8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Apr 28 11:41:05 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-U0WEZx8joA2OyowLW58VJdoSZEuS3P8QNuUI_pzMBBC
Scale = 1:79.8
T2 T2
B1
W1
W2 W3 W4
W1
W2
W3
W4
T1 T1
B1B2
ST12
ST10
ST11
ST9
ST7
ST8ST6
ST4
ST5
ST3
ST2
ST1
ST10
ST11
ST9
ST7
ST8 ST6
ST4
ST5
ST3
ST2
ST1
W5
W5
A B
C
D
E
F
G
H
I
J K
S R Q P O N M L
BDBC
BE
BF BG
BH
BI BJ BK BL BM BN BO
5x6
3x4
5x6
4x5
3x6
3x4 4x5
3x6
3x4
5x6
2x4
2x4
2x4
2x4 2x4
5x6
5x6
2x4 2x4
2x4
5x6
2x4 2x4
5x6
3x4 3x4
7-0-0
7-0-0
8-4-13
1-4-13
16-9-10
8-4-13
25-2-6
8-4-13
33-7-3
8-4-13
35-0-0
1-4-13
42-0-0
7-0-0
-1-0-0
1-0-0
7-0-0
7-0-0
14-0-0
7-0-0
21-0-0
7-0-0
28-0-0
7-0-0
35-0-0
7-0-0
42-0-0
7-0-0
43-0-0
1-0-0
0-
4
-
3
10
-
1
0
-
3
11
-
3
-
1
5
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [D:0-3-0,0-3-0], [F:0-1-12,0-1-8], [H:0-3-0,0-3-0], [J:0-1-11,Edge], [N:0-3-0,0-3-0], [Q:0-3-0,0-3-0], [AN:0-0-0,0-0-0], [AN:0-0-0,0-0-0],
[AO:0-0-0,0-0-0], [AR:0-0-0,0-0-0], [AR:0-0-0,0-0-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.73
0.70
0.69
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.39
-0.54
0.17
0.30
(loc)
O-P
M-O
J
M-O
l/defl
>999
>919
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 342 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4,W5: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std *Except*
ST12,ST9: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F
1.6E
BRACING-
TOP CHORD Sheathed or 2-2-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 5-2-11 oc bracing.
WEBS 1 Row at midpt F-O, F-P
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2144/0-5-8 (min. 0-2-5), J=2144/0-5-8 (min. 0-2-5)
Max Horz B=237(LC 11)
Max UpliftB=-830(LC 12), J=-830(LC 12)
Max GravB=2161(LC 2), J=2161(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-BE=-3973/1734, C-BE=-3881/1749, C-D=-3758/1765, D-E=-3569/1778, E-BF=-2912/1398,
F-BF=-2799/1414, F-BG=-2799/1414, G-BG=-2912/1398, G-H=-3570/1778, H-I=-3758/1765,
I-BH=-3881/1749, J-BH=-3973/1734
BOT CHORD B-BI=-1470/3439, S-BI=-1470/3439, R-S=-1467/3435, R-BJ=-1078/2788, Q-BJ=-1078/2788,
P-Q=-1078/2788, P-BK=-711/2089, BK-BL=-711/2089, BL-BM=-711/2089, O-BM=-711/2089,
N-O=-1076/2788, N-BN=-1076/2788, M-BN=-1076/2788, L-M=-1469/3435, L-BO=-1472/3439,
J-BO=-1472/3439
WEBS F-O=-587/1135, G-O=-885/442, G-M=-494/785, M-BD=-557/239, I-BD=-474/177,
F-P=-587/1135, E-P=-885/442, E-R=-494/785, C-BC=-474/177, R-BC=-557/239
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=42ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-13 to 3-1-10, Interior(1) 3-1-10 to 21-0-0, Exterior(2R) 21-0-0 to 25-2-6,
Interior(1) 25-2-6 to 43-0-13 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C
for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=830,
J=830.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
Continued on page 2
Job
FAIRVIEW-FREEMONT CM
Truss
A1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER FREEMONT-FAIRVIEW CM
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Apr 28 11:41:07 2021 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-QOd__dAzKnI6B64kdWAzO2uo22ZwXJejrBzP3izMBBA
LOAD CASE(S) Standard
Job
FAIRVIEW-FREEMONT CM
Truss
A2
Truss Type
Common
Qty
20
Ply
1
KARTCHNER FREEMONT-FAIRVIEW CM
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Apr 28 11:41:08 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-ubBNBzBb55QzpGfwBEhCxFQznRuSGmps4rizb8zMBB9
Scale = 1:70.3
T2 T2
B1
W1
W2 W3
