HomeMy WebLinkAboutSTAFF REVIEW - BYUI - Student Married Housing12/17/2002 Randy Hayes JHS Architects 125 North Garfield Pocatello, ID 83204 Dear Randy, edy 01 ILtCi W1.Vl/a W/ STATE OF IDAHO www.cj.rexburgJd.us P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 e-mail rexburg@ci.rexburg.id.us I have reviewed the plans for the BYU Student Family Housing and have identified the following discrepancies or questions: 1. The plans show sidewalk located at back of curb. Please include a 7' wide landscape strip (minimum) between the curb and the sidewalk as per City of Rexburg Ordinance. 2. Driveway approaches must be constructed to City of Rexburg standards. Please identify all driveway approaches onto city streets as being constructed of 6" thick concrete with "4 rebar spaced a minimum of 18" on center in both directions. The curb at the approach must be constructed with 2 # 4 rebar. Please make the necessary additions to the plans. 3. Identify a handicapped ramp as per City of Rexburg standard details at the corner of 7a' South and 2°d West. 4. Please provide us with stone drainage calculations. 5. Section 1 t07.6.2.1 of the 2002 Supplement of the 2000 International Building Code (IBC) states that "at least 2%" of the dwelling units shall be Type A units. The plans are for 156 units. Therefore, at least 4 units must be Type A units. The plans call out only 3 Type A units. 6. The plans make note that in some cases the foundation may be anchored to bedrock. If this takes place above the frost line, all dirt must be cleaned from the bedrock prior to the placement of concrete. Please make not of this on the plans. 7. Identify location of hold-downs, straps, collectorhie and shear walls as per the tables on page A3.3. 8. Please identify entrance doors to the dwelling units as being 20 -minute rated assemblies. 9. The bathroom doors on some of the units open into the 30" x 48" minimum clear space required at the bathtubs. I have attached a copy of bathroom details from the Fair Housing Act Design Manual. Please make the necessary changes to the plans. 10. Please provide truss details as soon as you can but prior to frame inspection. 11. I have attached a copy of the Fire Department review to the back of this document. Please provide me with 2 new stamped copies of the corrected plans. If you have any questions, please give me a call at 359-3020 ext. 324. Sincerely, Val Christensen Building Official C.C. John Millar Chris Huskinson additional inaccessible receptacle permitted receptacle required in an accessible location lever handles— not required, but recommended 0 - fixed base cabinet acceptable since parallel approach centered on basin is possible 30" X 48" clear floor space for parallel approach 7.36 PART TWO: CHAPTER 7 FAIR HOUSING ACT DESIGN MANUAL reinforced wall areas for future installation of grab bars around toilet and bathtub c.� O Example "A" Bathroom 9'- 4" X SF -21' (See plan page 7.66) clear floor space at each fixture required 30" X 48" min. clear floor space outside swing of door required; in this plan the clear floor space doubles as the space for access to bathtub.Toilet beside and close to bathtub allowed in "A" bathroom only. Provides less access to bathtub and controls. Notes in italic type are recommendations only and are not required by the Guidelines. REXBURG MADISON COUNTY FIRE DEPARTMENT P.O. Box 280 26 North Center Rexburg, Idaho 83440 (208) 359-3010 2000 INTERNATIONAL FIRE CODE Plan Date: 11-15-02 Plan Review Review Date: 12-17-02 Building Name: BYU-I MARRIED STUDENT HOUSING Building Address: SECOND WEST AND SEVENTH SOUTH Stories: 2/3 STORY Type of Construction: VB Occupancy Classification: R-2 Existing Floor Area: N/A New Construction Floor Area: APPROXIMATELY 9684 SQUARE FEET/BUILDING 1).Required Fire Flow (Table B105.1): 2750 GPM/TWO HOURS Comments: REQUIRED FIRE FLOW WILL BE REDUCED TO 1500 GPM/TWO HOURS WITH THE INSTALLATION OF AN AUTOMATIC FIRE SPRINKLER SYSTEM INSTALLED. 