Loading...
HomeMy WebLinkAboutFOUNDATION CALCS - 21-00285 - 2907 Mendoza Dr - Mendoza shop.pdfFOUNDATION CALCULATIONS 50'x 120' Metal Building MVE #210679 MHB CONSTRUCTION, INC. MENDOZA FARM Rexburg, Idaho Metal Building Supplied By: R&M STEEL COMPANY 20595 Farmway Road Caldwell, ID 83607 Foundation Design by: MOUNTAIN VIEW ENGINEERING, INC. 345 No. Main, Suite A • Brigham City, Utah 84302 Phone (435) 734-9700 Fax (435) 734-9519 MAY 0 7 2021 6 pages of Calculations MOUNTAIN VIEW ENGINEERING, INC. Job.i 345 No. Man, Suite A Bdghan City, Utah 04302 Subject: Phone (435) 734-9700 Fox (435) 734-9519 MVE #210679 R&M STEEL COMPANY MENDOZAFARM DESIGN CRITERIA: Ground Snow Load 50 psf Roof Snow Load 42 psf Roof Live Load 20 psf Roof Collateral Load 1 psf Code: 2018 IBC SDS Seismic Design Category Site Class Other Loads: Soil Bearing Frost Depth 0.367 Wind Speed D Exposure D Importance Factor 1500 psf (assumed) 30 inches Notes: Reactions per R&M STEEL COMPANY drawings. Concrete and Reinforcement: Concrete Strength 3000 P.S.I. for Foundations 3500 P.S.I. for Slabs 2500 P.S.I. Used for design, no special inspection required. Rebar - ASTM A615 grade 60 Page: 1 Date: 05/07/21 By: JVL 105 mph MOUNTAIN VIEW ENGINEERING, INC. 345 No. Main, Sufte A Brigham City, Wort 84302 Phone (435) 734-97oo Fax (435) 734-9519 Page: 2 Job: MVE #210679 R&M STEEL COMPANY Date: 05/07/21 Subject: MENDOZAFARM Sidewall Footings (Lines 2 - 5 / Grids A & D) By: JVL Pp+L = 29.0 kips 198 psf Rebar d' _ OS Footing Edge from Wall = FH = 9.9 kips ft Use 6.0 ft. x 6.0 ft. x 16 inch deep footing Uplift = 6.1 kips psf Rebar fy = Moment in Footing (Mu, ULT) = 17.38 Horizontal Force Use rebar hairpins to resist horizontal force. As (req'd by calc.) = 0.310 Top of Pier to Center of Hairpin = 26.5 in L req'd = 6.3 ft - reinf. slab (6x6 W1.4xW1.4 min.) Tensile Strength of Rebar = 24 ksi L req'd = 9.9 ft - unreinforced slab Area Required = 0.238 inA2 Use # 5 hairpin w/ 12 foot legs. Weights Passive Soil Resistance Weight of Pier = 0.97 kips Wall Length for Passive Res. = 6 ft Weight of Soil Above Footing = 5.20 kips Ftg. Width for Passive Res. = 6 ft Weight of Spot Footing = 6.96 kips Passive Earth Pressure = 200 psf/ft Weight of Continuous Wall = 1.93 kips Passive Res. (Spot Footing) = 4.27 kips Weight of Continuous Ftg. = 0.00 kips Passive Res. (Wall & Pier) = 1.20 kips Weight of Slab 5 inches thick = 3.24 kips Passive Res. (Cont. Ftg.) = 0.00 kips Use Passive Res. to Resist Moment? NO Total Passive Resistance = 5.47 kips Check Soil Bearing Allowable Bearing Pressure = 1500 psf Moment Arm = 2.2083 ft Top of Wall to Grade = 24 in P (total) = 29.000 kips OS Conc. to CL A.R. = 13.5 in Overturning Moment = 21.863 kip*ft Pier Width = 12 in OTM Eccentricity = 9.0 inches Pier Depth (wall included) = 20 in Footing Offset = 0 inches Pier Height = 48 in Offset Resisting Moment = 0.00 kip*ft Wall Thickness = 8 in Passive Resisting Moment = 0.00 kip*ft Wall Height = 48 in Net Eccentricity = 9.0 inches Footing Width = 8 in B/6 = 12 inches OK Footing Depth = 16 in Bearing Pressure, q (max.) = 1413 psf OK Uplift Weight of Footing and Pier = 7.93 kips Weight of Soil & Slab Above Footing = 8.44 kips Weight of Cont. Wall & Footing = 4.00 kips Total = 20.36 kips Offset footing 0 inches. Wall Length used for Uplift = Cont. Ftg. Length for Uplift = Factor of Safety = Check Footing Flexure (Reinforcing in Direction of Horizontal Force q (min.) = 198 psf Rebar d' _ OS Footing Edge from Wall = 1.875 ft Rebar d = q (at face of wall) = 1033 psf