W4
W1
W2W3
W4
T1 T1
B1B2AB
C
D
E
F
G
H
I
J K
Q P O N M L
R
S T
U
V W X Y Z AA AB AC AD
3x6
5x6
3x6
5x6
4x8 4x5
3x6
3x4
1.5x4
4x5
3x6
3x4
1.5x4
4x8
5x6
8-4-13
8-4-13
16-9-10
8-4-13
25-2-6
8-4-13
33-7-3
8-4-13
42-0-0
8-4-13
-1-0-0
1-0-0
7-0-0
7-0-0
14-0-0
7-0-0
21-0-0
7-0-0
28-0-0
7-0-0
35-0-0
7-0-0
42-0-0
7-0-0
43-0-0
1-0-0
0-
4
-
3
10
-
1
0
-
3
11
-
3
-
1
5
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [J:0-1-11,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.73
0.74
0.70
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.39
-0.55
0.17
0.30
(loc)
N-O
N-O
J
N-O
l/defl
>999
>904
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 207 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-2-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 5-3-12 oc bracing.
WEBS 1 Row at midpt F-N, F-O
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2144/0-5-8 (min. 0-2-5), J=2144/0-5-8 (min. 0-2-5)
Max Horz B=-237(LC 10)
Max UpliftB=-830(LC 12), J=-830(LC 12)
Max GravB=2164(LC 2), J=2164(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-R=-3957/1727, C-R=-3867/1742, C-D=-3779/1759, D-E=-3590/1783, E-S=-2917/1398,
F-S=-2803/1414, F-T=-2803/1414, G-T=-2916/1398, G-H=-3590/1783, H-I=-3779/1759,
I-U=-3867/1742, J-U=-3957/1727
BOT CHORD B-V=-1457/3427, Q-V=-1457/3427, Q-W=-1079/2794, P-W=-1079/2794, P-X=-1079/2794,
O-X=-1079/2794, O-Y=-711/2092, Y-Z=-711/2092, Z-AA=-711/2092, N-AA=-711/2092,
N-AB=-1077/2794, M-AB=-1077/2794, M-AC=-1077/2794, L-AC=-1077/2794, L-AD=-1459/3427,
J-AD=-1459/3427
WEBS F-N=-588/1136, G-N=-891/447, G-L=-508/804, I-L=-481/182, F-O=-588/1136, E-O=-891/447,
E-Q=-508/804, C-Q=-481/182
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=42ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-13 to 3-1-10, Interior(1) 3-1-10 to 21-0-0, Exterior(2R) 21-0-0 to 25-2-6,
Interior(1) 25-2-6 to 43-0-13 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C
for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=830,
J=830.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
FAIRVIEW-FREEMONT CM
Truss
A3
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER FREEMONT-FAIRVIEW CM
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Apr 28 11:41:10 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-qzJ7ceCrdigh2ZpJIfjg0gVK0Fdfkdr9X9B3g0zMBB7
Scale = 1:86.1
T2 T3
B1
W1
W2 W3
W4
W1
W2
W3
W4
ST10
ST8
ST9
ST7
ST5
ST6
ST4
ST2
ST3
ST1
ST8
ST9
ST7
ST5
T1 T4
B3B2AB
C
D
E
F
G
H
I
J K
T R
Q
P N M LAO
S AP AQ ARO
AS AT AU
5x6
3x4
3x6
3x6
4x5
3x6
3x6
6x8
3x6
3x4
2x4
2x4
2x4
2x4
2x4
5x6
5x6
2x4 2x4
2x4
2x4
3x6
3x6
SpecialSpecial
Special
8-4-13
8-4-13
13-7-8
5-2-11
16-9-8
3-2-0
16-9-10
0-0-2
19-8-0
2-10-6
25-2-6
5-6-6
33-7-3
8-4-13
42-0-0
8-4-13
-1-0-0
1-0-0
7-0-0
7-0-0
14-0-0
7-0-0
21-0-0
7-0-0
28-0-0
7-0-0
35-0-0
7-0-0
42-0-0
7-0-0
43-0-0
1-0-0
0-
4
-
3
10
-
1
0
-
3
11
-
3
-
1
5
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [D:0-3-0,0-3-0], [F:0-1-12,0-1-8], [F:0-3-4,Edge], [R:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.69
0.57
0.86
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.17
-0.24
0.02
0.16
(loc)
L-N
L-N
J
J-L
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 299 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std *Except*
ST10,ST7: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F
1.6E
BRACING-
TOP CHORD Sheathed or 4-5-2 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except:
10-0-0 oc bracing: L-N,J-L.
