HomeMy WebLinkAboutCHECKLIST - 06-00243 - 233 Jill Dr - New SFRC C IAESIDENT LAL PLAN IIE KL . IST Date: 5 �-(� Project ptzt-��{E.1E z * onmig: (2003 International Residential Code) Number of Stories: Floor Area (s fl: I 7d finished, Building Penult Number: C)! iW-0 z`f Job Address: Z�� � I � (��� Basement: (feD No/F' Unfin . .......... .... _� 1 7 Q unfinished, IWIq garage Fixtures,,0 /Ml Valuation: $ ��Permitee F$�< 7 5 Plan Check Fee* $��l�'� the 2a[}3ditof ona esl ential Code should be Ived The follo Imematj IR dwM9 comments based 0 e' 110-n of the resolved before a building pen�ruut is issued. This correction list is -not a b Rd'1* f ons does �.otperrr�tm ing pernu The approval of plans andspec icati the violation of any section of the 1ntemafional Residential Code or any fed ral state or local regulations, PLAN CHECK M A. Plans ;."/ To ScaleLegible Plot N Plan. Y / lood Plain Floor l Foundation Plan X Vol Section showing construction details All Building Elevations 4-1 D esign Crzte�.a (shall be Mentif ed OR . dans as W d RioP85 m.p.h., Sn'OW 35 1b. Per sq ft.) —Truss Calculation Sheets & iiiiiFloor Joist Details �Mecham'cal Design Ener gy Calculafi�ons M20 & Ch 11 B. Zoning (check one in some cases LDR2. ' and. MDR may apply) LDR LDRl Lotarea—LDR- 125000 sq. ft. (width 80 ft. min) (width60 ft. nM.)-(LDRI duplex - 101000 sq. ft. min.) &LDRI - 8 000 sq. ft I i e, MM C ,Use - Ing I e _ Family Duplex (LDRI only - Conditional use ernut? D. Set Racks (taken from eaves) ✓Front set ]pack (32 ft. from curb) Note: 60°/o min of front Yard green Rear set back (LDR 25 ft. & LDRl 20 ft.) � � Mn Sidesbacks (6" for every ft.,- of building height with LDR 7.51 min...& LDRl 6'r .,,/' Building -Height (maximum 30 ft.) E.,Foo#uigs Proper Size (as per Table 4Q3.1, use ].504 psf unless soil type xs known, Table 401.4.1 for sail beanng0 MUO Rebar (2-44 cont" us) Footzn ]Depth (3 6 below finished grade and 12'% below undisturbed soil.-, 18" to top of Slab — inte�.or} F. Foundation '`� Fvundation walls w/ rebar (city ordm*ance) 1/2" Anchor Bolts with 2"x 2"x 3l16"square washers (incl. interior bearing walls) R403 Oil sift: soil shall be designed per R405) /Foundation Drainage (foundations VIOZDam�praafin gfWaterproofing io FinishR406-1 (fnd. extends 6" mm above grade -R40401.6) ace access of 18"' x 24" rm" Crawl n. R408,3 (n -lay differ xfmech appliance xs m M . craspace i1�13D5.1.4) az-;u-% r 1 500 �.5� sf. (with moistLue ba�xiear 1 '. sf.:p�� CraN�rl Space Ventilation/Insulation =1 sf vent per I �i.�asuIate %Tsii vent to �ns�de nf homed R408-.2 wit=.j of each corer /Gradi_ng slope away from house, R401.3 G. Frame /Seismie Hold DoAms and Braced Wall Panels (R602.10) /Floors foists sized as per R502.3, WjIood Io*sts sized per manuft. joists Under Load Bearing partitions shall be doubled.R542.4 fr. Tables fox engineered pro�.u�t� Girders sized per R502.5 or per manu pK Cantilevers (comply wifli R502.3.3 or manuft ilisfmaiola) . ft.) and 'Floor Sheathing. (3/41, min for joists _24.," oc&5/S_"forjoists I.' OC)R5034PRI /Wa11(bearing and nonbearing) stud sizes height &spacing per Table 602.3(5) R602.3 Headers in Bearing WaR shall b designed as per Tables 502.5(1&2) 8602.7 #Snow Roof Trusses (desigped accordin to R802.10.1 35-(Local 9 and 90 b ,mph winds and Truss tic -downs. (R802.10.5) ✓AtticI-b Access 22" x 30" n. opening (RSO'n He xterior Covering 1VIasonry and stucco shall have weather resistive barrier over exterior sheathing R703.2 & 703.9.1 00f Covering and Ventilation Roof VentiIation as per R806 A . 