - B3, B8, and B787 (19 Wire Combination Unilay-Stranded) • UL Standards 83, 758, 1063, and 1581 • CSA C22.2 No. 75, T90 Nylon/TWN75 Sizes through 1000 kcmil • NOM-ANCE 90° C • Federal Specification A-A-59544 • NEMA WC-70 (ICEA S-95-658) Construction Requirements • National Electrical Code, NFPA 70 • CT Rated in Sizes 1/0 AWG and larger • VW-1 - Sizes 14 through 1 AWG • FT1 - All Sizes • Sunlight Resistant – Sizes 2 AWG and larger • AWM - Sizes 14 through 6 AWG • MTW - Stranded Constructions Only • RoHS/REACH Compliant Southwire® SIMpull THHN® copper conductors are made with soft drawn copper. Sizes 14 through 4/0 AWG use a combination-unilay stranding while 250 kcmil and larger sizes use a compressed copper stranding. The wire is covered with a tough heat and moisture resistant PVC insulation with an overall nylon jacket utilizing SIMpull® Technology. Available in black, white, red, blue, purple, green, yellow, orange, brown, and gray. Also available in striped configurations. Some colors are subject to economic order quantity. Marked as THHN in all sizes. Also marked as THWN-2 in sizes 8 AWG and larger or marked as THWN in sizes 14, 12, and 10 AWG. Marked sunlight resistant in sizes 2 AWG and larger. Sizes 14, 12, and 10 AWG are available with SIMpull® Technology only in SIMpull BARREL™ cable drum or SIMpull® CoilPAK™ configurations. APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION SIMpull THHN® Copper THHN Wire & Cable Size (AWG or kcmil)No. of strands 60°C 75°C 90°C 14* 1 15 4 102 15 15 15 15 AC 12* 1 15 4 119 23 20 20 20 AC 10* 1 20 4 150 36 30 30 30 AC 14* 19 15 4 109 16 15 15 15 AC 12* 19 15 4 128 24 20 20 20 AC 10* 19 20 4 161 38 30 30 30 AC 8 19 30 5 213 63 40 50 55 ABCD 6 19 30 5 249 95 55 65 75 ABCD 4 19 40 6 318 152 70 85 100 ABCD 3 19 40 6 346 189 85 100 115 ABCD 2 19 40 6 378 234 95 115 130 ABCD 1 19 50 7 435 299 110 130 145 ABCD 1/0 19 50 7 474 372 125 150 170 ABCD 2/0 19 50 7 518 462 145 175 195 ABCD 3/0 19 50 7 568 575 165 200 225 ABCD 4/0 19 50 7 624 718 195 230 260 ABCD 250 37 60 8 694 851 215 255 290 ABCD 300 37 60 8 747 1012 240 285 320 ABC 350 37 60 8 797 1174 260 310 350 ABC 400 37 60 8 842 1334 280 335 380 ABC 500 37 60 8 926 1655 320 380 430 ABCD 600 61 70 9 1024 1987 350 420 475 ABC 750 61 70 9 1126 2464 400 475 535 BC 1000 61 70 9 1275 3257 455 545 615 C Package Codes: A - 2500' Reel B - 1000' Reel C - 500' Spool D - 5000' Reel * Sizes 14, 12, and 10 AWG are available with SIMpull® Technology only in SIMpull® Barrel or CoilPAK® configurations. Standard put ups vary from the ones shown on this chart for standard 14-10 AWG THHN. +Allowable ampacities shown are for general use as specified by the 2014 Edition of the National Electrical Code Sections 310.15 and 240.4(D). Unless the equipment is marked for use at higher temperatures the conductor shall be limited to the following per NEC 110.14(C): 60° C - When terminated to equipment for circuits rated 100 amperes or less or marked for 14 - 1 AWG conductors. 75° C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90° C - THHN dry locations and THWN-2 wet or dry locations for ampacity adjustment purposes using NEC section 310.15. Standard Package Jacket Thickness (mils) Conductor Insulation Thickness (mils) Nominal O.D. (mils) Approx. Net Wt. Per 1000' (lbs.) Allowable Ampacities+ 4 pv photovoltaiC wire 600 volt • for use in solar power applications • rated 90°C for exposed or concealed wiring in wet or dry locations • rated for direct burial A P P L i C A T i O n S Suitable for use as follows: • Stranded copper conductors • xlp insulation • ul Subject 4703 • ul 44 • ul 854 S P e C i F i C A T i O n S Bare or Tinned Stranded Copper Conductors XLP Insulation Direct Burial -40°C to +90°C 600 Volt • Southwire pv photovoltaic Wire is manufactured using stranded copper conductors with single layer xlp insulation • bare or Tinned Conductors • -40°C to +90°C • Sunlight resistant • rohS Compliant • direct burial • Sample print legend: SouThWIre e316464 (o) (ul) pv WIre 10 AWG (5.26mm2) Cu 600v 90° WeT or dry (-40°C) SuN reS dIreCT burIAl vW-1 or uSe rhW-2 600v — rohS C O n S T R U C T i O n other sizes and strand configurations are available upon request. Also available in various colors. W e i g h T S , M e A S U R e M e n T S A n D P A C k A g i n g SIZe (aWG)nuMBer oF STranDS InSuLaTIon THICKneSS noMInaL o.D.neT WeIGHT 14 19 0.060 0.190 26.8 12 19 0.060 0.207 36.1 10 19 0.060 0.231 50.6 8 19 0.075 0.292 80.3 14 7 0.060 0.190 26.8 12 7 0.060 0.207 36.1 10 7 0.060 0.231 50.6 8 7 0.075 0.292 80.3 STranDeD CoPPer ConDuCTorS Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applicationsDec 04, 2016 1 Product data sheet Characteristics DU221RB SWITCH NOT FUSIBLE GD 240V 30A 2P NEMA3R Product availability : Stock - Normally stocked in distribution facility Price* : 177.00 USD Main Product or component type Single Throw Safety Switch Line Rated Current 30 A Product certifications UL listed NEMA degree of protection NEMA 3R Disconnector device type Non-fusible disconnect Device composition None Device mounting Surface Number of poles 2 Electrical connection Lugs Series name General duty Ordering and shipping details Category 00106 - D & DU SW,NEMA3R, 30-200A Discount Schedule DE1A GTIN 00785901490340 Nbr. of units in pkg.1 Package weight(Lbs)4.8600000000000003 Returnability Y Country of origin MX Contractual warranty Warranty period 18 months