Loading...
HomeMy WebLinkAboutREVIEW ACTIONS - 06-00160 - Madison Memorial Hospital - Addition - Site Plan■ V36E X Ja t" f � ITT0 FREXBURGAmerica's Family Community June 8, 20,06 Permit Number: 06 00160 Project Name.. Project Type: Review Item Review Action Madison Memorial Hospital Addition Site Plan Site Plan Review Building Department Review Setbacks and Propertly dines Number of Parking Spares Parking Configuration Snow Storage Fire Separation Plumbing Review Parcel #'s RPROOOR0007900 Actio Meets code and ardiance requiremen#s. More than adequate park -Ing is provided. There is a question on handicapped spaces. Do they meet the requirements of IBC Sections 110-6.3 and 7106.4? Meets ordinance requirements. Deets ordinance requirements. Meets code and ordinance requirements. P.0 Box 280 19 E- Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-302 Approved 05/1 912 0 0 6 05/19/2006 05/19/2006 05/19/2006 05/19/2006 19 (A +,.7A i+ xis C I T Y 0 F URG June 8, 2006 Permit Number: 06 00160 Project Name: Project Type: Review item Review Action Madison Memorial Hospital Addition Site Plan Site Play Review Fire, Department Review Fire Access Roads Additional Comments Water Supply Fire Lane Signage Parcel #'s xpazaooR0007900 Actions Required f —Or A Adequate Please contact Chris at 705-1312. 1. Please provide hydrant flows for all existing and proposed hydrants. 2. Does water line tie into existing water lines other than on Mill Hallow Road? Provide fire lane signage and red curb painting throughout all access roads within complex. 19 Er Main St. Rexburg, klaho 83440 Ph -one (208} 359-3020 Fax (2Q8) 359-3022 04/01/2006 C I T Y f REXBURG Ameticak Family Gonh Review Action June 8, 2006 Permit Number: 06 00150 Project Name: Madison Memorial Hospital Addition Site Plan Project type: Site Plan Review Review Item Planning Staff Review Development Standards Review Approved Site Plan Neighborhvod Meeting Parcel #'s RPROOOR0007900 P.O Box 280 79 E Main St. Rexburg, Idaho 8344 Phone (2a8) 359-302 Fax (2(38) 359-3022 W.0 q 0=.9 I CITY OF 1-11-1-0w r� peri Family Community June 8, 2006 Permit Number: 06 00160 Project Name: Project Type: Review 'item Review Action Madison Memorial Hospital Addition S ite Plan Site Plan Review Public Works Review Approved Site Plan AC#ions, Req i� red fo_�� royal _ Comments for Plan Review of Madison Memorial Hospital Idem I ; Portions of the property shown on the site survey sheet AS 10 1 at the east end of Main Street, is not owned by the Hospital. Some of this propertyis owned by the City of Rexburg as dart of the original town site or part of the Smith Park property. This needs to be corrected prior to construction. Item 2. At the corner of Millhollow and Morgan where the curb and gutter are to be replaced, there is the existing crass drain that will need to be partially replaced. Item 3: The plans are not clear as to whether or not the curb and gutter along Morgan and Reed is to be removed and replaced. This is show as ADD ALT 1 and is not clear whether or not this is included in the project. Item 4.- The plan shows the removal of the existing 4 -inch water line an Morgan, this is not typically done, but we have no problem with it being done. Item 5: There are no details shown an how the water and sewer line crossings are to be constructed to conform to State standards. Item 6: A water valve will be required on the existing six inch line where the new water dine connects to the existing water line at the corner of Reed and 4th East. Item 7: At the very west side of the existing parking lot where storm drainage is to be modified adjacent to Ash Ave, it is shown that a 2 inch (orifice) plate will be used. Orifice plates this small are very prone to plugging and maintenance prodedures will need to be documented on how plugging will he monitored and prevented. RO Box 280 19 F, Main St. Rexburg, Idaho 8344 Phare (2Q8) 359-3020 Fax (20s) 359-3022 Appr-Qved I CITY 0 F RE URG America's F mfiy Community June 8, 2006 Permit Number: 06 00160 Project Name: Project Type: Review Item Review Action Madison Memorial Hospital Addition Slate Pian Site Plan Review s Item 8: The proposed water line layout sums very circuitous and expensive and leaves numerous dead fire hydrant lines up to two hundred feet long. These are not conducive to good fire flow and have a serious potential for allowing contamination. We request that the system be reviewed to decrease the length of these fire hydrant lead dines or to eliminate them where possible. A possible re-routing alternative is attached dor consideration. Item 9: The fire hydrant detail shows a minimum depth of four feet; our standards require that water lines be buried to a depth of five feet. Item 10: The conditional use permit requires that the development along Morgan and Reed Street be constructed in early summer of 2006. The proposed storm water pollution prevention plan shows the silt fencing being placed adjacent to the curb and gutter along Morgan and Reed. It is anticipated that the development of the landscape area and replacement of curbed gutter and sidewalk Tong Morgan Road will take place verb early in the project. The silt fencing will be required during the grading and palling of the parking lot and the development of the storm water system. It will be required that two slit fences need to be constructed. One along Reed and Morgan which will be a relatively short duration, and another one will be located south of the proposed sidewalk and landscaped area that will need to remain in effect until the site work is cQmpieted. Item 11: The storm water prevention S'WPPP on sheet C-501 shows a detail of the silk fence section; however, there is insufficient detail to determine how this is to be constructed, of what materials, to what height, and other 19 E. Mala St. Rexburg, Idaho $3440 Phone (208) 359-3020 Fax (2Q$) 359-3022 At w CITY R.EXBURG June 8, 2006 Permit Number: 06 00160 Project Name: Project Type: Review Item Review Action Madison Memorial Hospital Addition Site Plan Site Pian Review Parcel #'s RPROOOR0007900 Actions R details. P.0 Box 280 19 E. Main St. Rexburg, Idaho 83440 Phony (208) 3.59-3020 Fax (208) 359-3022 irecLfor A rvval _ Ap�proved Item 12: Sheet C-502 has a note that requires a notice of intent be filed with the environmental protection agency. Has this notice of intent been filed? A copy of correspondence with LPA needs to be provided to the City. Also, sheet L-101 shows the landscaping area to done slang Reed and Morgan. The pian shows the area to be finished with lawn; however, there is no clarification whether or not this is to be sod, seeded or other methods. We reed clarification on this item. It is anticipated that with, commitments made to the adjacent property owners that sad would be utilized in the landscaping area. Item. 13. Sheet ES -101 shows the site electrical plan and where light fixtures are to be placed. We have not received details, as required by the development code, an the type of fixtures that are to be used. Catalog cuts and other details will need to be provided for review of the lighting plan design. The lighting plan design submitted for this project should show lighting intensitities in the parking lots and also at the property boundaries around the project site. 1#em 14: Utility pians for water, storm sewer and sewer mint be submitted to, and approved by the Idaho Department of Environmental in Idaho Falls, Idaho.