Loading...
HomeMy WebLinkAboutPROJECT INFO, CHECKLIST - 06-00230 - 673 Johnson St - New SFRSINGLE FAMILY RESIDENTIAL REXBURG City of Rexburg Amcrica' Family Community Department of Community Development 19 E. Main St. / Rexburg, ID. 83440 Phone (208) 359-3020 / Fax (208) 359-3022 Project Information Permit # 0600230 Permit Type Single Family Residential Project Name 673 Johnson Ave - Leishman Site Address 673 JOHNSON AVE Parcel # RPRHNDS2020170 Project Description Names Associated with this Project Type Name Contact Phone # License # Exp Date Contractor Kay, Jared Jared Kay 208-716-2374 9999 12/31/2006 Contractor Rexburg Plumbing & Heating Nephi/Dean 208-390-0510 C-10095 12/31/2006 Contractor Rexburg Plumbing & Heating Nephi/Dean 208-390-0510 HVCC1416 09/30/2006 Fixtures 2 - R-Fuel piping fixture or appliance outlet(s) additional 1- R-Fuel (gas) piping fixture or appliance outlet 1- R-Dryer vents additional 4 - R-Bath fan vents additional 1- R-Decorative gas -fired appliance(s) additional 1- R-Furnace 1- R-Exhaust or vent ducts 1- R-Garbage Disposal 1- R-Water Softener 4 - R-Water Closet and/or Urinal 1- R-Clothes Washing Machine 1- R-Dish Washer 1- R-Floor Drain 1- R-Water Heater 6 - R-Sink (Lavatory, Kitchen, Mop or Bar Sink) 4 - R-Tub and/or Shower Unit 1- R-Sprinkler Print Name Date Issued: Signature Date Issued By: o�aezguR�. C I T Y OF SINGLE FAMILY RESIDENTIAL `.� REXBURG City of Rexburg Americ4Family Commupri'y Department of Community Development 19 E. Main St. / Rexburg, ID. 83440 Phone (208) 359-3020 / Fax (208) 359-3022 Project Information Permit Type Single Family Residential Site Address 673 JOHNSON AVE Project Description Fee Information Project Valuation $219,229.2( Mechanical Residential Fixtures 165.00 Building Permit Fee 1,665.75 Plan Check Fee 166.58 Residential Plumbing Permit Fee 208.00 Fire Impact 184.61 Hookup Fee/Sewer 1,000.00 Hookup Fee/Water 1,550.00 Park Impact Fee 604.97 Police Impact Fee 158.11 Water Meter & Parts 317.00 Total Fees Paid $6,020.02 Print Name Signature Permit # 0600230 Project Name 673 Johnson Ave - Leishman Parcel # RPRHNDS2020170 Project Details Residential, one and two family (Any materials 1,822 SQFT Unfinished Basements (all use group) 1,822 SQFT Utility, miscellaneous, private garages (Any Cot 732 SQFT Date Date Issued: Issued By: 59 RESIDENTIAL PLAN CHECKLIST (2003 International Residential Code) Date: 5- - Z5-- Building Permit Number: Or, 00,10 30 v Project: Ze,15&,,,%, Job Address: 67/rf 3 t/e �r.n5ox VG . Zoning: /1 ZNumber of Stories: Basement. _ esa No/Fin. mil Fixtures: 7-1_ INWe-finim We aprcielronL mm�nio door Area (sf): /02 Z finished, /87— unfinished, 4iZ5—mge Mechanical Fee: A60 The following comments based on the 2003 edition of the Intemational Residential Code should be resolved before a building permit is issued. This correction list is not a building permit The approval of plans and specifications does not permit the violation of my section ofthe International Residential Code or my federal, state or local regulations. PLAN CHECK s ZPo Scale '_'i+[_)Legible lot Plan LIood Plain _Floor/ Foundation Plan Section showing construction details _All Building Elevations _Design Criteria(shall be identifie plans as Wind - 85 m.p.h., Snow - 35 lb. Per sq ft.) QTmss Calculation Sheets loor Joist Details QMechanical Design LEn.rgy Calculations (R320 & Ch 11) B. Zoning (circle one— new zoning designations adopted in 2005) LDRI 12,000 sf min. (width 80 ft. min) elOISR8,000 sf min. (width 60 ft. min); Duplex 10,000 sq. ft. min. with C.U.P. 21,780 sf min. (width 150 ft min) Duplex allowed with C.U.P. Other (Verify zoning requirements) c. u Ingle Family _Duplex (LDRI only - Conditional use oermiO D.'�et Backs (taken from eaves) / Front set back (32 ft. from curb) _Noce: 60% min of front yard green F . set back (LDRI 25 ft. & LDR2 20 ft.) 