Loading...
HomeMy WebLinkAboutRESCHECK - 06-00335 - 234 Seagull Dr - New SFR...o 0600335 234 Seagull -Olympus Bldg REScheck Compliance Certificate 2003 IECC REScheck Software Version 3.6 Release 2 Data filename: CAProgram Files\Check\REScheck\olympus\EliPena rck PROJECT TITLE: Pena Residence CITY: Iddm Ftls RCv vd STATE: Idaho HDD: 7918 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.13 DATE: 07/24/06 DATE OF PLANS: May 2005 PROJECT DESCRIPTION: Eli Pena New Home DESIGNER/CONTRACTOR: Olympus Builders COMPLIANCE: Passes Maximum UA = 328 Your Home UA = 288 12.2% Better Than Code (UA) Checked By/Date EGEod� Ldill 2 5 2 CITY OF RExauRG Gross Glating Area or Cavity Cont. or Door Eerimet B-Value R-Value U-Factor 3!A Ceiling 1: Flat Ceiling or Scissor Truss 1467 0.0 38.0 37 Wall l: Wood Frame, 24" o .c. 1767 23.0 0.0 81 Window 1: Vinyl Frame:Double Pane with Low-E 183 0.350 64 Door 1: Solid 60 0.350 21 Basement Wall 1: Solid Concrete or Masonry 1324 19.0 0.0 62 Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' Window 2: Vinyl Frame:Double Pane with Low-E 64 0.350 22 Floor 1: All -Wood Joist/Tmss:Over Outside Air 54 38.0 0.0 1 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Date REScheck Inspection Checklist 2003 IECC REScha* So$ware Version 3.6 Release 2 DATE: 07/24/06 PROJECT TITLE: Pena Residence Bldg. Dept. Use Ceilings: [ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-38.0 continuous insulation Comments: Above -Grade Walls: [ ] I 1. Wall 1: Wood Frame, 24" o . c., R-23.0 cavity insulation Comments: Basement Walls: [ ] I 1. Basement Wall 1: Solid Concrete or Masonry, 8.0' ht/6.0' bg/8.0' insul, R-19.0 cavity insulation I Comments: Windows: [ ] I 1. Window 1: Vinyl Fnune:Double Pane with Low E, U-factor. 0.350 For windows without labeled U fictors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] I 2. Window 2: Vinyl Frame:Double Pane with Low E, U-factor. 0.350 For windows without labeled U-factors, describe Eatures: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] I 1. Door 1: Solid; U-factor. 0.350 Comments: Floors: [ ] I 1. Floor 1: All Wood Joist/Truss:Over Outside Air, R-38.0 cavity insulation Comments: Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources ofair leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. I I Skylights: Minimum insulation requirement fir skylight shafts equal to or greater than 12 inches is R-19. Vapor Retarder: Required on the warm -in -winter side *of all non vented framed ceilings, walls, and floors. Materials Identification.: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: Supply ducts in unconditioned attics or outside the building must be insulated to R-11. Return ducts in unconditioned attics or outside the building must be insulated to R-6. Supply ducts in unconditioned spaces must be insulated to R-11. Return ducts in unconditioned spaces (except basements) must be insulated to R-2. Where exterior walls are used as plenums, the wall must be insulated to R-11. Insulation is not required on return ducts in basements. Duct Construction: Duct connections to flanges ofair distribution system equipment must be sealed and mechanically fastened. All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Thermostats are required fDr each separate HVAC system. A manual or automatic means to partially restrict or shut offthe heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water systems: Tnsulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools must have an on/offheater switch and require a cover unless over 20% ofthe heating energy is from non-depletable 'sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pine, Sizes, Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature l Fl U to 0 1" Utz to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipe.. Ping System T Fluid Temp. l F) Insulation Thickness in Inches by Pipe Sizes 2" 2,511to 4" 2" Runouts 1" Less 1.25" to Heating Systems gg and Low Pressure/Temperatur, 201-250 1.0 1.5 1.5 2.0 Low Temperature 106-200 0.5 1.0 1.0 1.5 Steam Condensate (fir Lad water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) 0600335 234 Seagull Dr REScheck Compliance Certificate Checked By/Date 2003 IECC REScheck Software Version 3.6 Release 2 Data filename: C:\Progmm Files\Check\REScheck\olympus\EliPena#2.rck CITY: Idaho Falls STATE: Idaho HDD: 7918 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.10 DATE: 06/06/06 COMPLIANCE: Passes Maximum UA = 324 Your Home UA = 324 0.0% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or Door Perimet -Value -V ue U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 1467 -' 0.0 40.0. 35 Wall 1: Wood Frame, 24" o .c. 1811O 1767 --' 23.0 , 0.0 82 Window]: Vinyl Frame:Double Pane with Low-E 183 68 .55 92 Door l: Solid 60 0.350 21 Basement Wall 1: Solid Concrete or Masonry 41 1324 11.0 0.0 93 Wall height: grad Y? fo Depth below grade: 6.0' Insulation depth: 8.0' Floor 1: All -Wood Joist/Tmss:Over Outside Air 54 38.0 0.0 1 f;u rV,&(<o 7 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer REScheck Inspection Checklist 2003 IECC REScheck Sofware Version 3.6 Release 2 DATE: 06/06/06 Bldg. I Dept. j Use Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-40.0 continuous insulation Comments: I Above -Grade Walls: [ ] I 1. Wall 1: Wood Frame, 24" o .c., R 23.0 cavity insulation Comments: I j Basement Walls: [ ] I 1. Basement Wall 1: Solid Concrete or Masonry, 8.0' ht/6.0' bg/8.0' insul, I R-11.0 cavity insulation Comments: I Windows: [ ] I 1. Window 1: Vinyl Frame:Double Pane with Low E, U-fictor. 0.550 j For windows without labeled U-motors, describe fatures: # Panes Frazee Type Thermal Break? [ ] Yes [ ] No Comments: 1 I Doors: [ ] I 1. Door l: Solid, U-ktor. 0.350 I Comments: I I Floors: [ ] I 1. Floor 1: All Wood Joist/Truss:Over Outside Air, R-38.0 cavity insulation I Comments: Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources ofair leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non IC rated, the fixture must be installed with a 3" clearance from insulation. Skylights: Minimum insulation requirement fDr skylight shags equal to or greater than 12 inches is R-19. Vapor Retarder: [ ] I Required on the warm4n-winter side ofall non vented framed ceilings, walls, and floors. I Materials Identification: [ ] ( Materials and equipment must be installed in accordance with the manufacturer's installation instructions [ ] ( Materials and equipment must be identified so that compliance can be determined. [ ] I Manufacturer manuals fir all installed heating and cooling equipment and service water heating equipment must be provided. [ J ( Insulation R values and glazing U-factors must be clearly marked on the building plans or specifications. I Duct Insulation: [ ] ( Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] ( Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] ( Supply ducts in unconditioned spaces must be insulated to R-11. ] I Return ducts in unconditioned spaces (except basements) must be insulated to R-2. ] ( Where exterior walls are used as plenums, the wall must be insulated to R-11. ( Insulation is not required on return ducts in basements. ( Duct Construction: [ ] ( Duct connections to flanges ofair distribution system equipment must be sealed and mechanically fastened. [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), ( mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. ( Exertion: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w. g. (500 Pa). [ ] ( The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] ( Thermostats are required for each separate HVAC system. A manual or automatic means to ( partially restrict or shut offthe heating and/or cooling input to each zone or floor shall be provided. ( Service Water Heating: [ ] ( Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Circulating Hot Water Systems: [ ] I insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% ofthe heating energy is from non-depletable sources. Pool pumps require a time clock. I Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the I levels in Table 2. *sap/ Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by pie Sizeq Heated Water Non-Circulating_Runouts Circulating Mains and Runous Temperature ( F) -Up to V Up to 1.25" 1.5" to 2.0" Over 21, 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. FIuid Temp. Insulation Thickness injnches by PjM Sixes Piping System Types Range ( F) 2" Runouts 1" and Less 1.25" to 2" " t " Heating Systems Low Pressure/Temperature 201 250 _ 1.0 1.5 1.5 2.0 Low Temperature 106-200 0.5 1.0 1.0 1.5 Steam Condensate (for ked water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)