Loading...
HomeMy WebLinkAboutCHECKLIST - 06-00175 - 343 Talon Dr - New SFRRESIDENTIAL PLAN CHECKLIST (2003 International Residential Code) ENEWEENNEW Date: Z16 proj" e et: Building Permit Number: Job Address: soel 3 7���10-kt � ZO nmg'* Number of Stories: � B as ement des o l Fi<.d (Note unfinished basements as.speclaX Floor Area. (szf). 7- _ � n � f,zE�z3c�., i�r.� �.� L1i1hnished, 531'gyp Fe ixtures so 92, pert) garage Mechanical Fee: The following comments based on the 2003 edition of the Intemational ResidentialCode should be. resolved before a b -u Id Ing Perm, t zs issued. This correction list is not a bui lr�in� �,��,;+ �rhA .�n�,.-�Y,n,-specifications does not pern-iit tie violation of al�y section of thestate car local reg,1Iat�arzs. PLAN CHECK, A. fans � To Scale /Plot Plan Legible YPX)flood P1ain /Foundation Flan .,�'Sect'OR shoA.ving construction details Ali Building Elevations Design Criteria (shall be. identified on plans as Trus Calculation Sheets & Mechanical Design n_�. � x��, u.�,�a.�.0 vctl VL �J1cLI1S ancl nfemationa! Residential Code or any federal., Wind - 85 m.p.h., Snow - 35 Ib. Per sq ft.) /Floor Joist Details Energy Calculations (8320 & Ch 11) Be Zoniniz (circle one —new zoning designations adopted in 2005) C�CLDRl 12..000 sf min. (width 80 ft. min) LDR2 8 ,000 sfmin. (width 60 ft. min); Duplex 10,000 sq. ft. min. with C.U.P. RR -2- 21 780 sfmin. (width I50 ft min) Duplex allowed with C.U.P. Other (Verify zoning requirements) -W. C. e _Single Family f Duplex. (LDRI only - Conditional ruseenm��? D. Set Backs (taken from eaves) Front set back (-' 2 ft. from curb} 1 Note: 60% min of front yard green Pwar set back (LDRI 25 ft. & LDR2 20 ft.) s;�IPs set backs (6" for every ft. of building hei,ltt with LDR - 7.5'min, & LDRI - 6' min.) BW'Iding-Helght (maximum 30 ft.) E. Footings Proper Size (as per Table 4 0 3. 1, use 1540 psf unless soil tyke is knowin. Table 4,01.4.1 for soil bearing) ,,fRebar (24 4 continuous) Footing Depth ('-'36" below finished grade and 12" below undisturbed soil; 18,, to trap of slab -- interior) F. Foundation oundation walls w/ rebar (city ordinance) ZF . Anchor Bolts vvi�.h 2"x 2"x 3116" square washers (incl. ii-iterII/2"Zo� bearIlia walls} R403.1.6.1 Foundation Drainage (foundations on sift soil shall be design -ed per 8405) /Damp proofingANTaterproofing to finish grade. R406-1 ffnd. extends G" min above grade R404.19-6) --�CxawI space access of 18 x 24" xnin. 844$.3 (may differ if �ra.ech appliance �.s in crawl space M 130 5.1.4) �Grawl Space 'Ventilat��n/Insu��tian =l �f'vent per I�50 sf.with maist�.�re barrier 1 sf. �r 1500 s . ft.j a�.d within 3" of each corner (instd-ate walls vent to inside of home R408-2 within ,. Grading slope away from Imusc. R401-3 G , tame eistnic Hold Downs and Braced Wall Panels (R602*10) ZFI.coors j aists sized as per R5 02.3 , Wood I- oists sized per rnanufr. Joists Under Load Bearing Partitions shall be doubled. R502*4 �rders sized'R'502.5 or per manufr. Tables for engineered pro -ducts ZCantilevers (comply with R502*33 o� manufr instruction) Zfloor Sheathing 3l4" min fog 'oi24" � ,� sts oc & 5/8" forioists 16" oc) 85031 �Wall (bearina and nonbearing) spud sizes, height &spacu ig per Table 6D2.3 (5) 8602.3 .Headers i n Bearing Wail shall be designed as p er Tables 5 02.5 (1 &2) R6 02,7 Roof Trusses desioFned accord' Ing to R$011,0. 