Loading...
HomeMy WebLinkAboutREVIEW ACTIONS - 06-00474 - Dr Scott Hardy - Medical OfficeP. 1 T M mory TX Result Report ( Oct. 13. 2006 3:31PM 2) Date/Time: Oct,13, 2006 3:30PM File Page No. Mode Destination Pg(s) Result Not Sent ---------------------------------------------------------------------------------------------------- 2905 Memory TX 3592271 P. 3 OK ---------------------------------------------------------------------------------------------------- Reason for error E. 1) Hang up or 1 i ne fail E. 2) Busy E. 3) No answer E. 4) No fats imi 1 e connection E. 5) Exceeded max. E—mail size 12N. Catr3okV zm aate�trods� Fax �ct�9 P&=20L s9J= PoeZ08.3S9307T CITY OF REXBURG �" . Tee From Fmc � Z Pagan. Plioaa Dalaa �D Ra ee M M CITY OF REXBURG cb, Amcrica' Family Community October 13, 2006 RO Box 280 19 E Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Review Action Fax (208) 359-3022 Permit Number: 06 00474 Project Name: Dr. Scott Hardy Medical Office Project Type: Commercial New Review Item Actions Required for Approval Approved Pladnnings,S,faff ,Review , _. _,____� Development Standards Review West facade is over 40 feet in length and must incorporate a wall projection or recess a minimum of 3 foot depth and a minimum of 8 contiguous feet length. Development Standards Review Parking must be screened from the street. Please provide a landscape plan. Parcel, #'s RPROOOW2020020 o� gEX81j't P.O Box 280 C I T Y� O E 19 E Main St. REXBURG Rexburg, Idaho 83440 Phone 208 359-3020 ,'., . ,.• Ameritai Famil}� Community( � Review Action Fax (208) 359-3022 September 29, 2006 Permit Number: 06 00473 Project Name: Dr. Scott Hardy Medical Office Project Type: Site Plan Review Review Item Actions Required for Approval Approved BuiiCg�: patine -ice Number of Parking Spaces 11 parking spaces are required. 11 spaces are 09/28/2006 provided. Miscellaneous Grades and drainage are not shown. Please provide. Plumbing Review Setbacks and Propertly Lines Fire Separation Snow Storage Parking Configuration Parcel Vs; RPROOOW2020020 The 20' rear yard setback is not complete on the south end of the lot. Exterior walls that are closer than 10' to lot lines are required to be fire rated. Exterior walls that are closer than 10' to lot lines are required to be fire rated. Identify snow storage. Parking lot does not have 22' wide aisle as required by the Zoning Ordinance. Oct. 4. 2006 11: 24AM .�o�utq�o+► CITY OF " P BURG -...�. ca• -- Review Action October 4, 2006 Permit Number: 06 00474 Project Name: Dr. Scott Tardy Medical Office Project Type: Commercial New Review item Actions Required for ABpr t Electrical Circuits Review Electrical Service Review Intoner Environment Exiting Review Energy Conservation Compliance Review Building Code Fire Compliance Review Water and Sewer Service Mechanical Review Waste Water Application Structural Review Height and Area Review Building Type Compliance No.2842 P. 12 P.O Box 280 18 E Maln St Rexburg, Idaho 83"0 Phone (208) 3W3020 Fax (208) $559.3022 In patient care areas there must be an isolated 09126/2006 grounding system. Such as hospital grade type MC cable or isolated grounding in conduit, etc. See article section 617 in the NEC. Required to have two sources of grounding, 0912612006 Ex. -one concrete encased electrode and one ground rod,etc. Wall and ceiling finishes must meet the 09/28/2006 requirement of IBC Section 803. Meets code requirements, 09/28/2008 Figured the lighting allowance only, and it meets 09/29/2006 code.20031FCC. Provide details to show 1 hour fire separation for the storage room and the upper room served by the ship ladder. Meets code requirements. Shearwall plans do not match those of the structural documents from structural engineer. Make changes and have engineer stamp the drawings. Upper storage area is not identified in structural documents. Provide engineering design using commercial storage live loads. Provide truss structural documents. Meet code requirements. Building is Type VB. Complies with approved Site Plan Review Site plan has been reviewed. Madison County / City of Rexl- lrg GIS Page 1 of 1 a 5 mm z http://agentsmithlintranetlarcimslprintable.aspx?MapURL=http://agentsmithloutputlarcIM... 