October 13, 2006
RO Box 280
19 E Main St.
Rexburg, Idaho 83440
Phone (208) 359-3020
Review Action Fax (208) 359-3022
Permit Number: 06 00474
Project Name: Dr. Scott Hardy Medical Office
Project Type: Commercial New
Review Item Actions Required for Approval Approved
Pladnnings,S,faff ,Review , _. _,____�
Development Standards Review West facade is over 40 feet in length and must
incorporate a wall projection or recess a
minimum of 3 foot depth and a minimum of 8
contiguous feet length.
Development Standards Review Parking must be screened from the street.
Please provide a landscape plan.
Parcel, #'s RPROOOW2020020
o� gEX81j't P.O Box 280
C I T Y� O E
19 E Main St.
REXBURG Rexburg, Idaho 83440
Phone 208 359-3020
,'., . ,.• Ameritai Famil}� Community(
� Review Action Fax (208) 359-3022
September 29, 2006
Permit Number: 06 00473
Project Name: Dr. Scott Hardy Medical Office
Project Type: Site Plan Review
Review Item Actions Required for Approval Approved
BuiiCg�: patine -ice
Number of Parking Spaces 11 parking spaces are required. 11 spaces are 09/28/2006
provided.
Miscellaneous Grades and drainage are not shown. Please
provide.
Plumbing Review
Setbacks and Propertly Lines
Fire Separation
Snow Storage
Parking Configuration
Parcel Vs; RPROOOW2020020
The 20' rear yard setback is not complete on
the south end of the lot. Exterior walls that are
closer than 10' to lot lines are required to be fire
rated.
Exterior walls that are closer than 10' to lot lines
are required to be fire rated.
Identify snow storage.
Parking lot does not have 22' wide aisle as
required by the Zoning Ordinance.
Oct. 4. 2006 11: 24AM
.�o�utq�o+► CITY OF
" P BURG
-...�. ca• --
Review Action
October 4, 2006
Permit Number: 06 00474
Project Name: Dr. Scott Tardy Medical Office
Project Type: Commercial New
Review item Actions Required for ABpr t
Electrical Circuits Review
Electrical Service Review
Intoner Environment
Exiting Review
Energy Conservation Compliance Review
Building Code Fire Compliance Review
Water and Sewer Service
Mechanical Review
Waste Water Application
Structural Review
Height and Area Review
Building Type Compliance
No.2842 P. 12
P.O Box 280
18 E Maln St
Rexburg, Idaho 83"0
Phone (208) 3W3020
Fax (208) $559.3022
In patient care areas there must be an isolated
09126/2006
grounding system. Such as hospital grade type
MC cable or isolated grounding in conduit, etc.
See article section 617 in the NEC.
Required to have two sources of grounding,
0912612006
Ex. -one concrete encased electrode and one
ground rod,etc.
Wall and ceiling finishes must meet the
09/28/2006
requirement of IBC Section 803.
Meets code requirements,
09/28/2008
Figured the lighting allowance only, and it meets
09/29/2006
code.20031FCC.
Provide details to show 1 hour fire separation
for the storage room and the upper room
served by the ship ladder.
Meets code requirements.
Shearwall plans do not match those of the
structural documents from structural engineer.
Make changes and have engineer stamp the
drawings. Upper storage area is not identified
in structural documents. Provide engineering
design using commercial storage live loads.
Provide truss structural documents.
Meet code requirements.
Building is Type VB.
Complies with approved Site Plan Review Site plan has been reviewed.
Madison County / City of Rexl- lrg GIS
Page 1 of 1
a
5
mm
z
http://agentsmithlintranetlarcimslprintable.aspx?MapURL=http://agentsmithloutputlarcIM... 9/25/2006
°` p¢••u•° P.O Box 280
CITY OF
%40/ %w/ 19 E Main St.
