Loading...
HomeMy WebLinkAboutRECEIPT - 06-00441 - 2348 E Hwy 33 - MechanicalCOMFORT ZONE HEATING AND Allo CQNDIT[ON]NG Shortimorm Entire House For: ROMRELL E HYW 33, SUGAR, ID Job: Date: Aug 23,2006 By.0 0600441 EJ Hwy 33-Rom-rell It I Outside db (°F) -12 89 Method inside db (°F) 70 75 Construction quality assign TQ (OF) 82 14 Fireplaces Daily range - H Inside humidity (%) - 50 Moisture difference kgrlib} - -31 HEATING EQUIPMENT Infiftration Simplified Semi -loose d COOLING EQUIPMENT Make I rrt'I Comfort Products 90 2601 Make Tempsta r 48 29 Trade Tempsta r 144 4161 Trade 13 SEER N Series R22 AC 86 Model N9MP21 OOJ20** 131 2304 Cond N2A342A(G)HA1* 42 84 WIC 1 78 992 Coll EX*42 J **** +TD 1 18 10 Efficiency 90 AFUE 2301 Efficiency 13 EER 64 Heating input 100000 Btuh Sensible -cooling 2765D Btuh Heating output 92000 Btu h Latent cooling 1185D Btuh Temperature rise 78 °F Total cooling 3950x0 Btu h Actual air flow 1283 cfm Actual air flow 1283 cfm Air flow factor 0_Q18 cfrnlBiuh Air flow factor 0.046 cfm/Btu h Stafic pressure 0.50 in H2O Stabc pressure 0_50 in H20 Space thermostat 520 7409 Load sensible heat ratio 9.00 211 ROOM NAME Area Htg load C Ig load Htg AVF C[g.AVF 193 GREAT ROOM (Btuh) (Btu h) (Cfm) 1623 (Cfm) BATH 1 90 2601 629 48 29 BED 2 144 4161 1869 77 86 BED 1 131 2304 1813 42 84 WIC 1 78 992 221 18 10 MASTER BATH 143 2301 1386 42 64 MASETER BED 254 7237 2378 133 110 HALL 109 498 206 9 10 ENTRY 108 1579 390 29 18 LIVING 132 3319 1967 61 91 MECH 36 0 0 0 0 UTILITY 120 2356 169 43 S KITCHEN 520 7409 4575 136 211 DINING 140 7451 4184 137 193 GREAT ROOM 400 5173 1623 95 75 BONUS ROOM 413 10642 3210 196 148 STORAGE 84 0 0 0 0 BONUS BATH 174 4488 773 83 36 Printout certified byACCAto meet all requirements of Manual J 8th Ed. %e/r-jg htS.Qft Right -Suite Residential 6.0.53 R5R41065 C�1My Dac.jmentslWr€ghisoR H1fAC1ERfC GEE.rrp Calc = NI.#$ Orientation = N 0Ugi4 13:03:50 Page 1 Entire House Other equip loads Equip- @ Latent cooling TOTALS r1% #-% &�* ff , r'% A f v 1 U Printout certified by AICA to meet all requirements of Manual J 8th Ed. .1 VVrj(g tSC) Rig tt-S u fte Res ident aI6.0.53 RSR41065 CAM D ocumentsW rights oft HVADE RIC GEE.rrp Calc=MJB Orilentation--�N 1400 ill 2006 -Aug -24 13-03:50 Page COMFORT ZONE D EATING AND A[R CC N DITIONIN Buildit-IJ Analysis Entire House M0 Job: Cate: Aug 23, 2006 B: For-. ROMRELL E HYW 33, SUGAR, I D Location: Idaho Falls, Elevation: Lafitude: Outdoor: ID, US 4?41 ft 44ON Dry bulb (°F) Daily range (°F) Wet bulb (°F) Wind speed (mph) Indoor: Indoor tempe ram re (°F) Design TD ('F) Relative humidity (%,) Heating Coating Moisture difference (dr/lb) -12 89 Infiltration: - 34 (H) Method 60 Construction quality 15.0 7.5 Fireplaces Heati ng 70 82 30 36.2 Simplified Semi -loose 0 Cooling 75 14 50 -31.5 Component Btu h1ff Btu h % of Load Walls 5.7 76744 22.7 Glazing 28.7 112031 15.2 Doors 29.5 1860 2.5 Ceilings 2.1 5763 7.8 Floors 1.4 3765 5.1 Infiltration 4.6. 14189 19.3 Ducts 15221 22.0 Piping 0 0.0 Humidification 0 0.0 Ventilation 3960 5.4 Adjustments -0 2.4 Total 73703 100.0 ce :'.sr s Component Btu h/f? Btu h % of load Waifs 0.6 1784 6.3 Glazing 23.3 9084 31.9 Doors 6.7 420 1.5 Ceilings 1.1 29521 10_4 Floors 0.2 643 2.3 Infiltation D.4 1296 4.6 Ducts 10466 36.8 Ventilation 676 2.4 Internal gains 1150 4.0 Blower 0 0.0 Adjustments -0 Total 28470 100.0 Overall U -value = 0.065 Btuh/ftl-'F Data entries checked. Rlgtt-Sulte Resident at 6,0,53 RS 1065 +� .\ Docum nts\Wri h# oft H\ERIC EE.rrp Calc = MA Orlentation=N �; 460 a Intemal Gins �I e� I 1 FWrs 200u-2 13:03:50 Page 1 COMFORT ZONE Compottent Constructions HEATING AND AIR `°"°M°"'"G Entire House Job: Date: Aug, 2006 For-, ROVRELL E HYW 33, SUGAR, I D 1: Idaho FII,, ID, US Elevation: 4741 ft Outdoor: Dry bulb (°F) Daily range (°F) Wet bulb (°F) Wind speed (mph) Hewing -12 Construction descriptions Cool'ing 89 34 (H } BQ 7.5 Walls 12E-Osw: Wood stud frame, siding or stucco, no board insulation, R-19 cavity insulation Partitions 1 -0sw: Wood stud framer siding or stucco, no board insulation, R-13 cavity insulation Windows 61B-_ CLASS DBL PANE, dear low -e- BERG rated(SHGC=0.35) Doors 1 KO.