HomeMy WebLinkAboutPLANS - 21-00337 - 950 Westwood Dr - Solar PanelsN127'-10"97'-4"
97'-4"127'-10"11'-2"52'-8"10'-10"40'-0"RevGARY PECK RESIDENCE
950 WESTWOOD DR,
REXBURG, ID 83440
PHONE: -(619)921-5738
EMAIL: -gpeck49@aol.com DateDescriptionREVISIONSSignature with SealProject Name &AddressSheet SizeSheet NumberANSI B11" X 17"PV 0.0Sheet NameDRAWN BYAPN: RPR0CHS0020051
237 N 2ND E,
REXBURG, IDAHO, 83440
PHONE: (208) 417-9908
LIC# USES EPCSHEET INDEX:PV 0.0:COVER SHEETPV 1.0:SITE PLANS 1.1:MOUNT DETAILSE 1.1:3-LINE DIAGRAME 1.2:NOTESE 1.3:WARNING LABELS-EQUIPMENT SPEC SHEETCOVER SHEETSCALE: NTS2SATELLITE VIEWPV 0.0SCALE: NTS3VICINITY MAPPV 0.0SCALE: 1/16" = 1'-0"1PLOT PLANPV 0.0GENERAL NOTES:a.INSTALLATION OF SOLAR PHOTOVOLTAICSYSTEM SHALL BE IN ACCORDANCE WITHNEC ARTICLE 690, AND ALL OTHERAPPLICABLE NEC CODES WHERE NOTEDOR EXISTING.b.PROPER ACCESS AND WORKINGCLEARANCE AROUND EXISTING ANDPROPOSED ELECTRICAL EQUIPMENT WILLCOMPLY WITH NEC ARTICLE 110.c.ALL CONDUCTORS, INCLUDING THEGROUNDING ELECTRODE CONDUCTORSHALL BE PROTECTED FROM PHYSICALDAMAGE IN ACCORDANCE WITH NECARTICLE 250.d.THE PV MODULES ARE CONSIDEREDNON-COMBUSTIBLE; THIS SYSTEM ISUTILITY INTERACTIVE PER UL 1741 ANDALSO INCLUDE STORAGE BATTERIES OROTHER ALTERNATIVE STORAGE SOURCES.e.ALL DC WIRES SHALL BE SIZEDACCORDING TO [NEC 690.8]f.DC CONDUCTORS SHALL BE WITHINPROTECTED RACEWAYS IN ACCORDANCEWITH [NEC 690.31]g.ALL SIGNAGE TO BE PLACED INACCORDANCE WITH LOCALJURISDICTIONAL BUILDING CODE.h.PV MODULES TO BE RATED UL 1703 CLASSC FIRE RATING OR BETTER.i.ALL EQUIPMENT TO BE CERTIFIED BY ANATIONALLY RECOGNIZED TESTINGLABORATORY.PROTECTION OF EMERGENCY RESPONDERSALL SHARP EDGES AND FASTENER TIPS SHALL BE COVERED ORCRIMPED OVER TO ELIMINATE SHARP EDGES, TO MINIMIZE RISK OFINJURY TO EMERGENCY RESPONDERS.ALL ROOF MOUNTED CONDUITS, BOXES, AND EQUIPMENTCROSSING PATHWAYS ARE TO BE CLEARLY IDENTIFIED BY ARED/WHITE REFLECTIVE TAPE OR OTHER APPROVED MATERIAL. ROOF ACCESS POINTROOF ACCESS POINT SHALL NOT BE LOCATED INAREAS THAT DO NOT REQUIRE THE PLACEMENTOF GROUND LADDERS OVER OPENINGS SUCH ASWINDOWS OR DOORS, AND LOCATED AT STRONGPOINTS OF BUILDING CONSTRUCTION INLOCATIONS WHERE THE ACCESS POINT DOES NOTCONFLICT WITH OVERHEAD OBSTRUCTIONS SUCHAS TREE LIMBS, WIRES OR SIGNS.PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC ROOF MOUNT SYSTEM10 MODULES-ROOF MOUNTED - 3.200 kW DC, 7.600 kW AC, 950 WESTWOOD DR, REXBURG, ID 83440ROOF ACCESS POINTROOF #1(10) JINKO SOLAR JKM320M-60HBLSLOPE: 18°AZIM.: 270°EXISTING INTERIOR MAIN SERVICEPANEL TIED TO EXTERIOR UTILITYMETER #66 784 495GOVERNING CODESALL WORK SHALL CONFORM TO THE FOLLOWING CODES·2018 INTERNATIONAL BUILDING CODE·2015 INTERNATIONAL RESIDENTIAL CODE·2018 INTERNATIONAL FIRE CODE·2018 INTERNATIONAL MECHANICAL CODE·2019 INTERNATIONAL FUEL GAS CODE·2018 INTERNATIONAL ENERGY CONSERVATION CODE·2017 NATIONAL ELECTRICAL CODE·2018 INTERNATIONAL EXISTING BUILDING CODEMFRONT OF HOUSE
