Project Information
Permit # 0600230
Permit Type Single Family Residential
Project Name 673 Johnson Ave - Leishman
Site Address 673 JOHNSON AVE
Parcel
# RPRHNDS2020170
Project Description
Names Associated with this Project
Type Name Contact
Phone # License # Exp Date
Contractor Kay, Jared Jared Kay
208-716-2374 9999 12/31/2006
Contractor Rexburg Plumbing & Heating Nephi/Dean
208-390-0510 C-10095 12/31/2006
Contractor Rexburg Plumbing & Heating Nephi/Dean
208-390-0510 HVCC1416 09/30/2006
Fixtures
2 - R-Fuel piping fixture or appliance outlet(s) additional
1-
R-Fuel (gas) piping fixture or appliance outlet
1- R-Dryer vents additional
4 -
R-Bath fan vents additional
1- R-Decorative gas -fired appliance(s) additional
1-
R-Furnace
1- R-Exhaust or vent ducts
1-
R-Garbage Disposal
1- R-Water Softener
4 -
R-Water Closet and/or Urinal
1- R-Clothes Washing Machine
1-
R-Dish Washer
1- R-Floor Drain
1-
R-Water Heater
6 - R-Sink (Lavatory, Kitchen, Mop or Bar Sink)
4 -
R-Tub and/or Shower Unit
1- R-Sprinkler
Print Name
Date Issued:
Signature Date
Issued By:
o�aezguR�. C I T Y OF SINGLE FAMILY RESIDENTIAL
`.� REXBURG City of Rexburg
Americ4Family Commupri'y Department of Community Development
19 E. Main St. / Rexburg, ID. 83440
Phone (208) 359-3020 / Fax (208) 359-3022
Project Information
Permit Type Single Family Residential
Site Address 673 JOHNSON AVE
Project Description
Fee Information
Project Valuation
$219,229.2(
Mechanical Residential Fixtures
165.00
Building Permit Fee
1,665.75
Plan Check Fee
166.58
Residential Plumbing Permit Fee
208.00
Fire Impact
184.61
Hookup Fee/Sewer
1,000.00
Hookup Fee/Water
1,550.00
Park Impact Fee
604.97
Police Impact Fee
158.11
Water Meter & Parts
317.00
Total Fees Paid $6,020.02
Print Name
Signature
Permit # 0600230
Project Name 673 Johnson Ave - Leishman
Parcel # RPRHNDS2020170
Project Details
Residential, one and two family (Any materials 1,822 SQFT
Unfinished Basements (all use group) 1,822 SQFT
Utility, miscellaneous, private garages (Any Cot 732 SQFT
Date
Date Issued:
Issued By:
59
RESIDENTIAL PLAN CHECKLIST
(2003 International Residential Code)
Date: 5- - Z5-- Building Permit Number: Or, 00,10 30
v Project: Ze,15&,,,%, Job Address: 67/rf 3 t/e �r.n5ox VG .
Zoning: /1 ZNumber of Stories: Basement. _ esa No/Fin. mil Fixtures: 7-1_
INWe-finim We aprcielronL mm�nio
door Area (sf): /02 Z finished, /87— unfinished, 4iZ5—mge Mechanical Fee: A60
The following comments based on the 2003 edition of the Intemational Residential Code should be resolved
before a building permit is issued. This correction list is not a building permit The approval of plans and
specifications does not permit the violation of my section ofthe International Residential Code or my federal,
state or local regulations.
PLAN CHECK
s
ZPo Scale '_'i+[_)Legible
lot Plan LIood Plain
_Floor/ Foundation Plan
Section showing construction details
_All Building Elevations
_Design Criteria(shall be identifie plans as Wind - 85 m.p.h., Snow - 35 lb. Per sq ft.)
QTmss Calculation Sheets loor Joist Details
QMechanical Design
LEn.rgy Calculations (R320 & Ch 11)
B. Zoning (circle one— new zoning designations adopted in 2005)
LDRI 12,000 sf min. (width 80 ft. min)
elOISR8,000 sf min. (width 60 ft. min); Duplex 10,000 sq. ft. min. with C.U.P.
21,780 sf min. (width 150 ft min) Duplex allowed with C.U.P.
Other (Verify zoning requirements)
c. u
Ingle Family _Duplex (LDRI only - Conditional use oermiO
D.'�et Backs (taken from eaves)
/ Front set back (32 ft. from curb) _Noce: 60% min of front yard green
F . set back (LDRI 25 ft. & LDR2 20 ft.)
'Xsides set backs (6" for every ft, of building height with LDR - 7.5' min., & LDRI - 6' min.)
wilding -Height (maximum 30 ft.)
