HomeMy WebLinkAboutCOMPLIANCE CERTIFICATE - 06-00516 - Dental Health Center - AdditionOct 17 2006 4:33PM Sundberg & Hssociates, In 208-522-6928 P.1
0600516
Dental Health Center Addition
CQMcheck Software Version 3.1 Release i
Envelope Compliance Certificate
2003 IECC
Report Date: 10/17/06
Data fllename: C:1Documents and SettingsljeffgolMy DocumardsIDOUG SMITFAC.OMcheck.cck
Section 1: Project Information
Project Title: Dental Health Center - Building Addition
Construction Sim:
56 Professional Way
Rexburg, ID 83440
Dwner/Agent:
doug Smith DOS fafd
Dental FleaBh Center
56 Professional Plaza
Rexburg, ID 83440
366-3133
Section 2: General Information
Building Location (forweather data):
Rexburg, Idaho
Climate Zone:
18
Hoating Degree Days (base 65 degrees F):
8693
Cool8lg Degree Days (base 65 degrees F):
143
Project Type:
Addition
Glazing Area Percentage:
16%
Bulldlna Tree
Floor Area
Medical and Cliru®I Cale
1633
Section 3: Requirements Checklist
Des igner/Contractor'
Newell Goldsbo0y
Sundoernnd Associates, Ira:.
111 East 1661 Street
Idaho Falls, ID 83404
5226901
sundberg@lda.net
J 11
OCT 2 0 ZOOG , s�
CITY OF REXPI
Climate -Specific Requirements:
Component NamelDescriptlon
Gross Area
Cavhy
Cont.
Proposed
Budget
or
R-Value
R-Value
U-Factor
U-Factor
Perimeter
Roof 1: All -Wood JoisttRafter/huss
1633
28.0
D.0
0.038
0.D47
Exlenor Well 1: Wood Frame, Any Spacing
48
21.0
0.0
0.D62
D.067
Exterior Wall 2: Wood Frame, Any Spacing
243
21.0
0.0
0.D62
D.087
Wndrnv 1: Vinyl Frame: Double Pane With Lev-E, Tinted, SHGC 0.35
a4
—
•-
0.370
0.520
Exterior Wall 3: Wood Frame, Any Spacing
424
21.0
0.0
0.062
0.067
Window 2: Vinyl Frame:Double Pane with Low-E. Tinted, SHGC 0.35
80
---
—
0.370
0.520
Door'.: Solid
24
---
--
0.150
0.112
Exterior Wall 4: Wood Frame, Any Spectra
256
21.0
0.0
0.062
O.D67
'Window 3: Vinyl Freme:Double Pane with Low-E, Tinted, SHGC 0.35
60
--
--
0.370
0.520
Exterior Wa0 5: Wood Frame, Arty Spacing
410
21.0
0.0
0.062
0.067
Window 4: Vinyl FrameMouble Pane with Low-E, Tinted, SHGC 0.35
40
—
--
0.370
0.520
Basement Wall 1: Solid Concrete or Masonry «8", Furring: Wood,
840
21.0
0.0
- 0.083
0.091
Wall.Ht 10.0. Depth B.G. 8.0
Dental Health Center - Building Addition - PwA 1 of 2
Oct 17 2006 4:33PM Sundberg & Associates, In 208-522-6928
•
l�J
(a) Budget U-factors are used for software baseline calcu€adons ONLY, and are not code requirements.
Air Leakage, Component Certification, and Vapor Retarder Requimments:
❑ 1.
Ad joints and penetrations are caulked, gasketed, weatw-stripped, or otherwise sealed.
❑ 2.
Windows, doors, and skylights cedifted as meeting leakage requirements.
❑ 3.
Component R-values & U4bdara laheled as cert[W.
❑ 4.
Stair, elevator shaft vents, and other dampers integral to the budding envelope are equipped with motorized dampers.
❑ 5.
Cargo doors and loading dock doors are weather seated.
❑ &
Recessed [Ighttrg fixtures are: (I) Type IC rated and seeded or gasladed; or (o) Installed inside an appropriate sir -Malt
assembly with a 0.5 Inch cieanum from combustible materials and with 3 Inches clearance from Insulation material.
❑ 7.
Building entrance doors have a vestibule and equipped with dosing devices.
Excepflbr:s:
Building entrances with revolving doors.
Doors that open directly from a space less than 3000 sq. ft. in area.
0 8.
Vapor retarder installed.
Section 4: Compliance Statement
Compliance SMement. The proposed envelope design represented In this document is consistent with the budding plans,
speclticatt ns and other calculadons submitted with application. The proposed envelope system has been designed to
meet the 200i3 IECC requirements In COMch ers1cin 3.1 ease i and bo comply with the mandatary requ€rernenb In the
Requirements Checklist. l I
97A
ncipal rnelo ' es€gner- ame S6g afore �! Date
Project Notes: - V
COMcheck If for the eddtion shell only. Existing building Ilghttng and mechanical systems are existing and will not be changed or
modified.
Dental Health Center - Building Addition Page 2 of 2
p.2