WESTWOOD DR SYSTEM SIZE: 3.200 kW DC7.600 kW ACMODULE TYPE & AMOUNT:(10) JINKO SOLAR JKM320M-60HBLMODULE DIMENSIONS:(L/W/H) 66.3"/39.45"/1.38"INVERTER:(01) GENERAC PWRCELL X7602BATTERY CAPACITY: 9.0 kWHBATTERY:(01) GENERAC PWRCELL 9 (BJ-DCB05ZKBG, IR3DCB)INTERCONNECTION METHOD: LOAD BREAKERPROPERTY LINE PROPERTY LINEPROPERTY LINEPROPERTY LINEMAIN HOUSEDRIVEWAYGARAGE FENCE
N3'-0"16'-9"30'-3"NEW PV ATTACHMENTAT 4'-0" O.C.RevGARY PECK RESIDENCE
950 WESTWOOD DR,
REXBURG, ID 83440
PHONE: -(619)921-5738
EMAIL: -gpeck49@aol.com DateDescriptionREVISIONSSignature with SealProject Name &AddressSheet SizeSheet NumberANSI B11" X 17"PV 1.0Sheet NameDRAWN BYAPN: RPR0CHS0020051
237 N 2ND E,
REXBURG, IDAHO, 83440
PHONE: (208) 417-9908
LIC# USES EPCEQUIPMENTLAYOUT SITEPLANSCALE:1/8" = 1'-0"1SITE PLANPV 1.0ROOF SECTION(S)MODULE - 10SLOPE - 18°AZIMUTH - 270°MATERIAL - COMPOSITION SHINGLETRUSS SIZE & SPACING - 2"X4" @ 24" O.C.ROOF #01MODULE, ARRAY WEIGHT (LOAD CALC'S)Number of Modules10Module Weight41.9LBSTotal Module (Array) Weight419.00LBSNumber of Attachment point32Mounting System Weight(Per Module)1.5LBSMounting System Weight48.00LBSTotal System Weight(Module Weight + Mounting System Weight)467.00LBSWeight at Each Attachment Point(Array Weight / Number of Attachment Point)13.09LBSModule Area (66.3"x39.45")18.16SqFtTotal Array Area181.63SqFtDistributed Load(Total System Weight / Total Array Area)2.39Per SqFtTotal Roof Area2560SqFtTotal Percentage or Roof CoveredTotal Array Area / Total Roof Area)*1007.10%SYSTEM SIZE: 3.200 kW DC7.600 kW ACMODULE TYPE & AMOUNT:(10) JINKO SOLAR JKM320M-60HBLMODULE DIMENSIONS:(L/W/H) 66.3"/39.45"/1.38"INVERTER:(01) GENERAC PWRCELL X7602BATTERY CAPACITY: 9.0 kWHBATTERY:(01) GENERAC PWRCELL 9 (BJ-DCB05ZKBG, IR3DCB)PHOTOVOLTAIC SYSTEM SPECIFICATIONS:36" FIRE SETBACK36" FIRE SETBACKMACIBCLNEW PV AC DISCONNECT GROUPED WITH SERVICEEQUIPMENT (VISIBLE, LOCKABLE, LABELED)EXISTING INTERIOR MAIN SERVICE PANEL& POINT OF INTERCONNECTION. TIED TOEXTERIOR UTILITY METER #66 784 495NEW GENERAC PWRCELL X7602 INVERTER(01) NEW GENERAC PWRCELL 9(BJ-DCB05ZKBG, IR3DCB)NEW CRITICAL BACKUP LOAD PANELPVLPVLFRONT OF HOUSE
WESTWOOD DRROOF #01STRING #2 - 05 MODULESSTRING #1 - 05 MODULESSTRING(S)SYSTEM LEGENDMAC10 NEW JINKO SOLAR JKM320M-60HBLMODULES WITH GENERAC SNAP RS INLINEDISCONNECT SWITCHNEW 01 - GENERAC PWRCELL X7602 INVERTERI= CONDUIT EXTERIOR RUN= ROOF OBSTRUCTIONS= FIRE PATHWAYNEW VISIBLE, LOCKABLE, LABELED DISCONNECTLOCATED WITHIN 10' FROM THE UTILITY METERNEW GENERAC S2502 PV-LINK SUB STRINGOPTIMIERS.PVLNEW CRITICAL BACKUP LOAD PANELCLGENERAC PWRCELL 9 (BJ-DCB05ZKBG, IR3DCB)ENERGY STORAGEB= ATTACHMENT POINTS= RAFTER= RACKING SYSTEMNOTE: MARKING FOR ESS DISCONNECTSHOWN IN COMPLIANCE WITH NEC 706.7 (D)DISCONNECTS (PLACED NEXT TO THE ESS)ARE REQUIRED WHEN ESS IS 5FT + ORSEPERATED BY A PARTITION WALL FROMTHE INVERTER (NEC 706.7 (E)EXISTING INTERIOR MAIN SERVICE PANEL & POINTOF INTERCONNECTION. TIED TO EXTERIOR UTILITYMETER #66 784 495.
RevGARY PECK RESIDENCE
950 WESTWOOD DR,
REXBURG, ID 83440
PHONE: -(619)921-5738
EMAIL: -gpeck49@aol.com DateDescriptionREVISIONSSignature with SealProject Name &AddressSheet SizeSheet NumberANSI B11" X 17"S 1.1Sheet NameDRAWN BYAPN: RPR0CHS0020051