- Metal door. fiberglass core, w4h storm Ceilings 1 x--38 ad: C ei rt n g u nde r vented atti c, o o rad i a rpt barrier , dark shingles, R-38insulation Floors 19C- 1 : Carpeted f lour over tight en do sed c ravel,, -11 wall R-19 blanket Indoor: 1 ndoor Tempe rata re (OF) Design TD (°F) Relative humidity (°/a) Moisture difference (gr/ib) Infiltration: Method Construction quality Fireplaces Heating 70 82 30 36.2 Simplified Semi -Idose 0 Coaling ?5 14 50 -31.5 Or Area -value Insall R HtgT Loss Cig HT'I Gai n (W) ( _O F - - F Btu h) (f (EM hftF) (EWh) ) ( hm ) ( h) 256 0.091 13.0 7.46 1910 0.33 84 n 690 0.0688 0.0. 28.7 3846 0.64 4. e 784 0.068 19.0 5.58 4372 0-64 501 S 487 O068 19.0 5.58 2718 0.64 31.1 W 699 0.068 19.0 5-58 3898 64 44-1 all 2660 0.0689 0.0 287 _ 0.64 1700 256 0.091 13.0 7.46 1910 0.33 84 n 141 0.350 0.0. 28.7 4047 11.5 1628 e 49 0.350 0.0 28.7 1406 37.7 1845 0.0 114 0.350 0.0 28.7 3281 20.6 2 360 W 86 0.350 0.0 28.7 268 373 3238 all 390 0.350 0.0 287 11203 23.2 9071 e 21 0.360 .0-0 29.5 620 6.66 1 s 21 0.360 0.0 29.5 620 6.66 140 W 21 0.360 0.0 295 620 6.66 140 all 63 0.360 0.0 29.5 1860 &66 420 2703 0.026 38.0 2.13 5 763 1.09 2952 2703 0.049 19.0 1.39 3765 024 643 Aw0VV10h1L!&C>ft Ri ft -Suite Res id n#i al 6.0.53 RSR41065 00 ug.- 13-.03-.50 :'y Document \Wr ghts t HRI EE.rr Cale-UJIS Orientafion=N Page 1 COMFORT ZONE HEATING ANS Alfa GONDITI IN ProjecidS u ary Entire House bo Job: Date: Aug 23, 2006 For: ROMRELL E HYW 33, SUGAR, ID Nates: Winter Design Conditions Outside db -'[Z OF Inside d� 7(] °F Design TD $2 OF Heating Summary Structure Ducts Central vent (52 cfm) Humidification Piping Equipment load lnf i1tration Method Construction quality Fireplaces Idaho Falls, ID, US Summer'Design Cond"Itions Outside db ss OF Inside db 75 °F Design TD 14 OF Daily rage H Relative humidity 50 % Moisture difference --31 gr1lb tensible Coaling Equipment Load Sizing 53523 Btu Structure 17328 Btu 16221 Btu h Ducts 'I 04fi6 E3tuh 3960 Btu h Central vest (52 cfrn ) 676 Btu h D Btu h Blower 0 Bich 0 Btu h 73703 Btu h Use manufacturer"s data n Ratelswing multiplier 0.94 Equipment sensible load 26762 Btu Heatin Area (ft� 331 Volume (fP) 26125 Air changes/hour 0.43 Equiv. AVF (cftn) 187 Simplified Semi -loose a Co 331q 25925 0.23 100 Healing Equipment Summary Make Intl Comfort Products Trade Tempstar Model N9MP21 OOJ20** EfficiencY Heating input Heating output Temperature rise Arcual air flow Air flow factor, Static pressure Spice thermostat 90 FE Btu h btu h OF cfm cwnlBtu h in H20 Latent Cooling Equipment Load Sizing Structure ,80 1 Btu h Ducts 244 Btu Central vent (52 (,.fm) -940 Biu h Equipment latent load 0 btu h Equipment total load 26762 Btu h Req. total capacity at 4.70 SHR 3.2 fan Co-oling Equipment Summary fake Tempstar Trade 13 SEER N Series Cond N2A342A(G.)HA1* Coil EX*42.1****+TD'S Efficiency Sensible cooling Latent cooling Total coaling Actual, air flaw Air flaw factor Stafic pressure Load sensible heat ratio Printout Certified by ACCA to meet all requirements of Manual J 8th Ed. VVrj j-jIt-Suite Res iden i aI 6.0.53 1065 : y Daeuments\Wghtsoft HVAGERIC GEE.rrpCali. = MJ8Orientation = 13 EER 27650 Btu h 11850 Btu h 39500 Btu h 12 $3 cfm 0_046 cf„igtun 0.50 in H20 1.00 2006 -Aug -4 1 :0:0 Page 1 COMFORTZONE HEAT SIG AN D AIR COSI DMGNIN. Right.. Worksheet Entire House Job` Date: Aug 23, 2006 B: 1 Roam name Entre House BATH 1 2 Exposed wall 39 8. 0 ft19_Q fit 3 Ceiling height �.9 ft d 8.� ft heat/cool 4 Room dimensions 9.0 x 10.0 ft 5 Room area 3311.b ftz 90.0 ff Ty Canst[udion U-valueDr HTM Area (ft2) Loyd Area (ftp Load numher (13t u h f f- °IF).