HomeMy WebLinkAboutJOIST - 06-00570 - 350 Oaktrail Dr - New SFRTWORTANT
PLEASE READ AND SIGN THE
ATTACHED SHEET BEFORE
TAILING POSSESION OF YOUR
LAYOUT!
READ BY INTIALS E1
DATE
E1
A complete TJ-Xpert framing plan requires the Trus Joist Framer's Pocket Guide
See Trus Joist Framer's Pocket Guide for Product Trademark Information
I LEVEL NOTES I
File Name: 36 -Jay. Taylor Meissner.JOB
Level Name: Main Level
Plotted: 3/21/2006 15:58
Design Status:
Main Leve 1...3/21/2006 15:55
Roof ......... 3/21/2006 15:55
NOTE: Level design times indicated above provide
assurance for proper level stacking.
Design Methodology: ASD
Floor Area Loading Is:
40psf Live Load and 15 psf Dead Load
Maximum Joist Deflection:
L/480 Live Load
L/240 Total Load
TJ -Pro Rating Information:
Weighted Average: 54
Lowest Rating: 40
Highest Rating: 63
Glued A Nailed Decking is Required
Direct Applied Ceiling is Not Required
Poured Flooring Overlay is Required
Floor Decking: 23/32" Panels (24" Span Rating)
Normal O.C. Spacing a 16"*
*Unless noted otherwise
Scale: 1/8" = V
JOBCOMMENTS
36 -Jay Taylor
Meissner Job
CREATED BY
BML West
P.O. Box 1831
Idaho Falls, ID 83403
(208)557-5056
FAX: (208)529-3610
TJAXP�ert.
I HANGER LIST -Simpson Strong -Tie Company, Inc.®
Plot ID Qty Product Label Top Nails Face Nails Member Nails Notes
Hl 19 IUTll 10-NIO 2-NiO
H2 10 IUTII 10-N10 2-NIO (5)
H3 1 HHUS410 30-10d 10-10d
Hanger Notes:
(5) Backer Blocks
SYMBOL LEGEND
O Point Load
Line Load
Area Load
O Detail Callout Label
(See Framer's Pocket Guide)
Hd-t Header, and -t indicates quantity of 2x_
trimmers required at ends
Required Bearing Length in inches
(Adequate bearing has been provided if
bearing length is not indicated.)
Page 1 of 1
FOR THE TJ-XPERT WARRANTY
SEE FRAMER'S POCKET GUIDE
Preliminary Layout
for Review and Approval
TJ•Xpert 6.42 (#693( C6.42 D6.42 S6.42 P6.42
JOIST AND BEAM LIST
Plot ID
Length
Product
Plies QtY
A26
26'
117/8" TJI 110.1oist
1
5
A24
24'
117/8" TTI 110,1oist
1
11
A20
20'
117/811 TJI 110.1oist
1
9
A18
18'
117/8" TJI 110.iolst
1
1
A16
16'
117/8" TJI 110 joist
1
8
A14
14'
117/811 TJI 110.1oist
1
2
Al2
12'
117/8" TJI 110,1oist
1
14
A6
6'
117/8" TJI 1I0,loist
1
8
A4
4'
117/811 TJI 110 .loist
1
4
MI
14'
13/4" x 117/8" 1.9E Microllam LVL
2
2
M2
8'
1 3/4" x 117/8" 1.9E Microllam LVL
1
1
HEADER LIST
Hdl
18'
13/4" x 117/8" 1.9E Microllam LVL
2
2
ACCESSORIES LIST
Bbl
V
5/8" or 3/4" Backer Blocks
1
20
Rm1
16'
1 I/4" x 117/8" 1.3E Timber5trand LSL
1
13
Ski
V 2 1/4"
It 7/8" TJI 110 Blocking Panels
1
7
Bkl*
4' 3 13/16"
117/811 TJI 110 Blocking Panels
1
1
Sint
4' x 8'
23/32" Panels (24" Span Rating)
1
42
Bk* Random length blocking panel cuts
Bk, Blocking Panels: Rm, Rim Board
SYMBOL LEGEND
O Point Load
Line Load
Area Load
O Detail Callout Label
(See Framer's Pocket Guide)
Hd-t Header, and -t indicates quantity of 2x_
trimmers required at ends
Required Bearing Length in inches
(Adequate bearing has been provided if
bearing length is not indicated.)
Page 1 of 1
FOR THE TJ-XPERT WARRANTY
SEE FRAMER'S POCKET GUIDE
Preliminary Layout
for Review and Approval
TJ•Xpert 6.42 (#693( C6.42 D6.42 S6.42 P6.42