HomeMy WebLinkAboutCHECKLIST - 06-00172 - 632 & 634 Eaglewood Dr - New TwinhomeFINAL INSPECTION CHECKLIST
Project: �V6u,--y
Job Address.: CAP�y
Building Permit Number: e' 0&0' 7 / 7Z
The fallowing comments based on the 240Q edition of the Intemational Pesidenresolved befioCe anaccunanrprr,;f ;�ral bode should be
of pians a
Code or a
-- r�lc�c�rrecr,on list is not a building permit. The approval
nd specifications does not permit the violation of any section of the Intemational Residentialny federal,stafie or local regulation.
OUTSIDE
House Numbers (visible from the street}
.grade (yard is sloped away from foundation)
/000�s ide
wal�C &Landscape S�rNp 5 wide (W/ 6" of granular b
orrow (hi.11 12's)) --7' LS strip
Front Setback Coverage 5a% min green
lb
Windows -Covers and Srreens (shall be releasable or removable from the inside for eg gess
Window We!!s min. 24" clear (out and above} wel!
...... Exterior Steps (7 314 "max. rise & 10" min. tread}
�
3� ay Handrails 4 or more risers or over 3D"
" St 'rv�r
(<411 max. spacing of uprights)
f
Guardrails (provide if over 3011 above floor/grade & 4" max sphere spacing for uprights)
Landings X36 " x 36 "mit., (not req. at the top of the stair if a door does not Swingstair
over )
r
EMI
/Thresholds 1 X12" max. above floor or landing (7 3/4max if door does not swing over landing}
X(required to be treated, redwood or cedar if in contact of concrete 1 earth)
/,%R:o ding ono apparent leaks, installed properly and roofing as per plans)
_Masonry {lintels �s per �ab�e 703.7. 1)
Roof Ventilation has per pians)
INSIDE
ME
f
Egress Doors (all egress doors must be able to open from inside without use of keys or tools)
Safety Glazing provided in a1f do'ors,�ti►vifh�n 24'" of door arc and below G0", & in.tub enclosure
/'Bathroom Ventilation (either operable window or fan that vents directly to outside)
Zks, bathtubs and Showers (check for caulking, operation and leaks)
ZSta�'rway Illumination (switch at fop and bottom)
OOOF Stairs �7 3/4"max. riser, 1 D"' min. tread, (nosing 3I4"to 1 1/4" with solid risers}
Handraills Cont (3411 t0 381", 1 X12" to wall, andgr"i 1 1I4" is 211 diam u right � 4FIAriangular space 6 " Max)
Guardrails 36" high and continuous, Req'd 3Q" or more above grade or floor(, uprights 4" Sphere max
spacing, triangular space 6" sphere max spacing)
ZGarage (Dry willed and taped, firewall penetrations and electrical foxes, door -to house 20 min. rated,
ducts penetrating firewall mush be 2.6 gauge min. & nod open to garage)
ZEE�l ress Windows(blear 20'' width and 24" height, 5.7 sf min. opening with 44" max. �si!! height)
Smoke Detectors din each sleeping room, outside in immediate vicinity and an each storylbasement-
s
split bevels (w/o days), only on upper floor --all interconnected without a disconnecting switch}
Foam plastic (meets requitement of R318)
//Water HAnchorage as over 4'with flex water conn. shall be anchored or strapped to building)
/VVater Heater Vent (chec�C air flow with return in finished basement)
Cloths Dryer Ducts (solid metal ducts, no screws in duct & vent directly to outside)
Duct Supports Imetal ducts supposed 10' min spacing & non metal as per r�anuf. installation instr..)F�
duct Insulation (duct in non conditioned areas shall be insulated)
7Gas Line Supports spacing 101 for up to 3l4", 12' for over 1" and 6' for tubing up to 1 'l12"