2).Water Supply (Article 9, Section 903) Required: YES Fire Hydrant Location: EXISTING C-63 9 NEW HYDRANTS PROPOSED Fire Hydrant Flows: EXISTING OKAY, PROPOSED UNKNOWN Fire Flow Test Location: C-63 Fire Flow Supplied By: FD Other Approved Water Source: NONE Water Supply Acceptable: SEE COMMENTS Fire Hydrant Location Acceptable: YES Water Supply Comments: FLOWS FROM PROPOSED HYDRANTS UNKNOWN. FD REQUIRES AN ESTIMATED HYDRANT FLOW (FROM AN ENGINEER) OF EACH HYDRANT TO BE SUBMITTED PRIOR TO CONSTRUCTION. 3.)Fire Apparatus Access Roads (Article 9 Section 902) Required: YES Acceptable: Width: X Length: X Surface: X Turning Radius: X Grade: X Vehicle Vertical: UNKNOWN Clearance: X Turn Arounds: X Complete Road Acceptable: YES, SEE COMMENTS Comments: DEPENDING UPON FINAL CONFIGURATION, FIRE LANE SIGNAGE AND PAINTING AND MAINTAINING THE CURBS MAY BE REQUIRED. 4).Access Roads and Water Supply, Including Fire Hydrants Are Required To Be Installed And Made Serviceable Prior To And During Time Of Construction (Article 9 Section 901.3): YES Comments: IF ACCESS ROADS AND OPERATIONAL FIRE HYDRANTS ARE NOT INSTALLED PRIOR TO CONSTRUCTION A STOP -WORK WILL BE ISSUED. 5),Installation Of Portable Fire Extinguisher (Article 10 Section 1002) Required: YES Location Acceptable: NOT SHOWN Type Provided Acceptable: MINIMUM SIZE SHALL BE 2A10BC Comments: PROVIDE AT LEAST ONE FIRE EXTINGUISHER PER UNIT OF THE REQUIRED SIZE OR LARGER MOUNTED IN A CENTRAL LOCATION. 6).Automatic Fire Extinguishing Systems: (Article 10 Section 1003) Required: YES Type Of System Being Installed: WET Sprinkler System Monitoring Required (Article 10 Section 1003.3) Required: YES Comments: 7).Standpipes (Article 10 Section 1004) Required: NO Type Required: Comments: 8) Ventilating Hood And Duct. Fire Extinguishing System (Article 10 Section 1006.2) Required: NO Type Being Provided: Comments: NONE 9) Fire Alarm Systems (Article 10 Section 1007)Required: YES Type Of System Required: Manual: Automatic: Both: X Type Of System Being Provided: Manual: Automatic: Both: X Components Of System Shown: Smoke Detectors: X Heat Detectors: Manual Pull Station: Sounding Devices: .X Visual Devices: X Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: NO, SEE COMMENTS Comments: SMOKE DETECTORS SHALL ALL BE HARDWIRED WITH BATTERY BACKUP. HANDICAP UNITS REQUIRE SMOKE DETECTORS TO BE HARDWIRED INTO THE FACP. WITHIN TYPE 3B AND 3C UNITS SMOKE DETECTOR IS MISSING FROM THE THIRD BEDROOM. PLANS INDICATE ONLY HORNS IN THE UNITS, PLEASE REPLACE WITH COMBINATION HORN/STROBE UNITS AS REQUIRED BY ADA. WITHIN TYPE 2T UNITS PLANS INDICATE ONE HORN IN DOWNSTAIRS PORTION OF UNIT. NFPA 72 REQUIRES HORN/STROBE UNIT TO BE WITHIN 16 FEET OF PILLOWS IN EACH BEDROOM. PLANS SHOW NO PULL STATIONS, PLEASE EXPLAIN. FIRE ALARM PLANS NOT COMPLETE. IFC REQUIRES CONSTRUCITON DOCUMENTS THAT INCLUDE ALARM CONTROL AND TROUBLE SIGNALING EQUIPMENT, ANNUNCIATION, POWER CONNECTION, BATTERY CALCULATIONS, CONDUCTOR TYPE AND SIZES, VOLTAGE DROP CALCULATIONS, MANUFACTURERS, MODELS NUMBERS AND LISTING INFORMATION FOR EQUIPMENT, DEVICES AND MATERIALS, AND THE INTERFACE OF FIRE SAFETY CONTROL FUNCTIONS. Plans As Submitted Are Acceptable: NO Plans Checked By: CHRIS HUSKINSON Date: 12-17-02 Please furnish comments back to the plan reviewer in the following manner: Written Comments: X New Plans: X