Loading...
HomeMy WebLinkAboutSTAFF REVIEWS - 06-00222 - Tew By 4 Apartments - Site Plan4*'4r rip A CITY of ---------- REXBURG C1W June 9, 2006 bog Permit Number: 06 00222 Project Name: Project Type: Review Item Tew by 4 Apartme ts Site Plan Review Building Department Review Setbacks and Propertly Litres Number of Parking Spaces Snow Storage Fire Separation Parking Configuration Miscellaneous Plumbing Review Parcel #'s RPRANDR2000010 Review Action r Meets code requirements� Twenty one spaces required. Twenty four provided. Snow storage is not identified. But, there is ample space for snow storage. Meets code requirements. One parking space must be a van accessible handicapped space as per Section 1106.5 of the 2003 113C. BYO Box 280 1 E. main St. Rexburg, Idaho 83440 Phone (20$) 359-3020 Fax (208) 359-3022 Provide a accessible route to the public right -of - way that does not utilize the driveway. The plans ars not to scale and are hard to read (they are a copy of a fax}. Provide a neer set that is to scale. 1 05/22/2006 05/22/2006 05/22/2006 05/22/2006 `'-4 ITT 0 F REXBURG Americas Family vmrnu j1y June 9, 2006 ho Permit Number: 06 00222 Project Name: Project Type: Review Item Tew by 4 Apartments SitePlan Review .Fire Department Review Fire Lane Signage Additional Comments Wafer Supply Firs access Roads Parcel #'s RPRANDR2000010 so Review Action .. Aictions-R—equlr-ed—fox—Ap-p—rovaI Nonerequire with parking lot as configured. Please provide requested documentation. If you have any questions please contact Chris at 705-1312. -Unkown if building is fire sprinklered or not, please provide more details. -If not required to be fire sprinkiered, the minimum fire flow required is 275D QPM for two hours from a minimum of three usable hydrants within 400 feet each. -If fire sprinkler system is required the fire flaw requirements shall be 150Q gpim/two hours from a minimum of two fire hydrants within 45Q feet. -Please provide drawings with hydrants shown. Parking lot exceeds 150 feet and requires a means to turn dire apparatus around. See Appendix D of the 2003 International Fire Cade. -Phase provide corrected drawings. RO Box 280 19 E. Main St. Rexburg, Idaho 8344[3 Phone (208) 359-3020 Fax (208) 359-322 ArTroved zm_� 05/10/2006 05/10/2006 C1 TY 0 F RFXBURG June 9, 2006 Permit Number0 : Project Name: Proje ct Type: he 0600222 Tew by 4 Apartments Site Plan Review Review Item Planning Staff Review Approved Site Plan Parcel #'s RPRANDR2000010 Review Action AcOmns-Re-Wired fvr V Site plan needs typical sidewalk section. Revise and resubmit. P.Q Bax 280 79 F- Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Fax {208} 359-3022 Approved kL CITY REXBURG CW Artier i-ca'Fam4Y Comm ui fity June 9, 2006 Permit Number: 06 00222 Project Name: Project Type: Review Item Tew by 4 Apartments Site Plan Review Public Works Review Approved Site Plan Parcel #'s Review Action N 1 . The parking lot cannot be adjacent to the west property line without buffering. Bufferingis a fence ora 4 foot landscaped strip as defined in the Development Code. 2. We need to see details on haw the storm water system is going to be constructed. 3. A lighting plan for the parking lot must be provided. 4. A street light on the corner of Casper and Everett Place must be instafled. RO Bax 280 19 E Main St. Rexburg, Idaho 83440 Phone (2D8) 359-3020 Fax (2O8) 359-3022 # 0