Loading...
HomeMy WebLinkAboutSTAFF REVIEW - Henderson Subdivision - Annexation & Rezone to R1 & HDR212/24/2001 Kurt Rowland Forsgren Engineering 350 North 2nd East Rexburg, Idaho 83440 Dear Kurt, STATE OF IDAHO www.ci.rexbura.jd.us I H��cb�,-c �.e•� P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 e-mail rexburg@ci.rexburg.id.us I have reviewed the plans for the Henderson Subdivision and have identified the following discrepancies: 1. Identify storm drain details. Show on plan and profile. Include catch basins and any necessary details. 2. Provide sanitary sewer plan and profile for 1500 West. Include pressure line. Identify the details of the connection to existing lines to the North of the property. 3. Reconfigure sewer main from the corner of Polo Drive and Johnson Avenue to 1500 West so that the City of Rexburg can access the manholes. 4. With the exception of the line in Johnson Avenue, change all sanitary sewer lines from 10" to 8". 5. Change the slope of the 8" sanitary sewer lines from 0.28% to 0.30% minimum. 6. The minimum allowed for gutter slope is to be 0.30%. Please make the necessary changes. 7. Provide open street access instead of valley gutter at Henderson Avenue access to 5`h West. 8. Show full street construction of Seagull Drive. 9. Change valley gutter detail from 3' to 5' minimum width. 10. Provide Geo -textile Fabric under street sub -base unless applied directly on gravel. 11. Identify locations of handicap ramps on plans. 12. Use existing connections at water line where possible. See water plans for Comfort Inn. 13. Provide curb stop at each service line. Meters to be installed as homes are built. 14. Change Detail B on page DT -2 to show asphalt ring instead of concrete ring around gate valve. 15. Provide manhole adjustment detail. 16. Identify location and size of service lines to the lots. Show extending to 5' beyond back of walk. Identify how they will be marked in field. 17. Provide and show monuments as per Rexburg Subdivision Ordinance. 18. Provide lighting plan. 19. Identify existing electrical, telephone, gas, etc. lines. Show defined locations of new utilities. Including gas, power, phone, T.V. and communications. The Fire Department has not finished their review of the plan and may have additional requirements. Please provide me with 2 new copies of the corrected plans. If you have any questions, please give me a call at 359-3020 ext. 324. Sincerely, Val Christensen Building Official C.C. John Millar Chris Huskinson