WEBS 1 Row at midpt F-Q
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 0-3-8 except (jt=length) B=0-5-8, Q=6-4-0, P=6-4-0.
(lb) - Max Horz B=-237(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) O except B=-202(LC 27), Q=-1086(LC 8), P=-112(LC 14), J=-409(LC 8),
S=-148(LC 4)
Max Grav All reactions 250 lb or less at joint(s) P, O except B=675(LC 19), Q=2994(LC 1), J=1122(LC 20),
S=362(LC 21)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-717/309, C-D=-498/305, D-E=-259/345, E-F=-196/1007, F-G=-568/282, G-H=-1292/596,
H-I=-1489/572, I-J=-1711/554
BOT CHORD B-T=-249/533, T-AO=-494/333, S-AO=-494/333, S-AP=-494/333, R-AP=-494/333,
R-AQ=-494/333, Q-AQ=-494/333, Q-AR=-149/250, P-AR=-149/250, O-P=-149/250,
O-AS=-149/250, N-AS=-149/250, N-AT=-72/713, M-AT=-72/713, M-AU=-72/713, L-AU=-72/713,
J-L=-406/1416
WEBS F-N=-483/1100, G-N=-916/383, G-L=-411/889, I-L=-527/204, F-Q=-1852/603, E-Q=-905/379,
E-T=-400/826, C-T=-539/209
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=42ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch left and right
exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) O except (jt=lb) B=202
, Q=1086, P=112, J=409, S=148.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
Continued on page 2
Job
FAIRVIEW-FREEMONT CM
Truss
A3
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER FREEMONT-FAIRVIEW CM
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Apr 28 11:41:11 2021 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-JAtVq_DUO0oXgjNVsMEvZu2VmfzuT44JmpxdCTzMBB6
NOTES-
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 258 lb down and 135 lb up at 14-2-4, and 258 lb down and 142 lb up at
16-2-4, and 258 lb down and 142 lb up at 18-2-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-F=-84, F-K=-84, B-J=-14
Concentrated Loads (lb)
Vert: AP=-258(F) AQ=-258(F) AR=-258(F)
Job
FAIRVIEW-FREEMONT CM
Truss
B1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER FREEMONT-FAIRVIEW CM
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Apr 28 11:41:13 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-FY?GEgFkvd2Fv1Xt_nHNeJ7_VSmbxAhbD7QjGLzMBB4
Scale = 1:40.3
T1 T1
B1
ST5
ST4
ST3
ST2
ST1
ST4
ST3
ST2
B1
ST1
A
B
C
D
E
F
G
H
I
J
K
L
M
V U T S R Q P O N
W X
4x5
3x4
5x6
3x4
22-8-8
22-8-8
-1-0-0
1-0-0
11-4-4
11-4-4
22-8-8
11-4-4
23-8-8
1-0-0
0-
4
-
3
6-
0
-
5
6-
6
-
1
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [R:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.09
0.04
0.08
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.00
0.00
0.00
(loc)
L
M
L
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 108 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 22-8-8.
