HomeMy WebLinkAboutRESCHECK - 06-00459 - 561 Twisted Willow - New SFR0600459
561 Twisted Willow Way-TDG
REScheck Software Version 3.7.3
Compliance Certificate
Project Title: The Development Group Block 2 Lot 12 Willowbrook
Report Date: 09/11/06
Data filename: C:\Documents and Settings\Scott\Desktop\TDG\Willow Brook Lot 12 rescheck.rck
Energy Code:
2003 IECC
Location:
Rexburg, Idaho
Construction Type:
Single Family
Glazing Area Percentage:
14%
Heating Degree Days:
8693
Construction Site:
1007 Artic Willow Dr.
Rexburg, ID 83440
Owner/Agent:
Scott Jacobson
The Development Group
PO Box 832
Rexburg, ID 83440
208-390-0230
soott@builtbytdg.com
Designer/Contractor:
The Development Group
Compliance: Passes Maximum UA: 428 Your Home UA: 336 -> 21.5% Better Than Code (UA)
Ceiling 1: Cathedral Ceiling (no attic):
1703
40.0
0.0
44
Wall 1: Wood Frame, 16" o.c.:
333
23.0
0.0
18
Window 1: Vinyl Fmme:Double Pane with Low-E:
6
0.350
2
Wall 2: Wood Frame, 16" o.c.:
306
23.0
0.0
14
Window 2: Vinyl Frame:Double Pane with Low-E:
20
0.350
7
Window 3: Vinyl Fmme:Double Pane with Low-E:
40
0.350
14
Wall 3: Wood Frame, 16" o.c.:
81
23.0
0.0
3
Door 1: Glass:
21
0.350
7
Wall 4: Wood Frame, 16" o.c.:
171
23.0
0.0
8
Window 4: Vinyl Frame:Double Pane with Low-E:
12
0.350
4
Window 5: Vinyl Frame:Double Pane with Low-E:
12
0.350
4
Wall 5: Wood Frame, 16" o.c.:
180
23.0
0.0
9
Window 6: Vinyl Frame:Double Pane with Low-E:
6
0.350
2
Window 7: Vinyl Fmme:Double Pane with Low-E:
15
0.350
5
Wall 6: Wood Frame, 16" o.c.:
126
23.0
0.0
7
Wall 7: Wood Frame, 16" o.c.:
117
23.0
0.0
5
Door 2: Solid:
21
0.350
7
Wall 8: Wood Frame, 16" o.c.:
72
23.0
0.0
3
Window 8: Vinyl Frame:Double Pane with Low-E:
15
0.350
5
Wall 9: Wood Frame, 16" o.c.:
27
23.0
0.0
1
Wall 10: Wood Frame, 16" o.c.:
72
23.0
0.0
3
Door 3: Glass:
21
0.350
7
Wall 11: Wood Frame, 16" o.c.:
135
23.0
0.0
7
Wall 12: Wood Frame, 16" o.c.:
99
23.0
0.0
4
Window 9: Vinyl Fmme:Double Pane with Low-E:
20
0.350
7
Wall 13: Wood Frame, 16" o.c.:
18
23.0
0.0
1
Wall 14: Wood Frame, 16" o.c.:
117
23.0
0.0
6
Window 10: Vinyl Frame:Double Pane with Low-E:
15
0.350
5
The Development Group Block 2 Lot 12 Willowbrook Page 1 of 7
Basement Wall 1: Solid Concrete or Masonry:
Window 11: Vinyl Frame:Double Pane with Low-E:
Window 12: Vinyl Frame:Double Pane with Low-E:
Basement Wall 2: Solid Concrete or Masonry:
Basement Wall 3: Solid Concrete or Masonry:
Basement Wall 4: Solid Concrete or Masonry:
Window 13: Vinyl Frame:Double Pane with Low-E:
Basement Wall 5: Solid Concrete or Masonry:
Window 14: Vinyl Frame:Double Pane with Low-E:
Basement Wall 6: Solid Concrete or Masonry:
Basement Wall 7: Solid Concrete or Masonry:
Basement Wall 8: Solid Concrete or Masonry:
Basement Wall 9: Solid Concrete or Masonry:
Basement Wall 10: Solid Concrete or Masonry:
Basement Wall 11: Solid Concrete or Masonry:
Basement Wall 12: Solid Concrete or Masonry:
Furnace 1: Forced Hot Air: 92 AFUE
333
13.0
0.0
17
16
0.350
6
16
0.350
6
306
13.0
0.0
17
81
13.0
0.0
5
171
13.0
0.0
9
20
0.350
7
225
13.0
0.0
12
20
0.350
7
126
13.0
0.0
7
117
13.0
0.0
7
72
13.0
0.0
4
18
13.0
0.0
1
72
13.0
0.0
4
117
13.0
0.0
7
198
13.0
0.0
11
Compliance Statement: The pr osed building design described here is consistent with the building plans, specifications, and other
calculations su mitted with t ermit appl' tion. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Ve ion 3.7.3 an comply h the mandatory requirements listed in the REScheck Inspection Checklist.
