HomeMy WebLinkAboutSTAFF REVIEWS - 06-00533 - Avonlea Apartments - 9 Units'0� 't. 0N.9kik ,
01 a.p
OL,
C1 TY OF
REXBURG
A n; e rica k Fain ily Com m u, x ity
Review Action
December 18, 2006
:Permit Number: 06 00531
Project Name: Avonlea Apartments -9 Units
Project Type:
Site Plan Review
Review Item
Buitcfing Departme'n't Review
Plumbing Review
Fire Separation
Number of Parking Spaces
Parcel #'s RPROOSE0090200
P. Box 280
19 E Main St.
Rexburg, Idaho 83440
Phone (208) 359-3020
Fax (208) 359-3022
Actions Re wirAWro�ed
Rear wall must be rated. See explaination on
building permi# review #06 00533.
Four handicapped parking spaces are required
as per I BC Section 1146.1. One must be van
accessible.
1 T O F
RE."zURG
ret s am ! �n �3 j ?
Review Action
December 18, 2006
Permit Number: 06 00531
Project.Name: Avonlea Apartments -9 Units
Project type: Site Plan Review
review Item.
Fire Department Review
Additional Comments
Fire Lane Signage
Fire Access Roads
Water Supply
Parcel #'s RPROOSE0090200
0
P.o Box 280
19 E. Mein St.
Rexburg, Naha 834.4[}
Phone (208) 359-3020
Fax (2Q8) 359-3022
I Approved
KNOX BOX WILL BE REQUIRED FOR THIS 11/15/2006
OCCUPANCY. PLEASE CONTACT CHRIS
FOR ANY QUESTIONS AT 705-1312-
NOT
REQUIRED. 11/15/2006
PROVIDED 11/15/2006
HYDRANT WITHINREQUIRED DISTANCE 11/15/2006
WITH FULL FIRE SPRINKLER SYSTEM.
,r
FD
5
1 TY 0 F
December 18, 20-06
Permit Number: 06 00531
Project Name:
Project Type:
Review Item
Review Action
Avonlea Apartments -9 Units
Site Pian Review
Public Works Review
Approved Site Play
Parcel #'s
"ROOSE0090200
Actions ReCIt —
u�
1. With out property lines shown it is unable to
calculate required setbacks, etc.
2. The existing building is established at Q.7
parking stalls per bed. The managers house
will alio have to be calculated within this
number. The proposed building will have to
have 1.0 parking stalls per bed.
3. Unable to calculate snow storage and
landscaping without property lines shown.
4. There is no clear delineation between what
is landscaping, concrete and asphalt surfacing.
5. Water and sewer service is okay.
6. No porvisions are shown for snaitation
storage and pick up.
7. Buffering will be required from the residential
use to the east of the parking lot.
RO Box 280
1 E- Main Ste
Rexburg, Idaho 83440
Phone (208) 359-3020
Fax (208) 359-3022
�� ATF! _ S�
-�')
CITY 0
REXBURG
Arnerica's Family Community
December 18, 2006
Permit Number: 06 00533
Project Name:
Project Type:
Review Item
Review Action
Avonlea Apts-9 Units
Multi Family Residential
Building Department Review
Access ibili#y Review
Exiting Review
Plumbing Stora Drain Review
Plumbing Sewer Dain Review
Miscellaneous
Height and Area Review
Building Code Fire Compliance Review
Structural Review
Mechanical Review
Action
Meets code requirements.
Meets code requirements.
1
Plans must be stamped and signed by
architect. Provide mechanical vents at
bathrooms. Safety glazing is required where
adjacent to ramps and walkways as per IBC
Section 24x6.3. Please identify.
Meets code requirements..
South (rear) wall must be 1 hr. rated as per 113C
Table 602. Please show details on plan. IBC
Table 7a4.8 identifies that a maximum of 10%
of the area of the South wall can be in non -rate
windows. The wall in question appears to have
about 18% of the areain windows. Provide
penetration details for plumbing in party walls.
ABS drain pipe and especially the penetrations
at the Toilets are a major concern. How are the
HVAC ducts and returns being- seperated?
Provide details.
Structural shearwalis are called out as typel
and type 2. The shearwali descriptions on
Sheet A8 do not match what is required in the
structural calc;ulation5. Special inspections are
required for foundation, high strength bolting
and welding. Provide a letter from the special
inspection firm that identifies items to be
inspected and intervals.
Provide truss details prior to frame inspection.
Provide mechanical sizing and details.
P.0 Box 280
19 E. Main St.
Rexburg, Idaho 83440
Phone (208) 359-3020
Fax (208) 359-3022
A"roved
1 211 3/20 06
12/13/2006
C I T Y 0
REXBURG
Ow
December 18, 2006
Permit Number: 06 00533
Project Name:
Project Type:
Review lien
Review Action
Avonlea Apts-9 Units
Multi family Residential
Energy Conservation Compliance Review
Building Type Compliance
Complies with approved Site Plan Review
Electrical i arca its Review
Wafer and Sewer Service
Plumbing Potable Water Review
Parcel Vs RPROOSE0090200
Actions Req-Lred--fqr-Ap"ovaJ
Please provide electrical energy review as per
the 2D03 International Energy Conservation
Code.