9/25/2006 °` p¢••u•° P.O Box 280 CITY OF %40/ %w/ 19 E Main St. REXBURG Rexburg, Idaho 83440 Phone (208) 359-3020 An¢nwi Fnrnllp Grmmuniry Review Action Fax (208) 359-3022 September 29, 2006 Permit Number: 06 00474 Project Name: Dr. Scott Hardy Medical Office Project Type: Commercial New Review Item •1 Building Department Review Electrical Circuits Review Electrical Service Review Interior Environment Exiting Review Building Code Fire Compliance Review Water and Sewer Service Height and Area Review Mechanical Review Waste Water Application Structural Review Energy Conservation Compliance Review Building Type Compliance Complies with approved Site Plan Review Accessibility Review In patient care areas there must be an isolated grounding system. Such as hospital grade type MC cable or isolated grounding in conduit, etc. See article section 517 in the NEC. Required to have two sources of grounding, Ex. -one concrete encased electrode and one ground rod,etc. Wall and ceiling finishes must meet the requirement of IBC Section 803. Meets code requirements. Provide details to show 1 hour fire seperation for the storage room and the upper room served by the ship ladder. Meet code requirements. Meets code requirements. Shearwall plans do not match those of the structural documents from structural engineer. Make changes and have engineer stamp the drawings. Upper storage area is not identified in structural documents. Provide engineering design using commercial storage live loads. Provide truss structural documents. Building is Type VB. Site plan has been reviewed. Provide grab bars at restroom. Restroom must be totally ADA compliant. 09/26/2006 09/26/2006 09/28/2006 09/28/2006 Oct. 13. 2006 3 ; 31 PM a4Q �t�.d CITY OP U R19Xi G •M{O • October 13, 2006 Review Action Permit Number: 06 00474 Protect Name: Dr. Scott Hardy Medical Office Protect Type: Commercial New No.2905 RL,�340 lt� 19 E Main St. Rexburg, Idaho 63440 Phone (208) 380-3020 Fax (208j 359-3022 Review Item Actlgoa Rqulred for Approved , „Approved INKINEEMMMIN Development Standards Review West facade is over 40 feet in length and must incorporate a wall projection or recess a minimum of 3 foot depth and a minimum of 8 contiguous feet length, Development Standards Review Parking must be screened from the street. Please provide a landscape plan. Parcel'#'s RPROOOW2020020 -Oct. 4. 2006 11: 24AM No. 2842 P. 9 Q W `%. RO Box 280 cirx 09 19EWin St. RM RG Rexburg.. kiaQh�o. 83}4�40 w (W �rw�w+r IhQna (208) 359-3020 f dmelid0� iYit!lfiy ri07iA�jj" '•�.• Review Action Fax (208) W9 SM October 4, 2006 Permit Number: 06 00473 Project Name: Dr. Scott Hardy Medical Office Project Type: Site Plan Review Review Item Actions Required for Appmy—al r t� w..7�Cs _ram Additional Comments IF YOU HAVE ANY QUESTIONS REGARDING 10/0112006 THIS REVIEW CONTACT CHRIS AT 705-1312. Fire Access Roads PROVIDED 10101/2006 Water Supply PLEASE PROVIDE HYDRANT FLOWS PRIOR 10/0112006 TO CONSTRUCTION Fire Large Signage NOT REQUIRED 10/01/2006 Parcel f's RPROOOW2020020 Oct. 4, 2006 11: 24AM No. 2842 P. 11 ox 280 9 EaMiaU at R.MVRG Rexburg, Idaho83440 Phone (208) 359.3020 •'•,+. +-•` ametia�tC�uttl�jCwRm,au�y Fax (2Q8} 359-3022 Review Action October 4, 2006 Permit Number: 06 00473 Project Name: Dr. Scott Hardy Medical Office Project Type: Site Plan Review Review item Actions Required for Approval - removed Approved Site Plan 1. The side yard setback has not been met on the corner of the building against the canal. 