237 N 2ND E,
REXBURG, IDAHO, 83440
PHONE: (208) 417-9908
LIC# USES EPCMOUNT DETAILSCALE: NTS2ATTACHMENT DETAIL ENLARGED VIEWS 1.1SCALE: NTS1ATTACHMENT DETAIL (SIDE VIEW)S 1.1GENERAL STRUCTURAL NOTES:1.THE SOLAR PANELS ARE TO BE MOUNTED TO THEROOF FRAMING USING THE IRONRIDGE RACKINGSYSTEM WITH FLASH FOOT 2 ATTACHMENTS. THEMOUNTING FEET ARE TO BE SPACED AS SHOWNIN THE DETAILS, AND MUST BE STAGGERED TOADJACENT FRAMING MEMBERS TO SPREAD OUTTHE ADDITIONAL LOAD.2.UNLESS NOTED OTHERWISE, MOUNTINGANCHORS SHALL BE 5/16" LAG SCREWS WITH AMINIMUM OF 2-1/2" PENETRATION INTO ROOFFRAMING.3.THE PROPOSED PV SYSTEM ADDS 2.6 PSF TO THEROOF FRAMING SYSTEM.4.ROOF LIVE LOAD = 20 PSF TYPICAL, 0 PSF UNDERNEW PV SYSTEM.5.GROUND SNOW LOAD = 0 PSF6.WIND SPEED = 115 MPH7.EXPOSURE CATEGORY = 08.RISK CATEGORY = IIPV MODULE(E) COMP SHINGLE ROOFIRONRIDGE INTEGRATEDGROUNDING & END/MID CLAMPPV MODULESIRONRIDGE XR-10 RAILFLASHING2"X4" TRUSS @ 24" OC5/16"x3" SS LAG BOLT WITH MIN2-1/2" THREAD EMBEDMENT,SEALED PENETRATIONSEE (2/S 1.1) FORENLARGED VIEWIRONRIDGE FLASH FOOT 22"X4" TRUSS @ 24" OC
RevGARY PECK RESIDENCE
950 WESTWOOD DR,
REXBURG, ID 83440
PHONE: -(619)921-5738
EMAIL: -gpeck49@aol.com DateDescriptionREVISIONSSignature with SealProject Name &AddressSheet SizeSheet NumberANSI B11" X 17"E 1.1Sheet NameDRAWN BYAPN: RPR0CHS0020051
237 N 2ND E,
REXBURG, IDAHO, 83440
PHONE: (208) 417-9908
LIC# USES EPC3-LINEDIAGRAMNOTE: -#6 AWG SOLID CU EQUIPMENT GROUNDCONDUCTOR CONT. RUN TO GROUND LUG ONRACKING SYSTEM. ALL ROOFTOP COMPONENTSBONDED TO RACKING SYSTEM PER NEC 690.43NOTE: -1.PV WIRE - GREEN SPEC, UL SUBJECT 4703,UL 44, UL 854, 200V, 90C-RoHS2.JUNCTION BOX - SOLADECK (0799-5), UL 50,CSA C22.2 NO # 290, NEMA TYPE 3R, UL1741PV MODULE RATING @ STCMANUFACTURERMAX. POWER-POINT CURRENT (IMP)MAX. POWER-POINT VOLTAGE (VMP)OPEN-CIRCUIT VOLTAGE (VOC)SHORT-CIRCUIT CURRENT (ISC)9.59 AMPSJINKO SOLAR JKM320M-60HBL33.4 VOLTS40.9 VOLTS10.15 AMPSNOM. MAX. POWER AT STC (PMAX)MAX. SYSTEM VOLTAGEVOC TEMPERATURE COEFFICIENT320 WATT1000V-0.28 %/°CRooftop conductor ampacities designed in compliance withart. 690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a),310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9.Location specific temperature obtained from ASHRAE 2017data tablesAMBIENT TEMP (HIGH TEMP 2%)RECORD LOW TEMP-18C32°CCONDUIT HEIGHT0.5"ROOF TOP TEMPINVERTER CHARACTERISTICS - GENERAC PWRCELL X7602MAX OUTPUT POWER7600WSYSTEM OPERATING VOLTAGE380VMAX CONTINOUS OUTPUT CURRENT32AMAX INPUT VOLTAGE420VMAX INPUT CURRENT20AMAX EFFICIENCY97%PHOTOVOLTAIC SYSTEMDC SYSTEM SIZE (WATTS)NOMINAL AC VOLTAGE240V3200WAC SYSTEM SIZE (WATTS)7600WTOTAL NUMBER OF MODULES10CONDUCTOR TEMPERATURE RATE90°C54°CWIREQTYWIRETAG #CONDUITWIRE TYPESTRINGWATTAGEOPERATINGVOLTAGECONDUITFILL:TEMPRATING:WIREAMPTEMPDE-RATE:WIREOCP:MAX SYSTEMVOLTAGEGRNDSIZEWIREGAUGE:TERMINAL75°C RATING:NEC:MAXAMPSxx=/x=1.25240V1600W8.33A38.40A35A90°35A/x=1.25240V3200W16.67Axx=30.40A90°50A/x=1.2540.00Axx=47.00A75°40A#1040A#1050A#83/4" EMT3/4" EMTWIRE