HomeMy WebLinkAboutFA PLAN - 21-00047 - Madison Memorial Hospital - BHU RemodelSHEET:DRAWN BY:CHECKED BY:JOB #:PROJECT #:DESCRIPTIONCADDATEMARKSYSTEM:CHKISSUE DATE:30" x 42" - Arch E1 Size ISSUE LOG:Revisions shown with # symbol ERICA R ANENSONNICET LEVEL III#135963EXISTING SYSTEM SEQUENCE OF OPERATIONSPROJECT DIRECTORYAPPLICABLE CODES & STANDARDSABBREVIATIONS LEGENDGENERAL NOTESLEGENDSDRAWING INDEXDEVICE TAG LEGENDSCOPE OF WORKFIRE ALARM SYSTEMBEHAVIORAL HEALTH-TIMADISON MEMORIAL HOSPITAL·FA: = FACP (NON-NETWORK)·#: = NODE NUMBER·T#: = TRANSPONDER NUMBER·#:T# = NODE:TRANSPONDER NUMBER·N#: = NAC EXTENDER NUMBERDEVICE NUMBER·D# = DOOR HOLDER CIRCUIT NUMBER·F# = FIRE PHONE CIRCUIT·H# = AUDIBLE (HORN) CIRCUIT NUMBER·M# = IDNET LOOP NUMBER·P# = POWER CIRCUIT NUMBER·S# = SPEAKER CIRCUIT NUMBER·V# = VISUAL CIRCUIT NUMBER·Z# = ZONE NUMBER·(L#) = IDNET ISOLATED LOOP NUMBERBRANCH / ISOLATED LOOP DESIGNATOR:CIRCUIT DESIGNATORPANEL DESIGNATOR1:T2:V12-1(L1)1.THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS IS TO BEDETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ONTHE RECORD DRAWINGS.2.SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS INTHE WORK SHOWN, THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SO AS NOT TO IMPAIR THECONSTRUCTION SCHEDULE.3.CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING ASREQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE.ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS.4.A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION.5.THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A BRANCH CIRCUITBREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT CONTROL." THELOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROLUNIT.6.UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO JOHNSON CONTROLS NOLATER THAN 7 DAYS AFTER FINAL TEST.7.THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER.8.DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICAL REPRESENTATIVE.9.ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROMDUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER.10.THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIMETHAT WORK IS NOT ACTIVELY BEING PERFORMED.11.INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWERLIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS ANDAPPLICABLE ELECTRICAL CODES. REFER TO 'APPLICABLE CODES & STANDARDS' FOR SPECIFIC CODE REFERENCES.12.ALL WIRING SHALL BE INSTALLED ACCORDING TO APPLICABLE ELECTRICAL CODES.13.FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIRE ALARM WIRES INACCORDANCE WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE.14FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP.15.FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICALRUNS IN SHAFTS SHALL BE TYPE FPLR.16.FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS.17.FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE APPLICABLEELECTRICAL CODES, WHERE APPLICABLE.18.ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS.19.ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE.20.ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT.21.120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING.22.MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS.23.EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY; HOWEVER, ANY EXISTING CONDUITWILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. JOHNSON CONTROLS MAKES NO STATEMENTS WRITTEN ORVERBAL AS TO THE CONDITION OF EXISTING CONDUITS.PHONE: Sales RepresentativePETER PETRONIPETER.PETRONI@JCI.COM208-914-2099PHONE: Project ManagerSHANE LESTEBERGSHANE.LESTEBERG@JCI.COM208-914-2112PHONE: Drawings Prepared ByERICA ANENSONERICA.RAE.ANENSON@JCI.COMPHONE: Drawings Reviewed ByKENNETH DEITRICHKENNETH.REID.DEITRICH@JCI.COM702-408-5898SiteMADISON MEMORIAL HOSPITAL450 E. MAIN ST.REXBURG, ID 83440-2013Johnson Controls District - 4448783 WEST HACKAMORE DRIVEBOISE, ID 83709PHONE: 208-376-2111FAX: 208-376-2192SERVICE: 208-376-2111MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDING NEW DEVICES, RELOCATE AND DEMO EXISTING DEVICES AS SHOWN ON DRAWINGS.ALL NEW WIRING TO BE CLASS A.THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE WITHOUT WRITTEN PERMISSION FROM THE OWNER. ITIS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK.OCCUPANCY TYPE(S):SPRINKLER PROTECTION:I-2 INSTITUTIONAL GROUPBUILDING IS FULLY SPRINKLEREDJURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. CHECKWITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS.International Fire Code (IFC), 2015 EditionNational Fire Alarm Code (NFPA 72), 2016 EditionNational Electric Code (NFPA 70), 2017 EditionInternational Building Code (IBC), 2015 EditionANSI/ASME A17.1 2010 Elevator Code with State exceptionsFACPNAC1SF##WP#AIMSVSC#FIRE ALARM SYMBOL LEGENDSYMBOLDESCRIPTIONBRANDMODELBACKBOXWIRETYPEPANELS4100ES FIRE ALARM CONTROL PANEL, 120 VACSIMPLEX4100-9111SIMPLEX CABINETN/APOWERPATH 8AMP NAC EXTENDER W/CLASS A EXPANSION MODULEWHEELOCKPS-8N/AINITIATING DEVICESADDRESSABLE PHOTOELECTRIC SMOKE SENSOR W/ STANDARD BASESIMPLEX4098-9714 HEAD4" OCT, 1-1/2" DM4098-9792 BASEADDRESSABLE SINGLE ACTION MANUAL PULL STATIONSIMPLEX4099-90044" SQ, 2-1/8" D W/ SINGLE GANGCOVERMINSTITUTIONAL