HomeMy WebLinkAboutJOISTS (2) - 06-00230 - 673 Johnson St - New SFR01/08/2007 12:21 FAX 3037706324
*00
TRUS JOIST
Lon
a 002/005
January 8, 2007
Nick Leishman
Diamond L Investors
1547 W. 4300 S.
Rexburg, ID 83440
1M
by Weyerhaeuser
Subject: 673 JOHNSON ST.
At your request, I have reviewed the TJI® joist used in the referenced construction. The
conditions are shown on the enclosed sheet that was faxed to us by Brad Allen. No one
from Weyerhaeuser has verified that this information is correct. The joist should be
headered to the adjacent single joists using a TJI header as shown in our Detail H2A or
by using a 5 inch deep Microllam LVL header as shown on the enclosed sheets.
Because the header is more than 2 feet from the bearing, secondary framing such as a
2 x 6 should be installed between the header and the wall so that the sheathing span
does not exceed 24 inches o. c.
Please let us know if there are any questions on this.
Sincerely,
armon
Fram .I.T.
est Division
Enclosure
cc: Matt Garner
Brad Allen, Stock Bldg. Supply
C-1 7*l f �UTA
ei �j'C[i1d-.BLL[IfIPSS
Midwest Division -9115E.9V'Avenue— Henderson, CO 80640 - Phone 303.770.6262 - Fax
31/08/2007 12:21 FAX 3037706324 TRUS JOIST
lih 001/005
by Wayarha eu sor rp�Eyedtun u•. dusincsv
Repair Form for Damaged Residential Products
Id Utah Region: Utah, Idaho, Wyoming
9115 E. 90th Ave Henderson CO, 80640
(ph) 1-800-433-6947 or303-770-6262
Job Name / Address: 09 IAOSUvt 51. ffXhW� � Subdivision:
Sealed Letter Required ❑
Too / Bottom View:
Shade 8 Dimension
area cut:
T X
TJI Beam
De8cripticfl of D�ata.,e "Provide Loading for DBL TJI or Beam
(include desired i epair) l�))
?4n W)7w /vY►Al V j��
fill PItc1' �t ?v� ilQ+h>' o,ii. Get S�ov�s �i1 0 o-t 61 7
Joist I Beam Information
Contact / B
llder Information
Product Series:
,0
210 360 560
Your Name: y
Product Depth:
9 112"
11 7/8" 14" 16"
Company: oc
w 0 N
On Center Spacing:
12"
16" 19.2" 24"
JobsitsSuper:
/
Lji5Avlg✓I
Double TJI: ❑
Beam Product! Plies:
,�l/CC
Microllam
Builder Name:
L IAU14oj
-"Provide Loading for
Timberstrand
Builder Address:
DBL TJI or Beam
Parallam
Loading:
Phone#:
dy?0
Floor: ❑
Roof: ❑
Field Fax M
Live -
psf
Slope:
Dead
psf
Concrete/Tile Floor:
❑
Roof Tile: ❑
Lumber Dealer:
"
Dealer Location:
Reviewed By:
Date:
Sheet: of
Please Fax to Midwest Division Office at 303-770-6324
l
HANGER BACKER BLOCK G
Install tight to bottom flange with face mount hangers.
• Attach with ten 10d (3") box nails, clinched when possible.
• If necessary, increase filler and backer block height for face
mount hangers and maintain 1j8" gap at top of joist
• Filler and backer block dimensions should accommodate
required nailing without splitting.
M
TM
k-n'�ft
U-1
by Weyerhaeuser
acker block
ides of web with
e TJI® joists
HANGER BACKER BLOCK SIZE5
TJIO 110 joists: 1/8" or 1/4" , minimum length 12"
TJI® 210 joists: 114" or '/8", minimum length 12"
TJI® 360 joists: I" net, minimum length 12"
TJI® 560 joists: 2x_, minimum length 12"
USP Structural Connectors TM 1 Simoson Strono-Tie TM
Depth
TJlo
I Hanger
Depth I
TJI®
Hanger
91/2"
i 110
THF17925
91/2"
110
210
1US1.81/9.5
210 THF20925
IUS2.06/9.5
11718"
110
THF17112
?
117/8"
110
210
230
360
560
IUS1.81/11.88
210 ! THF20112
IUS2.06/11.88
230 THF23118
IUS2.37/11.88
360 THF23118 .
IUS2.37/11.88
560 THF17112-2
IUS3.56/11.88
i
14"
110
210
230
360
660
THF17140
THF20140
THF23140
THF23140
THF17140-2
14"
110
210
230
360
560
I IUS1.81/14
1US2.06/14
IUS2.37/14
IUS2.37/14
I IUS3.56/14
i6 I
210
230
366
560
THF20117
i THF23160
:THF23160
THF17167-7
16
210
230
360
560
IUS2.06/16
IUS2.37/16
IUS2.37/16
IUS3.56/16
BOLD ITALIC hangers require web stiffeners.
j
L'
U5P MPA, or Simp:
Framing Anchor bo
of header w/ back(
both sides of joist
4 -10d x 3" box nails
from each side, clinch
by Weyerhaeuser
stand L5L
U5P THO or Simpson ITT Hanger w/
4 -10d x 1'/z" top
2 -10d x 1' 12" face
! USP Structural
Connectors'
! Simpson
Stron Tie n"
Depth I
TJI®
I Hanger
Depth (
TJIa
Hanger
91/2"
110
210
TH017950
TH020950
91/2„
110
210
1TT9.5
ITT2.1/9.5
117/8" 1
110
210
230
360
560
TH017118
TH020118
1 TH023118
1 TH023118
TH035118
117/8" !
i
110
210
230
360
560
ITT11.88
ITT2.1/11.88
ITT3511,88
ITT3511.88
ITT411.88
14"
110
210
230
360
560
TH017140
TH020140
TH023140
TH023140
I TH035140
14"
110
210
230
360
560
ITT14
ITT2.1/14
ITT3514
fIT3514
r7414 =
16" i
i
210
230
360
560
TH020160
T1-1023160
j THG23160
i TH035160
16„
:.
210
230
360
560 1
ITT2.1/16
MIT3516
M1T3516
MIT416