Loading...
HomeMy WebLinkAboutSTAFF REVIEWS - 06-00366 - American Construction Supply1 TY REXBURG , OW -- - America's' Fani4y Community October 24, 2006 Review Action Permit Number: 06 00366 Project Name: American Construction Supply Project Type: Review Item Commercial New Planning Staff Review Development Standards Review Parcel #'s RPRAIRCPO 10060 0 Actions Rewired for Approval design of building discussed in 81171p6 P&Z Meeting, Developer agreed to the following: To put in two windows along the side of building to break up the facade. 2. het the fence back 15 feet from and landscape around it. 3. Pedestrian connection from right of way right of way staewalk to entrance sidewalk not required.. 4. 6 foot landscape trip between building and sidewalk not required. P.0 Box 280 19 E Main St. Rexburg, Idaho 8344 Phone (2Q8) 359-300 Fax (2Q8) 355-3022 * i 6 08/22-/2006 �'jVG 400PO" 1 N�zaa �4 ITY0F .REXBURG c America'S Family Comnju �i � October 24, 2006 '1 Permit Number: 06 00366 Project Name: Project Type: Review !tern Review Action American Construction Supply Commercial New AdministrativIXeWew .. Permit Tech Notes Parcel Ws 06% Actions Required fob ro al Plumbing & mechanical contractor information signatures needed. Energy Cafes & Lighting needed. RO Box 280 19 E. Maid St. Rexburg, Idaho 83440 Phone (20$) 359-3020 Fax (208) 359-302 App—roved ' r t REXBURGnw — A eric s Family Conmiunily October 24, 2006 Review Action Permit Number: 06 00366 Project Name: American Construction Supply Project Type: Commercial New Review item Building department Review Complies with approved Site Plan Review Accessibility Review Exiting Review Building Code Firs Compliance Review Structural Review Height and Area review O in Type Compliance Water and Sewer Service Plumbing Potable Water Review Plumbing Sewer Drain Review Plumbing Storm Drain Review Mechanical Review Energy Conservation milli n Review Waste Water Grease Trap Form Waste Water Application RO Box 280 19 E. Main St. Rexburg, Idaho 83440 Phone (20$) 359-3020 Fax (208) 359-3022 Act iv.ns�Rec wired for Ap�rowal�A�prqv—e d- Site plan has been reviewed. 08/21/2006 Provide fall handicap accessibie restrooms. D812/21Q6 Thresholds at entry doors must meet accessible standards. Meets code requirements. 08/21/2006 Provide drafstopping as per IBC on any wall or 0812112D06 cavity that is higher than 10 Engineering calculations have been provided. 08/21/2006 Meets code requirements. 0812'i12006 Building is Type VB, 08/21/2006 All plumbing services ars required to be tested 09/13/2006 and inspected before covering -Water and sewer services are required to have minimum of ten feet of separation. All water piping is required to be tested and 0911312006 inspected before covering. All backflow prevention is required to be installed and tested before final inspection, All drains are required to be bested and 09/13/2006 inspecfed before cowering. Any combination waste and vent systems are required to be approved before installing, All storm water piping is required to he tested 09113,12,0106 and inspected before covering. Provide mechanical plans. Provide energy review for envelope and lighting. CI`T`Y OF a icas Aaipfi�, mmzi! October 24, 2006 Permit, Number: 06 00366 Project Name Project Type: Review Item Review Action American Construction Supply Commercial New Parcel #'s RPRAIRGpO 10060 Actions Required for AWroval. P.O Box 280 18 E. Main St. Rexburg, Idaho $3440 Phone (208) 359-3020 Fax (20$) 359-3022 __ pgroved .:V CITE 0 F EXBURG medw Fal onmivniy October 24, 2006 Review Action Permit Number: 06 00366 Project Name: American Construction Supply Project Type: Commercial New 0 P.0 Box 280 19 E Main St. Rexburg, Idaho 8344 Phone (208) 359-3020 Fax (208) 359-3022 Review ItemActives Requ[red—for-Ap D rova I A raved Fire Department Review Fire Extinguishers Occupancy requires extinguishers. 2A10BC 08/21/2006 minimum required. Alarm Systems Letter of intent required from certified firs alarm 08/21/2006 contractor. Automatic Fire Extinguishing Systems Qualified contractor letter of intent required. 08/21/2006 Building will be sprinklered. Other Comments Lock fox is required for this occupancy. Forms 08/21/2006 are available at the Rexburg Fire Department. Required Fire Flow See site plan review. Water Supply See site plan review. Fire Access Roads See site pian review. Parcel #'s R.PRAIRCP010064