COVER KITSIMPLEX2099-9828ADDRESSABLE DUCT SMOKE DETECTORSIMPLEX4098-9755MOUNTS TO DUCTWORKMMODULES AND RELAYSINDIVIDUAL ADDRESSABLE MODULESIMPLEX4090-9001SINGLE GANG 2-1/2" D W/COVERMZNOTIFICATION APPLIANCESCONVENTIONAL STROBE ,CEILING MOUNT, WHITE, CLEAR LENS, FIREWHEELOCKRSS-24MCC-FW4" SQ. 1-1/2" DVCONVENTIONAL MULTI-CANDELA CHIME/STROBE ,CEILING MOUNT,WHITE, CLEAR LENS, FIREWHEELOCKCH90-24MCC-FW4" SQ. 1-1/2" D W/ 1-1/2" EXT RINGVCONVENTIONAL MULTI-CANDELA WEATHERPROOF HORN/STROBE,WALL MOUNT, RED, CLEAR LENS, FIREWHEELOCKASWP-2475W-FRMFGVCONVENTIONAL MULTI-CANDELA HORN/STROBE ,WALL MOUNT, RED,CLEAR LENS, FIREWHEELOCKMT-24MCW-FR4" SQ. 2-1/8" D - FLUSHVMISCELLANEOUS DEVICESTAMPER SWITCHBY OTHERSBY OTHERSZREMOTE TEST STATIONSIMPLEX2098-9806SINGLE GANG 2"DKACCEPTABLECABLE TYPESFIRE ALARM WIRE LEGENDFPLR FPLP THHN TFFN OUTDOOR ** C.I.CIRCUIT DESCRIPTIONCONSTRUCTIONGAUGECIRCUIT PROPERTIESBRUI + COMMUNICATIONUTP SOLID18 AWG58pf/ft. MAX CAPACITANCE, 35.5Ω TOTAL LINE RESISTANCEXXMIDNETUTP SOLID18 AWG60µF MAX TOTAL LINECAPACITANCEXXPPOWER2 COND. SOLID14 AWGXXXXVVISUAL2 COND. SOLID14 AWGXXCONDUIT SIZEMAX CONDUCTOR AREACONDUIT SIZEMAX CONDUCTOR AREA1/2"0.122 SQ. INCH*1-1/4"0.598 SQ INCH*3/4"0.213 SQ INCH*1-1/2"0.814 SQ INCH*1"0.346 SQ INCH*2"1.342 SQ INCH** 40% CONDUIT FILL PER N.E.C.STP = SHIELDED TWISTED PAIRITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEMINSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODELTHAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLEUPON REQUEST.AC=ABOVE CEILINGAFF=ABOVE FINISHED FLOORAHJ=AUTHORITY HAVING JURISDICTIONALM=ALARMANN=ANNUNCIATORBMS=BUILDING MANAGEMENT SYSTEMC=CEILING MOUNTEDCD=CANDELA RATINGDET=DETECTORDGP=DATA GATHERING PANELE=EXISTING TO REMAINEOL=END OF LINEEPO=EMERGENCY POWER OFFER=ELEVATOR RECALLFAA=FIRE ALARM ANNUNCIATORFACP=FIRE ALARM CONTROL PANELFATC=FIRE ALARM TERMINAL CABINETFBO=FURNISHED BY OTHERSFCC=FIRE COMMAND CENTERFSD=FIRE SMOKE DAMPERFTR=FIRE ALARM TRANSPONDERH=HIGH HUMIDITYHT=HEIGHTHVAC=HEATING VENTILATION & AIR CONDITIONINGIMS=INFORMATION MANAGEMENT SYSTEMMAX=MAXIMUMMIN=MINIMUMN/A=NOT APPLICABLENAC=NOTIFICATION APPLIANCE CIRCUITNDU=NETWORK DISPLAY UNITNEC=NATIONAL ELECTRIC CODENFPA=NATIONAL FIRE PROTECTION ASSOCIATIONNIC=NOT IN CONTRACTNPU=NETWORK PROCESSING UNITNTS=NOT TO SCALEPAP=PRE-ACTION PANELRC=EXISTING TO REMOVE AND COVERRD=EXISTING DEVICE TO BE RELOCATEDRL=RELOCATED DEVICERR=REMOVE EXISTING & REPLACE WITH NEWSCC=STATUS COMMAND CENTERSLC=SIGNALING LINE CIRCUITSMK=SMOKESUPV=SUPERVISORYTAC=TRUEALERT ADDRESSABLE CONTROLLERTOS=TOP OF SHAFTTRBL=TROUBLETS=TAMPER SWITCHTYP=TYPICALUON=UNLESS OTHERWISE NOTEDVCC=VOICE COMMAND CENTERVT=VALVE TAMPERW=WATTAGEW/=WITHW/O=WITHOUTWF=WATERFLOWWG=WIRE GUARDWP=WEATHERPROOFXP=EXPLOSION PROOFJOHNSON CONTROLS CONTACTSLAST PRINTED:LAST SAVED BY:FILE PATH:C:\Users\janense\Desktop\1_OtherDistrictProjects\_BoiseJobs\MadisonMemorial\MMH_BehavioralHealthTI_650046977\Fire\FA-001.dwg4/20/2021 11:54:48 AM JANENSE 444:650046977E.ANENSONDN3/18/21FIRE ALARM SYSTEMMADISON MEMORIAL HOSPITAL 450 E. MAIN ST. REXBURG, ID 83440-2013 8783 WEST HACKAMORE DRIVE BOISE, ID 83709 PHONE: 208-376-2111 SERVICE: 208-376-2111 FAX: 208-376-2192444046977DISTRICT - 444FA-001COVER SHEETJOHNSON CONTROLS © 2021MADISON MEMORIAL HOSPITAL BEHAVIORAL HEALTH-TI© Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited.IMPORTANT NOTICE TO USER: This information may not be sold or transferred to any third party, used on other projects or additions to the project for which itwas prepared, or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use or reuse of altered files by the user orany third party and such use will be a user's sole risk. User shall, to the fullest extent permitted by law, defend, indemnify, and hold Johnson Controls harmlessfrom any and all claims for loss, damage or injury arising directly or indirectly from any such unauthorized use.NVICINITY MAPSCOPE OF WORKSheet NumberSheet TitleGeneral Information (FA-000 Series)FA-001COVER SHEETFloorplans (FA-100 Series)FA-101DEVICE PLACEMENT PLANRisers & Calculations (FA-200 Series)FA-201RISER DIAGRAM & BATTERY CALCUALTIONSTypical Details (FA-700 Series)FA-701WIRING TYPICALSB BUSINESS GROUPS-1 STORAGE GROUPSYSTEM OUTPUTS ACTUATE COMMON ALARM SIGNAL INDICATOR ACTUATE AUDIBLE ALARM SIGNAL ACTUATE COMMON SUPERVISORY SIGNAL INDICATOR ACTUATE AUDIBLE SUPERVISORY SIGNAL ACTUATE COMMON TROUBLE SIGNAL INDICATOR ACTUATE AUDIBLE TROUBLE SIGNAL ACTUATE APPROPRIATE LOCATION INDICATOR ACTUATE ALL AUDIBLE EVACUATION SIGNALS ACTUATE ALL VISIBLE EVACUATION SIGNALS UNUSED DISPLAY CHANGE OF STATUS TRANSMIT ALARM SIGNAL TO SUPERVISING STATION TRANSMIT SUPERVISORY SIGNAL TO SUPERVISING STATION TRANSMIT TROUBLE SIGNAL TO SUPERVISING STATION UNLOCK SECURITY DOORS RELEASE ELEVATOR FIRE DOORS MAIN FLOOR ELEVATOR RECALL ALTERNATE FLOOR ELEVATOR RECALL ELEVATOR HAT FLASH ELEVATOR SHUNT TRIP RELEASE MAGNETICALLY HELD SMOKE DOORS FAN SHUTDOWN DAMPER SHUTDOWN REMOTELY DISPLAY ACTIVE STATUSCTRL UNIT ANNUNCIATIONNOTIFICATIONFIRE SAFETY CONTROLSYSTEM INPUTSABCDEFGHIJKLMNOPQRSTUVWX1SMOKE SENSOR/DETECTORXXXXXXXXXXXX2MANUAL PULL STATIONXXXXXXXX3DUCT SENSOR/DETECTOR - SUPERVISORYXXXXXXX4MAIN FLR. ELEV. LOBBY SMOKE