(13tuhlffl or pe�rneter (ft) (13tuh) or perimeter (ft) (Btuh) Heat Caul Grass EVlP1S Heat Cool Grm NfP15 Heat Cool 6 VL 92E-0sw 0.068 n 5.55 0.64 83't 690 3846 x{41 0 0 a 4 -C� B'E 8 01.354 n 28.70 11.55 141 D 4047 1628 Q a o 0 12E-osw 0.068 e 5.58 0.64 854 784 4372 501 so av 446 51 (33 61B 0_350 e 28.70 37.65 49 0 1406 1845 Q o a o 1 1 11 K0 0.360 e 29.52 6.66 21 21 620 140 0 0 0 0 12E-0sw 0.068 s 5.58 0,64 623 487 2718 372 72 66 368 42 Gl B 0.350 s 28.70 20.65 114 Q 32$1 2360 6 d 172 324 Do 'i'i KD 0.350 s 29.52 6.66 21 21 62E1 140 0 0 6 Q Vj 12E-Osw 0.068 w 5.58 0-64 806 699 31398 447 01 0 D 0 E1 B 0.350 w 28.74 37_65 86 0 2468 338 D 0 0 0 11 KO 0-3601 w 20.52 6.65 21 21 620 1411 0 0 0 D P 120-05w 0.091 - 7.46 Q.33 256 256 191a 84 4 0 D D C 16&38 ad 0.026 - 2.13 "0.09 2703 2703 5763 2952 90 90 192 98 F 19C-19CSCp 0.049 - 139 0.24 2703 279 3765 643 90 19 125 21 6 c] AE D exw Non 13 -S Envelope loss/gain- 39334 14882 1304 329 12 a} lnfil7atial 14189 9290 693 63 b} Room ventilation Q D D 0 13 Intiemal gains Occupants @ 230 5 1150 0 0 Appliances @ 1200 4 4 0 0 Less exfen,al load o o D a Less transfer 0 (} Q [} Red isfibufion -Q -0 0 0 14 Subtotal 53523 11328 1996 392 15 Duct loads 30°/6 60°lo 16221 10466 30°16 60% 605 237 Total mom load 69743 27794 2601 629 Air reqs iced (cfm ) 1283 1283. 480. 29 ------ Pdntout cerfified by ACCA to asst all requirements of anu l J 8th Ed. RM .4CCPti -� Egra-Suitead n al 6.0.53 !065 .b\ Docum n � ri hoHV�.E I EE.r Calc=MJ8 Orientation 2006 -Aug -2413.03.50 Page 1 COMFORTZONE HEATING AND AIR CONDITIONING Right-„ Worksheet Entire House Job: Date: Aug 23, 2006 By: 1 Room name BED 2 BEI] 1 2 Exposed wail 26.0 ft 11.0 ft 3 Ceiling height S.D ft heat/cool 8_0 ft heatfcad 4 Room dimen 5ions 12.0 x 12.0 €t 1.0 x 130_5 it 5 Room area 144. t] ftz 13 0.5 ff Ty Construct -ion LI -value Or HTM Area mad Area Load number (fthiff2F) (Btuh/M or penm�eter (f) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NlPIS Hit Gaal Gross NIPIS Hit Cool 6 WI 12E-0sw 0.068 n 5.58 0.64 Q D 0 0 0 4 0 4 _ L ---G 61 B 0.350 n 28.70 11.55 01 0 0 a 0 [} Q 4 W 12E-0sw 0.058 e 5.58 0_64 16 16 $9 is 88 70 394 45 L2 fit B 3 D_350 e 28.70 37.65 C1 0 0 Q 18 D 517 678 11 11 KD 0.360 e 23.52 6.66 0 E} 0 p d 0 0 4 12E-0sw 0_068 s 5.58 0_64 96 71 396 45 0 Q 0 p T61 a 0_35o s 28.70 M65 25 0 717 516 o o a o ���co �.ssa s 29.52 6.66o o a o a o 0 0 '42E-0sw 0.468 w 5.58 0_64 96 96 535 61 D Q 0 Q 618 0.350 vv 28,7Q 37.65 D 00 0 0 0 0 0 11 KU 0-360w 29.52 fi.66 Q � � 0 D 0 0 {} P 12C-0sw 0.091 - 7.46 0.33 [] Q 0 0 D 0 0 0 C 1613-38ad 0_026 - 2.13 1 144 144 307 157 131 131 278 143 F 18C-19cscp 0.049 - 1.39 0.24 144 26 201 34 131 17 182 31 6 c) AE Q exaa rsion 24 -32 Envelope loss/gain 225 848 1367 864 12 a) lnfiltFation 948 sr 401 37 b} Room ventilation Q 4 0 0 13 ktlernal gains: Occupants @ 230 1 230 1 230 Appliances @ 1200 d 0 0 D Less extemat toad 0 E} D D Less transfer [] 0. 0 p Redisfri bution 0 U p 14 Subtotal 3193 1165 1768 'i 131 15 Qlct IdadS 30% 60% 9E8 704 30% 60% 536 683 Total moms load 4161 1$69 2304 1813 Ai r reqs Fred (Gim) TI 86 42 &t Printout certified b y AGCA to meet ail r2q uirements of Manual J 8th Ed. %^viii � # i [I �# nti l RSR41065 2006 -Aug -24 1 `0 : 0 ACOK C. -\My Documents rightsoft HVAIC GEE-rrp Calc = MJ8 Orientation = N Page COMFORT ZONE Right-,., Worksheet Entire House Job: [fat ,E Aug 23., 2006 B � P ri nfb ut cerfifi ed b ACCA to meed alf requirements of Manual J 8th Ed. rRigtft,-Suite Residential 6-0,53 3 4106,E 2006 -Aug -24 13:03:50 CAMY DocumentsWrightsoft HVADERIC GEE.rrp Calc = MJ8 Orientation = N Page 11 Roam same Wil I MASTER BATH 2 Exposed wall 6.fl ft 11.0 ft 3 Ceiling height 8.a ft Featlrool 8.0 ft heat/cod 4 Room dimensions X3.0 x 6.0 ft 13.0 x 11.0 ft 5 Room area 78.0 i#z 143.0 ff Ty Constnadion U -value Or HTM Area {ft2} Load Area La ad number {Biuhlft� or perimeter {ft} {Btuh} or