HomeMy WebLinkAboutEARTHWORK INSPECTION 4 - The Grove at Thomson FarmsInspection Date
05/13/2021
File Name
20001DFR051321RB
Inspector's Signature Inspector's Name
Russ B
Reviewer's Signature Reviewer's Name
E. Vail
Reviewed Date
05/17/2021
5E48B683-E17E-415D-9140-6054B7A270FD 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Daily Field Report
Project Name
The Grove
Time Start
09:30 AM
Client
Stillwater Equity Partners
Contractor
Hill and Sons Excavation
Time End
12:45 PM
Inspection Type(s)
Earthwork Inspection
Location(s)
Did densities tests at The Grove, between the
Hickey, Black Oak, and Linden buildings. We
tested the final grade on material for the curbs to
be poured on.
Observations/ Remarks
Couldn’t get many passing tests with 2 and 4 inch tests. More water and compaction was added that
resulted in backscat tests were fairly easy to come by
Items observed are in general conformance with approved project documents and jurisdictional requirements.