FROM - -PV LINKTOINVERTERINVERTER TO ACDISCONNECTARRAY TO PVLINK123PV WIRETHWN-2THWN-24N/A21.0031.00IN AIR/====STRINGAMPS6.67A13.33A32.0AxGRND WIRETYPE420V420V240V#6#8#8SBCTHWN-2THWN-20.960.760.9421352135++--++--+++-+-+-+-+-+---GENERACPOWERCORERSRSRSRSRSRSGENERACGENERAC30A30AROUTERGENERACGENERACGENERACGENERACGENERACGENERACGENERAC S2502 PV LINKSUB STRING OPTIMIZER,UL1741 CERTIFIED, NEC690.12 COMPLAINTGENERAC SNAP RSINLINE DISCONNECTSWITCH, UL1741CERTIFIED, NEC690.12 COMPLIANTGENERAC PWRCELL X7602 INVERTEROUTPUT: 240VAC, 32.0A96.5% CEC WEIGHTED EFFICIENCYNEMA 3R, UL1741 SA LISTED, INTERNAL GFDIWITH INTEGRATED DC DISCONNECT(01) GENERAC PWRCELL 9(BJ-DCB05ZKBG, IR3DCB) BATTERYUL9540, UL1973, UL1642 CERTIFIED21EXTERNAL SAFETY RAPIDSHUTDOWN TERMINAL50A(2) #8 AWG THWN-2(1) #8 AWG GND3/4" EMT CONDUITN(N) 120/240V, 200ACRITICAL BACKUP LOADPANEL, SINGLE PHASEUL1741 CERTIFIEDG(E) LOADS(E) LOADS(3) #6 AWG THWN-2(1) #8 AWG GND1" EMT CONDUIT(N) PV BREAKERNEC 705.12(B)(2)(3)(d)GNMPOINT OF INTERCONNECT, LOAD SIDENEC 705.12(B)(2)(3)(d)EXISTING 240V/150A BUS BAR RATING, MAINSERVICE PANEL, SINGLE PHASE, WITH A NEW125A MAIN DISCONNECTUTILITY COMPANY: PACIFIC POWERUTILITY METER: 66 784 49540AMODULE:(10) JINKO SOLAR JKM320M-60HBLINVERTER:(01) GENERAC PWRCELL X760210 NEW JINKO SOLAR JKM320M-60HBLMODULES WITH GENERAC SNAP RS INLINEDISCONNECT SWITCH30A30A(N) 30A BATTERYDISCONNECT, 240VUL1741 CERTIFIED30APV MODULE FRAMEIRONRIDGE RAILIRONRIDGE UNIVERSALFASTENING OBJECTIRONRIDGE GROUNDING PIERCESTHROUGH ANODIZED COATINGSOF MODULE FRAMES AND RAILSIRONRIDGE GROUNDING PIERCESTHROUGH ANODIZED COATINGSOF MODULE FRAMES AND RAILSIRONRIDGE INTEGRATED GROUNDING & LAY-IN LUGS ARE UL2703 LISTEDGROUNDING DETAILscale: NTSSS SET SCREW INCLUDED#10-24 X 3/4" SS HCS BOLT#10 SS EXTERNAL TOOTHLOCK (STAR) WASHER#10-24 SS LOCK NUT6 AWG BARE CU WIRELAY-IN LUG TERMINALAL/CU DUAL RATED(TIN PLATED CU)IRONRIDGE RAILRAILSMODULES(N) 125A(E) LOADSNOTE: -ESS DISCONNECT SHOWN ON THIS SHEETIS IN COMPLIANCE WITH NEC 706.7(D)120% RULEBUS BAR RATING X 120%) - MAIN BREAKER RATING=MAX. PV OCPD(150A x 120%) - 125A = 55A2 STRINGS OF 5 PV MODULES CONNECTED IN SERIESNOTE: -MAIN BREAKER DERATED FROM150A TO 125A IN ACCORDANCEWITH NEC 705.12(B)(2)(3)(b)(N) JUNCTION BOXUL1741 CERTIFIEDGENERAC S2502 PV LINKSUB STRING OPTIMIZER,UL1741 CERTIFIED, NEC690.12 COMPLAINTGENERAC APKE00032 PWRCELL2 CT ACCESSORY KITRAPID SHUTDOWNSWITCH TO BE PLACEDIN CONSPICUOUSLOCATION ONEXTERIORNOTE: -SINGLE LARGEST LOAD IN BACKEDUP LOAD PANEL CANNOT EXCEEDTHE ESS STORAGE CAPACITYCONTINUOUS RATING (18.75A) ANDSURGE OF (25A AC) FOR 2SECONDS PER NEC 710.15(E)GROUNDMIN 8'MIN 6'5' MAX#6 AWGBAREARMOUREDCABLECOLD WATERBONDNOTE: -THE POINT OF CONNECTION IS NOTADJACENT TO FEED THRU LUGS &CONDUCTORS AND IS INCOMLIANCE WITH NEC 705.12NOTE: -1.AS PER THE 314.16(A) SOLADECK JUNCTION BOX SIZE SHOULD BE 3" X 2" X 2".2.300.15(F) FITTING. A FITTING IDENTIFIED FOR THE USE SHALL BE PERMITTED IN LIEUOF A BOX OR CONDUIT BODY WHERE CONDUCTORS ARE NOT SPLICED ORTERMINATED WITHIN THE FITTING. THE FITTING SHALL BE ACCESSIBLE AFTERINSTALLATION, UNLESS LISTED FOR CONCEALED INSTALLATION.3.FROM FREE AIR WIRING METHODS TRANSITIONING TO A RACEWAY WIRING METHODSHALL COMPLY WITH NEC 300.15, 300.17, 314.16 AND 69.43 AS APPLICABLE33GN(N) BLADE TYPENON-FUSIBLE AC DISCONNECTNEMA 3R 60A-2P 120/240VAC(VISIBLE, LOCKABLE, LABELED)UL1741 CERTIFIED