12) w/ ice protection(Other type: ,phalt Shingles (slope>2,io comply v/ R905. J. �irewalls. G c arage[House drywall separation (protect ext. walls & beams supporting habitable space) R309.2 Door from Garage io House (1 3/8" solid wood or tee}. door, or 20 min. r fire -rated door).8309.1 o Family DwellingSeparation (I hr fire separation) 5upparting structure also rated. R317.1 "win homes & Townhozises (2 hr se i ar.,q-Lf,,p 415 Ion& - overbum protection or parapet) R317.2 f 1J P� One hr wallsparallel to and within 3.... _. - ---- .... _ . -- - ft.. of property I1ne w/ NO operlm*gs. R302 Penetrations in previous 3ltems to comply with R317.3 X General Requirements --e�House Numbers R-321 alf Qpelaable 3 sf -windo' oar 'Mech. Ventilation in bathrooms W water closets, and sn*m'lar rooms. R303.3 Interior and exterior Stair illumination shall comply With R303.60 �atkoom Fixture Clearances cOm'gure R307.2 ply W1th I'i One room at least 120 sf Other habitable rooms 70 sf. rMn w/ a rnin, dimension of 7 ft. R304 *'areas w1sloped ceil 1 ngs less than - Sft in - height - &, furYed ceilings -less than-7ft-DD N[] T camPlY in oz, 4-L �, � U1 fit U1 Ul �•� U 1 uyulru an r3a "area miist Pe at least 1�yt high rooms TV/ Slopelvo, ceiling -D-210*2 ntilevered floors. Egress clearance from Widow wells Under Ga `� Gjazina at Hazardous Locations R308 �j� Emergency Egress in all sleepm'g rooms and basements with habitable space R3,10 One required Exit Door shall comply N-vith R31194 �'° Landirxgs at top and bottom of stairways R311.5-94, and each side of each exteriordoor. R311,64*3 Stay Rise / Run (7 3/4" max. rise & 1 0." min. tread, nosing rifeq"d <1 I") Staff* Width (3 611 min), Stairway Headroom (61 S" min.) —Handrails (34"to 3S" above sta* ff- no sing) (R311 6 5) �` Special conditions for circular, spILral and winder stairways and bulkhead enclosures R311.5.8 /St Frotec��o� (enclosed accessible, space, under stai*rs shall be cove -red with 1/2" drywall) R311*12 airwqI . Handraa��s complyingwith R311.5.6 /Guardrails compl with R312 U,�, Y1M9 &//S-moke Alarrns beach bedroom and cormnon area and one on each level) (R 313) L. Energy Homes with glazing < 15% of gross area of ext. walls (Townhouses < 25%) to comply W/ t7therwise shall meet requirements ofIEC`C fog respectiYebuilding type. N1141.2 �Vapar retarder on warm in winter side of walls,, ceding and floors R318 ✓ Water Heater heat traps IECC 504.7- or IECC-503393839 503.33A3 D-Liet seating andinsulation N1103.3&4 Plans match quantities &values on 'a "passing" REScheck'compliance report M. Mechanical CTas anipliances not in bedrooms, bathrooms, toilet rooms, or storage closets G24061 A.V :� Room access 24' ruin width/Attic access clear Chapter 11. peeing 2Qx30/Under floor no. 2200. M1305 -Potential vent/connector offset > 75% of total height (Exception provided by G2428) G2427.6.4 Vent length 25I'max w/ transition (-5' per 90 deg tumsM15013✓Dryer 7 Gas "point of delivery" and material used to determine pipe sizing. - G2413