Loading...
HomeMy WebLinkAboutREVIEW ACTIONS & REVIEW RESPONSE - 06-00473 - Dr Scott Hardy - Medical Office - Site PlanaeX8 c.l T Y o F cam, - Antericd Family Community REXBURG RO Box 280 lxw� 1%W1 19 E Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Review Action Fax (208) 359-3022 October 4, 2006 � I 0/4 Permit Number: 06 00473 Project Name: Dr. Scott Hardy Medical Office Project Type: Site Plan Review Review Item Actions Required for Approval Approved Number of Parking Spaces 11 parking spaces are required. 11 spaces are 09/28/2006 provided. Miscellaneous Grades and drainage are not shown. Please provide. Plumbing Review Setbacks and Propertly Lines Fire Separation Snow Storage Parking Configuration Parcel #'s RPROOOW2020020 The 20' rear yard setback is not complete on the south end of the lot. Exterior walls that are closer than 10' to lot lines are required to be fire rated. Exterior walls that are closer than 10' to lot lines are required to be fire rated. Identify snow storage. Parking lot does not have 22' wide aisle as required by the Zoning Ordinance. P.O Box 280 `moo i� C• I T Y O F 19 E Main St. o � REXBURG Rexburg, Idaho 83440 qa, .'., Amcric6 F=iq-Community Phone (208) 359-3020 =..o Review Action Fax (208) 359-3022 October 4, 2006 Permit Number: 06 00473 Project Name: Dr. Scott Hardy Medical Office Project Type: Site Plan Review Review Item Actions Required for Approval Ap rimed Additional Comments IF YOU HAVE ANY QUESTIONS REGARDING 10/01/2006 THIS REVIEW CONTACT CHRIS AT 705-1312. Fire Access Roads PROVIDED 10/01/2006 Water Supply PLEASE PROVIDE HYDRANT FLOWS PRIOR 10/01/2006 TO CONSTRUCTION Fire Lane Signage NOT REQUIRED 10/01/2006 Parcel #'s RPROOOW2020020 C I T Y O F REXBURG -- cw America's Family Community October 4, 2006 P.O Box 280 19 E Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Review Action Fax (208) 359-3022 Permit Number: 06 00473 Project Name: Dr. Scott Hardy Medical Office Project Type: Site Plan Review Review Item Actions Required for Approval Ap roved Approved Site Plan This parcel is zoned MDR1. A medical office is not allowed in this zone. To change the zone, the Comprehensive Plan map must also be changed. Parcel Ws RPROOOW2020020 'a �aexeU4C�y C', 1 T Y o F _ P.O Box 280 �! 19 E Main St. REXBURG Rexburg, Idaho 83440 c%W ---- '., Americas Fmnin- Communily Phone (208) 359-3020 � Review Action Fax (208) 359-3022 October 4, 2006 Permit Number: 06 00473 Project Name: Dr. Scott Hardy Medical Office Project Type: Site Plan Review Review Item Actions Required for Approval Aanr�ove_d Approved Site Plan 1. The side yard setback has not been met on the comer of the building against the canal. 2. There will be no front footage charges for the building. Parcel Ws RPROOOW2020020 aexeu 10. _CITY OF ° REXBURG OW Americo fiend • Community RO sox 280 lqw� 19 E Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Review Action Fax (208) 359-3022 October 23, 2006 [4 X t� 117I23 /ap �j Permit Number: 06 00473 Project Name: Dr. Scott Hardy Medical Office Project Type: Site Plan Review Review Item Actions Required for Approval AAoroved _mend R J ew Number of Parking Spaces 11 parking spaces are required. 