HomeMy WebLinkAboutHEATING CALCS - 06-00293 - 3912 W 2250 N - New SFR MechanicalNove
mber 7 2006
City of Rexburg,
X91? N nty MecIZ
%.I
Heating calculation for Jeremy Rose, New home�391County, Idaho. West 2250 North, Madison
i.s
As per the REScheek provided by the contractortheheat loss fo -.1home figured as
follows.
UA value: 488
Design indoor temp. = 70 F
IIII'
Design outdoor condition = -20 F
Delta T: 90 F
Heat loss =: 43,920 BTU
Infiltration value:
.50% =: 24!1400 BTU
Minimum BTU required — 68,320 BTU
it is proposed to install a 80,000 BTU furnace with a 3 ton blower,
There is also a 29,,000 BTU Gas fireplace, in the home.
I .ave also included a layout of proposed Sizing and location drawn on blue
punts Wvided from contractor.
drew Johns
Johnson Heating LLC
HVAC License # 1327
State of Idaho
ITY 0 F R EXB U R