HomeMy WebLinkAboutCHECKLIST - 06-00135 - 614 & 616 Eagle Wood Dr - New Twinhomet Date: 3 -3o-66 Project: sea / i'L rs GLI /-- ternational esidential Building Permit Number: Job Address: /.�/y S (ol( z�fe/,v� .honing: LPR!,� Number of Stories.. { Basemen Ces No/ Fin. nfi . Floor Areas (�Si�yLfinished,z-,-unfimmshed.,-t,6z-,--.gara.ge 4 (� l�p JO Valuation: $ Pennit Fee: $ Fixtures 6 � Plan Check Fee: $ The fallowing comments based on the 2003 edition of the Intemational Residential Code should be resolved before a buildiong permit is issued. This correction list is not a building permit. The approval of plans and speclfications does �.oi permit the violation of any section of the Intemational Residential Code or any federal, slate or local regulations.. PLAN CHECK A. Pains To Scale. egible lel Plot PYOPlain Z/floo'r / Foundation Plan Section showing construction A11 Building Elevations details �DesrI Ilegn Criteria (shall be identified a� plans �.s mind - SS m.p.h., Snow - 35 lb. Per sq ft.} ZTinFloor Joist Detailsu� echanzcai Design zJnergy Calculations (R320 & Ch 11) B. honing - in some cases .ne _LD ^ r ( DR)�-area - LDR- '_ ,DR2 and MDR may apply) 12,000 sq. ft. min. (width 80 ft. min) & LDRI- 8, 000 sq. ft. min �WiulflOu n. min.).(_LPEkduTjex - 10,000 sq. ft. min.) C. ase Siegle Family upleX (LDRI only - Conditianal use ermit? D. Set Backs {taken from eaves /qront sed back (32 ft. from curb) .� Node: 60% min of front yard green ZRear set back (LDR 25 ft. & LDR1 20 ft.) Sides set backs (6" for every ft. of building height with LDR - 7.5' min., & LDR1 - 6min-) //Building -Height (maximum 30 ft.) E. F,66tm'ags Proper Size has per Table 403 .1, use Rebar (Z-#4 continuous} 1500 psf unless sail type is known, Table 401.4.1 for soil bearing} 00,O .Footing Depth X36" below �xz�ished grade and 12" below undisturbed sail; I S" to- tap of scala — interior) F.Foundation � Foundation walls wl rebar (pity ordinance) 112" Anchor Bolts with 2"x 2"x 3/16" square washers (incl. interior bearing walls) R4011*6,01 Zoundation Drainage (foundations on sift soil shall be designed per 8405) ,/'Damp pro ofinia/Waterproofing to finish grade. R406-1 (fnd. extends 6"' min above grade 8404,1.6) ^Crawl space access of 18""' x 24" min. R408.3 (may differ if mech appliance is in crawl space M 13 05-1.4) �----�Crawl Space Ventilation/Insulation = J. sf vest per 150 sf. (with moisture barrier within 3' of each corner (insulae wars vent to 'inside of hom�) R408-2 ri fir houses_ R4013 G. Frame Seismic Hold Dawns and Braced Wall Panels (R602.10) .f Floors foists sized as per R5 02.3 , Woad 7-joists sized per manufr. Joists Under Load Bearing Parteinns shall be doubled. 85132.4 Girders sized per R502.5 or -per manufr. Tables fox engineered products Cantilevers (comply with R502.3.3 or manufr instruction) 1 sf. per 1500 sq. ft.) and � or Sheathing (3/4-n-14 min for joists 24" oc & 5/8" %r joists 16" oc) R503.1 /XH. eaders i hC19 �t & SPUIng Table 602.3(5) 8602.3 n Bearing Wall shall be designed as per Tables 501. 