DETECTORXXXXXXXXXXXXXX5ELEVATOR LOBBY SMOKE DETECTORS (EXC. MAIN FLR)XXXXXXXXXXXXXX6ELEVATOR MECH. ROOM HEAT DETECTORXXXXXXXXX7ELEVATOR MECH. ROOM SMOKE DETECTORXXXXXXXXXXXXXX8ELEVATOR SHAFT HEAT DETECTORXXXXXXXXX9ELEVATOR SHAFT SMOKE DETECTORXXXXXXXXXXXXXX10ELEVATOR POWER MONITORXXXXXX11WATERFLOW SWITCHXXXXXXXXXX12TAMPER SWITCHXXXXXX13GENERATOR RUNNINGXXXXXX14GENERATOR FAULTXXXXXX15FIRE ALARM AC POWER FAILUREXXXXX16FIRE ALARM SYSTEM LOW BATTERYXXXXX17OPEN CIRCUIT OR GROUND FAULTXXXXX18CLASS A NOTIFICATION CIRCUIT (NAC) - SHORTXXXXX1 04/20/21 DN ERA CHANGES PER CUSTOMER REQUEST 111 TABLETABLETABLETABLE2697SuppressionFire2680AOffice2681RoomBreak2679WorkroomBiomed. Tech.2673OfficeI.S.2671OfficeI.S.OfficeRT2653ExpansionPharmacy2666Hallway2660Corridor2670RoomData2668OfficeI.S.2667OfficeI.S.2659WorkroomI.S.IT02IT Room2654Pharmacy2647Corridor2656Storage2658Office2652Pharmacy Expansion2657Toilet2655Office2649Corridor2664HoldSoiled2662Dryers2661CleanLaundry2699OfficeHousekeeping2696Office2695Corridor2698Corridor2704MechanicalElectrical/2702Storage2703Storage2700Storage2701StorageH002Elevator201RECEPTIONSTAIRTEAM ROOM236CORRIDOR239221220212CORRIDORDAY ROOM206T.R.219T.R.2627213THERAPY207SECLUSION204234STORAGE232T.R.231T.R.2250Pool Equip.2251Exam2254Men's Toilet2255ToiletWomen's2252Whirlpool2253Whirlpool2256Open Storage2249P.T.RoomMeetingStorage2257OfficeP.T.2263StorageEducation2258O2 FillGas2240ToiletO.T.2241O.T.Exam2259Exam2260Exam2261Exam2245AreaEquipmentP.T Open2228Corridor2057Chiller2056BoilerMechanical/SMOKE ZONE 2-5IT01Meeting210NURSESTATION218T.R.DUAL OCCUPANTPATIENT ROOM217DUAL OCCUPANTPATIENT ROOMDIRECTOR'SOFFICE211GROUPTHERAPY/DINING212CORRIDOR208OBSERVATION/SECURITYVEST.203VISITING200EXISTINGCORRIDORSHARED DOCTOR'SOFFICE202SECURITYVESTIBULE235MEDIACENTER233DUAL OCCUPANTPATIENT ROOM230DUAL OCCUPANTPATIENT ROOM228T.R.229SINGLE OCCUPANTPATIENT ROOM225T.R.224T.R.226SINGLE OCCUPANTPATIENT ROOM223DUAL OCCUPANTPATIENT ROOM222SECURITYVESTIBULE227CORRIDOR216CORRIDOR248EVS241STAFF T.R.240NURSESTATION242237NURSESWORKROOM238MED STORAGE/DISPENSARY215EXAMEXISTINGSTAIRSANAC20:V1-1NAC20S1:M1-5S1:M1-6S1:M1-1FACPFATCNAC1NAC3NAC2NAC4151530NAC2:V3-275NAC20:V1-215NAC2:V3-1015NAC2:V3-1115NAC2:V3-915NAC2:V3-715NAC2:V3-415NAC2:V3-615NAC2:V3-515NAC2:V3-31515151515AOM1:M1-7EX.PS1:M1-8S1:M1-16S1:M1-17FATC15FACPS1:M3-891:M3-90EX.AOMP1:M3-84 EX.AOMP1:M3-87 EX.AOMP1:M3-88 EX.S1:M1-5S1:M1-11S1:M1-1275N7:V1-715N7:V1-8DHDH1515S1:M1-4S1:M1-21:M1-1EX.M,PTO NAC2:V3VVVVVVVVVVS1:M1-1JBMMM,PM,PM,P75NAC2:V3-1VTO NAC2:V3JBVVVTO NAC20LOCATED BY ITROOM110N7:V1-575N7:V1-61:M1-2110KS2:M1-9S2:M1-10P10K2KKRM,PM,PS2:M1-14S2:M1-17SR2:M1-16SR2:M1-15RRSR2:M1-13RRM,PM,PM,PM,PM,PM,PM,PM,PM,PF1:M5-81NAC1:V1-915NAC1:V1-1115NAC3:V3-415NAC1:V1-230S1:M5-88S1:M5-87S1:M5-84S1:M5-86S1:M5-82S1:M5-83S1:M5-80S1:M5-79S1:M5-8975WPNAC1:V3-2S1:M5-9130NAC1:V3-375NAC1:V3-1FAAM,PM,PM,PM,PM,PM,PM,PM,PM,PM,PM,PVVVVFEED FROMNAC1:V3RETURN TONAC1:V3VFEED FROMNAC1:V1VFEED FROMNAC3:V3RETURN TONAC3:V3RETURN TONAC1:V1VVVVVVVVVVVVVVVVVVVVVVVM,PEXISTING FEEDFROM 1:M5 CKTTIE INTO EXISTING1:M5 CKTKS1:M5-85AIM1:M5-77VSM,PM,PF1:M5-90CNAC3:V3-515CNAC3:V3-615CNAC3:V3-715CNAC3:V3-815CNAC3:V3-915CNAC3:V3-215CNAC3:V3-315CNAC1:V1-315CNAC1:V1-415CNAC1:V1-515CNAC1:V1-630CNAC1:V1-775CNAC1:V1-830CNAC1:V1-1015NIC112245332266SHEET:DRAWN BY:CHECKED BY:JOB #:PROJECT #:DESCRIPTIONCADDATEMARKSYSTEM:CHKISSUE DATE:30" x 42" - Arch E1 Size ISSUE LOG:Revisions shown with # symbol ERICA R ANENSONNICET LEVEL III#1359630SCALE:IN FEET1/8" = 1'-0"4'8'16'NSCALE:1/8" = 1'-0"DEVICE PLACEMENT PLANLAST PRINTED:LAST SAVED BY:FILE PATH:C:\Users\janense\Desktop\1_OtherDistrictProjects\_BoiseJobs\MadisonMemorial\MMH_BehavioralHealthTI_650046977\Fire\FA-101.dwg4/20/2021 11:54:53 AM JANENSE 444:650046977E.ANENSONDN3/18/21FIRE ALARM SYSTEMMADISON MEMORIAL HOSPITAL 450 E. MAIN ST. REXBURG, ID 83440-2013 8783 WEST HACKAMORE DRIVE BOISE, ID 83709 PHONE: 208-376-2111 SERVICE: 208-376-2111 FAX: 208-376-2192444046977DISTRICT - 444FA-101DEVICE PLACEMENT PLANJOHNSON CONTROLS © 2021MADISON MEMORIAL HOSPITAL BEHAVIORAL HEALTH-TI© Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited.FACPNAC1SF##WP#AIMSVSC#FIRE ALARM SYMBOL LEGENDSYMBOLDESCRIPTIONBRANDMODELBACKBOXWIRETYPEPANELS4100ES FIRE ALARM CONTROL PANEL, 120 VACSIMPLEX4100-9111SIMPLEX CABINETN/APOWERPATH 8AMP NAC EXTENDER W/CLASS A EXPANSION MODULEWHEELOCKPS-8N/AINITIATING DEVICESADDRESSABLE PHOTOELECTRIC SMOKE SENSOR W/ STANDARD BASESIMPLEX4098-9714 HEAD4" OCT, 1-1/2" DM4098-9792 BASEADDRESSABLE SINGLE ACTION MANUAL PULL STATIONSIMPLEX4099-90044" SQ, 2-1/8" D W/ SINGLE GANGCOVERMINSTITUTIONAL COVER KITSIMPLEX2099-9828ADDRESSABLE DUCT SMOKE DETECTORSIMPLEX4098-9755MOUNTS TO DUCTWORKMMODULES AND RELAYSINDIVIDUAL ADDRESSABLE MODULESIMPLEX4090-9001SINGLE GANG 2-1/2" D W/COVERMZNOTIFICATION APPLIANCESCONVENTIONAL STROBE ,CEILING MOUNT, WHITE, CLEAR LENS, FIREWHEELOCKRSS-24MCC-FW4" SQ. 1-1/2" DVCONVENTIONAL MULTI-CANDELA CHIME/STROBE ,CEILING MOUNT,WHITE, CLEAR LENS, FIREWHEELOCKCH90-24MCC-FW4" SQ. 1-1/2" D W/ 1-1/2" EXT RINGVCONVENTIONAL MULTI-CANDELA WEATHERPROOF HORN/STROBE,WALL MOUNT, RED, CLEAR LENS, FIREWHEELOCKASWP-2475W-FRMFGVCONVENTIONAL MULTI-CANDELA HORN/STROBE ,WALL MOUNT, RED,CLEAR