11 spaces are 09/28/2006 provided. Miscellaneous Grades and drainage are not shown. Please provide. Plumbing Review Setbacks and Propertly Lines Fire Separation Snow Storage Parking Configuration Parcel Ws RPROOOW2020020 The 20' rear yard setback is not complete on the south end of the lot. Exterior walls that are closer than 10' to lot lines are required to be fire rated. Exterior walls that are closer than 10' to lot lines are required to be fire rated. Identify snow storage. Parking lot does not have 22' wide aisle as required by the Zoning Ordinance. �pFacat'v P.O Box 280 CITY OF 1�l 19 E Main St. REXBURG Rexburg, Idaho 83440 `U — Phone (208) 359-3020 '., America's family Cummunify Review Action Fax (208) 359-3022 October 23, 2006 Permit Number: 06 00473 Project Name: Dr. Scott Hardy Medical Office Project Type: Site Plan Review Review Item Additional Comments IF YOU HAVE ANY QUESTIONS REGARDING 10/01/2006 THIS REVIEW CONTACT CHRIS AT 705-1312. Fire Access Roads PROVIDED 10/01/2006 Water Supply PLEASE PROVIDE HYDRANT FLOWS PRIOR 10/01/2006 TO CONSTRUCTION Fire Lane Signage NOT REQUIRED 10/01/2006 Parcel #'s RPROOOW2020020 RO Box 280 CITY o F1�l 19 E Main St. Olt REXBURG Rexburg, Idaho 83440 Ow -- Phone (208) 359-3020 Anierita' Family Community Review Action Fax (208) 359-3022 October 23, 2006 Permit Number: 06 00473 Project Name: Dr. Scott Hardy Medical Office Project Type: Site Plan Review Review Item Actions Required for Approval Approved F a�n i Si f Revie i Approved Site Plan This parcel is zoned MDR1. A medical office is 10/13/2006 Approved Site Plan Approved Site Plan Approved Site Plan Parcel ft RPROOOW2020020 not allowed in this zone. To change the zone, the Comprehensive Plan map must also be changed. - P&Z Commission has indicated this parcel will most likely be zoned commercial in the near future. Parking must be screened from the street. Please submit a landscaping plan. Parking isle must be at least 22 feet wide at all points. 12 parking stalls are required - 10 are shown. �aB�e, P.O Box 280 >� o +iy CITY O F �� 19 E Main St. ° REXBURG Rexburg, Idaho 83440 ro' Phone (208) 359-3020 America's Family Community Review Action Fax (208) 359-3022 October 23, 2006 Permit Number: 06 00473 Project Name: Dr. Scott Hardy Medical Office Project Type: Site Plan Review Review Item Actions Required for Approval Approved Approved Site Plan 1. The side yard setback has not been met on 10/13/2006 the corner of the building against the canal. 2. There will be no front footage charges for the building. 3. The building is not in the correct zone for this commercial structure. Parcel Vs RPROOOW2020020 Dr. Hardy Medical Office Review Response to City of Rexburg Fire Department: * The design of the system will be provided by Winston Dyer. Planning Staff. * Property shall be zoned LBD (I think). * The west fagade is 37'-0" in length. . * Landscaping will be provided to screen parking. Public Works: * The building is located a minimum of 20' from the waters edge as per canal agreement. Building Department: * See attached electrical response for first (2) items. * Wall and .ceiling finishes shall meet or exceed IBC section 503. * The upper room served by the .ship. ladder rs-a. mechanical room not a storage room. The BTU's of mechanical units is less than that required for a rated room. See mechanical drawings. * See attached."revised" structural calculations. * Grab bars shall be provided in restroom. 0600473 Dr. Scott Hardy Medical Office Site Plan Revisions 10/24/06 C'E I V E OCT 2 4 M06 CITY 0F REXBURG Oct. 4. 2006 11: 24AM CITY OP ° REXB V RG Am!/id AfilttJCAmeruoulp October 4, 2006 Review Action No.2842 P. Now� po Box 280 19 E Mahn St. Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-= Permit Number: 06 00473 Project Name: Dr. Scott Hardy Medical Office Project Type: Site plan Review Review item Actions Required for Appaml Approved -10 Approved Site Plan 1. The side yard setback has not been met on the Corner of the building against the canal. 2. There will be no front footage Charges for the building. Parcel fPs RPROOOW2020020