EE F Wings
Proper Size (as per Table 403.1, use 1500 psf unless soil type is known, Table 401.4.1 for soil hearing)
/ebar (244 continuous)
Zoting Depth (36" below finished grade and 12" below undisturbed soil; 18" to top of slab — interior)
OFF ad2tion
Foundation walls w/ rebar (city ordinance)
Z1/2" Anchor Bolts with 2"x 2"x 3/16" square washers (incl. interior bearing walls) R403.1.6.1
Foundation Drainage (foundations on sift soil shall be designed per R405)
,--Damp proofing/Waterproofing to finish grade. R406.1 (f al. extends 6" min above grade R404.1.6)
--Cmwl space access of 18" x 24" min. R408.3 (may differ if mech appliance is in crawl space M1305.1.4)
_Crawl Space VentilatioMnsulation=l sf vent per 150 sf. (with moisture barrier 1 sf per 1500 sq. _j}.) and
within 3' of each corner (insulate walls vent to inside of home) R408.2
�rading slope away from house. R401.3
me
euirmc Hold Downs and Braced Wall Panels (R602.10)
joists sized as per R502.3, Wood 1-joists sized per manufr.
o' is Under Load Bearing Partitions shall be doubled. R502.4
[ ers sized per R502.5 or per manufr. Tables for engineered products
randlevers (comply with R502.3.3 or manufr instruction)
.1 �Fl.or Sheathing (3/4" min forjoists 24" M & 5/8" for joists 16" oe) R503.2.2
Wall (bearing and nonbearing) stud sizes, height & spacing per Table 602.3(5) R602.3
Headers in Bearing Wall shall be designed as per Tables 502.5(1&2) R602.7
Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions)
/R r and Truss tie -downs. (R802.10.5)
Attic Access 22" x 30" min. opening (R807)
HH E tenor Covering
vlasonry and stucco shall have weather resistive barrier over exterior sheathing R703.2 & 703.9.1
1. $eof Covering and Ventilation
✓_Roof Ventilation as per R806
Asphalt Shingles (slope>2:12) w/ ice protection. (Other type: to comply w/ R905.--)
4GJ. rrewalls
arage/House drywall separation (protect ext. walls & beams supporting habitable space) R309.2
/Door from Garage to House (1 318" solid wood or steel door, or 20 min. fire -rated door) R309.1
Two Family Dwelling Separation (1 br fire separation) Supporting stmclure also rated. R317.1
Twin homes & Townhouses (2 hr separation & 4' overbum protection or parapet) R317.2
One hr walls parallel to and within 3 ft of property line w/ NO openings. R302
Penetrations in previous 3 items to comply with R317.3
K General Requirements
House Numbers R321
Half Openable 3sfwindow or Mech. Ventilation in bathrooms, water closets, and similar rooms. R3035
Antrior and exterior stair illumination shall comply with R303.6.
Zone
Fixture clearances comply with Figure R307.2
one room at least 120 sf; /ther habitable rooms 70 sf min w/ a min. dimension of 7 ft. R304
'areas rw/sloped ceilings less than 5 ft in height & fi rred ceilings less than 7 f DO NOT comply
•50% or more of the required area most be at least 7ft high in rooms w/ sloped ceiling
—Egress clearance from window wells under cantilevered floors. R310.2
Glazing at Hazardous Locations R308
/-Emergency Egress in all sleeping rooms and basements with habitable space R310
/e required Exit Door shall comply with R311.4
ZLendings at top and bottom of stairways 11311.5.4, and each side of each exterior door. R311.43
/-Is�mir Rise un (7 3/4" max. rise & 10" min. tread, nosing req'd if <I 1 ") _Stair Width (36" min),
tairway Headroom (6' 8" min.),ffamlmils (34"to 38" above stair nosing)(R311.5)
'Special conditions for circular, spiral and winder stairways and bulkhead enclosures R311.5.8
Stairway Protection (enclosed accessible space under stairs shall be covered with 1/2" drywall) R311.2.2
/Guwdmils complying with R312
Zmoke Alarms (each bedroom and common area and one on each level) (R 313)
L. Energy
/Homes with glazing < 15% of gross area of ext. walls (Townhouses <25%) to comply w/ Chapter 11.
'Otherwise shall meet requiremems ofIECC far respective building type. N1101.2
apor retarder on warm in winter side of walls, ceiling and floors R318
Water Heater heat tmps IECC 504.7
Duct scaling and insulation N1103.3&4 or IECC 50333.3, 503.33.43
�/Plans match quantities & values on a "passing" REScheck compliance report
M. Meehantcal
Gas appliances not in bedrooms, bathrooms, toilet rooms, or storage closets G24062
RRoom access 24" min width/Attic access clear opening 20x30/Under Floor r.o. 22x30. M1305
LDryer Vent length 25' max w/ 8' transition (-5' per 90 deg turns) M1501.3
_Flue chase shown on plans (B-vents not to be inside insulated walls without insulation shield)