REXBURG Rexburg, Idaho 83440
Phone (208) 359-3020
An¢nwi Fnrnllp Grmmuniry
Review Action Fax (208) 359-3022
September 29, 2006
Permit Number: 06 00474
Project Name: Dr. Scott Hardy Medical Office
Project Type: Commercial New
Review Item •1
Building Department Review
Electrical Circuits Review
Electrical Service Review
Interior Environment
Exiting Review
Building Code Fire Compliance Review
Water and Sewer Service
Height and Area Review
Mechanical Review
Waste Water Application
Structural Review
Energy Conservation Compliance Review
Building Type Compliance
Complies with approved Site Plan Review
Accessibility Review
In patient care areas there must be an isolated
grounding system. Such as hospital grade type
MC cable or isolated grounding in conduit, etc.
See article section 517 in the NEC.
Required to have two sources of grounding,
Ex. -one concrete encased electrode and one
ground rod,etc.
Wall and ceiling finishes must meet the
requirement of IBC Section 803.
Meets code requirements.
Provide details to show 1 hour fire seperation
for the storage room and the upper room
served by the ship ladder.
Meet code requirements.
Meets code requirements.
Shearwall plans do not match those of the
structural documents from structural engineer.
Make changes and have engineer stamp the
drawings. Upper storage area is not identified
in structural documents. Provide engineering
design using commercial storage live loads.
Provide truss structural documents.
Building is Type VB.
Site plan has been reviewed.
Provide grab bars at restroom. Restroom must
be totally ADA compliant.
09/26/2006
09/26/2006
09/28/2006
09/28/2006
Oct. 13. 2006 3 ; 31 PM
a4Q �t�.d CITY OP
U R19Xi G
•M{O •
October 13, 2006
Review Action
Permit Number: 06 00474
Protect Name: Dr. Scott Hardy Medical Office
Protect Type: Commercial New
No.2905 RL,�340
lt� 19 E Main St.
Rexburg, Idaho 63440
Phone (208) 380-3020
Fax (208j 359-3022
Review Item Actlgoa Rqulred for Approved , „Approved
INKINEEMMMIN
Development Standards Review West facade is over 40 feet in length and must
incorporate a wall projection or recess a
minimum of 3 foot depth and a minimum of 8
contiguous feet length,
Development Standards Review Parking must be screened from the street.
Please provide a landscape plan.
Parcel'#'s RPROOOW2020020
-Oct. 4. 2006 11: 24AM No. 2842 P. 9
Q W `%. RO Box 280
cirx 09 19EWin St.
RM RG Rexburg.. kiaQh�o. 83}4�40
w (W �rw�w+r IhQna (208) 359-3020
f dmelid0� iYit!lfiy ri07iA�jj"
'•�.• Review Action Fax (208) W9 SM
October 4, 2006
Permit Number: 06 00473
Project Name: Dr. Scott Hardy Medical Office
Project Type: Site Plan Review
Review Item Actions Required for Appmy—al r t�
w..7�Cs _ram
Additional Comments IF YOU HAVE ANY QUESTIONS REGARDING 10/0112006
THIS REVIEW CONTACT CHRIS AT 705-1312.
Fire Access Roads PROVIDED 10101/2006
Water Supply PLEASE PROVIDE HYDRANT FLOWS PRIOR 10/0112006
TO CONSTRUCTION
Fire Large Signage NOT REQUIRED 10/01/2006
Parcel f's RPROOOW2020020
Oct. 4, 2006 11: 24AM No. 2842 P. 11
ox 280
9 EaMiaU at
R.MVRG Rexburg, Idaho83440
Phone (208) 359.3020
•'•,+. +-•` ametia�tC�uttl�jCwRm,au�y Fax (2Q8} 359-3022
Review Action
October 4, 2006
Permit Number: 06 00473
Project Name: Dr. Scott Hardy Medical Office
Project Type: Site Plan Review
Review item Actions Required for Approval - removed
Approved Site Plan 1. The side yard setback has not been met on
the corner of the building against the canal.
2. There will be no front footage oharges for the
building.