2. There will be no front footage oharges for the building. Parcel We RPROGOW2020020 Oct. 4. 2006 11: 24AM No. 2842 P. 10 P_O Box 280 J4o .oy� CITY OF 19EWin St RFMU G Rexburg, Idaho 83440 W*4 m , Pf Phan (208) UM020 ••,,=,.a � Review Action Fax (208) 35"022 October 4, 2006 Permit Number: 06 00473 Project Name: Dr. Scott Hardy Medical Office Project Type: Site Plan Review Review Item Approved Site Plan This parcel is zoned MDR1. A medical office is not allowed in this zone. To change the zone, the Comprehensive Plan map must also be changed. Parcel WS RPR000W2020020 C I T Y O F P.O BOX 260 _. 19 g, Main St. 8 � o �7-�vn ��-r�/-+ l�L'+1LL7 V 1\l7 Rexburg, Idaho 63440 Phone (208) 359-3020 nn:enw; wn,4-Con,on4mly Review Action Fax (208) 359-3022 October 23, 2006 —D A l d "%3 01P Permit Number: 06 00474 Project Name: Dr. Scott Hardy Medical Office Project Type: Commercial New Review Item Actions Required for Approval Approved Administrative Review Permit Tech Notes 1) Plumbing, Mechanical, & Electrical Contractor information needed including a copy of their license. 2) Plumbing, Mechanical & Electrical valuations needed. 3)1" water meter? Verify size needed. 4) Construction permit & subcontractor list needed (see page 7 & 8 of application). Parcel #'s RPROOOW2020020 _CITY OF REXBURG --- CW - Anienca' Famih, Community October 23, 2006 P.O Box 280 19 E Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Review Action Fax (208) 359-3022 Permit Number: 06 00474 Project Name: Dr. Scott Hardy Medical Office Project Type: Commercial New Review Item Actions Required for Approval AP roved tdnDe acme �IRe" �'►er.� _ Electrical Circuits Review In patient care areas there must be an isolated 09/26/2006 grounding system. Such as hospital grade type MC cable or isolated grounding in conduit, etc. See article section 517 in the NEC. Electrical Service Review Required to have two sources of grounding, 09/26/2006 Ex. -one concrete encased electrode and one ground rod,etc. Interior Environment Wall and ceiling finishes must meet the 09/28/2006 requirement of IBC Section 803. Exiting Review Meets code requirements. 09/28/2006 Energy Conservation Compliance Review Figured the lighting allowance only, and it meets 09/29/2006 code.20031ECC. Water and Sewer Service All plumbing services are required to be tested 10/09/2006 and inspected before covering. Plumbing Sewer Drain Review All drains are required to be tested and 10/09/2006 inspected before covering. Plumbing Storm Drain Review All storm drains are required to be installed 10/09/2006 according to the Uniform Plumbing Code. Plumbing Potable Water Review Water lines are required to have the proper 10/09/2006 backflow prevention installed before final plumbing inspection. Building Code Fire Compliance Review Provide details to show 1 hour fire seperation for the storage room and the upper room served by the ship ladder. Accessibility Review Provide grab bars at restroom. Restroom must be totally ADA compliant. Complies with approved Site Plan Review Site plan has been reviewed. Height and Area Review Meet code requirements. Waste Water Grease Trap Form Waste Water Application CITY OF REXBURG C'm --- - Americ4 Family Community October 23, 2006 P.O Box 280 1� 19 E Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Review Action Fax (208) 359-3022 Permit Number: 06 00474 Project Name: Dr. Scott Hardy Medical Office Project Type: Commercial New Review Item Structural Review Shearwall plans do not match those of the structural documents from structural engineer. Make changes and have engineer stamp the drawings. Upper storage area is not identified in structural documents. Provide engineering design using commercial storage live loads. Provide truss structural