HomeMy WebLinkAboutINSPECTION CHECKLIST - 06-00230 - 673 Johnson St - New SFRr
1QMO
FINAL INSPECTION CHECKLIST
Date: P` 3 - 0 7
Project:�,,��.,.�
Job Address: 6-73 c,/oA-,,t5tr�
Building Permit Number: P(, o o z 3 0
The following comments based on the 2000 edition of the lntemational Residential Code should be
resolved before an occupancy permit is issued. This correction list is not a building permit. The approval
of plans and specifications does not permit the violation of any section of the Intemational Residential
Code or any federal, state or local regulation.
OUTSIDE
6:louse Numbers ( visible from the street)
'-7 -
y _grade (yard is sloped away from foundation)
Sidewalk & Landscape Strip 5' wide (W/ 6" �of granular borrow (hill 12".)) --7' LS strip
Front Setback Coverage 60% min green
/' releasable or removable from the. inside for egress
V1lindows -. Covers and Screens (shall be re easab e
Window Wells min. 24" clear (out and above) well
W�`
Q Exterior Steps (7 3/4 "max. rise & 10" min. tread)
1/stairway Handrails 4 or more risers or over 30" (<4. max. spacing, of uprights)
. /Guardrails (provide if over 30" above floor/grade & 4" max sphere spacing for uprights)-
�,nandings.(36' x 36" min., not req. at the top of the stair if a door does not swing over stairs)
thresholds 1 1/2" max. above floor or landing7 3/4" max if door does not swing over landin'
� 9 9)
Posts (required to be treated, redwood or cedar if in contact of concrete / earth)
�oofing (no apparent leaks, installed properly and roofing as per plans)
) .
Masonry (lintels as per table 703.7. 1)
YROof Ventilation (as per plans)
INSIDE
Egress Doors (all egress doors must be able to open from inside without use of keys or tools)
Safety Glazing provided in all doors, within 24" of door arc and below 60", & in tub enclosure
Bathroom Ventilation (either operable window or fan that vents directly to outside)
/ Sinks Bathtubs and Showers check for caulking, operation and ( g, op t n a leaks)
Stairway Illumination (switch at top and bottom)
Stairs (7 3/4"max. riser, 10"' min. tread, (nosing 3/4"to 1 1/4" with solid risers)
Handrails Cont (34" u to 38", 1 1/2" to wall, and grip 1 1/4" to 2" dia. upright < 4",trian ular space 6" max
. _.L9._ g p )
ZGuardrails 36" high and continuous, Req'd 30" or more above here max grade or floor(, uprights 4" s
9 (P
spacing, triangular space 6" sphere max spacing)
Garage (Dry walled and taped, firewall penetrations and electrical boxes, door to house 20 min. rated,
ducts penetrating firewall must be 26 gauge min. & not open to garage)
Egress Windows (clear 20" width and 24" height, 5.7 sf min. opening with 44" max. sill height)
�moke Detectors in each sleeping room, outside in immediate vicinity and on each story/basement-
split p 9 . tY ry
split levels (w/o doors), only on upper floor --all interconnected without a disconnecting switch)
Foam Plastic (meets requirement of R318)
Water Heater Anchorage as over 4' with flex water conn. shall be anchored or strapped to building)
_ Water Heater Vent (check air flow with return in finished basement)
Clothes Dryer Ducts (solid metal ducts, no screws in duct & vent directly to outside)
/DuctSupports (metalsupported 10 min spacing &non metal as per manuf. installation rnstr,)
Duc sulation (duct in non conditioned areas shall be insulated)
Gas Line Supports spacing 10' for up to 3/4", 12' for over 1" and.6' for tubing up to 1 1/2"