HomeMy WebLinkAboutRESCHECK - 06-00460 - 582 Autumn Dr - New SFRS
eck Compliance Certificate
ECCk So&ware Version 3.6 Release 2
Data filename: C:\Progmm Files\Check\REScheck\Belliston.rck
PROJECT TITLE: Belliston
CITY: Rexburg
STATE: Idaho
HDD: 8693
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.15
DATE: 09/17/06
DATE OF PLANS: 9-10-06
PROJECT DESCRIPTION:
Check Bounus Room
COMPLIANCE: Passes
Maximum UA = 423
Your Home UA = 393
7.1% Better Than Code (UA)
Ceiling l: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Vinyl Frame:Double Pane with Low-E
Door 1: Solid
Basement Wall 1: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 8.0'
Insulation depth: 9.0'
6 'Floor 1: All -Wood Joist/Truss: Over Unconditioned Space
Furnace 1: Forced Hot Air, 95 AFUE
Furnace 2: Forced Hot Air, 78 AFUE
Air Conditioner 1: Electric Central Air, 10 SEER
0600460
:W) Autumn Ct Jensen Constr.
Checked By/Date
R E C E P Y E
D
SEP 1 8 2006
CITY OF REXBURC
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor L�A
2055
0.0 48.0 41
1989
21.0 0.0 93
298
0.340 101
54
0.340 18
1989
12.0 0.0 117
870 38.0 0.0 23
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2000 IECC requirements in REScheck Version 3.6 Release 2 (lbrmerly MECcheck) and to comply with the
mandatory requirements listed in the REScheck Inspection Checklist.
En
lfta�
REScheck Inspection Checklist
2000 IECC
REScheck So$ware Version 3.6 Release 2
DATE: 09/17/06
PROJECT TITLE: Belliston
Bldg. I
Dept.
Use I
Ceilings:
[ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R48.0 continuous insulation
Comments:
I Above -Grade Walls:
[ ] I 1. Wall 1: Wood Frame, 16" o.c., R-21.0 cavity insulation
Comments:
Basement Walls:
[ ] I 1. Basement Wall 1: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul,
I R-12.0 cavity insulation
I Comments:
I
Windows:
[ ] I 1. Window 1: Vinyl Frame:Double Pane with Low-E, U-factor. 0.340
I For windows without labeled U factors, describe £atures:
I # Panes Frame Type Thermal Break? [ ] Yes [ ] No
I Comments:
I
I Doors:
[ ] I 1. Door l: Solid, U-factor. 0.340
I Comments:
I
I Floors:
[ ] ( 1. Floor 1: All -Wood Joist/Truss:Over Unconditioned Space, R-38.0 cavity insulation
Comments:
Heating and Cooling Equipment:
1. Furnace 1: Forced Hot Air, 95 AFUE or higher
Make and Model Number
[ ] I 2. Furnace 2: Forced Hot Air, 78 AFUE or higher
Make and Model Number
[ ] I 3. Air Conditioner 1: Electric Central Air, 10 SEER or higher
I Make and Model Number
I Air Leakage:
[ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
rn
with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a
3" clearance from insulation.
Vapor Retarder:
[ ] Required on the warn -in -winter side ofall non -vented framed ceilings, walls, and floors.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manuficturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manuficturer manuals far all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R values, glazing U-fictors, and heating equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
masticplus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ J Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut offithe heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
] ( Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of circulating system.
] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
ofthe heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ J HVAC piping conveying fluids above 105 °F or chilled fluids below 55 T must be insulated to the
I levels in Table 2.
Table]: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non -Circulating Runouts Circulating Mains and Runouts
Temp (,) Uo� to I" j1p t,^ 1.25" 1,510 to 2,081 Over 2"
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation
Thickness in Inches
by Pipe
Sizes
"
_Ping System Typed
Heating Systems
Rangr, ( )
2" Runouts
1" and Less
1.25" to
2"
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (1br feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5