Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SHORT FORM - 06-00475 - 495 Woodbridge St - New SFR
Short r--orm �*+ Job: NICK AND MARCIE JEN... Date: Sep01,2006 Entire House By: TRAVIS KAUER ELECT... 0 TRAVIS KAUER ELECTRIC, LLC 10656E 145 N, RIGeV, ID 83442 Phone: 206313-0061 Fax 206-227-0421 Email: lkelec®Id+ 0600475 Project Infor For. BROS CONCRETE, LLC 495 Woodbridge St -Jensen 3847 E 800 N, RIGBY, ID 83442 Phone:208-317-4160 Design Information Ht9 Clg Infiltration Outside db ('F) -6 89 Method Simplified Inside db (OF) 70 75 Construction quality Semi -loose Design TO (OF) 76 14 Fireplaces 0 Daily range - H Inside humidity (a/n) 50 Moisture difference (gr/Ib) -31 HEATING EQUIPMENT Make AmStd Trade Freedom 90 Single Stage Model AUX1B060A9361A* Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE 60000 Btuh 56000 Btuh 62 OF 976 cfm 0.027 cfm/Btuh 0.70 in H2O COOLING EQUIPMENT Make AmStd Trade American Standard 13 Cond 2A7B3018A1 Coil 2TXCA018AC3 Efficiency 13 SEER Sensible cooling 16300 Btuh Latent cooling 0 Btuh Total cooling 16300 Btuh Actual airflow 976 cfm Air flow factor 0.085 cfm/Btuh Static pressure 0.70 in H2O Load sensible heat ratio 1.00 ROOM NAME Area (ft2) Htq load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Room1 736 5268 750 141 63 Room2 280 3248 456 87 39 Room3 80 837 347 22 29 Room4 200 2224 857 60 72 Rooms 192 1750 264 47 22 GARAGE 44W 0 0 0 0 Room7 88 5113 2768 137 234 RoomB 383 4547 1546 122 131 Room9 156 3373 1191 90 101 Room10 168 2907 1057 78 89 Room11 289 4786 1372 128 116 Room12 120 1703 819 46 69 Room 13 60 714 117 19 10 o __._4A An n n n n %00m IY 14 Printout certified by ACCA to meet all requirements of Manual ,� wnghtsoft Right-SuileResidential 6.0.79RSR40835 ACCR C9My Doc=eMsffinghtsoft FiVAC\BROS CONCRETE NICK AND MARCIE JENSEN.rP Caic=MJ6 Onentalon 200GSep-04 063 :12 P e1 CITY OF REXBURG Entire House Other equip loads Equip. @ 0.94 Latent cooling TOTALS d 3402 36472 11544 976 976 13340 4164 RSM 14765 0 3402 ' 49812 ' 14765 ' 976 ' 976 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. +- wrightsoft RIghtSude Residential 6.0.79 RSR40835 2006-Sep-0408:35:12 ZukCAMy Docurnenis\Wrightson WAMBROS CONCRETE NICK AND MARCIE JENSEN.ap Celc=MJB Orientation Paget C6dent Constructions Job: NICK AND MARCIE JEN. om.. � Date: Sep 01, 2006 ► Entire House By: TRAVIS KAUER ELECT... TRAVIS KAUER ELECTRIC, LLC IM56 E 145 N, RIGBY, ID 83442 Phone: 208313-0081 Fm 208-227-0421 Email: lkelec@ida.net For. BROS CONCRETE, LLC 3847 E 800 N, RIGBY, ID 83442 Phone:208-317-4160 Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (OF) 70 75 Elevation: 4741 ft Design TD (OF) 76 14 Latitude: 44ON Relative humiddity N 50 50 Outdoor: Heating Cooling Moisture difference (grilb) 61.5 -31.5 Dry bulb (OF) -6 89 Infiltration: Daily range (OF) - 34 ( H) Method Simplified Wet bulb (OF) - 60 Construction quality Semi -loose Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain (W) (Btuh/V--TF (a'Tfflhh) (Dh M) pub) (Btu,m•) (Btih) Walls 12F-Osw Wood stud frame, siding or stucco, no board insulation, n 399 0.065 21.0 3.26 1299 0.31 125 R-21 cavity insulation a 436 0.065 21.0 4.94 2154 0.47 207 s 423 0.065 21.0 3.35 1418 0.32 136 w 452 0.065 21.0 2.84 1284 0.27 123 all 1710 0.065 21.0 3.60 6155 0.35 591 15B11-Owo.6: Basement- 8" concrete, wood framing, interior finish, n 300 0.056 11.0 4.78 1434 0.05 16 R-11 cavity, no board insulation, 6' a 367 0.056 11.0 4.91 1801 0.07 25 s 336 0.056 11.0 5.07 1705 0.08 28 