perimeter (ft) (Biuh) Heal Coot Grams NIPIS Hit Coot Gross NfPfS Heat Cool BVr,�G 12E-0svv 0.068 n 5.58 0.64 D 0 0 Q a a b f} 61 B D_35(? n 28.70 11.55 Q f} 0 0 t} 0 0 D 12 E-0sw 0-068 e 5.58 0.64 48 48 268 31 8$ 72 40 i 46 61 B 0_350 e 28.7 37_65 0 0 4 0 16 0 459 602 19 17 KO O.360 e 29.52 6.66 0 0 4 0 a 0 0 D 12 E-0Sw 0-068 5 5.58 0.64 0 0 0 D 0 0 0 0 6.3 B 0.350 s 28.70 20.65 0 Q 0 0 Q (] 0 0 7'1100 0.360 S 29.52 6.06 Q 0 0 0 0 4 f] 0 12E-osw 0.068 w 5.5$ 0_64 o a o a o o a 0 L61 B 0.350 w 28J0 37.65o a a o 0 0 o Q 11 Ka o.360 w 29.52 6_56 0 0 a a 0 i} o 0 P 12C-0SW 0-.091 - 7.46 0.33 0 0 0 0 0 d 0 0 C 1613-38ad 0.026 - 2.13 1.09 78 78 166 85 143 143 305 156 F 19C-19C.Si�a Q.i749 - 1.39 x.24 78 6 1Q9 19 143 11 199. 34 B c} ASD eaccursion -37 -11 Envelope loss/gain 543 118 1365 827 12 a} Infiltration 21g Zp 401 37 b} Room ventilation o 0 Q 0 13 Intimal gains. Occupants @ 230 0 0 0 Q Appliances @ 1200 0 ❑ p 0 Less external load p p 0 p Less transfer 0 0 Q 0 Red iSiri bution p p 4 Q 14 Subtotal 761 138 1766 864 15 Ductloads 30°/n 60% 231 $3 30% 60°/o 535 522 Total room load 992 Z21 2301 1385 Air required (Cim) 18 10 42 64 P ri nfb ut cerfifi ed b ACCA to meed alf requirements of Manual J 8th Ed. rRigtft,-Suite Residential 6-0,53 3 4106,E 2006 -Aug -24 13:03:50 CAMY DocumentsWrightsoft HVADERIC GEE.rrp Calc = MJ8 Orientation = N Page COMFORT ZONE H i AND NR CONDI NIN Right.. Worksheet Entire House Job: Date: Aug 23, 2006 Byp- p- 1 Room rums MAE BED HALL wail I 41.0 ft 0-0 ft Ceiling height Ro ftheat/cool 8, 0 ft heat/ccd Room d 1 meri s ions 1.0 x 254:0 f 1-0 x 108.5 f Room ire. 254, 0 ff 108. 5 ft, ---- -- Ty Con struc#ion U -value Or WfiM Area (ft2) Load Area Load number (Btuhlf?-'F) (Btuh/W) or perimeter (fe) (Btuh) or perimeter (ft) (E3tuh) Heat Cool Grass N1PIS Hit Coo! Gross NlP15 Heat Coo! 6 12E-0sw 0.068 n 5.58 0_654 136 100 558 64 0 9 0 fl 61 B 0.35 D n 28.70 11-55 36 0 1033 416 0 0 i} d 12E-0sw 0.068 e 5.58 0-64112 'f'! 2 625 72 g D Il Q 61 B 0-350 e 28.70 37.85 d D d 0 0 0 d 0 11 11 KD 0.360 e 29.5 6.66 Q D 0 0 D D 0 Q 'E 2 E-0sw 0.068 s 5.58 0-64 D U d D 0 4 0 D 61 B 0.350 s 28.70 20.65 o a 01 0 0 0 o a 11 Ko 0_360 s 29_52 s_ss ❑ a a 0 o a o 0 W 12E-0sw 0.068 w 5.58 0.64 84 59 329 38 0 0 0 D 61 B 0.350 w 28.70 3.65 Q Q 0 0 0 a 0 0 MCD 0.360 w 2E3.52 fi_6 21 21 fit C1 940 [} 0 0 Q P 12C-Osw 0.091 - 7.45 0.33 4 0 0 D Q D 0 D C 96B-38aci 0.026 - 2.13 1.09 254 254 542 277 109 109 231 118 F 19G19CStp 0.049 - 9.39 0.24 254 41 354 64 309 a 151 28 6 cj AE excursion -180 -18 Envelope loss/gain 4460 886 382 129 12 a) Infiltration 9495 936 0 d t)) Room verrti�ation 0 0 01 0 13 Internal gains: Occupants @ 230 2 460 d 0 Appliances 1200 Q 0 D t] Less exterrta I load 4 0 0 0 Less transfer 0 Q 0 Q Red istribut Ion 0 Q p 0 14 Subtotal 5554. 1483f. 382 129 15 Duct It�ads 30% 60°% 1683 895 30% OOgI9 116 78 Total room load 7237 2378 498 206 Airrequired (cfm) 1331 110 9 10 Pdntout cerfified by ACOA to asst all .r qu I rams nts of Manual J 8th Ed. Vst-Suite Residential 6.0,53 RSR41065 2006 -Aug -24 13--03-,50 AMY DocurrientsWrightsoft HVADERIC GEErrpal = MJ8 Orientation = N Page 4 COMFORTZONE H F-AnNG AND AIR CONUMON I N Right-,,,,. Worksheet Entire House Job: Date: Aug 23, 2006 B: 'E Room nye -NDU ]";;I. ENTRY Envelope i iia in 1030 ll11lNG 2 Exposed wall 112 a) In fi Itrat ion 182 17 5.0 ft b Room veMilation 11.0 ft 3 Cei-ling height 13 Inlemal gala& Occupants Q 230 0 0 8.0 #t heatictd 8_0 ft 0 heatfcoa! 0 4 Room dimensions Less extwel load 0 0 9.0 x 12.0 fit 11.0 x 12.E ft 5 Room area Redi tributt 0, 10 8. 0 fl? 0 0 14 132.0 ff 1212 243 2547 Ty Construction 15 Ck HTM 147 Area (f� 0% 772 Load Arm (f��}} 15791 Load 3319 i�uiii� �7U�,-value (DEUhfi -'F) Air ru iricft ffltuh/ff) or ��i��� (ft) (Btuh) +1 or �ni�Gl .