documents. Mechanical Review Meets code requirements. Building Type Compliance Parcel Ws RPROOOW2020020 Building is Type VB. a 6�4 RO Box 280 ��CVI THY TOmF "WV 19 E Main St. ° R� V RG Rexburg, Idaho 83440 `w Phone (208) 359-3020 Anserka' Family Community Review Action Fax (208) 359-3022 October 23, 2006 Permit Number: 06 00474 Project Name: Dr. Scott Hardy Medical Office Project Type: Commercial New Review Item Actions Required for Approval Ap roved Fr Required Fire Flow See site plan review 10/09/2006 Alarm Systems None shown on plans 10/09/2006 Commercial Cooking N/A 10/09/2006 Water Supply See site plan review 10/09/2006 Fire Access Roads See site plan review 10/09/2006 Fire Extinguishers Fire extinguishers are required for this 10/09/2006 occupancy. Extinguishers must be installed before final fire inspection. Standpipes N/A 10/09/2006 Automatic Fire Extinguishing Systems None shown on plans 10/09/2006 Parcel ft RPROOOW2020020 _yvC1ry of REXBURG Ow Americas Family Community October 23, 2006 P.O Box 280 \� 19 E Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Review Action Fax (208) 359-3022 Permit Number: 06 00474 Project Name: Dr. Scott Hardy Medical Office Project Type: Commercial New Review Item Actions Required for Approval Apuroved Development Standards Review West facade is over 40 feet in length and must incorporate a wall projection or recess a minimum of 3 foot depth and a minimum of 8 contiguous feet length. Development Standards Review Parking must be screened from the street. Please provide a landscape plan. Parcel Vs RPROOOW2020020 C 1 T Y O F REXBURG CLW -- Anurita' Famih' Community _ P.O Box 280 19 E Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Review Action Fax (208) 359-3022 October 4, 2006 I Permit Number: 06 00474 Project Name: Dr. Scott Hardy Medical Office Project Type: Commercial New Review Item Actions Required for Approval Aao,_, roved Electrical Circuits Review In patient care areas there must be an isolated 09/26/2006 grounding system. Such as hospital grade type MC cable or isolated grounding in conduit, etc. See article section 517 in the NEC. Electrical Service Review Required to have two sources of grounding, 09/26/2006 Ex. -one concrete encased electrode and one ground rod,etc. Interior Environment Wall and ceiling finishes must meet the 09/28/2006 requirement of IBC Section 803. Exiting Review Meets code requirements. 09/28/2006 Energy Conservation Compliance Review Figured the lighting allowance only, and it meets 09/29/2006 code.20031ECC. Building Code Fire Compliance Review Provide details to show 1 hour fire seperation for the storage room and the upper room served by the ship ladder. Water and Sewer Service Mechanical Review Meets code requirements. Waste Water Application Structural Review Shearwall plans do not match those of the structural documents from structural engineer. Make changes and have engineer stamp the drawings. Upper storage area is not identified in structural documents. Provide engineering design using commercial storage live loads. Provide truss structural documents. Height and Area Review Meet code requirements. Building Type Compliance Building is Type VB. Complies with approved Site Plan Review Site plan has been reviewed. aex8tr C _ P.O Box 280 vio ,• CITY o F 19 E Main St. � °RE1BV RG Rexburg, Idaho 83440 O' Phone (208) 359-3020 Anterrca's Family Cvmmunify Review Action Fax (208) 359-3022 October 4, 2006 Permit Number: 06 00474 Project Name: Dr. Scott Hardy Medical Office Project Type: Commercial New Review Item Actions Required for Approval Ap rp oved Accessibility Review Provide grab bars at restroom. Restroom must be totally ADA compliant. Plumbing Sewer Drain Review Plumbing Storm Drain Review Plumbing Potable Water Review Waste Water Grease Trap Form Parcel Vs RPROOOW2020020