HomeMy WebLinkAboutRESCHECK - 06-00459 - 561 Twisted Willow - New SFR0600459 561 Twisted Willow Way-TDG REScheck Software Version 3.7.3 Compliance Certificate Project Title: The Development Group Block 2 Lot 12 Willowbrook Report Date: 09/11/06 Data filename: C:\Documents and Settings\Scott\Desktop\TDG\Willow Brook Lot 12 rescheck.rck Energy Code: 2003 IECC Location: Rexburg, Idaho Construction Type: Single Family Glazing Area Percentage: 14% Heating Degree Days: 8693 Construction Site: 1007 Artic Willow Dr. Rexburg, ID 83440 Owner/Agent: Scott Jacobson The Development Group PO Box 832 Rexburg, ID 83440 208-390-0230 soott@builtbytdg.com Designer/Contractor: The Development Group Compliance: Passes Maximum UA: 428 Your Home UA: 336 -> 21.5% Better Than Code (UA) Ceiling 1: Cathedral Ceiling (no attic): 1703 40.0 0.0 44 Wall 1: Wood Frame, 16" o.c.: 333 23.0 0.0 18 Window 1: Vinyl Fmme:Double Pane with Low-E: 6 0.350 2 Wall 2: Wood Frame, 16" o.c.: 306 23.0 0.0 14 Window 2: Vinyl Frame:Double Pane with Low-E: 20 0.350 7 Window 3: Vinyl Fmme:Double Pane with Low-E: 40 0.350 14 Wall 3: Wood Frame, 16" o.c.: 81 23.0 0.0 3 Door 1: Glass: 21 0.350 7 Wall 4: Wood Frame, 16" o.c.: 171 23.0 0.0 8 Window 4: Vinyl Frame:Double Pane with Low-E: 12 0.350 4 Window 5: Vinyl Frame:Double Pane with Low-E: 12 0.350 4 Wall 5: Wood Frame, 16" o.c.: 180 23.0 0.0 9 Window 6: Vinyl Frame:Double Pane with Low-E: 6 0.350 2 Window 7: Vinyl Fmme:Double Pane with Low-E: 15 0.350 5 Wall 6: Wood Frame, 16" o.c.: 126 23.0 0.0 7 Wall 7: Wood Frame, 16" o.c.: 117 23.0 0.0 5 Door 2: Solid: 21 0.350 7 Wall 8: Wood Frame, 16" o.c.: 72 23.0 0.0 3 Window 8: Vinyl Frame:Double Pane with Low-E: 15 0.350 5 Wall 9: Wood Frame, 16" o.c.: 27 23.0 0.0 1 Wall 10: Wood Frame, 16" o.c.: 72 23.0 0.0 3 Door 3: Glass: 21 0.350 7 Wall 11: Wood Frame, 16" o.c.: 135 23.0 0.0 7 Wall 12: Wood Frame, 16" o.c.: 99 23.0 0.0 4 Window 9: Vinyl Fmme:Double Pane with Low-E: 20 0.350 7 Wall 13: Wood Frame, 16" o.c.: 18 23.0 0.0 1 Wall 14: Wood Frame, 16" o.c.: 117 23.0 0.0 6 Window 10: Vinyl Frame:Double Pane with Low-E: 15 0.350 5 The Development Group Block 2 Lot 12 Willowbrook Page 1 of 7 Basement Wall 1: Solid Concrete or Masonry: Window 11: Vinyl Frame:Double Pane with Low-E: Window 12: Vinyl Frame:Double Pane with Low-E: Basement Wall 2: Solid Concrete or Masonry: Basement Wall 3: Solid Concrete or Masonry: Basement Wall 4: Solid Concrete or Masonry: Window 13: Vinyl Frame:Double Pane with Low-E: Basement Wall 5: Solid Concrete or Masonry: Window 14: Vinyl Frame:Double Pane with Low-E: Basement Wall 6: Solid Concrete or Masonry: Basement Wall 7: Solid Concrete or Masonry: Basement Wall 8: Solid Concrete or Masonry: Basement Wall 9: Solid Concrete or Masonry: Basement Wall 10: Solid Concrete or Masonry: Basement Wall 11: Solid Concrete or Masonry: Basement Wall 12: Solid Concrete or Masonry: Furnace 1: Forced Hot Air: 92 AFUE 333 13.0 0.0 17 16 0.350 6 16 0.350 6 306 13.0 0.0 17 81 13.0 0.0 5 171 13.0 0.0 9 20 0.350 7 225 13.0 0.0 12 20 0.350 7 126 13.0 0.0 7 117 13.0 0.0 7 72 13.0 0.0 4 18 13.0 0.0 1 72 13.0 0.0 4 117 13.0 0.0 7 198 13.0 0.0 11 Compliance Statement: The pr osed building design described here is consistent with the building plans, specifications, and other calculations su mitted with t ermit appl' tion. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Ve ion 3.7.3 an comply h the mandatory requirements listed in the REScheck Inspection Checklist. 6 e ld & i� Builder/Designer Company Name Dat The Development Group Block 2 Lot 12 Willowbrook Page 2 of 7 REScheck Software Version 3.7.3 Inspection Checklist Date: 09/11/06 Ceilings: ❑ Ceiling 1: Cathedral Ceiling (no attic), R-40.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R-23.0 cavity insulation Comments: ❑ Wall 2: Wood Frame, 16" o.c., R-23.0 cavity insulation Comments: ❑ Wall 3: Wood Frame, 16" o.c., R-23.0 cavity insulation Comments: ❑ Wall 4: Wood Frame, 16" o.c., R-23.0 cavity insulation Comments: ❑ Wall 5: Wood Frame, 16" o.c., R-23.0 cavity insulation Comments: ❑ Wall 6: Wood Frame, 16" o.c., R-23.0 cavity insulation Comments: ❑ Wall 7: Wood Frame, 16" o.c., R-23.0 cavity insulation Comments: ❑ Wall 8: Wood Frame, 16" o.c., R-23.0 cavity insulation Comments: ❑ Wall 9: Wood Frame, 16" o.c., R-23.0 cavity insulation Comments: ❑ Wall 10: Wood Frame, 16" o.c., R-23.0 cavity insulation Comments: ❑ Wall 11: Wood Frame, 