Trus Joist
rim board
A3
Web stiffeners
required each
side at E1W
8'r diameter maximum hole for
W/8" - 20" deep blocking panels:
"' '" ureter maximum for
I panels 911" deep or
sorter than 12" long.
Do not cut flanges.
Trus Joist rim
board
LING REQUIREMENTS
TJI® Joists at bearings: Two 8d (2Y2") box nails (1 each side), 1 Y2"
minimum from end.
Blocking panels, rim Joist or rim board to bearing plate:
TWO blocking panels or rim joist: 10d (3") box nails at 6" o.c.
Trus Joist rim board: Toenail with 10d (3") box nails at 6" o.c. or
16d (3Y2") box nails at 12" o.c.
Shear transfer: Connections equivalent to decking nail schedule.
Rim board, rim Joist or closure to TJI® olst:
13/4" width or less: Two 10d (3") box nails, one each at top and
bottom flange.
2f/e"thru 2112" widths: Two 16d (3Y'r) box nails, one each at top and
bottom flange.
3112" width: Toenail Joist to rim Joist with one 10d (3") box nail each
side of joist top flange.
2x4 minimum squash blocks: Two 10d (3") box nails, one each
at top and bottom flange.
DO NOT allow workers
to walk on joists
until braced.
INJURY MAY RESULT.
WARNING
Joists are unstable until braced laterally
Bracing Includes:
• Blocking • Sheathing
• Hangers • Rim Board
• Strut Lines • Rim Joist
WARNING NOTES:
-4
DO NOT stack building
materials on unsheathed
joists. Stack only over
beams or walls.
Lack of concern for proper bracing during construction can result in serious accidents.
Under normal conditions if the following guidelines are observed, accidents will be avoided
1. All blocking, hangars, rim boards and rim Joists at the end supports of the TJI "Joists must be completely installed and properly nailed.
2. Lateral strength, like a braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished
by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the and of the bay.
3. Safety bracing fines of IX4 (minimum) must be nailed to a braced and wall or sheathed area as in note 2 and to each Joist. Without this
bracing, buckling sideways or rollover Is highly probable under light construction loads - like a Worker or one layer of unnailed Sheathing.
4. Sheathing must be totally attached to each TJI d Inlet before additional loads can be placed on the system.
5. Ends of cantilevers require safety bracing on both the top and bottom flanges.
8. The flanges must remain straight within a tolerance of X" from Ince alignment.
TJ-Xpert framing plan requi.es the True Joist Framer's Po
See Trus Joist Framer's Pocket :--...- -or Product Trademark Information
CITY OF RCXBuM6.
TlXpert.
151 L
LEVEL NOTES
File Name: 60 -Glen Romney Spec Home 071306.JOB
Level Name: Main Floor
Plotted: 7/11/2006 16:55
Design Status:
Main Floor... 7/11/2006 16:53
NOTE: Level design times indicated above provir
assurance for proper level stacking,
Design Methodology; ABC
Floor Area Loading Is:
40psf Live Load and 12 psf Dead Load
Maximum Joist Deflection:
L/480 Live Load
L/240 Total Load
TJ -Pro Rating Information:
Weighted Average: 50
Lowest Ratinq: 43
Highest Rating: 69
Glued d Nailed Decking is Required
Direct Anolied Ceilinq is Not Required
Floor Decking: 23/32" Structurwood Edge Gold 124"
Span Rating)
Normal O.C. Spacing = 16"*
*Unless noted otherwise
E
�.
CITY OF REXBURG
Scale: 11411 = 1'
JOB COMMENTS
60 -Glen Romney
Pico" Idaho
Spec Home
N
By
TMain186 83440929256-3299
SYMBOL LEGEND
Point Load
Line Load
Area Load
❑90 Beam By Others
O Detail Callout Label
(See Framer's Packet Guide)
HANGER LIST - Simpson Sttonq-Tie Company, Inc.®
Plot ID Qty Product Label Top Nails Face Nails Member Nails Notes
H1 41 IUTll 10-NIO 2-NIO
Hanger Notes:
JOIST AND BEAM LIST
Plot SD Length Product
Plies
Qty
A See Layout 11 7/8" TSI 110 joist
ACCESSORIES LIST
Rml 16' 1 1/4"Z li 7/8" 1.3E TimberStxand LSL
1
12
Bkl 1' 2.25" 11 7/8" TJI 110 BSockinq Panels
1
7
Bkl* 10" 11 7/8" TJI 110 Blocking Panels
1
1
Shi 4' x 8' 23/32' Structurwood Edge Gold (24" Span Rating)
1
48
Bk*, Random length blocking panel cuts
Bk, Blocking Panels; RM, Rim Board
LEVEL NOTES
File Name: 60 -Glen Romney Spec Home 071306.JOB
Level Name: Main Floor
Plotted: 7/11/2006 16:55
Design Status:
Main Floor... 7/11/2006 16:53
NOTE: Level design times indicated above provir
assurance for proper level stacking,
Design Methodology; ABC
Floor Area Loading Is:
40psf Live Load and 12 psf Dead Load
Maximum Joist Deflection:
L/480 Live Load
L/240 Total Load
TJ -Pro Rating Information:
Weighted Average: 50
Lowest Ratinq: 43
Highest Rating: 69
Glued d Nailed Decking is Required
Direct Anolied Ceilinq is Not Required
Floor Decking: 23/32" Structurwood Edge Gold 124"
Span Rating)
Normal O.C. Spacing = 16"*
*Unless noted otherwise
E
�.
CITY OF REXBURG
Scale: 11411 = 1'
JOB COMMENTS
60 -Glen Romney
Pico" Idaho
Spec Home
N
By
TMain186 83440929256-3299
SYMBOL LEGEND
Point Load
Line Load
Area Load
❑90 Beam By Others
O Detail Callout Label
(See Framer's Packet Guide)