RevGARY PECK RESIDENCE
950 WESTWOOD DR,
REXBURG, ID 83440
PHONE: -(619)921-5738
EMAIL: -gpeck49@aol.com DateDescriptionREVISIONSSignature with SealProject Name &AddressSheet SizeSheet NumberANSI B11" X 17"E 1.2Sheet NameDRAWN BYAPN: RPR0CHS0020051
237 N 2ND E,
REXBURG, IDAHO, 83440
PHONE: (208) 417-9908
LIC# USES EPCNOTES SITE NOTES:1.A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHAREGULATIONS.2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AUTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.3.THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL,OR BUILDING ROOF VENTS.4.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSEDELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26.5.ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED INACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'SINSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THEBUILDING OR STRUCTURE.EQUIPMENT LOCATIONS:1.ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26.2.WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTEDOPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES310.15 (B)(2)(A) AND 310.15 (B)(3)(C).3.JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULESACCORDING TO NEC 690.34.4.ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOTWITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.6 ALL EQUIPMENT SHALL BEINSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NECAPPLICABLE CODES.5.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOORUSAGE WHEN APPROPRIATE.STRUCTURAL NOTES:1.RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TOCODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATEDSPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCEBEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIMANUFACTURER’S INSTRUCTIONS.2.JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IFROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCALREQUIREMENTS.3.ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR.4.ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THESPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHENPOSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGEREDAMONGST THE ROOF FRAMING MEMBERS.WIRING & CONDUIT NOTES:1.ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODEREQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING.2.CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7.3.VOLTAGE DROP LIMITED TO 1.5%.4.DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRINGSYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLEWIRING CLIPS.5.AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACKPHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3-BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREYIN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TOBE MARKED ORANGE [NEC 110.15].GROUNDING NOTES:1.