(lb) - Max Horz B=114(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) B, S, T, U, V, Q, P, O, L, N
Max Grav All reactions 250 lb or less at joint(s) R, S, T, U, Q, P, O except B=251(LC 1), V=306(LC 23), L=251(LC
1), N=306(LC 24)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=2ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-13 to 1-11-3, Exterior(2N) 1-11-3 to 11-4-4, Corner(3R) 11-4-4 to 14-4-4
, Exterior(2N) 14-4-4 to 23-9-5 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, S, T, U, V, Q, P, O,
L, N.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
FAIRVIEW-FREEMONT CM
Truss
B2
Truss Type
Common
Qty
1
Ply
1
KARTCHNER FREEMONT-FAIRVIEW CM
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Apr 28 11:41:14 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-jlZeS0FMgxA6XB64XUocAWg5ms0ZgZUlSn9HpozMBB3
Scale = 1:39.7
T1 T1
B1
W1
W2
W1
W2
B2A
B
C
D
E
F
G
I H
J
K L
M
N O P Q R S T
5x6
3x6 5x6
1.5x4
3x4
1.5x4
3x6
7-6-13
7-6-13
15-1-11
7-6-13
22-8-8
7-6-13
-1-0-0
1-0-0
5-8-2
5-8-2
11-4-4
5-8-2
17-0-6
5-8-2
22-8-8
5-8-2
23-8-8
1-0-0
0-
4
-
3
6-
0
-
5
6-
6
-
1
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [H:0-3-0,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.38
0.44
0.37
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.13
-0.19
0.05
0.14
(loc)
H-I
H-I
F
F-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 95 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-6-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-0-11 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=1200/0-3-8 (min. 0-1-8), F=1200/0-3-8 (min. 0-1-8)
Max Horz B=114(LC 11)
Max UpliftB=-469(LC 12), F=-469(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-J=-1958/976, C-J=-1867/990, C-K=-1697/972, D-K=-1603/983, D-L=-1603/984,
E-L=-1697/972, E-M=-1867/990, F-M=-1958/976
BOT CHORD B-N=-798/1656, I-N=-798/1656, I-O=-442/1083, O-P=-442/1083, P-Q=-442/1083,
Q-R=-442/1083, R-S=-442/1083, H-S=-442/1083, H-T=-794/1656, F-T=-794/1656
WEBS D-H=-433/669, E-H=-465/227, D-I=-433/669, C-I=-465/227
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 11-4-4, Exterior(2R) 11-4-4 to 14-4-4,
Interior(1) 14-4-4 to 23-9-5 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C
for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=469,
F=469.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
FAIRVIEW-FREEMONT CM
Truss
B3
Truss Type
Common
Qty
3
Ply
1
KARTCHNER FREEMONT-FAIRVIEW CM
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Apr 28 11:41:16 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-f7gOtiHcCYRqmUGSfvq4FxlQ9gho8T_2v5eOtgzMBB1
Scale = 1:38.6
T1 T2
B1
W1
W2
W1
W2
B2
A
B
C
D
E
F
H G
I
J K
L
M N O P Q R S
3x6
4x5
5x6
1.5x4
3x4
1.5x4
3x6
7-6-13
7-6-13
15-1-11
7-6-13
22-8-8
7-6-13
5-8-2
5-8-2
11-4-4
5-8-2
17-0-6
5-8-2
22-8-8
5-8-2
23-8-8
1-0-0
0-
4
-
3
6-
0
-
5
6-
6
-
1
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [G:0-3-0,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.39
0.45
0.37
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.13
-0.18
0.05
0.15
(loc)
G-H
G-H
E
A-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 94 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-5-1 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-0-10 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)A=1096/0-3-8 (min. 0-1-8), E=1203/0-3-8 (min. 0-1-8)
Max Horz A=-113(LC 10)
Max UpliftA=-418(LC 12), E=-470(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-I=-1976/965, B-I=-1859/978, B-J=-1710/959, C-J=-1616/971, C-K=-1607/985,
D-K=-1702/974, D-L=-1873/992, E-L=-1964/978
BOT CHORD A-M=-792/1675, H-M=-792/1675, H-N=-437/1089, N-O=-437/1089, O-P=-437/1089,
P-Q=-437/1089, Q-R=-437/1089, G-R=-437/1089, G-S=-792/1661, E-S=-792/1661
WEBS C-G=-433/669, D-G=-465/227, C-H=-421/681, B-H=-473/230
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 11-4-4, Exterior(2R) 11-4-4 to 14-4-4,
Interior(1) 14-4-4 to 23-9-5 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C
for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=418,
E=470.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
FAIRVIEW-FREEMONT CM
Truss
C1
Truss Type
Common Supported Gable
Qty
1
Ply
1
KARTCHNER FREEMONT-FAIRVIEW CM
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Apr 28 11:41:18 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-bWo8INItkAhY0oQrmKsYLMrqSTUTcQ2LNP7UyZzMBB?