LENS, FIREWHEELOCKMT-24MCW-FR4" SQ. 2-1/8" D - FLUSHVMISCELLANEOUS DEVICESTAMPER SWITCHBY OTHERSBY OTHERSZREMOTE TEST STATIONSIMPLEX2098-9806SINGLE GANG 2"DKACCEPTABLECABLE TYPESFIRE ALARM WIRE LEGENDFPLR FPLP THHN TFFN OUTDOOR ** C.I.CIRCUIT DESCRIPTIONCONSTRUCTIONGAUGECIRCUIT PROPERTIESBRUI + COMMUNICATIONUTP SOLID18 AWG58pf/ft. MAX CAPACITANCE, 35.5Ω TOTAL LINE RESISTANCEXXMIDNETUTP SOLID18 AWG60µF MAX TOTAL LINECAPACITANCEXXPPOWER2 COND. SOLID14 AWGXXXXVVISUAL2 COND. SOLID14 AWGXXCONDUIT SIZEMAX CONDUCTOR AREACONDUIT SIZEMAX CONDUCTOR AREA1/2"0.122 SQ. INCH*1-1/4"0.598 SQ INCH*3/4"0.213 SQ INCH*1-1/2"0.814 SQ INCH*1"0.346 SQ INCH*2"1.342 SQ INCH** 40% CONDUIT FILL PER N.E.C.STP = SHIELDED TWISTED PAIRITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEMINSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODELTHAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLEUPON REQUEST.GENERAL NOTES:1.ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESSNOTED OTHERWISE.2.THE DEVICE ADDRESSES INDICATED ON THESE DRAWINGS ARE ANALPHANUMERIC DESCRIPTION OF WHICH CIRCUIT THE DEVICE IS LOCATED ON.DEVICES MAY BE ASSIGNED A DIFFERENT NUMBER WITHIN THE PANEL PROGRAM.CONSULT WITH A JOHNSON CONTROLS TECHNICIAN BEFORE APPLYING APHYSICAL LABEL TO ANY DEVICES.3.ALL EXISTING CIRCUITING WITHIN THE SCOPE OF WORK AREA WILL BE REMOVED DURINGDEMO AND NEW WIRING WILL BE INSTALLED FOR CIRCUITS.4.EXISTING EQUIPMENT, DEVICES AND WIRING ARE REPRESENTED IN A LIGHTERCOLOR (GRAY) AND ARE TO REMAIN AS-IS UNLESS OTHERWISE NOTED.5.NEW EQUIPMENT, DEVICES AND WIRING ARE REPRESENTED IN A BOLD COLOR(BLACK) AND ARE TO BE INSTALLED AS DIRECTED ON PLANSKEYNOTES:TIE SLC CIRCUITS INTO CLOSEST EXISTING 1:M5 DEVICE. CIRCUIT INTEGRITY TOBE KEPT FOR CIRCUITING. ALSO TIE INTO EXISTING POWER CIRCUITING IF NECESSARY.EXISTING CIRCUITING REMOVED FROM DEMO. NEW CIRCUITING TO BE HOMERUNTO/FROM NAC1 (WHEELOCK PS-8) FOR EXISTING WHEELOCK NOTIFICATION DEVICES.EXISTING CIRCUITING REMOVED FROM DEMO. NEW CIRCUITING TO BE HOMERUNTO/FROM NAC3 (WHEELOCK PS-8) FOR EXISTING WHEELOCK NOTIFICATION DEVICES.CURRENT LOCATION OF NODE1, NAC1 & NAC3 PANELS.RELOCATE EXISTING NURSE STATION FAA TO THIS LOCATION. KEEP EXISTINGRUI & POWER CIRCUITS AS-IS.EXISTING DEVICE TO REMAIN. WIRE INTO IDNET 1:M5 CIRCUIT.123456SCALE:KEY PLANNTSSCOPE OF WORK AREAN1 04/20/21 DN ERA CHANGES PER CUSTOMER REQUEST 111111111111111111111 LEVEL 1LEVEL 1IDNet - 1:M5S1:M5-79F1:M5-81S1:M5-80S1:M5-82S1:M5-83S1:M5-84S1:M5-85S1:M5-87S1:M5-88S1:M5-89 NAC1:V175NAC1:V3-1 75WPNAC1:V3-2 30NAC1:V3-3 NAC1:V2NAC1:V1-2 30NAC1:V1-9 15NAC1:V1-11 15 NAC3:V3NAC3:V3-415M1SSP4100ESEXISTINGNODE 1FACP120 VOLT ACEXISTING 1:M5 DEVICESEXISTING 1:M5 DEVICESMM1SSP120 VOLT ACPS-8EXISTINGWHEELOCK PS1LOCATED IN 1STFLOOR MECH CORRLOCATED IN 1STFLOOR MECH CORRVVVVVVS1:M5-91KS1:M5-86AIM1:M5-77VSZ6.8K1SSP120 VOLT ACPS-8EXISTINGWHEELOCK PS3LOCATED IN 1STFLOOR MECH CORRF1:M5-90CNAC3:V3-930CNAC3:V3-875CNAC3:V3-715CNAC3:V3-615CNAC3:V3-515CNAC3:V3-315CNAC3:V3-215CNAC1:V1-10 15CNAC1:V1-8 30CNAC1:V1-7 75CNAC1:V1-6 30CNAC1:V1-5 15CNAC1:V1-4 15CNAC1:V1-3 15SHEET:DRAWN BY:CHECKED BY:JOB #:PROJECT #:DESCRIPTIONCADDATEMARKSYSTEM:CHKISSUE DATE:30" x 42" - Arch E1 Size ISSUE LOG:Revisions shown with # symbol ERICA R ANENSONNICET LEVEL III#135963SCALE:RISER DIAGRAMN.T.S.LAST PRINTED:LAST SAVED BY:FILE PATH:C:\Users\janense\Desktop\1_OtherDistrictProjects\_BoiseJobs\MadisonMemorial\MMH_BehavioralHealthTI_650046977\Fire\FA-201.dwg4/20/2021 11:54:55 AM JANENSE 444:650046977E.ANENSONDN3/18/21FIRE ALARM SYSTEMMADISON MEMORIAL HOSPITAL 450 E. MAIN ST. REXBURG, ID 83440-2013 8783 WEST HACKAMORE DRIVE BOISE, ID 83709 PHONE: 208-376-2111 SERVICE: 208-376-2111 FAX: 208-376-2192444046977DISTRICT - 444FA-201RISER DIAGRAM &BATTERY CALCUALTIONSJOHNSON CONTROLS © 2021MADISON MEMORIAL HOSPITAL BEHAVIORAL HEALTH-TI© Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited.RISER NOTES:1.RISER IS A DIAGRAMMATICAL REPRESENTATION OF THESYSTEM ARCHITECTURE IN BUILDING CROSS SECTION. IT ISNOT INTENDED TO REPRESENT ACTUAL WIRE RUNS, PANELCONFIGURATIONS OR PENETRATIONS. REFER TO FLOORPLANS AND PANEL DETAILS FOR CIRCUIT ROUTING ANDCONFIGURATION INFORMATION.2.ALL WIRING SHALL COMPLY WITH APPLICABLE ELECTRICALCODES. REFER TO 'APPLICABLE CODES & STANDARDS' ONSHEET FA-001 FOR SPECIFIC CODE REFERENCES.KEYED NOTES:120VAC PRIMARY POWER SOURCE SHALL BE AMECHANICALLY PROTECTED BRANCH CIRCUIT. THE CIRCUITDISCONNECTING MEANS SHALL HAVE A RED MARKING, ANDBE IDENTIFIED AS "FIRE ALARM CIRCUIT"1FACPNAC1SF##WP#AIMSVSC#FIRE ALARM SYMBOL LEGENDSYMBOLDESCRIPTIONBRANDMODELBACKBOXWIRETYPEPANELS4100ES FIRE ALARM CONTROL PANEL, 120 VACSIMPLEX4100-9111SIMPLEX CABINETN/APOWERPATH 8AMP NAC EXTENDER W/CLASS A EXPANSION MODULEWHEELOCKPS-8N/AINITIATING DEVICESADDRESSABLE PHOTOELECTRIC SMOKE SENSOR W/ STANDARD BASESIMPLEX4098-9714 HEAD4" OCT, 1-1/2" DM4098-9792 BASEADDRESSABLE SINGLE ACTION MANUAL PULL STATIONSIMPLEX4099-90044" SQ, 2-1/8" D W/ SINGLE GANGCOVERMINSTITUTIONAL COVER KITSIMPLEX2099-9828ADDRESSABLE DUCT SMOKE DETECTORSIMPLEX4098-9755MOUNTS TO DUCTWORKMMODULES AND RELAYSINDIVIDUAL ADDRESSABLE MODULESIMPLEX4090-9001SINGLE GANG 2-1/2" D W/COVERMZNOTIFICATION APPLIANCESCONVENTIONAL STROBE ,CEILING