� l' Y (Btuh) Heat Cool cross NlPrs Hit cook Gross NrR/s Heat cook 6 W 12 E-0sw 0,068 n 5.58 0.54 D 0 0 [i 0 0 D 0 61 B 0.350 n 28.70 11.55 iJ 0 Q E] 0 D 4 0 12E-Osw 0.068 e 5.58 0.64 4 0 0 D 0 0 0 0 -C, 61 B D.350 e 28.0 37.65 D D 4 0 0 0 4 0 11 D 7 1 eco 0.360 e 29.52 6.66 o a o 0 a a o 0 12E-0sw 0.068 s 5.58 0.64 40 19 1(36 12 88 43 240 27 81 B 0.350 s 28.70 20.65 0 0 0 45 0 1291 929 '! 1 KO 0.360 S 29.52 6.66 21 21 620 140 0 D 0 Q 12F-0sw O.OfiB vv 5.58 0.64 U 0 0 4 0 0 0 D 61 B 0,350 w 28.70 37.5 0 0 0 0 0 4 0 D 11 K4 0.360 w 29.52 S_66 Q 0 0 [] 0' Cl d 0 P 12 C-0sw 0-091 - 7.46 0-33 0 0 0 D 48 4$ 358 16 C 1613-38acf 0_026 - 2.13 1_09 72 72 154 79 34 34 72 37 F 19G19cscp 0.049 - 1.39 0.24 148 5 150 26 132 11 184 31 b ) At U eXCU M1011 -NDU ]";;I. Envelope i iia in 1030 227 1 1 f1 112 a) In fi Itrat ion 182 17 401 37 b Room veMilation 0 0 0 0 13 Inlemal gala& Occupants Q 230 0 0 0 Appliances P. 1200 0 0 0 Less extwel load 0 0 0 0. Les transfer 0 0 Redi tributt 0, 0 0 14 Subtotal 1212 243 2547 1226 15 Duct I oad s 300/ % 367 147 % 0% 772 741 Total room load 15791 0 3319 1967 Air ru iricft 29 1 +1 1 Pdntout certified by ACCA to meet all requirements of Manual .] 8th fid. ,4zt=_. Right -Suite Resider of 6.0.53 RSR41065 2006 -Aug -24 13:03:50 ACCK CAMP DocurnentsWrightsoft HVAC\ERIC GEE.rrp Calc = I J8 Orientation = N Page CFT ZONE HEATING AND .MR CON DMOMN L Right-. VVorksheet Entire House Job: Date: Aug 23, 2006 : 1 Roam name MECFi UTILITY 2 Exposed wall B_o ft o.o ft 3 Ceiling freight S_Q it heaticoc�4 8.D ft hea#{cool 4 Room di-reensivr�s 6.0 x 6.0 ft 20.0 x 6.(l f# 5 Rooms area 36_a fl? 120_0 ftz Ty CcxistrudaQn U. -value Or HTM Area (fn load Area (fF) Load number (Btuh1ft2-'F)'(Btuhlff) or pe�ime#er (Ft) (Btuh) or perimeter (#) PUN Nit coot Gross WPrs Heat cool cross NlP/S Hit cool s w� 12E-asw o_oss n 5.58 0.64 v a o o a o a o spa 0.350 n 28.70 11.55 a 0 0 a o a o 0 12E-asw OMB e 5_58 0-64o o a o 0 o a o .-G 61 B 0.350 e as.-ra 37.65 o o a 4 0 o a a 11 I1xo 0.360 e 29_52 s.ss o o 0 0 o Q a o 12.E-0sw 0.408 s 5.58 0_64 0 0 0 d 0 a b Q 61B 0_350 5 28.70 20_65 0 Q 0 Q 0 D 0 0 11 KO 0.36 Q S 29.52 6.6E 0 0 D d Q 0 0 Q 32E-0swr 0.068 w 5.58 D.54 48 48 258 31 0 0 0 4 T -G 51 B 0.350 w 28.70 37.65 D 4 D D 0 {} D 4 11 KO D.360 w 29.52 6.66 0 D 0 Q 0 0 Q Q P 12C-D5w 0.091 - 7.46 0.33 48 48 358 16 160 160 1 � 94 52 C 16B-38ad 0.02E - 2_13 9.49 0 D o o D 0 0 D F 19C-19csC] 0.049 - 1.39 0.24 36 fi 50 9 120 {} 167 29 6 c) AE exaursivn -9 Envelope loss/gain 876 47 1361 72 12 a} In fi lUation 219 20 o a b} Roam ventilation 0 0 73 Entamal gains Occupants @ 230 0 0 D b Appliances A 1200 0 0 0 0 Less extemai load a o a a Less transfer Q o 01 a Redistribution X95 -67 447 33 14 Subtotal U U 188 106 15 C]liCt IDadS 30°/o 60% d 4 30% 6D% 548 64 Tot2V room load 1 U 0 2356 169 Airrequired [cfin] 4 Q 43 8 Pdntau#certified by ACCA to meet all requirements of Manuai J 8th Ed. 1tght-- ui Feesidenfi I . . 1065 2006 -Aug- 13:03:50 ACCA CWy DocumentsWrightsoft HVARIC E .rrp Calc = MJ8 Orientation = N Page [i COMFORT ZONE Right-.. Worksheet Entire House Joh.- [date: Aug, 2006 1 Roam name KdTCHEN DINING 2 Exposed wall 32, b ft 34. o ft 3 Ceiling height 8.0 ft heaticod S.0 it heaticooi 4 Roam dimensions 26 x 2Q.0 ft 14.0 x 1[3.0 ft 5 Room aroma �2�.0 i� 14 O.0 ff Ty Con. struc#ion iJ-value Or HTM Area (fly Load Area (iF) Load number (Biuhlf� °F) (Btuhlft� or perim�er (it) (Btuh). or perimefer eft} (Btuh) Heat Coal Grass NIPIS Heal Cool Gross NfPlS Heal Cool 5 V,U 12 E-0sw 0.068 n 5.58 0�� 9689 45 2 52 912 72 X10 � 46 sig o_350 n 28.70 11_56 15 o 430 173 ao a 1148 462 VV 12E-osw 0,068 e 5.58 0.64 o 0 0 o ao 44 245 28 61 B 0.350 e 28.70 37.65 o 0 o a 15 o 430 565 11 11 KD 0.360 e 29.52 6_66 0 fl 01 0 21 21 620 140 12E-t}sw 0_068 s 5.58 0,64 f} 0 0 D 0 0 0 0 61 0_350 s 28.70 2.65 0 0 a a Q a fl d 11 KO 0.360 S 29.52 6.66 d Q Q Q 4 0 0 0 W 12E-0sw 0.468 w 5.58 0_64 160 120 6E9 77 80 50 279 32 1j, 61B 0.35{) w 28.74 37.85 40 fl 1148 156 30 D 861 1130 11 KO Q.360 W 29.52 6.66 0 0 a D 4 0 Q 0 P 'I 2 C-OSw 0-091 - 7.46 0.33 0 0 0 U d 0 U D C 16&38 ad 0.026 - 2.13 1.09 304 304 648 332 140 140 298 153 F 19C-19cscp 0.049 - 1.39 0.24 520 32 724 124. 