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, ANDGROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCHUSE.2.PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUMNEC TABLE 250.122.3.METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURESCONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A).4.EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC690.45 AND MICROINVERTER MANUFACTORERS’ INSTRUCTIONS.5.EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN INMANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARENOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIEDGROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATIONREQUIREMENTS.6.THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THATTHE REMOVAL OFA MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TOANOTHER MODULE.7.GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOREDGREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119]8.THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, AGROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47AND AHJ.9.GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TOREDUCE FIRE HAZARDSDISCONNECTION AND OVER-CURRENT PROTECTION NOTES:1.DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH ISOPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THETERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS).2.DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BELOCKABLE, AND BE A VISIBLE-BREAK SWITCH3.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPIDSHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCYRESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D).4.ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND240.5.MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPEDFUSES IN ACCORDANCE WITH NEC 110.3(B).6.IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTIONACCORDING TO NEC 690.11 AND UL1699B.INTERCONNECTION NOTES:1.LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC 705.12 (B)]2.THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOTEXCEED 120% OF BUSBAR RATING [NEC 705.12(D)(2)(3)].3.THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENTAND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALLNOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATEDBACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THEUTILITY SOURCE OCPD [NEC 705.12(B)(2)(3)].4.AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTALRATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OFBUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDEDACCORDING TO NEC 705.12 (B)(2)(3)(C).5.FEEDER TAP INTERCONECTION (LOADSIDE) ACCORDING TO NEC 705.12 (B)(2)(1)6.SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITHSERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.422.7.8BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPTFROM ADDITIONAL FASTENING [NEC 705.12 (B)(5)].