16" o.c., R-23.0 cavity insulation Comments: ❑ Wall 12: Wood Frame, 16" o.c., R-23.0 cavity insulation Comments: ❑ Wall 13: Wood Frame, 16" o.c., R-23.0 cavity insulation Comments: ❑ Wall 14: Wood Frame, 16" o.c., R-23.0 cavity insulation Comments: Basement Walls: ❑ Basement Wall 1: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation Comments: ❑ Basement Wall 2: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation Comments: ❑ Basement Wall 3: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation Comments: ❑ Basement Wall 4: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation Comments: ❑ Basement Wall 5: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation Comments: ❑ Basement Wall 6: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation Comments: The Development Group Block 2 Lot 12 Willowbrook Page 3 of 7 ❑ Basement Wall 7: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation Comments: ❑ Basement Wall 8: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation Comments: ❑ Basement Wall 9: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation Comments: ❑ Basement Wall 10: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation Comments: ❑ Basement Wall 11: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation Comments: ❑ Basement Wall 12: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation Comments: Windows: ❑ Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 2: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 3: Vinyl Frame:Double Pane with Low-E. U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 4: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 5: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 6: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 7: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 8: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 9: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 10: Vinyl Frame:Double Pane with Law-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 11: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 The Development Group Block 2 Lot 12 Willowbrook Page 4 of 7 �4wv 1�qw/ For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 12: Vinyl Frame:Double Pane with Low-E, U-factor. 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 13: Vinyl Frame:Double Pane with Low-E. U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 14: Vinyl Frame:Double Pane with Low-E, U-factor 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1: Glass, U-factor: 0.350 Comments: ❑ Door 2: Solid, U-factor: 0.350 Comments: ❑ Door 3: Glass, U-factor. 0.350 Comments: Heating and Cooling Equipment: ❑ Furnace 1: Forced Hot Air: 92 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Skylights: ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19. Vapor Retarder: ❑ Required on the warm -in -winter side of all non -vented framed ceilings, walls, and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for ail installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-11. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-6. ❑ Supply ducts in unconditioned spaces must be insulated to R-11. ❑ Return ducts in unconditioned spaces (except basements) must be insulated to R-2. ❑ Where exterior walls are used as plenums, the wall must be insulated to R-11. ❑ Insulation is not required on return ducts in basements. Duct Construction: ❑ Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened. ❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), The Development Group Block 2 Lot 12 Willowbrook Page 5 of 7 14116� mastic -plus -embedded -fabric, or tapes. Tapes and mastics must berated UL 181A or UL 181 B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. The Development Group Block 2 Lot 12 Willowbrook Page 6 of 7 rn Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Temperature (°F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Piping System Types Fluid Temp. Range(OF) Heating Systems Low Pressure/Temperature 201-250 Low Temperature 106-200 Steam Condensate (for feed water) Any Cooling Systems Chilled Water, Refrigerant and 40-55 Brine Below 40 NOTES TO FIELD: (Building Department Use Only) Insulation Thickness in Inches by Pipe Sizes 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" 1.0 1.5 1.5 2.0 0.5 1.0 1.0 1.5 1.0 1.0 1.5 2.0 0.5 0.5 0.75 1.0 1.0 1.0 1.5 1.5 The Development Group Block 2 Lot 12 Willowbrook Page 7 of 7