Building is Type VB, Occupancy is R2.
Site pian has been reviewed, see site plan
permit for details.
If a design build, must meet EIEC 2Q05 code
requirements. No electrical plan was provided.
Must also bond to gas and wafer where
applicable. Need to provide two, sources of
grounds such as two ground rods, one
concrete encased electrode and one ground
rod, etc.
P-0 Box 280
19 E. is i n St.
Rexburg, Who $3440
Phone (208) 359-302
Fax (208) 359-3022
December 18, 2006
Permit Number: 06 00533
Project dame:
Project Typ.e,-
Review Action
Avonlea
Apts.-9 Units
Multi Family Residential
Review item
Fire Department Review
Floor Area
Required Fire Flow
Water Supply
Fire Access Roads
Fire Extinguishers
Automatic Fire Extinguishing Systems
Standpipes
Commercial Cooking
Alarm Systems
Other Comments
Parcel #'s RPRD05E0090200
P.O Box 2$0
99 E Mein St.
Rexburg, Idaho 83440
Phone (2D8) 359-3020
Fax (208) 359-3022
Actions R wired for A rovai A ro—ved
#,
F
REXBURG
Derrcds F tndy Commullity
December 20, 2006
Permit Number:
Project Name:
Project Type;
Review Action
0600533
Avonlea Apts-9 Units
Multi Family Residential
Review Item
Administrative Review
Permit Tech Notes
Parcel #'s
RPROOSE0090200
Actions Required tro►ra�
P-0 Box 280
Rexburg, Idaho 83440
Fhane (2Q8) 359-3020
Fax (2,08) 359-3022
General, Plumbing, Mechanical, & Electrical
contractor information & signatures seeded.
s
tib' OIF
REXBURG
America's Family Cornmullity
December 20, 2006
Permit Number: 06 00533
Project Mame:
Project Type:
Review Item
Review Action
Avonlea Apts-9 Units
Multi Family Residential
Building Department Review
Accessibility Review
Exiting Review
A
Plumbing Storm Drain f i
Plumbing Sewer Drain Review
Water and Sewer Service
Plumbing Potable Water Review
Electrical Circuits review
Structural i t
Meets code requirements.
Meets code requirements.
N/A
All drains are required to be tested and
inspected before covering. No piping shown an
plans.
Water and sewer services are not shown on
plans. Servcies are required to be bested and
inspected before covering. Water servcie shall
be sized according to the Uniform Plumbing
Gude 2p03 edition.
AIS water lines are required to be sized and
installed according to the Uniform Plumbing
Code 2003 edition. ASI lines are required to be
tested and inspected before covering. Proper
backflow prevention devices are required to be
installed and tested proir to final plumbing
inspection.
If a design build, mast meet NEC 20p5 code
requirements. No electrical plan was provided.
Must also bond to gas and water where
applicable. Need'to provide two sources of
grounds such as two ground rods, one
concrete encased electrode and one ground
rod, etc.
Structural shearwalls are called out as type'I
and type 2. The shearwall descriptions on
Sheet A8 do not match what is required in the
structure! calculations. Special inspections are
required for foundation, high strength bolting
and welding. Provide a letter from the special
inspection firm that identifies items to be
inspected and intervals.
Provide tress details prior to frame inspection.
P-0 Box 280
19 E. Mara St.
Rexburg, Idaho 8340
Phone (2a8) 359-3024
Fax (2[}8) 359-3022
—Ap-pLoved
12/13/2006
12/13/2006
f%
72/19/2006
1 2/1 912 006
1 211 9/2 0 0 6
1 211 9/2 006
CITY OF
RE"URG
December 20, 2006
Permit Number: 06 00533
Project Name: Avonlea APts-9 Units
Project Type:
Review Item
Mechanical Review
Miscellaneous
Review Action
Mufti Family Residential
Height and Area Review
Energy Conservation Compliance Review
Building Code Fire Compliance Review
Complies with approved Site Plan Review
Building Type Compliance
Parcel #'s "ROOSE00-90200
Action_s_Requiredl far Ap"rva!
Provide mechanical sizing and details.
Plans mush be stamped and signed by
architect. Provide mechanical gents at
bathrooms, Safety glazing is required where
adjacent to ramps and walkways as per I BC
Section 2406,3. Please identify.
Meets cede requirements_
Please provide electrical energy review as per
the 2003 International Energy Conservation
Code,
South {rear} wall must be 1 hr. rated as per IBS
Table 6Q2. Please show details on plan. !BG
Table 7D4.8 identifies that a maximum of 10%
of the area of the South walk can be in non -rated
windows. The wall in question appears to have
shout 18% of the area in windows. Provide
penetration details for plumbing in party wills.
