Heating calculation for Malt Haaline, New home 9 817 Hen-tage load, Madison
County., Naha.
As per the REScheck provided by �h� ,con.�ractor the heat �c�ss far the ho -me is figured as
fa�xQws.
UA value: 44 9
Design indoor temp. — 70F
Design outdoor condition = -2Q F
Delta T: 90 F
Heat loss = 40,4 10 BTU
Infiltration value. .75% = 33,675 BTU
Minimum BTU required = 74,085 BTU
It is proposed to install a 1 00,000 BTU furnace with a 4 fan blower.
I,have also included a layout of proposed ductwork sizing and location drawn on blue
prints provided from contractor.