MOUNT, WHITE, CLEAR LENS, FIREWHEELOCKRSS-24MCC-FW4" SQ. 1-1/2" DVCONVENTIONAL MULTI-CANDELA CHIME/STROBE ,CEILING MOUNT,WHITE, CLEAR LENS, FIREWHEELOCKCH90-24MCC-FW4" SQ. 1-1/2" D W/ 1-1/2" EXT RINGVCONVENTIONAL MULTI-CANDELA WEATHERPROOF HORN/STROBE,WALL MOUNT, RED, CLEAR LENS, FIREWHEELOCKASWP-2475W-FRMFGVCONVENTIONAL MULTI-CANDELA HORN/STROBE ,WALL MOUNT, RED,CLEAR LENS, FIREWHEELOCKMT-24MCW-FR4" SQ. 2-1/8" D - FLUSHVMISCELLANEOUS DEVICESTAMPER SWITCHBY OTHERSBY OTHERSZREMOTE TEST STATIONSIMPLEX2098-9806SINGLE GANG 2"DKACCEPTABLECABLE TYPESFIRE ALARM WIRE LEGENDFPLR FPLP THHN TFFN OUTDOOR ** C.I.CIRCUIT DESCRIPTIONCONSTRUCTIONGAUGECIRCUIT PROPERTIESBRUI + COMMUNICATIONUTP SOLID18 AWG58pf/ft. MAX CAPACITANCE, 35.5Ω TOTAL LINE RESISTANCEXXMIDNETUTP SOLID18 AWG60µF MAX TOTAL LINECAPACITANCEXXPPOWER2 COND. SOLID14 AWGXXXXVVISUAL2 COND. SOLID14 AWGXXCONDUIT SIZEMAX CONDUCTOR AREACONDUIT SIZEMAX CONDUCTOR AREA1/2"0.122 SQ. INCH*1-1/4"0.598 SQ INCH*3/4"0.213 SQ INCH*1-1/2"0.814 SQ INCH*1"0.346 SQ INCH*2"1.342 SQ INCH** 40% CONDUIT FILL PER N.E.C.STP = SHIELDED TWISTED PAIRITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEMINSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODELTHAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLEUPON REQUEST.MADISON MEMORIAL HOSPITAL - NAC1 1ST FLR PS-8 NAC EXTENDERStandbyTotalAlarmTotalModuleQtyDescriptionCurrentStandbyCurrentAlarmPanel EquipmentPS-81POWERPATH 8-AMP NAC EXTENDER0.12900.12900.12900.1290PS-EXP1CLASS A EXPANSION MODULE0.00000.00000.00000.0000Panel Totals0.12900.1290Notification AppliancesSettingASWP-2475W-FR1WP HORN STROBE 75CD, 24VDC WALL, REDWP750.00000.00000.16800.1680CH90-24MCC-FW4MULTI-CD CHIME STROBE, CEILING, WHITE150.00000.00000.08700.3480CH90-24MCC-FW2MULTI-CD CHIME STROBE, CEILING, WHITE300.00000.00000.12700.2540CH90-24MCC-FW1MULTI-CD CHIME STROBE, CEILING, WHITE750.00000.00000.21100.2110MT-24MCW-FR1MULTI TONE, MCD HORN/STROBE, WALL, RED300.00000.00000.09200.0920MT-24MCW-FR1MULTI TONE, MCD HORN/STROBE, WALL, RED750.00000.00000.16500.1650RSS-24MCC-FW2MULTI CD STROBE, CEILING, WHITE150.00000.00000.06500.1300RSS-24MCC-FW1MULTI CD STROBE, CEILING, WHITE300.00000.00000.10500.1050Peripheral Totals0.00001.4730Added Current for EPS Conversion of 24 to 29 Volt IDNac Devices0.00000.0000RUI Totals00.00000.0000Address Totals0Addresses0.00000.0000System Totals*:Standby0.1290Alarm1.6020StandbyStandbyAlarmAlarmBattery Set #1 (Cabinet/Charger #1)CurrentTotalCurrentTotalSelect ALL Power Supplies on this battery set:PS-80.12901.6020Sub Total0.12901.6020Total0.12901.6020Standby Time =24Hrsx 0.1290= 3.0960Standby AhAlarm Time =5Min0.08333 x 1.602= 0.1335Alarm Ah3.2295Additional Spare Battery Capacity =0%+0.00003.2295Battery Discharge Factor =20%+0.6459Minimum Battery Required2081-9272 6.2AH (2x)3.8754Battery Supplied2081-9274 10AH (2x)* System Totals represent total system current requirements. Those currents may be distributed between multiple battery sets or power supplies as shown above.MADISON MEMORIAL HOSPITAL - NAC1 1ST FLR PS-8 NAC EXTENDER VOLTAGE DROPSPIDCH90-24MCC-FWCH90-24MCC-FWCH90-24MCC-FWRSS-24MCC-FWRSS-24MCC-FWASWP-2475W-FRMT-24MCW-FRMT-24MCW-FRSetting15cd30cd75cd15cd30cdWP7530cd75cdWIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE (UNCOATED STRANDED COPPER WIRE) @ 75 CelsiusDevice TypeMC CEIL A/VMC CEIL A/VMC CEIL A/VMC CEIL V/OMC CEIL V/OA/VMC A/VMC A/VSupv. Current0.00000.00000.00000.00000.00000.00000.00000.0000Alarm Current0.08700.12700.21100.06500.10500.16800.09200.1650Alarm Current @ 23 Volts0.08700.12700.21100.06500.10500.16800.09200.1650PowerPanelPlanDist. (D)WireWire Res.TotalV. DropVolt% VoltMin DeviceMaxNOTIFICATION CIRCUIT DESCRIPTIONSupplyCircuitCkt.FeetGauge/ Ft. (R)Alarm (A)(A*2D*R)@ EndDropVoltageDistanceBEHAVIORAL HEALTH CKT 1PS-8SIG1SIG342514ga0.00311.0482.79716.70314.34%16vdc532 Ft.42121UNKNOWN EXISTINGPS-8SIG2SIG414ga0.00310.0000.00019.5000.00%16vdc0 Ft.EXISTING WHEELOCK BH CKTPS-8SIG3SIG537514ga0.00310.4251.00118.4995.13%16vdc1311 Ft.111UNKNOWN EXISTINGPS-8SIG4SIG614ga0.00310.0000.00019.5000.00%16vdc0 Ft.NOTE:LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGINOF SAFETY, TAKING INTO CONSIDERATION THAT THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWNON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUITLENGTH, CONTACT YOUR LOCAL JOHNSON CONTROLS DISTRICT OFFICE.SCALE:NAC 1 BATTTERY CALCULATIONSN.T.S.MADISON MEMORIAL HOSPITAL - NAC3 1ST FLR PS-8 NAC EXTENDERStandbyTotalAlarmTotalModuleQtyDescriptionCurrentStandbyCurrentAlarmPanel EquipmentPS-81POWERPATH 8-AMP NAC EXTENDER0.12900.12900.12900.1290PS-EXP1CLASS A EXPANSION MODULE0.00000.00000.00000.0000Panel Totals0.12900.1290Notification AppliancesSettingCH90-24MCC-FW5MULTI-CD CHIME STROBE, CEILING, WHITE150.00000.00000.08700.4350CH90-24MCC-FW1MULTI-CD CHIME STROBE, CEILING, WHITE300.00000.00000.12700.1270CH90-24MCC-FW1MULTI-CD CHIME STROBE, CEILING, WHITE750.00000.00000.21100.2110RSS-24MCC-FW1MULTI CD STROBE, CEILING, WHITE150.00000.00000.06500.0650Peripheral Totals0.00000.8380Added Current for EPS Conversion of 24 to 29 Volt IDNac Devices0.00000.0000RUI Totals00.00000.0000Address Totals0Addresses0.00000.0000System Totals*:Standby0.1290Alarm0.9670StandbyStandbyAlarmAlarmBattery