HomeMy WebLinkAboutFIRE RESISTANCE MANUAL PGS - 02-00016 - College Park Apartments15th
Edition
7
GYPSUM
ASSOCIATION
12
RESISTANCE
DESIGN
MANUAL
SOUND CONTROL
GYPSUM
SYSTEMS
Jul 11 02 05:30p WESTERN WHOLESRLE 208 523 0128
SYSTEM DESCRIPTION
GLASS MAT GYPSUM BOARD, WOOD STUDS
One layer s/<proprietary type X glass mat water-resistant gypsum backing board applied
parallel or at right angles to 2 x 4 wood studs 16" O.C. with phosphate coated nails, 1'A'
long,'/; diameter cupped heads, 8" o.c.
I Joints staggered 16" on opposite sides and covered with 10x10 mesh glass tape and
the adhesive. (LOAD-BEARING)
i
PROPRIETARY GYPSUM BOARD
G -P Gypsum %" Dens -Shield® Fireguard®
i
GA FILE NO. WP 3620
GYPSUM VENEER BASE, GYPSUM VENEER PLASTER,
WOOD STUDS
e layer'/i' type X gypsum veneer base applied at right angles to each side of 2 x 4
woody studs l6" o.c. with 5d etched nails, 1314 long, 0.099" shank,'!,"heads,
gypsum veneer plaster applied over each face.
Vertical joints staggered 16' and horizontal joints 12" on opposite sides. Sound tested
without gypsum veneer plaster. (LOA"EARING)
i
GA FILE NO. WP 3640
GYPSUM WALLBOARD, WOOD STUDS
one layer Its' type X gypsum wallboard or gypsum veneer base applied parallel or at
right angles to each side of either 2 x 3 or 2 x 4 wood studs, turned flatwise, 24" o.c.
with fill cement -coated nails, 1'/e" long, 0.0915" shank, 'A" heads, 7" o.c. (NLB)
GA FILE NO. WP 3641
GYPSUM WALLBOARD, WOOD STUDS
Base layer s/." type X gypsum wallboard or gypsum veneer base applied parallel or at
right angles to each side of either 2 x 3 or 2 x 4 wood studs, turned flatwise, 24" o.c. with
6dicemant-coated nails, 14." long, 0.0915"shank, '/: heads.7 o.c. Face layer s/.'type
X gypsum wallboard or gypsum veneer base applied parallel or at right angles to each
side with 8d cement -coated nails, 23/e" long, 0.113'shank, '/a. heads. 8" o.c. (LOAD.
BEARING)
p.2
SKETCH AND DESIGN DATA
Thickness: 4s4'
Approx. Weight: 7 psi
Fire Test: WHI-495-0853,5-14.87;
WHI.495-0854, 5.15-87
Sound Test: See WP 3605 (OR 64-8,
2.4.64)
1 HOUR 1130 to 34 STC
FIRE SOUND
® rev
Thickness: 41/a"
Approx, Weight: 7 psi
Fire Test; UC, 1-12.66
Sound Test: G&H 0I.35FT. 5.26.64
1 HOUR
FIRE
Thickness: 2'/e'
Approx. Weight: 7 psi
Fire Test: UL, 9.12.96. Design U338
1 HOUR
FIRE
Thickness: 4'/a'
Approx. Weight: 12 psi
Fire Test: UL, 9.12.96, Design U336
56 ' Contact the manufacturer for more detailed GA - 600 - 97
Information on proprietary products.