Loading...
HomeMy WebLinkAboutCOMCHECK 2 - 06-00474 - Dr Scott Hardy - Medical OfficeCOMcheck Software Version 3.3.0 Lighting Application Worksheet 2003 IECC Report Date: Data filename: C:1Documents and Seftingstbrets\My Documentskir.hardy's office.cck Section 1: Allowed Lighting Power Calculation A B C D Floor Area Allowed Allowed Watts Medical and Clinical Care Section 2: Actual Lighting Power Calculation 2525 1.2 3030 Total Allowed Watts = 3030 A B C D E Fixture ID : Description I Lamp I Wattage Per Lamp I Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Waft. Linear Fluorescent 1: F1: 48" T8 32W / Electronic 3 22 96 2112 Linear Fluorescent 2: F2: 48' T8 32W / Electronic 2 4 64 256 Linear Fluorescent 3: F3: 48" T8 32W I Electronic 2 2 64 128 Compact Fluorescent 1: F6: Twin Tube 24/26/27W / Electronic 1 6 26 156 Linear Fluorescent 4: F7: 48" T8 32W / Electronic 2 3 64 192 Linear Fluorescent 5: F8: 48" T8 32W / Electronic 2 3 64 192 Incandescent l: Incandescent 50W 1 2 50 100 Total Actual Watts = 3136 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 3030 Total Actual Watts = 3136 Project Compliance = -106 Lighting FAILS Design 3% worse than Sys o� s Ct S Page 3 of 3 COMcheck Software Version 3.3.0 Lighting Compliance Certificate 2003 IECC Report Date: 10/17/06 Data filename: C:\Documents and Settings\brets\My Documents\dr.hardy's of8ce.cck Section 1: Project Information Project Title: Dr. Hardy's office Construction Site: Owner/Agent: 377 Walker Dr. Rexburg, ID 83440 Permit No. 06-00474 Permit Date: 09/25/06 Section 2: General Information Building Use Description by: Project Type: New Construction Bulldina Type Floor Area Medical and Clinical Care 2525 Section 3: Requirements Checklist Interior Lighting: 1. Total actual watts must be less than or equal to total allowed watts. Allowed Watts Actual Watts Complies 3030 3136 NO 2. Fait signs 5 Watts or less per side. Designer/Contractor. Exterior Lighting: ❑ 3. Efficacy greater than 45 lumens/W. Exceptions: Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low -voltage landscape lighting. Controls, Switching, and Wiring: ❑ 4. Independent controls for each space (switch/occupancy sensor). Exceptions: Areas designated as security or emergency areas that must be continuously illuminated. Lighting in stairways or corridors that are elements of the means of egress. 5. Master switch at entry to hotelfmotel guest room. 6. Individual dwelling units separately metered. 7. Each space provided with a manual control to provide uniform light reduction by at least 50%. Exceptions: Only one lummaire in space; An occupant -sensing device controls the area; The area is a corridor, storeroom, restroom, public lobby or guest room; Areas that use less than 0.6 Wattslsq.ft. O 8. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Page 1 of 3 9. PhotoceiVastronomical time h on exterior lights. Exceptions. Lighting intended for 24 hour use. El 10. Tandem wired one -lamp and there -lamp ballasted luminaires (No single -lamp ballasts). Exceptions. Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair. Page 2 of 3