5( 1&2) R602.7 ZRcoof Trusses �desi ned accord inR802.10.1)g to 35 # Snow and 90 mph w-ainds (Local �C'onditions) i ZRafter and Truss tie --downs. (R802.10.5) ZAAttticAccess, 30F1 2X Win. ope-ning (R807) H. LXterior Covering Masonry and stucco shall have weather resistive barrier over exterior sheathin R703.2g & 703.9.1 I• of Covering and Ventilatio'n Raaf Ventil.ation as per RS06 Asphalt Shingles (slope>2:12) w/ ice protecti* on. (Other type: tO comply w/ R905.� J. ewalls / Garage/House drywall separation (protect ext. walls & beams suppoirt�g habitable s acespace) R309-62 1" Door from Gara2e to House fi........ Two Family 3/811 solid u�rood or steel door., or 20 min. fire -rated door) R309..1 ]welling Separation (1 hr- fire separation) Supporti,,g structure also raced. R317.1 '11�' ,1,,-Tw7*n Names & Townhozises (2 hr searat�on & 4' ove � rburn protect ion or parapet) R317.2 One h -r walls parallel to and within then 3 ft of nrnne�T �„�� �xr� �LTiI ..,...,.ti..�......_ n-mn.� Penetrations zn previous 3 K. General Requirements -z-�Hqsoe Numbers 8321 ---VFc111Ugs. 1[-JUZ items tO comply with 8317.3 Half Openable 3sf window or Mech. Ventilation in bathrooms, water closets, mid similar rooms. R303.3 te�ior and exterior star illumination shall comply with R303A P Y Bathroom Fixture clearances comply with Figure R.307.2 _+miner nctbttable roorns 70sf_ min w/ a inin. dimension of 7 ft. IR304 *areas w/sloped ceilings less than 5 ft in height A 6irrod �vr>>7pnr. fa.,7 �� n„ �►r�� *Spm or more of the required area must he at least 7�� high inI�ooms w/sla� d ceiling 1 comp�y HUI pantilevered floors.8310.2 �� /Glazing at Hazardous Locations R308 Emergen cy Egress in all sleeping rooms and basements with habitable space R310 ,0 ne required Exit Door shall comply with R31 1 .4 Zns at too ding p and bottom of stairways R311.5.4, and. each side of each exterior doer. 8311.4.3 1" rf Stair Width x(36" min.), Stair Rise -1 Run (7 314" ma�Y. Vise& .10"min,. tread,, nosing req d �f c 1 � 11.5 ��Handrails 34 io 3$ above staynosix�g}(R3 ) �S�air�-ay headroom (� 8 m��.) S ecial con�i�ians for circulax, spiral and winder stairw=ays and bulkhead. e��closures 8311.5.8 ace under stairs shall be covered with 112" drywall} R311.2.2 Stairway Pxvtection (enclos�d accessible s� ;r ds coar� lvin with 8312H- and�ai�s complying u��ith R311.5e6 /0-0cGuardrai p , � /111" Smoke ,Alarms (each bedroom and corn.�or� ar��- �d one on each level) � X13} L. Energy Homes with glazijag C 15% of grosy ares of exfi. walls (Townhouses < 25%) to comply wl Chapter 11 *Otherwise shall meet reqiirements of IECCfor respective building type. N1141.2 Vapor retarder on warm in winter side of walls, ceiling and floors 8318 *Water Heater heat traps ICC 54.7 �uct sealing and insulation N1103.3&4 or IECC 50393.3.3-9 503.3.3.4.3 ZPIans match quantities & values on a M. Mechan-ical0 "gassing" REScheck compliance report ///IoGas appliances not in bedrooms,, bathrooms, to�l�t rooms, or storage closets G2406.2 Room access 24" min width/Attic access clear opening 20x3O/Under floor no. 2200. M1305 Z"Potential vent/connector offset > 75% of total height (Exception provided. by G-2428) G2427.6.4 Dryer Vent length 25' max w/ 8' transition (-5' per 90 deg turns) M1501.3 as "point of delivery" and material used. to determ'ne pike sizing. G2413