HomeMy WebLinkAboutSOLAR CALCS - 21-00337 - 950 Westwood Dr - Solar PanelsFactor Quantity VA Ungrounded VA Neutral
General lighting load (3va per sq ft) 6 18 18
Small Appliance @1500va each 7 10500 10500
Laundry Circuit @1500va 3 4500 4500
Total General lighting load 15018 15018
Neutral load: First 3000 at 100% 3000
Neutral load:Next at 35% 4206
Net computed Neutral load 7206
Appliances (Nameplate Rating)
Range (or cooktop) 0
Oven 0
Dryer (Nameplate or 5000VA whichever is greater) 0
Well pump (240v)
Water heater (240v)
(240v)
Dishwasher 0
Garbage Disposer 0
Microwave 0
Freezer 0
Exhaust fans 0
Hydro massage tub 0
(120v) 0
(120v) 0
Total Load 15018
First 10,000VA at 100% 10000
Balance at 40% 2007
Subtotal 12007 7206
Other Loads (add largest only)LOAD in VA
A/C or heat pump compressors @ 100%0
Electric Furnace or Thermal storage @ 100% 0
Heat pumps with backup heat strips @ 65% 0
Heating Units (3 or less @ 65%)0
Heating units (4 or more @ 40%)0
Total Volt-Amp 12007.2 7206.3
VA/volts = Amps 50 21
The Division of Building Safety provides the information contained in this calculation sheet for your
convenience only. The figures used in this form are an estimate and provided only to illustrate how to
complete the form. Actual figures are likely to vary. Please ensure the information provided using this
form is accurate and complete. The Division of Building Safety may not be held liable for any incorrect
information submitted with this form.
Optional Load Calculation