6 e ld & i�
Builder/Designer Company Name Dat
The Development Group Block 2 Lot 12 Willowbrook Page 2 of 7
REScheck Software Version 3.7.3
Inspection Checklist
Date: 09/11/06
Ceilings:
❑ Ceiling 1: Cathedral Ceiling (no attic), R-40.0 cavity insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
❑ Wall 2: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
❑ Wall 3: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
❑ Wall 4: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
❑ Wall 5: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
❑ Wall 6: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
❑ Wall 7: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
❑ Wall 8: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
❑ Wall 9: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
❑ Wall 10: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
❑ Wall 11: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
❑ Wall 12: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
❑ Wall 13: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
❑ Wall 14: Wood Frame, 16" o.c., R-23.0 cavity insulation
Comments:
Basement Walls:
❑ Basement Wall 1: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
❑ Basement Wall 2: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
❑ Basement Wall 3: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
❑ Basement Wall 4: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
❑ Basement Wall 5: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
❑ Basement Wall 6: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
The Development Group Block 2 Lot 12 Willowbrook Page 3 of 7
❑ Basement Wall 7: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
❑ Basement Wall 8: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
❑ Basement Wall 9: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
❑ Basement Wall 10: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
❑ Basement Wall 11: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
❑ Basement Wall 12: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul, R-13.0 cavity insulation
Comments:
Windows:
❑ Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 2: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 3: Vinyl Frame:Double Pane with Low-E. U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 4: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 5: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 6: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 7: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 8: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 9: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 10: Vinyl Frame:Double Pane with Law-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 11: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350
The Development Group Block 2 Lot 12 Willowbrook Page 4 of 7
�4wv 1�qw/
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 12: Vinyl Frame:Double Pane with Low-E, U-factor. 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 13: Vinyl Frame:Double Pane with Low-E. U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 14: Vinyl Frame:Double Pane with Low-E, U-factor 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1: Glass, U-factor: 0.350
Comments:
❑ Door 2: Solid, U-factor: 0.350
Comments:
❑ Door 3: Glass, U-factor. 0.350
Comments:
Heating and Cooling Equipment:
❑ Furnace 1: Forced Hot Air: 92 AFUE or higher
Make and Model Number:
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.
❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation.
Skylights:
❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19.
Vapor Retarder:
❑ Required on the warm -in -winter side of all non -vented framed ceilings, walls, and floors.
Materials Identification:
❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment must be identified so that compliance can be determined.
❑ Manufacturer manuals for ail installed heating and cooling equipment and service water heating equipment must be provided.
❑ Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or
specifications.
Duct Insulation:
❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-11.
❑ Return ducts in unconditioned attics or outside the building must be insulated to R-6.
❑ Supply ducts in unconditioned spaces must be insulated to R-11.
❑ Return ducts in unconditioned spaces (except basements) must be insulated to R-2.
❑ Where exterior walls are used as plenums, the wall must be insulated to R-11.
❑ Insulation is not required on return ducts in basements.
Duct Construction:
❑ Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened.
❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
The Development Group Block 2 Lot 12 Willowbrook Page 5 of 7
14116�
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must berated UL 181A or UL 181 B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500
Pa).
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the
heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
❑ Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
❑ Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
2.
The Development Group Block 2 Lot 12 Willowbrook Page 6 of 7
rn
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and Runouts
Heated Water
Temperature (°F)
Up to 1" Up to 1.25"
1.5" to 2.0" Over 2"
170-180
0.5 1.0
1.5 2.0
140-169
0.5 0.5
1.0 1.5
100-139
0.5 0.5
0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Piping System Types
Fluid Temp.
Range(OF)
Heating Systems
Low Pressure/Temperature
201-250
Low Temperature
106-200
Steam Condensate (for feed water)
Any
Cooling Systems
Chilled Water, Refrigerant and
40-55
Brine
Below 40
NOTES TO FIELD: (Building Department Use Only)
Insulation Thickness in Inches by Pipe Sizes
2" Runouts
1" and Less
1.25" to 2.0"
2.5" to 4"
1.0
1.5
1.5
2.0
0.5
1.0
1.0
1.5
1.0
1.0
1.5
2.0
0.5
0.5
0.75
1.0
1.0
1.0
1.5
1.5
The Development Group Block 2 Lot 12 Willowbrook Page 7 of 7