NRevGARY PECK RESIDENCE
950 WESTWOOD DR,
REXBURG, ID 83440
PHONE: -(619)921-5738
EMAIL: -gpeck49@aol.com DateDescriptionREVISIONSSignature with SealProject Name &AddressSheet SizeSheet NumberANSI B11" X 17"E 1.3Sheet NameDRAWN BYAPN: RPR0CHS0020051
237 N 2ND E,
REXBURG, IDAHO, 83440
PHONE: (208) 417-9908
LIC# USES EPCWARNINGLABELSCAUTION:POWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN(10) PV MODULESMACINVERTERJ/BPV ARRAYPER CODE(S): NEC 2011: 705.12(B)(2)(3)(b), NEC 2017WARNING!DO NOT RELOCATE THISOVERCURRENT DEVICEINVERTER OUTPUT CONNECTION!WARNING: PHOTOVOLTAICPOWER SOURCE(PER CODE: NEC 690.31(G)(3)(4) & NEC 690.13(G)(4))PER CODE(S): NEC 2017: 690.13(B)ELECTRICAL SHOCK HAZARDDO NOT TOUCH TERMINALS.TERMINALS ON LINE AND LOADSIDES MAY BE ENERGIZED INTHE OPEN POSITIONWARNING!!PHOTOVOLTAICAC DISCONNECT(PER CODE: NEC 690.14 (C) (1))SOLAR PHOTOVOLTAICSYSTEMS(PER CODE: NEC 690)LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 32.0 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSINVERTER #1 (GENERAC PWRCELL X7602)PHOTOVOLTAIC SYSTEMEQUIPPED WITHRAPID SHUTDOWNLABEL LOCATION:UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECTIF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS ASREQUIRED BY LOCAL AHJ.PER CODE(S): NEC 2011: ARTICLE 690.56(C): NEC 2017SOLAR PHOTOVOLTAICSYSTEMS(PER CODE: NEC 690)SOLAR PHOTOVOLTAICSYSTEMS(PER CODE: NEC 690)PHOTOVOLTAIC DC DISCONNECTMAXIMUM SYSTEM VOLTAGE:MAXIMUM CIRCUIT CURRENT:MAX RATED OUTPUT CURRENT OF THE CHARGECONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED):VDCADCADC4208.415INVERTER #1 (GENERAC PWRCELL X7602)LABEL LOCATION:INVERTER(S), DC DISCONNECT(S).PER CODE(S): CEC 2016: 690.53, NEC 2017: 690.53, NEC 2014: 690.53,NEC 2011: 690.53ASOLAR PV SYSTEMEQUIPPED WITH RAPIDSHUTDOWNTURN RAPIDSHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUTDOWN PVSYSTEM ANDREDUCESHOCK HAZARDIN THE ARRAYSOLARELECTRICPV PANELSAT INVERTER [IFC 605.11.3.1(1) & 690.56(C)(1)(a)]PER CODE: NEC 2017INVERTERCRITICAL BACKUPLOAD PANELMAIN SERVICE PANELUTILITY METERBATTERYAC DISCONNECTWESTWOOD DR MACIBCL