GENERAL NOTES
All work shall be consistent with the —best practices of ' he trades involve4 and conform"to the
20031 RC. :
Owner/Contractor or sub -contractor shall verify plans, dimensions and any work or
construction.
Any footing or foundation re -design shall be performed by a registered professional engineer.
Roof truss and/or beam manufacturer shall provide shop drawings showing recommended
design. Design loads per applicable local codes and connection details signed and sealed by a
registered professional engineer.
Forced air heating. All ductwork shall be located above basement ceiling line whenever
possible.
Size main hvac trunk -line to allow a T-O" minimum finish ceiling in basement areas ducts pass
through per [PC R305.
Furnace shall not be used prior to completion Of house unless approved by owner.
Owner/Contractor shall assure that all duct registers and furnace are clean and free of
construction materials.
Provide waterproof sheetrock in tub, shower and laundry areas per IRC R307.2.
Vent dryer and bathroom exhaust fans to exterior of house per IRC R303.3.
Case and (jamb all finished door openings.
Interior and/or exterior railings required at porch or landing will conform to IRC R312.
Engineered joist floor systems shall be installed per manufacturer specifications.
Provide proper gutter systems over all walks, driveways, porches or decks as indicated on plans.
Install 6" of clean gravel in all window wells.
Finish grade the lot to slope a minimum of6" in the first 10 feet away from the foundation,
then minimum 2% thereafter per IRC R401.3.
Mix, place, consolidate and cure all concrete per IRC R403 & R404.
All smoke detectors shall be 110V main power with battery backup. All detectors to be
connected for simultaneous alarm. Smoke alarms per IRC R313.
Dimensions are to framed walls without sheetrock unless specified otherwise.
f
Southfork Design Group L�LC
Rexburg, ID
208-356-4488
4
FOUN DAT10N NOTES "
All footings shall bear on undisturbed soil or compacted fill capable of supporting a minimum
design bearing pressure of 1500 PSF.
Footing elevations shown on the foundation plan, shall be lowered as required to obtain the
required design bearing pressure.
Unless noted otherwise, the bottom of all exterior footings shall be placed 6" below local frost
depth: the bottom of all interior footings shall be placed 12" minimum below interior finished
grade.
Concrete foundation shall be cast in accordance with the requirements of MC Section R402.
Slab on grade construction shall be in accordance with IRC R506.
STRUCTURAL NOTES
The structural drawing shall be used in conjunction with the drawings ofall other disciplines
and the project specifications. The contractor shall verify the requirements ofthe other trades
as to sleeves, chases, hangers, inserts, anchors, holes and other items to be placed or set In the
structural work.
The Owner/Contractor shall be responsible for complying with all safety precautions and
regulations during the work. The engineer will not advise on nor issue direction as to safety
precautions and programs.
The structural drawings herein represent the finished structure. The Owner/Contractor shall
provide all temporary guying and bracing required to erect and hold the structure in proper
alignment until all structural work and connections have been completed. The investigation,
design, safety, adequacy and inspection of erection bracing, shoring, temporary supports, etc.
are the sole responsibility ofthe Owner/Contractor.
The engineer shall not be responsible for the methods, techniques and sequences of procedures
to perform the work. The supervision ofthe work is the sole responsibility of the
Owner/Contractor.
Drawings indicate general and typical details of construction. Where conditions are not
specifically shown, similar details of construction shall be used, subject to approval by the
engineer.
Loading applied to the structure during the process of construction shall not exceed the safe
Ioad-carrying capacity ofthe structural members. Do not apply any construction loads until
structural framing 15 properly connected together and until all temporary bracing is in place.
Southfork Design Group LZC
Rexburg, ID
208-356-4488
All ASTM and other references are per the latest additions ofthe standards, unless otherwise `
noted.
WOOD FRAMING NOTES
All wood framing material shall be surfaced dry and used at 19% maximum moisture content.
All stud and wall fr-aming shall be No. 2 grade Doug Fir.
All joist, rafter, & misc. framing shall be No. 2 grade Doug Fir. Unless noted otherwise.
All framing exposed to the weather or in contact with masonry or concrete shall be pressure
treated in accordance with the American Wood Preservers Association Specification where
possible.
Provide LVL header beams ofthe same size as joists or rafters to frame around openings in the
plywood deck unless otherwise indicated.
BOIL -holes shall be carefully centered and drilled not more than 1116" largerthan the bolt
diameter. Bolted connections shall be snug but not to the extent ofcrushing wood under
washers.
Prefabricated metal joist hangers, hurricane clips, hold-down anchors and other accessories
shall be as manufactured by "Simpson Strong -Tie Company", or approved equal. Install all
accessories per the manufacturer's requirements. All steel shall have a minimum thickness of
0.04 inches (per ASTM A446, Grade A) and be galvanized (coating G60).
Holes and notches drilled or cut into wood framing shall not exceed the requirements of IRC
R600.
All plates, anchors, nails, bolts, washers and other miscellaneous hardware permanently exposed
to weather shall be hot dip galvanized.
Sheathing of floors, walls and roofs shall be in accordance with IRC R500, R600 and R800.