w 392 0.056 11.0 5.07 1989 0.08 33 all 1395 0.056 11.0 4.97 6927 0.07 102 Partitions 12F-Osw. Wood stud frame, siding or stucco, no board insulation, 192 0.065 21.0 4.94 948 0.00 0 R-21 cavity insulation Windows 61A: VINYL LOW E, clear: NFRC rated (SHGC=0.31) n 78 0.350 0.0 26.6 2075 10.8 841 n 36 0.350 0.0 26.6 958 10.8 388 e 16 0.350 0.0 26.6 426 33.9 543 e 25 0.350 0.0 26.6 665 33.9 848 s 54 0.350 0.0 26.6 1436 18.8 1018 all 209 0.350 0.0 26.6 5559 17.4 3638 Doors 11 DO: Wood door, solid core, no storm n 21 0.390 0.0 29.6 622 7.22 152 s 21 0.390 0.0 29.6 622 7.22 152 all 42 0.390 0.0 29.6 1245 7.22 303 Ceilings 16B-38ad: Ceiling under vented attic, no radiant barrier, dark 1134 0.026 38.0 1.27 1435 0.70 793 shingles, R-38 insulation 16A-38ad: Ceiling under unvented attic, no radiant barrier, dark 174 0.026 38.0 1.98 345 1.61 281 shingles, R-38 insul. 166R-38ad: Ceiling under unvented attic, radiant barrier, dark 676 0.026 38.0 1.98 1336 1.09 738 shingles, R-38 insul. ,g_ wrrghtsoft Right-Sude Residential 6.0.79 RSR40835 200&Sep-0408:35:12 ff /I KC:1My DocunentAWnghtsoft FNAC\BROS CONCRETE NICK AND MARCIE JENSEN.rrp Calc=MJB Onentation Page .. Floors 20P-30c: Carpeted floor over open crawl/garage, R-30 blanket insulation 21A-24t: Tile covered basement floor, No insulation, 24' wide 18 0.035 30.0 2.66 48 0.07 1896 0.025 0.0 1.49 2827 0.00 !�%7- vvnQhtsoft Right-Suae Residential 6.0.79 RSR40835 200GSeµG408:35:12 )IM C:1My Docunents\Wrghtsoft HWAC\BROS CONCRETE NICK AND MARCIE JENSEN.rry Calc=MJ6 Orientation Paget Project Summary �*d oo Poi 2DMARCIEJEN... 006 Entire House By: TRAVIS KAOER ELECT... TRAVIS KAUIER ELECTRIC, LLC 10856E 145 N, RIGBV, ID 83942 Phone: 208-313-Ml Fax 20&227-0421 Email: tkelecawa.nel Project• • For. BROS CONCRETE, LLC 3847 E 800 N, RIGBY, ID 83442 Phone: 208-317-4160 Notes: Weather: Winter Design Conditions Outside db -6 'F Inside db 70 'F Design TO 76 'F Heating Summary Structure 36472 Btuh Central vent (190 cfm) 13340 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 49812 Btuh Infiltration Idaho Falls, ID, US Method Simplified Construction quality Semi -loose Fireplaces 0 He 2�9 Area (ft') 2Coo19n_g Volume (fte) 16818 16818 Air changes/hour 0.49 0.25 Equiv. AVF (cfm) 137 70 Heating Equipment Summary Make AmStd Trade Freedom 90 Single Stage Model AUX1B060A9361A` Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE 60000 Btuh 56000 Btuh 62 OF 976 cfm 0.027 cfm/Btuh 0.70 in H2O Summer Design Conditions Outside db 89 OF Inside db 75 OF Design TD 14 OF Daily range H Relative humidity 50 % Moisture difference -31 gr/Ib Sensible Cooling Equipment Load Sizing Structure 11544 Btuh Central vent (190 cfm) 2457 Btuh Blower 1707 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Equipment sensible load 14765 Btuh Latent Cooling Equipment Load Sizing Structure 1340 Btuh Ducts 0 Btuh Central vent (190 cfm) Equipment latent load -3416 0 Btuh Btuh Equipment total load 14765 Btuh Req. total capacity at 1.00 SHR 1.2 ton Cooling Equipment Summary Make AmStd Trade American Standard 13 Cond 2A7B3018A1 Coil 2TXCA018AC3 Efficiency Sensible cooling Latent cooling Total cooling Actual airflow Air flow factor Static pressure Load sensible heat ratio 13 SEER 16300 Btuh 0 Btuh 16300 Btuh 976 cfm 0.085 cfm/Btuh 0.70 in H2O 1.00 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. G1 wrigHtsoft Right-SuBe Residential 6.0.79 RSR40835 2006-Sep-0408:35:12 �y CAMy Docments\Wrightsott WAC1BROS CONCRETE NICK AND