Parcel We RPROGOW2020020
Oct. 4. 2006 11: 24AM No. 2842 P. 10
P_O Box 280
J4o .oy� CITY OF 19EWin St
RFMU G Rexburg, Idaho 83440
W*4 m , Pf Phan (208) UM020
••,,=,.a �
Review Action Fax (208) 35"022
October 4, 2006
Permit Number: 06 00473
Project Name: Dr. Scott Hardy Medical Office
Project Type: Site Plan Review
Review Item
Approved Site Plan This parcel is zoned MDR1. A medical office is
not allowed in this zone. To change the zone,
the Comprehensive Plan map must also be
changed.
Parcel WS RPR000W2020020
C I T Y O F P.O BOX 260
_. 19 g, Main St.
8
� o �7-�vn ��-r�/-+
l�L'+1LL7 V 1\l7 Rexburg, Idaho 63440
Phone (208) 359-3020
nn:enw; wn,4-Con,on4mly
Review Action Fax (208) 359-3022
October 23, 2006
—D A l d "%3 01P
Permit Number: 06 00474
Project Name: Dr. Scott Hardy Medical Office
Project Type: Commercial New
Review Item Actions Required for Approval Approved
Administrative Review
Permit Tech Notes 1) Plumbing, Mechanical, & Electrical
Contractor information needed including a copy
of their license.
2) Plumbing, Mechanical & Electrical valuations
needed.
3)1" water meter? Verify size needed.
4) Construction permit & subcontractor list
needed (see page 7 & 8 of application).
Parcel #'s RPROOOW2020020
_CITY OF
REXBURG
--- CW -
Anienca' Famih, Community
October 23, 2006
P.O Box 280
19 E Main St.
Rexburg, Idaho 83440
Phone (208) 359-3020
Review Action Fax (208) 359-3022
Permit Number: 06 00474
Project Name: Dr. Scott Hardy Medical Office
Project Type: Commercial New
Review Item
Actions Required for Approval
AP roved
tdnDe acme �IRe" �'►er.� _
Electrical Circuits Review
In patient care areas there must be an isolated
09/26/2006
grounding system. Such as hospital grade type
MC cable or isolated grounding in conduit, etc.
See article section 517 in the NEC.
Electrical Service Review
Required to have two sources of grounding,
09/26/2006
Ex. -one concrete encased electrode and one
ground rod,etc.
Interior Environment
Wall and ceiling finishes must meet the
09/28/2006
requirement of IBC Section 803.
Exiting Review
Meets code requirements.
09/28/2006
Energy Conservation Compliance Review
Figured the lighting allowance only, and it meets
09/29/2006
code.20031ECC.
Water and Sewer Service
All plumbing services are required to be tested
10/09/2006
and inspected before covering.
Plumbing Sewer Drain Review
All drains are required to be tested and
10/09/2006
inspected before covering.
Plumbing Storm Drain Review
All storm drains are required to be installed
10/09/2006
according to the Uniform Plumbing Code.
Plumbing Potable Water Review
Water lines are required to have the proper
10/09/2006
backflow prevention installed before final
plumbing inspection.
Building Code Fire Compliance Review
Provide details to show 1 hour fire seperation
for the storage room and the upper room
served by the ship ladder.
Accessibility Review
Provide grab bars at restroom. Restroom must
be totally ADA compliant.
Complies with approved Site Plan Review
Site plan has been reviewed.
Height and Area Review
Meet code requirements.
Waste Water Grease Trap Form
Waste Water Application
CITY OF
REXBURG
C'm --- -
Americ4 Family Community
October 23, 2006
P.O Box 280
1� 19 E Main St.
Rexburg, Idaho 83440
Phone (208) 359-3020
Review Action Fax (208) 359-3022
Permit Number: 06 00474
Project Name: Dr. Scott Hardy Medical Office
Project Type: Commercial New
Review Item
Structural Review Shearwall plans do not match those of the
structural documents from structural engineer.
Make changes and have engineer stamp the
drawings. Upper storage area is not identified
in structural documents. Provide engineering
design using commercial storage live loads.
Provide truss structural documents.
Mechanical Review Meets code requirements.
Building Type Compliance
Parcel Ws RPROOOW2020020
Building is Type VB.
a 6�4 RO Box 280
��CVI THY TOmF "WV 19 E Main St.