'Xsides set backs (6" for every ft, of building height with LDR - 7.5' min., & LDRI - 6' min.) wilding -Height (maximum 30 ft.) EE F Wings Proper Size (as per Table 403.1, use 1500 psf unless soil type is known, Table 401.4.1 for soil hearing) /ebar (244 continuous) Zoting Depth (36" below finished grade and 12" below undisturbed soil; 18" to top of slab — interior) OFF ad2tion Foundation walls w/ rebar (city ordinance) Z1/2" Anchor Bolts with 2"x 2"x 3/16" square washers (incl. interior bearing walls) R403.1.6.1 Foundation Drainage (foundations on sift soil shall be designed per R405) ,--Damp proofing/Waterproofing to finish grade. R406.1 (f al. extends 6" min above grade R404.1.6) --Cmwl space access of 18" x 24" min. R408.3 (may differ if mech appliance is in crawl space M1305.1.4) _Crawl Space VentilatioMnsulation=l sf vent per 150 sf. (with moisture barrier 1 sf per 1500 sq. _j}.) and within 3' of each corner (insulate walls vent to inside of home) R408.2 �rading slope away from house. R401.3 me euirmc Hold Downs and Braced Wall Panels (R602.10) joists sized as per R502.3, Wood 1-joists sized per manufr. o' is Under Load Bearing Partitions shall be doubled. R502.4 [ ers sized per R502.5 or per manufr. Tables for engineered products randlevers (comply with R502.3.3 or manufr instruction) .1 �Fl.or Sheathing (3/4" min forjoists 24" M & 5/8" for joists 16" oe) R503.2.2 Wall (bearing and nonbearing) stud sizes, height & spacing per Table 602.3(5) R602.3 Headers in Bearing Wall shall be designed as per Tables 502.5(1&2) R602.7 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) /R r and Truss tie -downs. (R802.10.5) Attic Access 22" x 30" min. opening (R807) HH E tenor Covering vlasonry and stucco shall have weather resistive barrier over exterior sheathing R703.2 & 703.9.1 1. $eof Covering and Ventilation ✓_Roof Ventilation as per R806 Asphalt Shingles (slope>2:12) w/ ice protection. (Other type: to comply w/ R905.--) 4GJ. rrewalls arage/House drywall separation (protect ext. walls & beams supporting habitable space) R309.2 /Door from Garage to House (1 318" solid wood or steel door, or 20 min. fire -rated door) R309.1 Two Family Dwelling Separation (1 br fire separation) Supporting stmclure also rated. R317.1 Twin homes & Townhouses (2 hr separation & 4' overbum protection or parapet) R317.2 One hr walls parallel to and within 3 ft of property line w/ NO openings. R302 Penetrations in previous 3 items to comply with R317.3 K General Requirements House Numbers R321 Half Openable 3sfwindow or Mech. Ventilation in bathrooms, water closets, and similar rooms. R3035 Antrior and exterior stair illumination shall comply with R303.6. Zone Fixture clearances comply with Figure R307.2 one room at least 120 sf; /ther habitable rooms 70 sf min w/ a min. dimension of 7 ft. R304 'areas rw/sloped ceilings less than 5 ft in height & fi rred ceilings less than 7 f DO NOT comply •50% or more of the required area most be at least 7ft high in rooms w/ sloped ceiling —Egress clearance from window wells under cantilevered floors. R310.2 Glazing at Hazardous Locations R308 /-Emergency Egress in all sleeping rooms and basements with habitable space R310 /e required Exit Door shall comply with R311.4 ZLendings at top and bottom of stairways 11311.5.4, and each side of each exterior door. R311.43 /-Is�mir Rise un (7 3/4" max. rise & 10" min. tread, nosing req'd if <I 1 ") _Stair Width (36" min), tairway Headroom (6' 8" min.),ffamlmils (34"to 38" above stair nosing)(R311.5) 'Special conditions for circular, spiral and winder stairways and bulkhead enclosures R311.5.8 Stairway Protection (enclosed accessible space under stairs shall be covered with 1/2" drywall) R311.2.2 /Guwdmils complying with R312 Zmoke Alarms (each bedroom and common area and one on each level) (R 313) L. Energy /Homes with glazing < 15% of gross area of ext. walls (Townhouses <25%) to comply w/ Chapter 11. 'Otherwise shall meet requiremems ofIECC far respective building type. N1101.2 apor retarder on warm in winter side of walls, ceiling and floors R318 Water Heater heat tmps IECC 504.7 Duct scaling and insulation N1103.3&4 or IECC 50333.3, 503.33.43 �/Plans match quantities & values on a "passing" REScheck compliance report M. Meehantcal Gas appliances not in bedrooms, bathrooms, toilet rooms, or storage closets G24062 RRoom access 24" min width/Attic access clear opening 20x30/Under Floor r.o. 22x30. M1305 LDryer Vent length 25' max w/ 8' transition (-5' per 90 deg turns) M1501.3 _Flue chase shown on plans (B-vents not to be inside insulated walls without insulation shield)