Set #1 (Cabinet/Charger #1)CurrentTotalCurrentTotalSelect ALL Power Supplies on this battery set:PS-80.12900.9670Sub Total0.12900.9670Total0.12900.9670Standby Time =24Hrsx 0.1290= 3.0960Standby AhAlarm Time =5Min0.08333 x 0.967= 0.0806Alarm Ah3.1766Additional Spare Battery Capacity =0%+0.00003.1766Battery Discharge Factor =20%+0.6353Minimum Battery Required2081-9272 6.2AH (2x)3.8119Battery Supplied2081-9274 10AH (2x)* System Totals represent total system current requirements. Those currents may be distributed between multiple battery sets or power supplies as shown above.MADISON MEMORIAL HOSPITAL - NAC3 1ST FLR PS-8 NAC EXTENDER VOLTAGE DROPSPIDCH90-24MCC-FWCH90-24MCC-FWCH90-24MCC-FWRSS-24MCC-FWSetting15cd30cd75cd15cdWIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE (UNCOATED STRANDED COPPER WIRE) @ 75 CelsiusDevice TypeMC CEIL A/VMC CEIL A/VMC CEIL A/VMC CEIL V/OSupv. Current0.00000.00000.00000.0000Alarm Current0.08700.12700.21100.0650Alarm Current @ 23 Volts0.08700.12700.21100.0650PowerPanelPlanDist. (D)WireWire Res.TotalV. DropVolt% VoltMin DeviceMaxNOTIFICATION CIRCUIT DESCRIPTIONSupplyCircuitCkt.FeetGauge/ Ft. (R)Alarm (A)(A*2D*R)@ EndDropVoltageDistanceUNKNOWN EXISTINGPS-8SIG1SIG314ga0.00310.0000.00019.5000.00%16vdc0 Ft.UNKNOWN EXISTINGPS-8SIG2SIG414ga0.00310.0000.00019.5000.00%16vdc0 Ft.BEHAVIORAL HEALTH CKT 2PS-8SIG3SIG540014ga0.00310.8382.10517.39510.80%16vdc665 Ft.5111UNKNOWN EXISTINGPS-8SIG4SIG614ga0.00310.0000.00019.5000.00%16vdc0 Ft.NOTE:LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGINOF SAFETY, TAKING INTO CONSIDERATION THAT THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWNON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUITLENGTH, CONTACT YOUR LOCAL JOHNSON CONTROLS DISTRICT OFFICE.SCALE:NAC 3 BATTTERY CALCULATIONSN.T.S.Madison Memorial Hospital - NODE 1 4100es FACPStandbyTotalAlarmTotalModuleQtyDescriptionCurrentStandbyCurrentAlarmPanel Equipment4100-911114100 CONFIG. DOMESTIC 120V*0.37300.37300.47000.47004100-60141NETWORK IF CARD, WIRED0.04600.04600.04600.04604100-60381DUAL RS-232 IF CARD0.13200.13200.13200.13204100-12912REMOTE UNIT INTERFACE0.08500.17000.08500.17004100-320638 RELAYS - 3 AMP0.01500.04500.19000.57004100-60521EVENT REPORTING DACT0.03000.03000.04000.04004100-31024MAPNET MODULE, UP TO 127 PTS*0.25501.02000.27501.10004100-60051MASTER CONTROLLER POWER SUPPLY0.00000.00000.00000.00004100-320318 RELAYS, 3 AMP CONTACTS0.02500.02500.28000.28004100-31032MAPNET ISOLATOR MODULE*0.05000.10000.05000.10004100-51251REMOTE POWER SUPPLY W/CHARGER - 120VAC0.15000.15000.18500.18504100-50051ZONE MODULE, 8 IDC, CLASS B0.07500.07500.19500.19504100-51012EXPANSION PWR SUPPLY (XPS) - 120VAC 60HZ0.05000.10000.05000.10004100-51161EXPANSION AUDIO SIGNAL CARD0.01800.01800.08000.08004100-06201TRANSPONDER INTERFACE MODULE0.08700.08700.08700.0870Panel Totals2.37103.5550IDNet Addressable Devices (SLC)4099-90067ADDRESSABLE DOUBLE ACTION MANUAL STATION, PUSH*Constant current draw of .8mA standby and 1mA alarm per address used.Devices requiring additional current are accounted for in the sectionlabeled "Miscellaneous Peripheral Devices Requiring Additional SystemPower".4090-90017IDNET SUPERVISED IAM*4098-971442TRUEALARM PHOTO SMOKE SENSOR4098-97332TRUEALARM HEAT SENSOR*4098-97565TRUEALARM DUCT SMOKE SENSOR W/ RELAY OUTPUT*4098-979240TRUEALARM SENSOR BASE*4098-97804TRUEALARM 2 WIRE RELAY SENSOR BASE*Mapnet Addressable Devices (SLC)2190-91722MAPNET SUPERVISED IAM*2099-979519MAPNET SINGLE ACTION PULL STATION*4098-9714133TRUEALARM PHOTO SMOKE SENSOR4098-973312TRUEALARM HEAT SENSOR*4098-9792145TRUEALARM SENSOR BASE*2190-917012MAPNET ISOLATOR MODULE*Miscellaneous Peripheral Devices That Require (Additional) System Power4098-98435ENCAPSULATED RELAY PAM-SD0.00000.00000.01500.07504098-97565TRUEALARM DUCT SMOKE SENSOR W/ RELAY OUTPUT0.00300.01500.01500.07504098-986042-WIRE RELAY FOR USE WITH 4098-9780 SENSOR BASE0.00000.00000.00000.0000Peripheral Totals0.01500.1500Added Current for EPS Conversion of 24 to 29 Volt IDNac Devices0.00000.0000RUI Totals00.00000.0000Address Totals234Addresses0.33750.3509* Device Address current draw included below (See Additional Current Draws):System Totals*:Standby2.7235Alarm4.05591. 2-wire detector alarm current is included in the alarm current of the Initiating Device Circuit.2. Backup Amplifier assumes Main Amplifier alarm current on failure.StandbyStandbyAlarmAlarmBattery Set #1 (Cabinet/Charger #1)CurrentTotalCurrentTotalSelect ALL Power Supplies on this battery set:SPS-12.13603.4200XPS-20.05000.0500XPS-30.05000.0500RPS-40.15000.1850Sub Total2.38603.7050Additional Current Draws:MAPNET/IDNet Device Address Communication Current234x 0.001442= 0.3375x 0.001500= 0.3509Sub Total2.72354.0559Spare addressable point capacity0%0x 0.001442= 0.0000x 0.0015= 0.0000Total2.72354.0559Standby Time =24Hrsx 2.7235= 65.3640Standby AhAlarm Time =5Min0.08333 x 4.0559= 0.3380Alarm Ah65.7020Additional Spare Battery Capacity =0%+0.000065.7020Battery Discharge Factor =20%+13.1404Minimum Battery Required2081-9279 110AH (2x)78.8424Battery Supplied2081-9279 110AH (2x)* System Totals represent total system current requirements. Those currents may be distributed between