HomeMy WebLinkAboutREVIEW ACTION - 06-00147 - 350 Bare St - Triplex Remodela, I i , f Q� � F h IT Y 0 F REXBUR:G America� Family Community October 17, 2008 Permit Number: 06 00147 Project Name: Project Type: Review Item Review Action 350 Bari St -Triplex Commercial Remodel Building Department Review Complies with approved Site Plan Review Exiting Review Building Cade Fire Compliance Review Hight and Area Review Plumbing Potable Water Review Miscellaneous Plumbing Sewer grain Review Plumb'Ing Storm [gain Review Water and Sewer Service Mechanical Review 1 Actions Required for Approval Site plan has been reviewed and needs modifications. See Kurt Hubbert's review. Provide stair details. Include landing widths, riser heights and tread width (from foe to toe). The stairs by the pantry are noted as 2.9. feet. The minimum width is 3. Do bath stairwells exit directly outside? Identify window size and type for each bedroom. Include dimensions from floor to window. A one hour separation is required. Provide details that identify rine hour separation at party wall and at floor ceiling. Identify smoke detectors. They mush be hardwired. Stairwells must have a minimum 6'811 headroom height. Identify ceiling height for entire basement area. Include heating duct drops. The minimum hallway dimension is 3'. Make the necessary changes to the plan and resubmit. Is the upstairs being used as an apartment or is the owner of the building residing there. If it is being used as an apartment, it must be brought up to current code standards. Critical issues are doors, windows fir a� de-T07"O-lors, . Identify heating type. If heating is forced air, each snit is required to have it's own system. 19 E. Mai n St. Rexburg, Who 8344 Phone (248) 359-3420 Fax (2a8) 359-3422 Approved