ABS drain pipe and especially the penetrations
at the toilets are a major concern. Haw are the
HVAC ducts and returns being seperated?
Provide details.
Site plan has been reviewed, see site plan
permit for details.
Building is Type Vg. Occupancy is R2.
P.0 Box 280
1 E. Main t.
Rexburg, Idaho 83444
Phone (208} 359-3020
Fax (2a8) 359-322
—Am. -roved
T Y OF
EXBURG
December 20, 2006
Permit Number: 06 00533
Project Name:
Project Type:
Review item
Review Action
Avonlea Apts-9 Units
Multi Family Residential
Fire Department Review
Required Fire Flow
Other Comments
Fire Extinguishers
Automatic Fire Extinguishing Systems
Standpipes
Alarm Systems
Commercial Cooking
Pias AccerSS Roads
Water Supply
Floor Area
Ac--fi
0
See site plan review
r
Lock box is requied for this occupancy. Forms
are available at the Rexburg Fire Department.
Lock box is requied to be 3200 series. Lock box
is required to in -stalled prior to final fire
inspection.
Fire extinguishers are required for each tenant
spare. Minimum of 2AI OBC extinguishers are
required as noted on plans.
Fire sprinklers ars required for occupancy.
Submitt plans to State Frew Marshall. Plans
must be approved prior to installation of fire
sprinkler system. Approved plans are required
to be located on jab site. Operational permit
must be purchased by Certified fire sprinkler
contractor prior to installation of sprinkler
system.
N/A
Fire alarm plans are required to be submitted
and approved prior to installation for fire alarm
system. Outside notification is required at the
front of the building. outside notification is
required in addition to the device used to
indicate water flow.
Letter of intent is required from Certified firs
alarm contractor.
NIA
See site plan review
See site plan review
P-0 Box 280
19 E. Main St.
Rexburg, Idaho 83440
Phone (20$) 359-3020
fax (.208) 359-3022
12/19/2006
12/19/2006
12/19/2006
12/19/2006
12/19/2006
12/19/2006
12/19/2006
1 211 9/2 00 6
12/19/2006
Mennory TX Resul t Report D e C, 20, 2'uv� �; ��P��� i ^4
2)
Date/Tirrje: Dec,20, 2006 5:22PM
File P a -
MO � e Destunahion _
eu��
— -- N!0t �eni
__--_—�—-------------�_ __
- - - - - - - - - - - - - - - 0 - - - - - - - - - - - - - -
3J'53 Memory
IX -545 9 0 P
12 OK
ti
sore for error
E. 1 Hang u p o r line fail E. )E. 3) No answer 'u'
E. E c e d m E—Ma i 1 s i z e
r
Fax
I
V�LM=Aw6vjlP r
REXBURG
Irl, ZMR rv.+Inna Ow
`33...
Tv FR;�S-
FMC
19-05.54
Phan0
Re;
Proms . uNell HarGen
Pogue; 12
Dtft December 20, 2(X)6
c
13 Urgent 13 For ftevj6w 13 Plemm Cfxmnwrit 13 Pose R Ll P R. to
a Commwflv
Here ure the silu Plan ar)d bull ieViboles for Avonkni. When revWbns are subrKilt
p, n ad fwt� mop;
Thank You.
„ 'Well r-lan. yn
Ross- dit ari the fax i sent aril r- t was rn plt.
Here Is the complete set.
P�
Memory TX Result Report : Ic A r�2 0 U" 6 0 1 11� jgli , Y'e,
1' d I1 J 7 ]�T •I•
Daie/Tirne: Dec," 2006 10:31,AM
s
F
Mo d e D
estinaiion-
-(S) R e s u
�1t — — — — — — — — — — — — — — — — — — — — — — - No
— — — — — — — — — — — — — — — — — — — — —
-1 J 2 '1' 4ern o t y I A
52241 5 1
— — -- _ — — `—. — — — — — — — — ` — —,. — — — — — — — — — — —
Hang up o r n fa r
E. o answer �. o f a t s 'r m i l
E. Exceeded max. E—ma 1 1 s i �e e co-nnt Ion
C I Ir r dj 2
�'f 2 RIM4
"24 eke
Fox
1
Tom: Ke ffi Kennedy
Fac 32Z4151
Phi
From: JaNell HgnEen
7
DOW. DOCembe=r 18, 2CO6
C
❑ tPgvM1 LIr W O p1 DP;OMMOReply f3p l ig
a COMme
kiare the ruView cornmeritsfor tho Avonlca BUldin . Picirgling & ZoNng hm rpt
C.aFn s 1 heir 1uAaw Yet. ften it has boen coveted1 iI fa� the notes ova,
Thunk Y �;F