140 34 195 33 6 C} AEI] excursion 449 -93 Enveiope losslgain 4072 2712 4479 295 12 a) tngfration 1167 1a'7 1239 T1s b) Room ventilation 0 0 0 Q 13 intemaf gains: Occupantsa� 230 0 0 0 1 1 0 Ap0iances (g� 120D 0 0 Q D Less externa I load 0 d 0 d Less transfer 0 0 0 d Red Istnbution 447 33 D ❑ 14 Subtotal 5685 2852 5I1$ 250$ 15 Duct IOadS 30°/a 64°Io 1723, 723 1723 30% 60°Ia 1733 1575 `I'ot31 rocxrt load 7409 4575 7451 4184 Air required (cftn) 136 211 1371 193 Printout cerci#ied b y ACGA to meet al r2S uirements of Manual J 8t Ed. Pi ht -Suite Res yin al . _ 41 Ok CAMy DocumentsWr-Ightsoft HVAOERIC GEE.rrp Calc - MJ8 Orientation ug -4 13:03:50 Page 7 COMFORTZONE HEAMNG ANO AIR CCM DITIONIN Right-.. Worksheet Entire House M Job: Cate: Aug 23, 2006 1 roam name GREAT ROOM $onus Roonn 2 Exposed wall 20.0 ft 79.4 ft 3 Ceiling height 8.0 ft heat/coot 7.6 ft heat/cool 4 R001'11 dlfYlef'15iCif15 20.0 X 20.0 f# 1.0 X X113.0 ft 5 Room area 40 0_ D ff 413.0 ff Ty Construction U -value Car HTM Area M9 Load Area (M Load number (BtuhIft2-F) (Btuhlffl-) or perimeter (it) (B#uh) or perimeter (ft) (Btuh) Heat Cool Gross NIP1S Fieaa'f X004 Gross NIPIS Heat Cool B W 12E43sw 0.068 rt 5.58 0.64 160 110 613 70 61 fit 339 39 -G 61 B 0.35 n 28.70 11.55 50 (l 1435 677 0 fl 0 0 V� 12E-0sw 0.068 e 5.58 0.64 fl 0 Q 0 175 175 975 112 61 B 0.35 0 e 28.70 37.65 0 0 d D {} D 0 D 91 11 KO 0-360 e 29.52 6.66 f} d a a 0 0 D 0 VV 12E-0sw 4.058 s 5.58 0.64 d 0 D D 944 132 738 85 61 0.350 s 28.70 20.65 a o 0 0 1.2 a 344 248 91 KO 0.360 S 29.52 6.65 0 (} Q 4 0 D D D W 12E-0sw 0.068 w 5.5$ 0.64 D 4 0 0 220 204 1140 131 61 B 0.350 w 2$.70 375.5 Q a 0 0 16 0 459 502 11 K4 0.360 w 29.52 &66(7 d 0 0 a 0 0 4I P 12 C -05w 0-091 - 7.46 0.33 0 Q 4 0 0 Q D Q G 16&38aci 0_026 - 2.13 1.09 288 298 635 325 413 413 881 451 F 19G19C5Cp 0.049 - 1.39 0_24 440 20 557 95 99 299- 57 415 71 6 C) AE eatourssari -123 -13 Envelope loss/gain 3241 945 5292 1726 12 a} Infiltration 729 67 2736. 250 b} Room ventilation 4 a p 13 Inilemal gains: Occupants @ 230 0 0 0 Q Appliances @ 9200 Q 0 0 Q Less external load v a a a Less transfer d 0 {] 0 Red iStribution Q 0 139 26 14 Subtotal 3970 1012 8167 2001 15 Duct foads 30% 50% 1203 617 30°/n fid% 2475 1,209 Total room load 5173 1623 10642 3210 Arirrequlfed (CiTn) 95 75 195 148 P ri n to ut cerbfied b y ACOA to m e et l I requi reme ntsof M an u l J 8th Ed. � r"I+ i i -SuiteResidential {0,53 1065 2006 --Aug- 13:03:50 �� Wly Documents .ri h- HVADERI EE_rrp Calc= J rientatfon = Fuge COMFORTZONE H _nMG AND AIR CDNOMONING Right,, Worksheet Entire House .fob: Date: Aug 23,2006 :. .4CC;A. P ri n to ut certfi ed b y ACCA to melt ] I reg u I rI' a nts of M can u l J 8th Ed. %e%wrw-II-tRight-Suite Ides idnti al 6.0.53 RSR41065 CAMV DocumentsWrightsoft FS IC GEE.rrp Calc = MJ8 Orientatic)n 2006 --Aug- 13:03:50 Page 9 Room nine STORAGE 80NiJS BATH 2 Exposed wall 7A ft 36.0 ft 3 Ceiling height 7.8 ft heat/cod 7.6 ft heat/rood 4 Roam dimensions 7.0 x 12_0 ft 1.0 x 174.0 ft 5 Room area 84.0 fig 1i4.0 fl? Ty Constnrdivn U-va#ue Or HTM Area (fl?) Load Area (W) Load number (BtuhlftI-°F) (Btuh!f?) or perimeter (f) (Btuh) or perimeter (ft) (Ruh) Heat Coni Gross NIPIS Hof Cool Gross NlPIS Heat Coo! 6 W 12E-0sw 0.068 n 5.58 x_64 0 0 0 0 137 137 763 87 61 B 0.350 n 28.70 11.55 fii 0 0 t] 0 d {? 0 Vj 12F-0sw 0.068 e 5.58 0.64 0 D 0 0 46 46 254 29 61$ 0.350 e 2$.71D 37.65 Q U a I? Q 0 0 4 11 11 K0 0.3613 e 29.52 6_66 D 0: Q Q d 0 0 0 12E-0sw 0.068 s 5.58 Q._64 53 63 297 34 o 0 0 0 T----nG 61 B 0_350 s 28.70 2.65 D fl 0 D 0 0 0 D 11 KO 0.360 s 29.52 6.66 0 Q a 0 0 Q 0 Q 12E-0Sw 0.068 rry 5.58 0.64 0 0 [} D 91 91 5509 58 -G 61 B 0.350 w 28.70 37.65 0 D [l 0 0 0 0 01 i iCp 0.3f � w 29.52 6.66 0 0 Q D 0 0 0 0 P 12C-0sw 0.091 - 7.46 (}.33 0 4 0 0 D 0 0 0 C 16&38a'i 0.(726 -- 2.13 1.09 84 84 179 92 174 174 371 790 F 19C-19CSCp 0.049 - 1.39 0_24 Q 0, U 0 D fl tl 0 6 c) AE D eacau rsion -16 -52 'Envelope #osslgaPn 475 110 1897 313 12 a} Infiltration 242 22 1247 174 b} Room ventilation D 0 4 0 13 Intimal gains: Occupants @ 234 0 0 0 0 Ap pl iancEs Q 1200 0 Q 0 0 Less external load 0 0 0 0 Less transfer D 0 0 0 Red istribLtian -718 -132 301 55 14 Subtotal Q 0 3445 482 15 Duct 1 Ovid S 30% 60% d 0 30% 60% 1044 291 Total mom load D 0 4488 773 Air requ iced (cfm) 0 0 $3 ?,B .4CC;A. P ri n to ut certfi ed b y ACCA to melt ] I reg u I rI' a nts of M can u l J 8th Ed. %e%wrw-II-tRight-Suite Ides idnti al 6.0.53 RSR41065 CAMV DocumentsWrightsoft FS IC GEE.rrp Calc = MJ8 Orientatic)n 2006 --Aug- 13:03:50 Page 9 COMFORTZONE HEAT NC AND AIR CON C MOVING Right-,,., Worksheet Entire House Job- Date: Aug 23,2006 B: 1 Room name BONUS BED 2 Exposed wait 54.0 ft 3 Ceiling height 7.6 ft f1eat1COQ1 4 Room dimen sEons 1.0 x 238.E ft 5 Room arm 23s_0 ft' Ty Cons€rudion U -value Or HTM Area (fid Loac! Area Load number (Btuhlff-°F) {$tuhlftx} or perimeter {ft} (Btuh) or perimeter Herat Caul Grass NIPIS Heat Cool Gross NIPIS Heat Cool 6 1f�I 12E-Osw 4.068 n 5.58 464 129 129 720 83 �..G 61 B 0.350 n 2$.70 11.55 0 Q Q D VV. 12E-asw 0.068 e 5.58 0.64 122 122 678 -786't $ 0.350 e 28-70 37.65 D 4 0 0 11 11 KO 0-360 e 29.52 6_66 Q 0 0 0 12E -05w 0.068 s 5.58 0.64 129 103 574 66' G-8 61 B 0.350 s 28.70 20.65 26 d 766 544 11 KD 0.360 s 25.52 6.66 Q d 0U W 12E-0sw 0.068 w 5.58 0.64 30 30 170 'k3 P--nG 6'# B 0-350 w 28.70 37.65 d 0 0 O 11 Ko 0.360 w 29_52 6.66 a o a Q F' `i 2 C-0sw 0.091 - 7.46 0.33 0 Q 0 0 C 16B-38ad 0.026 - 2.13 1.09 23E 236 503 258 F 19C-19cscp 0.049 - 1.39 0_24 0 t] 0 0 6 c) AE excursion -Z Envelope loss/gain 3400 1045 12 a} Infiltration 1870 171 b) Room ventilation 0 0 13 Entemal gains Occup ants @ 230 1 230 Appt€ar3oes @ 1200 0 Q Less external load Q Q Liss transfer 0 0 Red islribut ion 278 51 14 Subtotal 5549 1497 15 Duct I oad 5 30% 60% 1682 9[}4 Total mom load 7230 2401 Aj r required (Cfm) 133 111 Pdniout certified by RCCA to meet alb r�quiremer�ts of Manual J 8th Ed. PP�OI� II IS I I l i l i l lyYtr� i 114 i i -u� Y i� lY9 it i�Y�ll �i �mr�w � ,.Rigil-Suite Residential 6,0.53 -41065 2006 -Aug -24 13.03:50 ACC& CWY DocumentsWrightsoft HVAOERIC GEE,rrp Calc = MJ8 Orientation = N Page 1 a SECOND FLOOR Job ff; Perfo ed for:, ROMRELL EHYW 33 SUGAR, I Scale-, 1 : 114 Page I Right -Suite Residential 6.0.53 RSR41065 2006 -Aug -24 1:0: AM ' D u rpt \ rij f oft WAC\.. f bo COMFORT ZONE Duct System Summary HEA'] NG AN Dal R CON DFrIG N ING Entire House 0 J [dateAug, 2006 For: ROMRELL E HYW 33, SUGAR, ID 15,4 BE BE W1 W W W HA EN M UT F F Ali F F B 13 B C Design Heaiu ng Cooling External static pressure 0.50 in H20 o_so in H20 Pressure lasses 0.29 in H20 0.29 in N24 Available static pressure 0.21 in H2O 0.21 in H20 Supply 1 return available pressure 0.1310.08 in 1-•i20 0.13/0-08 in H20 Lowest faction rate 0.028 iN'fQaft 0.Q28 in/100ft Actual air flow D 2 1283 c{m 12g3 Cfm Total effective length (TEL) ShMt X64.0 737 ft 15,4 BE BE W1 W W W HA EN M UT F F Ali F F B 13 B C ,Q= vv n Ri g It- u fte Re s id inti a 16x0.53 RS R 41065 )CC& :Wy DocurnentsWrightsoft FIVACERI `EB_rrp Calc = MJ8 Orientation 200 --Aug- 13:03:55 Page 1 Design Htg CIS Design Diarn Rett Duct Actual Ftg.Egv Name (Btu h) (ctn) (cfrn) FR (inn) Size (in) Matl Ln (ft) Ln (ft) :Trunk TM I n 2601 4$ zg 0.0-40 s ox o ShMt 72.0 245.a st2B D 2 c '1869 TI 86 0,043 6 Ox D ShMt X64.0 230.0St2A Q I c 1 813 42 84 0.042 fi Ox 0 ShMt 62.0 240.0 st2G C I h 992 18 10 0.042 6 Ox D ShMt 60. d 240.0 st2B ASTER BATH c 13$6 42 64 0_D41 s Ox o ShMt 61.0 245.0 st2B LSETER Bio n 3619 67 55 0.043 s ox o ShMt 75.0 220-0 stzA ,SETER gEo-a h 3s19 67 55 0.040 s oxo