MARCIE JENSEN.np Calc=MJB Orientation Pagel Job #: NICK AND MARCIE JENSEN Performed by TRAVIS KAUER ELECTRI... BROS CONCRETE, LLC 3847 E 800 N RIGBY, ID 83442 Phone: 208-317-4160 Main floor cfm TRAVIS KAUER ELECTRIC, LLC 10856 E 145 N RIGBY, ID 83442 Phone: 208-313-0081 Fax: 208-227-0421 tkelec@ida.net Scale: 1 : 104 Page 1 Right -Suite Residential 6.0.79 RSR40835 2006-Sep-04 08:35:38 CAMy Documents\Wrghtsofl h Job #: NICK AND MARCIE JENSEN Performed by TRAVIS KAUER ELECTRI... BROS CONCRETF- LLC 3847 E 800 N RIGBY, ID 83442 Phone: 208-317-4160 Basement TRAVIS KAUER ELECTRIC, LLC 10856 E 145 N RIGBY, ID 83442 Phone: 208-313-0081 Fax: 208-227-0421 tkelec@ida.net Scale: 1 : 104 Page 2 Right -Suite Residential 6.0.79 RSR40835 2006-Sep-04 08:35:38 Dom men is\W righ tsoft H VAC\.. Duct Sy/stem Summary Job: NICK AND MARCIE JEN... Date: Sep01,2006 Entire House By: TRAVIS KAUER ELECT... 0 TRAVIS KAUER ELECTRIC, LLC 10856 E 145 N, RIGBY, ID 83442 Phone: 208-313-0081 Fax 2043-227-0421 Email: tkelec@ida.net For. BROS CONCRETE, LLC 3847 E 800 N, RIGBY, ID 83442 Phone: 208-317-4160 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.70 in H2O 0.34 in H2O 0.36 in H2O 0.24/0.12 in H2O 0.068 in/100ft 976 cfm 531 ft Cooling 0.70 in H2O 0.34 in H2O 0.36 in H2O 0.24/0.12 in H2O 0.068 in/100ft 976 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) Rect Size (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Roam It 2634 70 32 0.111 6 OxO ShMt 23.0 195.0 st2 Room1-A h 2634 70 32 0.113 6 OxO ShMt 35.0 180.0 st2 RwrrQ h 3248 87 39 0.068 6 OxO ShMt 33.0 325.0 stl Room3 C 347 22 29 0.089 6 OxO ShMt 13.0 260.0 stl Room4 C 857 60 72 0.080 6 OxO ShMt 23.0 280.0 stl Rooms It 1750 47 22 0.116 6 OxO ShMt 14.0 195.0 st2 Room7 C 923 46 78 0.114 6 Ox0 ShMt 38.0 175.0 st2 Room7-A C 923 46 78 0.114 6 OxO ShMt 27.0 185.0 st2 Room7-B C 923 46 78 0.144 6 OxO ShMt 33.0 135.0 st2 Rooms C 773 61 65 0.112 6 OxO ShMt 22.0 195.0 st2 RoomB-A c 773 61 65 0.114 6 OxO ShMt 23.0 190.0 st2 Room* C 1191 90 101 0.110 6 OxO ShMt 26.0 195.0 st2 Room10 C 1057 78 89 0.085 6 OxO ShMt 25.0 260.0 stl Room11 h 2393 64 58 0.108 6 OxO ShMt 30.0 195.0 stl Ream1-A h 2393 64 58 0.068 6 OxO ShMt 36.0 320.0 stl Room12 C 819 46 69 0.116 6 OxO ShMt 15.0 195.0 stl Rwm13 It 714 19 10 0.127 6 Ox 0 ShMt 6.0 185.0 1 stl Trunk Htg CIg Design Veloc Diam Rect Duct Duct Name Type (cfm) (cfm) FR (fpm) (in) Size (in) Material Trunk stl PeakAVF 439 425 0.068 565 11 8 x 14 ShtMetl st2 PeakAVF 537 551 0.110 709 11 8 x 14 ShtMetl Cc wnghtsoft RighRSulte Residential 6.0.79 RSR40835 200ESep-0408:35:12 /95q CAMy Docunems\Wri91itsoft WAC\BROS CONCRETE NICKAND MARCIE JENSEN.up Calc=MJ8 Orientation Page Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam RectSize Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matt Trunk rb1 Ox0 357 226 129.0 0.091 564 10 2-14x3.25 2-10x9 SJSp rt1 rb2 Ox0 110 136 173.0 0.068 430 7 14x3.25 1Ox5 SJSp rt2 rb3 Ox0 129 137 71.0 0.165 434 6 14x3.25 10x5 SJSp rb4 Ox0 90 101 132.0 0.089 319 6 14x3.25 1Ox5 SJSp rt1 rb5 Ox0 291 376 144.0 0.081 595 10 2-14x3.25 2-10x9 SJSp rt2 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam Rect Duct Duct Name Type (Cfm) (cfm) FIR (fpm) (in) Size (in) Material Trunk rt1 Peak AVF 447 327 0.089 804 10 8 x 10 ShtMetl rt2 Peak AVF 400 512 0.068 576 12 8 x 16 ShtMetl !-:- wnghtsoft Right-Sude ResWMlial6.0.79RSR40835 2006-Sep0408:35:12 q�,(,ACAMy DecmentstWnghtsoft HVAC1BROS CONCRETE NICK AND MARCIE JENSEN.ap Calc=MJB Orientabon Paget