1 Snow and 90 mph winds (Local Conditions) Rafter aid Truss tie-dc�vNTns. (R802.10.5) �ttic Access 22" x 30" min. opening (8807) H. terior Covering Masorlry and stucco shall have weatherresistive barrier over exterior sheathing 8703.2 & 703.991 �. R f Covering and Ventilation oof Ventilation as per R80-6 Asphalt Shingles (slope>2:12) w1 ice protection. (Ot-herlype, tO comply wl R905,� J. F' walls Garage/House X Door from drywall separation(protect exp, walls & beams supportrn� ace habitable �p) 8349. 2 Garage toy House �� �1$" solid wood or steel door, or 20 min, fire -rated door) R309.1 .'-'Two Family Dwelling Separation (I hr fire separations Support*ng structure also rated. R317.1 -Twin honies & Townhouses 2 hr separaiion & �' a�.�erburn protection or parapet} 8317.2 4xxe hr walls parallel to and w£ithin 3 ft of property Iine vvl Na openings. R302 Penetrations in previou.s 3 items to comply with X317.3 K.General Requirements House Numbers R321 Half Openable 3sf windovv or Mech. Ventilation in bathrooms, water closets, and similar rooms. R303.3 niexxor and exterior stair iInalIon shall cornpiy With R3 43. 6. .� B aihroarn Fixture clearan.ces. comply with Figure R3o7.2 r One room at least 120 sf ; Qtther habitable roam s 70 sf. min wl a min, dimension of ? ft. R304 *areas w/sloped ceilings less than .5 ft in height &furred ceilings less than 7 ft DCS MOT comply �jQ% or more of the regz�iYed area must be at least 7ft high in rooms w/sloped ceiling pY i` Egress clearance from window wells tender cantilevered fooxs. R310.2 i Glazing at Hazardous Locations R308 EmergencyEgress i�� alb sleeping rooms and basements with hab�table space R31d required Exit Door sha�� cQmpl�� with R311.4/One �' Landings at tap and bottom of stairways R311.5.411, and each side of each exterior door. R.311.4.3 , tai lyse 1 Rum (7 3 14" max. rise & 10 " min. tread, nosing req ' d if < I 1''� _—�Stair Width X3 6" mini, ,•,�tairway Headroom (6 8" min.)�andrails {34'"�to 39" Blair nosing)(R311.S) Zspeclal conditions for circular, spiral andwinder s�airways and bulkhead enclosures R311.5.8 aizway Protection (enclosed accessible space under stairs shall be covered with 1/2" drywall) R311*2*2 "'Isguardrails complying NNIth R312 Smoke Alarms(K�ach bed�o�rn d common axes and one aneac�x level) (R 313) L. Energy Homes with glazing < 15% of gross area of ext. walls (TownhousesC 2'%) to comply wl Chapter 11. . '�Othef��vise shall meet requirements qfIECC fir r���speetive building �vpe. NI 1��..� Vapor retarder on warm in winter side of walls, ceiling and floors IZ318 winter / *Water Heater heat traps IT,CC 504.7 Duct sealing and insulation N1103.3&4 or IECC 503.3.3.3, 503.3.3.43 Plans match quantifies & values oxo. a "p�.ssin�" REScheck compliance report M. Mechanical :� fiances nvt zn bedroonis, bathrooms-, toilet rooms, c��r storage closets G2406.2 +has �aPp i X-Roorn access 24"' min widtihlAttic access clear openir�� 20x3O/Under floor r.o. 22x30.. M1305 ZDer Vent length 2 5' max. wl 8' transibon (- 5' per 9 0 dei �hirns) MI SQ1.3 b. chase sbo�`n on playas �B-vends mot tolue be, inside insulated,walls without insulation shield)