ShMt 86.0 230.0 'st2,13 LL G los s 10 0.000 v Ox 0 ShMt 0.0 0-0 TRY h °�579 29 1$ 0.045 fi (7x0 ShMt 42.0 240.0 sY1A 'iNG c 1967 fit 91 0.045 6 Ox 0 ShMt 36.0 245.0 si2A ILIT' h 2355 43 $ 0.0731 6 Ox 0 ShMt 13.E 160.0 st4 -CHEN-A G 2288 ss gas 0.101 s Ox 0 ShMt 20.0 105.0 5t5 -CHEN C z2-88 ss jos 0.066 s ox 0 ShMt 26.0 165.0 st4 4ING c 4184 137 193 0.063 6 Ox 0 ShMt 44.0 155.0 st4 EAT ROOM' h 2587 48 37 0.043 6 ox U ShMt 57.0 235.0 s12A EAT Roon,rA h 2587 48 37 0..042 s ax a ShMt 46,0 250_{ si2A 1rvvs ROOM -A h 5321 98 74 0.028 6 Ox 0 ShMt X7.1 394.0 st3A 'NUS ROOM h 531 98 74 0.029 6 Ox D ShMt 52.1 385_0 st3A ANUS BATH h 4488 $3 36 0.036 s ox o ShMt 42.3 310.0 5t3 'Nus BED h 7230 133 ill 0.043 6 Ox D ShMt 47.7 245.0 st3 ,Q= vv n Ri g It- u fte Re s id inti a 16x0.53 RS R 41065 )CC& :Wy DocurnentsWrightsoft FIVACERI `EB_rrp Calc = MJ8 Orientation 200 --Aug- 13:03:55 Page 1 .41.1 wrqcjhtsvft R9K'Sui#e Resident aifi.Q.53RSR41Q65 CK C:IMy DawmentslWrightsoft hiVAG1ERIC GEE.rrp Calc = MJ8 Orientation = N 2006 -Aug -24 13-103-55 Page Trunk Htg CIg Design Veloc Diam Rect Duct Duct Dram Name Type (ckn) (cfrn) FIR (fpm) ("in) Size (in) Material Trunk st3A Peak AVF 196 148 0.028 352 10 8 x 10 ShtMetl st3 st3 Peak AVF 411 295 0.028 411 13 8 x 18 ShtMetl st4 St -2A- Peak AVF 546 56 7 0.040 567 13 S x 18 ShtMetl st4 st4 Peak AVF 1206. 1168 0.028 517 19 8 x 42 ShtMetl st1 st1 Peak AVF 1274 1273 0.028 546 19 8 x 42 ShtMetl 8 sty Peak AVF 68 106 0.101 475 6 8 x 4 ShtMetl st1 sY2B Peak AVF 217 242 0.040 435 10 8 x 10 ShtMetl sY1A sY2C Peak AVF 42 84 0.042 188 7 8 x 8 ShtMetl st2B wrqcjhtsvft R9K'Sui#e Resident aifi.Q.53RSR41Q65 CK C:IMy DawmentslWrightsoft hiVAG1ERIC GEE.rrp Calc = MJ8 Orientation = N 2006 -Aug -24 13-103-55 Page Grill Hag CIg TEL Design Veloc Dram RectSize Stud/Joist duct Type Name Size (ire) (CfM) (CfM) (ft) FR {fpm} (in) (*In) Opening {in} Mati Trunk rb3 ox 0 180 110 222_' 0.038 286 9 2-14x3.25 2-10x9 SJSp rt3 rb4 Ox 0 321 442 182.0 0.046 465 12 3-14x3.2 3-1 ax's 4 SJSp rte rb1 Ox 0 158 100 218.0 0..039 249 8 2-14x3.25 2-1 Ox9 SJSp d2A rb5 ox 132 173 X77.(3 0.030 273 9 2-14x3.25 2-10x9 SJSp rt2A rbc 0x0 94 75 255.E 0.033 297 7 14x3.25 1f3x5 SJSp rt2A rbfi Ox 167 199 296.0 0.02$ 315 10 2-14x3.25 2-1+Dx9 SJSp rt2A rbc Ox 231 185 0.0 0.000 731 0 14x3.25 1 0x5 SJSp wrqcjhtsvft R9K'Sui#e Resident aifi.Q.53RSR41Q65 CK C:IMy DawmentslWrightsoft hiVAG1ERIC GEE.rrp Calc = MJ8 Orientation = N 2006 -Aug -24 13-103-55 Page Trunk Htg Clg Design Veloc Diam Rect Duct Duct Name Type (Cfm) (Cfm) FIR (fpm) (in) Size (in) Material Trunk rt1 Peak AVF 1052 1098 0.028 520 18 8 x 38 ShtMetl rt2 Peak AVF 872 988 0.028 468 18 8 x 38 ShtMetl rt1 rt3 Peak AVF 180 110 0.038 406 9 8 x 8 ShtMetl rt1 rt2A Peak AVF 551 547 0.028 451 14 8 x 22 ShtMetl 02 wrqcjhtsvft R9K'Sui#e Resident aifi.Q.53RSR41Q65 CK C:IMy DawmentslWrightsoft hiVAG1ERIC GEE.rrp Calc = MJ8 Orientation = N 2006 -Aug -24 13-103-55 Page COMFORT ZONE H EATING AND Al CONDI` 10N[N AED Assessment Entire House 0 Job: Date: Aug 23, 2006 For-. ROMRELL E HYW 33, SUGAR, ID Location: Idaho FII, Elevation : Latitude: 4D, US 441 ft 44°N Outdoor: Dry bulb (°F) Daily range (T) Wet bulb (°F) Wind speed (mph) Heating -12 15.0 Cooling 89 34 ( H 60 7.5 Indoor: Indoor temperature (17) Design TD (T) Relative humidify (%) Moisture difference (grilb) Infiltration: } Method Construction quality Fireplaces Heating '0 82 30 35.2 Simplified Semi -loose 0 Cooling 75 14 so -31.5 Hourly Glazing Load 0 211 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Da *00 Hourly mak' Average AED 1 mit Maximum hourly gi ing load exceeds average by 30.1%. House rifles not have. alley uate exposure diversity (ASD), based on AED limit of 30%. AED excursion: 13 Btuh (PFG - 1.3*AFG) ArltRigft-SufteResidenbal6.0-53RSR41065 JCOk CWY Dow m entsk rig his oft H VAC\E RIC GEE _ Calc=MJ8 Ohentafion=N 00.0-4 13:30:18 Page 1