multiple battery sets or power supplies as shown above.IDNET CHANNEL N1:M5ADDRESSES IN USE: 67 (26.8%) | SPARE ADDRESSES: 183 (73.2%) SWITCH SETTINGSAddressDevice TypePoint TypeLocation Description123456789N1:M5-79PHOTOSMOKENICU SECURITY VESTIBULEN1:5-79XXXXXONN1:M5-80RPHOTOSMOKENICU CORRIDOR 236N1:5-80XXONN1:M5-81ADRPULPULLNICU BY NURSES STATIONN1:5-81XXXONN1:M5-82PHOTOSMOKENICU CORRDOR 212N1:5-82XXXONN1:M5-83PHOTOSMOKENICU DAY ROOM 210N1:5-83XXXXONN1:M5-84PHOTOSMOKENICU CORRIDOR 212N1:5-84XXXONN1:M5-85RPHOTODUCTNICU DINING DUCT DETECTORN1:5-85XXXXONN1:M5-86PHOTOSMOKENICU CORRIDOR 212N1:5-86XXXXONN1:M5-87PHOTOSMOKENICU CORRIDOR 216N1:5-87XXXXXONN1:M5-88PHOTOSMOKENICU CORRIDOR 227N1:5-88XXXONN1:M5-89PHOTOSMOKENICU CORRIDOR 227N1:5-89XXXXONN1:M5-90ADRPULPULLAHU HALL BY BACK EXITN1:5-90XXXXONN1:M5-91PHOTOSMOKENICU CORRIDOR 236N1:5-91XXXXXONN1:M5-92REMOVE FROM PROGRAMN1:5-92XXXXONN1:M5-93REMOVE FROM PROGRAMN1:5-93XXXXXONN1:M5-94REMOVE FROM PROGRAMN1:5-94XXXXXONSCALE:NODE 1 BATTTERY CALCULATIONSN.T.S.DEVICES AFFECTED IN SCOPE OF WORK AREA.(EXISTING M5-85 & M5-90 DEVICES THAT ARE TO REMAIN WILL KEEP THEIR EXISTING ADDRESSES)111111111 04/20/21 DN ERA CHANGES PER CUSTOMER REQUEST 11 SHEET:DRAWN BY:CHECKED BY:JOB #:PROJECT #:DESCRIPTIONCADDATEMARKSYSTEM:CHKISSUE DATE:30" x 42" - Arch E1 Size ISSUE LOG:Revisions shown with # symbol ERICA R ANENSONNICET LEVEL III#135963LAST PRINTED:LAST SAVED BY:FILE PATH:C:\Users\janense\Desktop\1_OtherDistrictProjects\_BoiseJobs\MadisonMemorial\MMH_BehavioralHealthTI_650046977\Fire\FA-701.dwg4/20/2021 11:55:01 AM JANENSE 444:650046977E.ANENSONDN3/18/21FIRE ALARM SYSTEMMADISON MEMORIAL HOSPITAL 450 E. MAIN ST. REXBURG, ID 83440-2013 8783 WEST HACKAMORE DRIVE BOISE, ID 83709 PHONE: 208-376-2111 SERVICE: 208-376-2111 FAX: 208-376-2192444046977DISTRICT - 444FA-701WIRING TYPICALSJOHNSON CONTROLS © 2021MADISON MEMORIAL HOSPITAL BEHAVIORAL HEALTH-TI© Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited.DEVICE MOUNTING HEIGHT REFERENCEPER NFPA 72SIDE WALLCEILINGVISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS1.MIN DISTANCE IN SLEEPING ROOMS IS 24" (610mm) FROM CEILING TO TOPOF LENS FOR 110CD STROBES WITHIN 16' OF THE PILLOW2.177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24"(610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER INTENSITY ISTO COMPENSATE FOR A POSSIBLE SMOKE LAYER.AUDIBLE ONLYAUDIBLE/VISUAL& VISUAL ONLYAPPLIANCESSYNCHRONIZE MORETHAN TWO APPLIANCESIN ANY FIELD OF VIEW.NOTE: REFER TO THE PROPER DEVICEINSTALLATION INSTRUCTIONSFOR BACKBOX MOUNTING HEIGHT.NOTE: MEASUREMENTSSHOWN ARE TO THE CLOSESTEDGE OF THE DETECTOR.THE 4" REQUIREMENT FOR SMOKE DETECTORS HASBEEN REMOVED FROM THE 2010 EDITION OF NFPA 72CEILING MOUNTEDSMOKE/HEATDETECTORACCEPTED HEREHEAT DETECTORSNEVER HEREWALL MOUNTEDSMOKE/HEAT DETECTOR4"(102mm)4"(102mm)3' (914mm)MINIMUMA/C SUPPLYOR RETURNDIFFUSERFINISHEDFLOORFIREMAGNETICDOORHOLDERFIREPHONEJACKFOR CEILING HEIGHTS LESS THAN 86"(2180mm), THE VISUAL LENS MOUNTING HEIGHTSHALL BE WITHIN 6" (150mm) OF THE CEILING.96" MAX (ADA, IBC, NFPA)(2440mm MAX)ABOVE FINISHED FLOORTO TOP OF LENS48" MAX (ADA) (1219mm)48" MAX (NFPA, ADA) (1219mm MAX)42" MIN (NFPA) (1067mm MIN)MEASUREMENTS SHOWN ARETO TOP OF PULL HANDLEMANUAL PULLSTATIONTO EXIT DOOR5' (MAX.)(1524mm)DOORWIDTHLESS 3"(76mm)5"(127mm)90" MIN (2286mm MIN)ABOVE FINISHED FLOOR(OTHER MOUNTING HEIGHTS SHALL BEPERMITTED BY THE AHJ PROVIDING IT MEETSTHE SOUND LEVEL OUTPUT REQUIRED.)NFPA 72 AUDIBLE APPLIANCE 6" MIN(152.4mm MIN) BELOW FINISHED CEILINGFIREFINISHEDWALL12" (305mm)MAXIMUM TO TOP OF SENSOR80" MIN (ADA, IBC, NFPA)(2032mm MIN)ABOVE FINISHED FLOORTO BOTTOM OF LENS0=OFF1=ON2412422442452432402472482502512492532542552522461931941961971952092102112122131922081451461481491471611621631641651441601761771781791801811992002022032012152162172182192052062072212222232042201511521541551531671681691701711571581591731741751561721831841851861871881891901911501661821982142242252262272282292302312322332342352362372382391286432786842423516ADDRESS SHOWN ABOVE IS 1201ON1OFF1291301321331319798100101991131141151161179611212881828485834950525351656667686948648013513613913813710310410610710511912012112212314214114310911011112512612710812414087889190895556585957717273747594939561626377787960769254708610211813433343637351245317181920210163239404342417810119232425262746454713141529303112284462238DIP SWITCHES 5 THRU 8DO NOT USE ADDRESS 0 FOR AN IDNET ADDRESS9NOTE:THE 4098-9771, -9794, -9795, -9798 SOUNDER BASES HAVE A 9-POSITION DIP SWITCH. THE FIRST EIGHT DIP SWITCHES SET THESOUNDER BASE ADDRESS. DIP SWITCH POSITION 9 IS SET TO OFF OR ON DEPENDING UPON THE SOUNDER BASE POWERSOURCE. WHEN THE SOUNDER BASE IS CONNECTED TO A 24 VDC POWER SOURCE, DIP SWITCH POSITION 9 IS SET TO “OFF”AND THE 24 VDC POWER IS SUPERVISED BY THE SOUNDER BASE. WHEN THE SOUNDER BASE IS POWERED BY THE PANEL’SNOTIFICATION APPLIANCE CIRCUIT (NAC), DIP SWITCH POSITION 9 IS SET TO “ON” AND THE POWER IS SUPERVISED BY THENAC AND NOT THE SOUNDER BASE. THE 4098-9770 AND -9797 BASES HAVE THE SAME LAYOUT, BUT DOESN’T OFFERSOUNDER FUNCTIONALITY. THEY USE AN 8-WAY DIP SWITCH ONLY.SEENOTEDIPSWITCHES1 THRU 4DIP SWITCH SETTINGS - INITIATINGSIMPLEX IDNet0=OFFBAUD64 87168453421ON12ADDRESS SHOWN ABOVE IS 56632DO NOT USE ADDRESS 0 FOR A RUI ADDRESS1141131171161151121191188182848583666569686780644950333452533637355118172120193216488788919089727175747394939578777992765556394059584342415724232726256261464563473029314428603822867054DIP SWITCHES 1 THRU 4102108111110109105107106104103969910110098971245307811109141315126OFF1=ONDIPSWITCHES5 THRU 8COMMUNICATIONS DIP SWITCH SETTINGSSIMPLEX RUI (REMOTE UNIT INTERFACE)1.MAINTAIN CORRECT POLARITY ON TERMINALCONNECTIONS.2.ALWAYS CUT CONDUCTORS AND SECURE UNDERTERMINALS. NEVER LOOP WIRES UNDER TERMINALS.3.ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJAPPROVED METHODS.WIRING NOTESTOP OF PULL HANDLETO BE MOUNTED AT42" - 48" A.F.F.1.FOR ADDITIONAL MOUNTING OPTIONS, DOWNLOAD DATA SHEET 4099-0005 FROM HTTP://WWW.SIMPLEX-FIRE.COMALARMFIREPULL DOWN1234IDNet SLC(-)(+)IDNet SLC(RETURN)(-)(+)ADDRESSABLE PULL STATIONS1234CLASS A WIRINGTERMINATION VIEW: DEVICE REARPUSH4099-9005BREAKGLASS4099-9006PUSHWITH 2099-9828INSTITUTIONALCOVER KIT4099-9004SINGLE ACTION4099-9021NO GRIPSINGLEACTION4099-9805NO GRIPRETROFIT KITMOUNTING OPTION "B"SIMPLEX 4099 SERIESMOUNTING OPTIONSOPTION 1DESCRIPTIONNOTEASINGLE GANG BOX, 2-1/2" (64mm) DEEPBY OTHERSB4" (102mm) SQUARE BOX, 2-1/8" DEEP (MIN) W/ SINGLE GANG COVER PLATE 3/4" (19mm)EXTENSIONBY OTHERSCSIMPLEX 2975-9022 - 5H x 3-7/8"W x 2-3/16"D (127mm x 98mm x 56mm)ORDERED SEPARATELYDSIMPLEX 2975-9178 - 5-3/4"H x 3-7/8"W x 2-3/16"D (132mm x 102mm x 56mm)ORDERED SEPARATELYKEYOPERATEDONLY1.MAINTAIN CORRECT POLARITY ON TERMINALCONNECTIONS.2.ALWAYS CUT CONDUCTORS AND SECURE UNDERTERMINALS. NEVER LOOP WIRES UNDERTERMINALS.3.ANY WIRE SPLICES TO BE MADE BY LISTED ANDAHJ APPROVED METHODS.WIRING NOTES1.FOR ADDITIONAL MOUNTING OPTIONS, SEE MANUFACTURER DATA SHEET.CLASS A WIRING - 2 WIRE CONFIGURATIONMOUNTING OPTION "A"TERMINATION VIEW: SPEAKER MOUNTING PLATE(+)(-)(+)(-)(-)(+)VIS(-)(+)VISTO NEXT DEVICE ORRETURN TO FACPMOUNTING OPTION "B"CONVENTIONAL NOTIFICATION APPLIANCESWHEELOCK MT-24MCW SERIES WALL MOUNTED HORN/STROBE(-)(+)AUD(-)(+)AUDWHEELOCK IOB-R(2)WOODSCREWS(4)#8-18X1" SCREWS(4)SCREW COVERSMOUNTING OPTIONSOPTION1DESCRIPTIONNOTEA4" (102mm) SQUARE BOX, 2-1/8" (54mm) DEEP - FLUSH MOUNTINGBY OTHERSBWHEELOCK IOB-R SURFACE MOUNT BOX2MANUFACTURERELECTRICAL BOX(2)#8-18X1" SCREWS(4)SCREW COVERSNACCIRCUIT1.MAINTAIN CORRECT POLARITY ONTERMINAL CONNECTIONS.2.ALWAYS CUT CONDUCTORS AND SECUREUNDER TERMINALS. NEVER LOOP WIRESUNDER TERMINALS.3.ANY WIRE SPLICES TO BE MADE BY LISTEDAND AHJ APPROVED METHODS.WIRING NOTESIDNetSLC(-)(+)(-)(+)STANDARD SENSOR BASETERMINATION VIEW: DEVICE REARCLASS A WIRINGSENSORIDNet SLC(RETURN)3' (941mm)MIN.4" (102mm)CEILING MOUNTED SENSORHEAT SENSORS NEVER HERE12"(305mm)MAXIMUMTO TOP OFSENSORFINISHED WALLWALL MOUNTED SENSORMOUNTING OPTION "A"SIMPLEX 4098-97921.FOR ADDITIONAL MOUNTING OPTIONS, DOWNLOAD DATA SHEET 4098-0019 FROM HTTP://WWW.SIMPLEX-FIRE.COMMOUNTING OPTIONSOPTION 1DESCRIPTIONNOTEASINGLE GANG BOX, 2-1/8" (54mm) DEEP - FLUSH MOUNTBY OTHERSB4" (102mm) OCTAGONAL BOX, 1-1/2" (38mm) DEEP, MINIMUM - FLUSH MOUNTBY OTHERSC4" (102mm) SQUARE BOX, 1-1/2" DEEP (MIN) W/ SIMPLEX 4098-9832ADAPTER KITBOX BY OTHERS, 4098-9832 ORDEREDSEPARATELYD4" (102mm) SQUARE BOX, 1-1/2" DEEP (MIN)W/ SINGLE GANG COVER PLATE 3/4" (19mm) EXTENSIONBY OTHERSBASEELECTRICAL BOX#6-32 SCREWWITH WASHER(NOT SUPPLIED)#8-32 x 1-1/4" PANHEADMACHINE SCREW(TIGHTEN TO 4-6 in.-lbs.)MOUNTING OPTION "B"1.MAINTAIN CORRECT POLARITY ON TERMINALCONNECTIONS.2.ALWAYS CUT CONDUCTORS AND SECURE UNDERTERMINALS. NEVER LOOP WIRES UNDERTERMINALS.3.ANY WIRE SPLICES TO BE MADE BY LISTED ANDAHJ APPROVED METHODS.WIRING NOTES1.FOR ADDITIONAL MOUNTING OPTIONS, DOWNLOAD DATA SHEET P83911 FROM HTTP://WWW.COOPERINDUSTRIES.COMSTROBECIRCUIT(+)(-)(+)(-)CONVENTIONAL NOTIFICATION APPLIANCESTERMINATION VIEW: REAR OF DEVICECLASS A WIRINGSTROBECIRCUIT(RETURN)MOUNTING OPTION "A"STROBE INTENSITYSETTING VIEWABLETHROUGH THE LENSELECTRICAL BOXPROVIDED BY ELECTRICALCONTRACTOR.STROBE MOUNTING PLATE(SMP)#8-32 X 3/4" SCREWSBEAUTY PLATE (SUPPLIED)WHEELOCK RSS SERIES WALL AND CEILING MOUNTED VISUALMOUNTING OPTIONSOPTION1DESCRIPTIONNOTEA4" (102mm) SQUARE BOX, 1-1/2" (38mm) DEEP - FLUSH MOUNTINGBY OTHERSBWHEELOCK SHBB SURFACE MOUNT BOXMANUFACTURER11 04/20/21 DN ERA CHANGES PER CUSTOMER REQUEST 11.MAINTAIN CORRECT POLARITY ON TERMINALCONNECTIONS.2.ALWAYS CUT CONDUCTORS AND SECURE UNDERTERMINALS. NEVER LOOP WIRES UNDERTERMINALS.3.ANY WIRE SPLICES TO BE MADE BY LISTED ANDAHJ APPROVED METHODS.WIRING NOTES1.FOR ADDITIONAL MOUNTING OPTIONS, SEE MANUFACTURER DATA SHEET.2.BACKBOX IS COMPATIBLE WITH WIREMOLD AND CONDUIT.CLASS B WIRINGMOUNTING OPTION "A"STROBECIRCUIT(-)(+)(-)TERMINATION VIEW: DEVICE MOUNTING PLATEAUDIOCIRCUIT(+)(-)(+)(-)(-)(+)(+)(-)AUDSTRB(-)(+)(+)(-)AUDSTRBTO NEXTDEVICEOR 10KEOLMOUNTING OPTION "B"CONVENTIONAL NOTIFICATION APPLIANCESWHEELOCK HS4 SERIES (4-WIRE) WALL & CEILING MOUNTED AUDIBLE / VISUAL(4) SCREW COVERS(2) #8-18x1" SCREWS SCREWS(4) #8-18x1"(4) SCREW COVERSWHEELOCK IOB-R SCREWS(2) WOODMOUNTING OPTIONSOPTION1DESCRIPTIONNOTEA4" (102mm) SQUARE BOX, 2-1/8" (54mm) DEEP, WITH 1-1/2" (38mm) EXTENSION RING - FLUSHMOUNTINGBY OTHERSBWHEELOCK IOB SURFACE MOUNT BOX2MANUFACTURERELECTRICAL BOX