HomeMy WebLinkAboutSOLAR CALCS - 21-00337 - 950 Westwood Dr - Solar PanelsFactor Quantity VA Ungrounded VA Neutral General lighting load (3va per sq ft) 6 18 18 Small Appliance @1500va each 7 10500 10500 Laundry Circuit @1500va 3 4500 4500 Total General lighting load 15018 15018 Neutral load: First 3000 at 100% 3000 Neutral load:Next at 35% 4206 Net computed Neutral load 7206 Appliances (Nameplate Rating) Range (or cooktop) 0 Oven 0 Dryer (Nameplate or 5000VA whichever is greater) 0 Well pump (240v) Water heater (240v) (240v) Dishwasher 0 Garbage Disposer 0 Microwave 0 Freezer 0 Exhaust fans 0 Hydro massage tub 0 (120v) 0 (120v) 0 Total Load 15018 First 10,000VA at 100% 10000 Balance at 40% 2007 Subtotal 12007 7206 Other Loads (add largest only)LOAD in VA A/C or heat pump compressors @ 100%0 Electric Furnace or Thermal storage @ 100% 0 Heat pumps with backup heat strips @ 65% 0 Heating Units (3 or less @ 65%)0 Heating units (4 or more @ 40%)0 Total Volt-Amp 12007.2 7206.3 VA/volts = Amps 50 21 The Division of Building Safety provides the information contained in this calculation sheet for your convenience only. The figures used in this form are an estimate and provided only to illustrate how to complete the form. Actual figures are likely to vary. Please ensure the information provided using this form is accurate and complete. The Division of Building Safety may not be held liable for any incorrect information submitted with this form. Optional Load Calculation