Scale = 1:24.8
T1
T2
B1
ST3
ST2
ST1
ST2
ST1
A
B
C
D
E
F
G
H
M L K J I
N
4x5
3x4 3x4
14-1-0
14-1-0
-1-0-0
1-0-0
7-0-8
7-0-8
14-1-0
7-0-8
0-
4
-
3
3-
1
0
-
7
4-
4
-
3
0-
4
-
3
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.08
0.06
0.07
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
0.00
0.00
(loc)
A
A
H
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 57 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 14-1-0.
(lb) - Max Horz B=74(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) H, B, L, M, J, I
Max Grav All reactions 250 lb or less at joint(s) H, B, K, L, J except M=274(LC 1), I=304(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=2ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-13 to 1-11-3, Exterior(2N) 1-11-3 to 7-0-8, Corner(3R) 7-0-8 to 10-0-8,
Exterior(2N) 10-0-8 to 14-1-0 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) H, B, L, M, J, I.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
FAIRVIEW-FREEMONT CM
Truss
C2
Truss Type
Common
Qty
2
Ply
1
KARTCHNER FREEMONT-FAIRVIEW CM
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Apr 28 11:41:19 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-4iMXVjJVVTpPdy?1K1OntaNtvtkfLtiUc3t2U?zMBB_
Scale = 1:24.5
T1
T2
B1
W1
A
B
C
D
E
F
G H
I
J K L M
5x6
3x6 3x6 1.5x4
7-0-8
7-0-8
14-1-0
7-0-8
-1-0-0
1-0-0
7-0-8
7-0-8
14-1-0
7-0-8
0-
4
-
3
3-
1
0
-
7
4-
4
-
3
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-2-9,0-1-8], [D:0-2-9,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.61
0.44
0.11
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.10
-0.15
0.01
0.09
(loc)
D-E
D-E
D
B-E
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 47 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-3-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)D=662/0-5-8 (min. 0-1-8), B=782/0-5-8 (min. 0-1-8)
Max Horz B=74(LC 11)
Max UpliftD=-252(LC 12), B=-310(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-F=-962/532, F-G=-828/538, C-G=-814/552, C-H=-812/535, H-I=-828/522, D-I=-960/520
BOT CHORD B-J=-380/734, J-K=-380/734, E-K=-380/734, E-L=-380/734, L-M=-380/734, D-M=-380/734
WEBS C-E=-204/277
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 7-0-8, Exterior(2R) 7-0-8 to 10-0-8,
Interior(1) 10-0-8 to 13-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C
for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) D=252,
B=310.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
FAIRVIEW-FREEMONT CM
Truss
J1
Truss Type
Jack-Open
Qty
3
Ply
1
KARTCHNER FREEMONT-FAIRVIEW CM
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Apr 28 11:41:21 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-05UHwPLl1537tG8QSSQFy?TEghSmpncn3NM9XuzMBAy
Scale = 1:20.6
T1
B1
W1
A
B
C D
F
E
G
H
2x4 1.5x4
1.5x4
0-0-8
6-0-0
6-0-0
-1-0-0
1-0-0
6-0-0
6-0-0
0-
4
-
3
3-
4
-
3
3-
9
-
1
5
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.53
0.21
0.09
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.05
-0.09
0.00
0.08
(loc)
B-F
B-F
B-F
l/defl
>999
>741
n/a
>848
L/d
360
240
n/a
240
PLATES
MT20
Weight: 23 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=390/0-3-8 (min. 0-1-8), F=272/Mechanical
Max Horz B=121(LC 12)
Max UpliftB=-135(LC 12), F=-128(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 6-0-0 zone; cantilever left and right
exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=135,
F=128.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard