HomeMy WebLinkAboutCONCRETE TEST 23 - The Grove at Thomson FarmsFile name:
20001SB05262021EJB
4C99D895-750F-4881-8B45-083B763D6D31 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
20001
Cumulative Test Load Amount:
Project Name:
The Grove
Test Location:
Client:
Stillwater Equity Partners
Admixtures:
Ticket Number:
278068
Contractor:
Supplier:
Mix Number:
Date:
Cylinder Log #:
158
Field Test Results:
Set #:
4
Slump
(inches):
9.2
Slump
Maximum
(in):
Entrained Air
(%):
1.50
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
61
Ambient
Temperature
(°F):
40
Unit Weight
(PCF):
146.91
Tested By:
Date:
Picked Up By:
Leland Steiner
Date:
4/28/2021
Time:
9:45 AM
Max, Min Temperature
Unknown
Previous Test Results:
Cylinder
ID:
Break Age:Break
Date:
Diameter
(in):
Area
(in^2:
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/5/2021 4.00 12.56 40875 3254.38 3,000.00 158
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/26/2021 4.00 12.6 58,840.0 4669.8 3,000.0 Type 4
C 28 5/26/2021 4.00 12.6 57,255.0 4544.0 3,000.0 Type 6
D 28 5/26/2021 4.00 12.6 59,385.0 4713.1 3,000.0 Type 6
Second Break Average:
4642
Date:
05/26/2021
Reviewed By:
E. Vail
Signature: