FRAMING/MECH. CHECKLIST
Date:
Project' M aw,�
Job Address:
"O
Building Permit Number-
--
;.j
iivvvi1l�. �;�dr�rr�enrs aasea on the ��Q3 edit on of the Intemational Residential Cp�de'should be
resolvedbefore an occupancy- perm -lit is issued, This,correction dist is not a wilding permit. Th'a ravai
ofplans and specificatiQns dnP__q n�,t �,pr�,if +�,� �.,.��„+:..w ..� _.�- - - - -t. � ., �`p
Tho
- - -- ...,r•..L �� .r«,iauut � u1 d�lj/ SECiiOn ��' vie 1�7t8�'f77�IOt7P1 RP__4zirhnn�;qi
e Ur any federal, state or local regulations.
Exterior
/oncrete Slabs (3 1/2 "min. thickness & 4"gravel base min.) R506.1
Braced Wall Panels (sheathing)(na irl or staple - Ut o. c. at edges & 12" o. c in fiairll Tnl,io ani �of�
1 j
p+�iec�u�'a uplift control at floor line (sheathing.- split an plate or 1 Y2X 36" straps 4' c�. c. mudsil� to studs
i
Seismic hold-rJmA
ins at garage panels <4' ��ide MAPA narrow panel design if X2'8"), hold-downs must be on
d o u Ne stud or 3X with all haft hole's fi I led - R602w 10.4
Foundation Waterproofing to finish radeR40S.'I
_Crawl space ventilation Isf per 150sf (wl vapor barrier IsUper 1500so within 3' of corner R408--1-2
r
C r
ipple Walls (over 4' sized as 2 story, under '14" mush be s
olid ly sheathed one side) R602.9
MUcf Sill (bolts in proper location, nuts tightened, x2"x3/16'° washers (conditionalpressurered�nrood, points blocked or under studs at wallandgaps grouted or shimmed �4Q� ��s,�`treated yr
Fra e - � R6021 1.1
Floor Sheathing and nailing Typ. 3/41' T&G - 6" on edges & 12"Jn field (perpendicular to jo
OF
Ist
C,joist Spacing and .Size has per plans) Ir
Bearing {7 -'lid" min:} & Laing�Pp(3" min. where joists jap over wall or beam)
Notching (4eP-th-1/6 max. , lenqth-'l13 depth max., not in middle 113, ends- 114 dmax_} ,TJ1 Na
/Boring (113 "d„ max, }2" of top or bottom or another hole or notch) CJI see chart
antilevers- Blocki reinfarcernen#, soman ands acro as per plans.
Joists Under oad Barin Partitions (shall be doubled as per Section 502.3.3, if plumbing space needed,
the joists sCiall ue crocked )
�arders and Beams has per plans, nailed or mechanically connected to frame and proper bearing)
Joist Handers (check location & nailed properly)
Draft Stop (required for over 100:0 sq ft. of unusable space at floor/ce'lling)
Basement Walls (pressure treated or redwood sill plate properly fastened to slab}
�Stair Opening has per pian & properly supported with hangers or walls) .
Stairs {check rise- 7 314" max., run- 10" min., vari.- 3/811 max, width -3' min. & headroom- 6-8")
,4Wall Layout (as per plans)
Interior Wall Stud. Spacing (load bearing is same as exterior), 24" o.c. max.
Bearing Wali Window and Door Headers Nailinghedge lends)
Exte��or Bearing
At ii Stud S�acing - walls carrying roof load only; 2x4-16" a.c. 12'max
2x4-24" O.C. 10' max,- 2x6-16" o.c. 18' max- 2x6-24" a.c.
, r roof-- 2x4 1611 O.C.
16' rax, �., -
I O'max., two floors & rOO 2x4-12" max 10' (Fig 602.3.2.(1-3))
T..., o��+o Gnintc lannad mirr: 2'1 or Single Top Plate (bearing w/fn 1 ° &adequately tied at joints by
Vu:,.i%.71C.r 1 Vl.J 1 IG3L�rmin..
� -
3"x6" steel plates wl +6 Sd on nails each side} Rfi02.3.2
Stud Notchin (bearing 25% max_} Barin 40% max, 5/8 11 (60%min. to edges if doubled)
,Fire Blocking (roof space fine of wall, concealed spaces &.at studs over 10')
n duplexes &garage/home) , firewail penetrations - elec. boxes- ruedductsFirewalls (b��wee
26 gauge & not open to garage, door !20 minute raked min.
Roof
Truss details
(35# snow load and 90 mph winds) See truss- deta'JIS
Roof Trusses (spacedand braced as
r manufacturer)
after and Truss ie-Down an , a_ _nc..ers
afters Lateral- Support block at b
caring when exceeding 5 to 'l rude (2xl 2)
R
d
Roof Sheathing: Nailing ("H') cl i ps wI 7/16")) edges-6" o.c., field - 12 it O.C.
moo ccess(provide 22" x 30"min. access where c{ear height > 3p")
Attic A�
I
/Roof Ventilation (standard
1/150 or 1/300 if 50 - 80% is 3' above eaves)
ENEEMM40
r
chanical (Rough Plu bing Insp. Done? �
Manufacturer's installation instructions are with the appliance (IRC 106.Im2/M130741)
Equipmenf g2Sshutoff values in same room AFP exception} and within 6' at appliance (IFGC 409-5)
Qodim4nt Trapift (if not built �r�tu apN1���ic;�) at rurnaCe BSc W.H. (IFGC 4{38.41
�• � `
Duct Supports an
sealed etal - c I p' spacing & Flexible - < 4' max - (2if sag in 4')
ZClothes Dryer Ducts (solid metal ducts, no screws extending into duct
� insulation /Duct �insulati�on in non-condi��oned Space)
venirectly to outside)
oom access 24" min wa�th 1 Attic acce.Z
ss clear opening 20x3O min (Under floor is 22x3O)(IMC SOS)
Pressure Regulators (access, vented, fee fitting each side) (IFGC 410)
Metallic gas pipe bends are smooth & free from duckling, creeks, or other damage (IFGC 4Q5.2)
/0 t
Pressure. Test:
I__P si.—Wrnin�. duration ib pressure drop
Gas Pipe Material: ASST Sch40 MP Capper Main Line ft diameter
Branch Lines: Length ft To POD Diameter Appliance/BTU's (if knownft)
ft ft"`-
ft ft
ft ft
ft ftft -
�ft �t
f
IM
I
ig
Residential Rough -in
Permit
Inspector
Dade Inst
ElucLrical licenses current, apprentice to journeyman raffia.
—'
Grounding System complete.
Service complete.
Any subpanels through out the house.
� Circuits feeding the right �h�ngs such. as furnaces, water heaters.
� Water heater.
Fumace,i unit.,,
1�����z�u oasem.en,�, outlet and liL:)7hfis: Smoke defector tied to the rest of tie house.
�`
Wires. all terminated in boxes. ete.
—' Holes drilled in the m;rlrlla n4'r1,A qr„A,n ..,..._�
wuiv v.L L114+ JLLAll 3 Vi Lk u1Q.�.riU.
_K Garage wired correctly with outlets and lights on the interior and exterior.
� Kitchen vvired with the right outlet location and lighting.
Living room has outlet spacing correct and fl.00r plug if required
-t&-, Bedrooms oate circuits. Are the outlets where there needs to be, 2 font rule.
Smoke detectors in proper places and tied tageiher.
Romex strapped up correctly through out the who house.
Low voltage cables strapped up.
Lighting an the exterior at every door.
_
Outlets ars the exterior (2).
as line bonded as well as water line.
-\IjntPq