° R� V RG Rexburg, Idaho 83440
`w Phone (208) 359-3020
Anserka' Family Community
Review Action Fax (208) 359-3022
October 23, 2006
Permit Number: 06 00474
Project Name: Dr. Scott Hardy Medical Office
Project Type: Commercial New
Review Item
Actions Required for Approval
Ap roved
Fr
Required Fire Flow
See site plan review
10/09/2006
Alarm Systems
None shown on plans
10/09/2006
Commercial Cooking
N/A
10/09/2006
Water Supply
See site plan review
10/09/2006
Fire Access Roads
See site plan review
10/09/2006
Fire Extinguishers
Fire extinguishers are required for this
10/09/2006
occupancy. Extinguishers must be installed
before final fire inspection.
Standpipes N/A 10/09/2006
Automatic Fire Extinguishing Systems None shown on plans 10/09/2006
Parcel ft RPROOOW2020020
_yvC1ry of
REXBURG
Ow
Americas Family Community
October 23, 2006
P.O Box 280
\� 19 E Main St.
Rexburg, Idaho 83440
Phone (208) 359-3020
Review Action Fax (208) 359-3022
Permit Number: 06 00474
Project Name: Dr. Scott Hardy Medical Office
Project Type: Commercial New
Review Item Actions Required for Approval Apuroved
Development Standards Review West facade is over 40 feet in length and must
incorporate a wall projection or recess a
minimum of 3 foot depth and a minimum of 8
contiguous feet length.
Development Standards Review Parking must be screened from the street.
Please provide a landscape plan.
Parcel Vs RPROOOW2020020
C 1 T Y O F
REXBURG
CLW --
Anurita' Famih' Community
_ P.O Box 280
19 E Main St.
Rexburg, Idaho 83440
Phone (208) 359-3020
Review Action Fax (208) 359-3022
October 4, 2006 I
Permit Number: 06 00474
Project Name: Dr. Scott Hardy Medical Office
Project Type: Commercial New
Review Item
Actions Required for Approval
Aao,_, roved
Electrical Circuits Review
In patient care areas there must be an isolated
09/26/2006
grounding system. Such as hospital grade type
MC cable or isolated grounding in conduit, etc.
See article section 517 in the NEC.
Electrical Service Review
Required to have two sources of grounding,
09/26/2006
Ex. -one concrete encased electrode and one
ground rod,etc.
Interior Environment
Wall and ceiling finishes must meet the
09/28/2006
requirement of IBC Section 803.
Exiting Review
Meets code requirements.
09/28/2006
Energy Conservation Compliance Review
Figured the lighting allowance only, and it meets
09/29/2006
code.20031ECC.
Building Code Fire Compliance Review Provide details to show 1 hour fire seperation
for the storage room and the upper room
served by the ship ladder.
Water and Sewer Service
Mechanical Review Meets code requirements.
Waste Water Application
Structural Review Shearwall plans do not match those of the
structural documents from structural engineer.
Make changes and have engineer stamp the
drawings. Upper storage area is not identified
in structural documents. Provide engineering
design using commercial storage live loads.
Provide truss structural documents.
Height and Area Review Meet code requirements.
Building Type Compliance Building is Type VB.
Complies with approved Site Plan Review Site plan has been reviewed.
aex8tr C _ P.O Box 280
vio ,• CITY o F 19 E Main St.
� °RE1BV RG Rexburg, Idaho 83440
O' Phone (208) 359-3020
Anterrca's Family Cvmmunify
Review Action Fax (208) 359-3022
October 4, 2006
Permit Number: 06 00474
Project Name: Dr. Scott Hardy Medical Office
Project Type: Commercial New
Review Item Actions Required for Approval Ap rp oved
Accessibility Review Provide grab bars at restroom. Restroom must
be totally ADA compliant.
Plumbing Sewer Drain Review
Plumbing Storm Drain Review
Plumbing Potable Water Review
Waste Water Grease Trap Form
Parcel Vs RPROOOW2020020