Loading...
HomeMy WebLinkAboutJOIST - 06-00513 - 284 Mark Ave - New SFRA complete TJ-Xpert framing plan squires the Trus Joist Framer's Pocket L• .e See Trus Joist Framer's Pocket Guide for Product Trademark Information I LEVEL NOTES I File Name: 34-R7 Investments Mark St.JOB Level Name: Main Level Plotted: 10/2/2006 13:34 Design Status: Main Level ... 10/2/2006 13:32 NOTE: Level design times indicated above provide assurance for proper level stacking. Design Methodology: ASD Floor Area Loading Is: 40psf Live Load and 15 psf Dead Load Maximum Joist Deflection: U480 Live Load L/240 Total Load TJ -Pro Rating Information: Weighted Average: 47 Lowest Rating: 37 Highest Rating: 67 Glued d Nailed Decking is Required Direct Applied Ceiling is Not Required Floor Decking: 23/32" Panels (24" Span Rating) Normal O.C. Spacing = 16"* *Unless noted otherwise Scale: 1/8" = 1' WL 0 OCT 1 7 2006 CITY OF RFXBUR a Cill[JAXPIrt. 15;%)WOD HANGER LIST - Simpson Strong -Tie Company, Inc.® Plot ID Qty Product Label Top Nails Face Nails Member Nails Notes H1 33 IUT11 10-N30 2-N10 H2 3IUT9 8-N10 2-N10 H3 1 HUS1.81/10 30-10d 10-10d DS Hanger Notes: JOB COMMENTS 34-R7 Investments Mark St. DB -87 CREATED BY BMC West P.O. Box 1831 Idaho Falls, ID 83403 (208)557-5056 FAX: (208)529-3610 SYMBOL LEGEND O Point Load Line Load Area Load O Detail Callout Label (See Framer's Pocket Guide) Required Bearing Length in inches (Adequate bearing has been provided if bearing length Is not indicated.) 1 of 1 FOR THE TJ-XPERT WARRANTY SEE FRAMER'S POCKET GUIDE Preliminary Layout for Review and Approval TJ-Xpert 6.42 (9693) 06.42 D6.42 S6.42 P6.42 JOIST AND BEAM LIST Plot ID Length Product Plies Qty A32 32' 117/8" TJI 110 ,foist 1 12 A30 30' 11 7/8" TJI 110.1oist 1 5 A24 24' 117/8" TJI 110.1oist 1 11 A20 20' 11 7/8" TJI 110,loist 1 3 A18 18' 117/8" TJI 110.loist 1 11 A8 8' 117/8" TJI 110 joist _ '1 9 A4 4' 117/8" TJI 110.1oist 1 5 M1 18' 1 3/4!'x 117/8" 1.9E Microllom LVL 1 1 M2 14' 1 3/49x 117/8" 1.9E Microllam LVL 1 1 M3 14' 13/4" x 117/8" 1.9E Microllam LVL 2 2' M4 S' 13/4" x 117/8" 1.9E Microilam LVL 1 2 ACCESSORIES LIST Rml 16' 11/4" x 117/8" 1.3E TimberStrand LSL 1 12 Ski V 2 1/4" 117/6" TJI 110 Blocking Panels 1 8 Bkl* V 5 1/2" 117/8" TJI 110 Blocking Panels 1 1 Shl 4' x 8' 23/32" Panels (24" Span Rating) 1 49 Bk*, Random length blocking panel cuts Bk, Blocking Panels; Rm, Rim Board JOB COMMENTS 34-R7 Investments Mark St. DB -87 CREATED BY BMC West P.O. Box 1831 Idaho Falls, ID 83403 (208)557-5056 FAX: (208)529-3610 SYMBOL LEGEND O Point Load Line Load Area Load O Detail Callout Label (See Framer's Pocket Guide) Required Bearing Length in inches (Adequate bearing has been provided if bearing length Is not indicated.) 1 of 1 FOR THE TJ-XPERT WARRANTY SEE FRAMER'S POCKET GUIDE Preliminary Layout for Review and Approval TJ-Xpert 6.42 (9693) 06.42 D6.42 S6.42 P6.42