Rebar fy = Moment in Footing (Mu, ULT) = 17.38 k*ft Concrete f = As (req'd by calc.) = 0.310 inA2 ACI 7.12 As (min) _ _Opposite Direction Reinforcing ❑ tions 11 #4 bars Min. Steel Ratio = 0.0018 7 #5 bars As per ACI 7.12 5 #6 bars Check Footing Shear Shear in Footing (Vu, ULT) = 18.54 kips Required Thickness = 6.93 in OK 3.5 in 12.5 in 60000 psi 2500 psi 2.074 inA2 10 ft 10 ft 3.34 > 1.0 OK Options 11 #4 bars 7 #5 bars 5 #6 bars Use (7) #5 bars in direction of horizontal force and use (7) #5 bars in the opposite direction. For Pier Design Nu = 46 kips **See pier calculation Mu = 35 kip*ft on page 3. Vu = 16 kips MOUNTAIN VIEW ENGINEERING, INC. 345 No. Moln, Suite A Brigham City, Utah B4302 Phone (435) 734-9700 Fox (435) 734-9519 Job _ Subject: MVE #210679 R&M STEEL COMPANY MENDOZAFARM Concrete Column Analysis (ACI 318) For X -Axis Flexure with Axial Compression or Tension Load Assuming "Short", Non -Slender Member with Symmetric Reinforcing Page: 3 Date: 05/07/21 By: JVL Input Column Geometry fc' = 2500 psi Bar Size = 5 Total # of Bars 8 1� b fy = 60 ksi # of Bars b Face 3 Tie Size = 3 77 d' = 2.375 in # of Bars h Face 3 • • b = 12 in h = 20 in � = 0.65 0.62 Loading 0.00 Pux = 46.4 kips Mux = 35.0 kip -ft Vux = 15.8 kips Placement of Reinforcement Steel X-AXIS INTERACTION DIAGRAM 500 400 300 - Y � 200 X X100 - N -100 •� .- - • ...... Limits of Interaction Diagram Design Loads •--- --• Max. Allowable Axial Load (k) -200 _.... ! . - --I. _ . _ 0 50 100 150 �Mnx (k -ft) Shear Design �V, = 17.396 �V,/2 = 8.6979 V„ > #,/2 If Vu < #c/2 then Vertical Spacing of ties shall not exceed the least of: 16 x (longitudal bar diameters) = 10 in 48 x (tie bar diameter) = 18 in Least dimension of column = 12 in i� • • _ X -------------- ------------- h • '• • d; , • * • i Y Typical Member Section DESIGN LOADS FALL WITHIN THE LIMITS OF THE INTERACTION DIAGRAM, THEREFORE, USE (8) # 5 VERTICAL BARS IN COLUMN. If V. > OV,/2 then vertical spacing of ties shall not exceed the least of: s max = A„fy/(0.75V(f,')b) = 29.333 in s max = Avfy/(50b) = 22 in s max = d/2:5 24 in = 8.8125 in USE # 3 TIES AT 8.00 INCHES ON CENTER WITH (3) IN THE TOP FIVE INCHES OF PIER. cl A Edge Layer (dl) 17.63 0.93 Interor Layer (d2) 10.00 0.62 Interor Layer (d3) 0.00 0.00 Edge Layer (d4) 2.38 0.93 X-AXIS INTERACTION DIAGRAM 500 400 300 - Y � 200 X X100 - N -100 •� .- - • ...... Limits of Interaction Diagram Design Loads •--- --• Max. Allowable Axial Load (k) -200 _.... ! . - --I. _ . _ 0 50 100 150 �Mnx (k -ft) Shear Design �V, = 17.396 �V,/2 = 8.6979 V„ > #,/2 If Vu < #c/2 then Vertical Spacing of ties shall not exceed the least of: 16 x (longitudal bar diameters) = 10 in 48 x (tie bar diameter) = 18 in Least dimension of column = 12 in i� • • _ X -------------- ------------- h • '• • d; , • * • i Y Typical Member Section DESIGN LOADS FALL WITHIN THE LIMITS OF THE INTERACTION DIAGRAM, THEREFORE, USE (8) # 5 VERTICAL BARS IN COLUMN. If V. > OV,/2 then vertical spacing of ties shall not exceed the least of: s max = A„fy/(0.75V(f,')b) = 29.333 in s max = Avfy/(50b) = 22 in s max = d/2:5 24 in = 8.8125 in USE # 3 TIES AT 8.00 INCHES ON CENTER WITH (3) IN THE TOP FIVE INCHES OF PIER. MOUNTAIN VIEW ENGINEERING, INC. 345 No. Main, Suite A Brigham City, Utah 94302 Phone (435) 734-9700 Fax (435) 734-9519 Job: Subject: Page: 4 MVE #210679 R&M STEEL COMPANY Date: 05/07/21 MENDOZAFARM Endwall Footings (Lines 1 & 6 / Grids B & C) By: JVL Pp+L = 11.3 kips 428 psf Rebar d' = 3.5 FH = 1.6 kips OS Footing Edge from Wall = Use 3.5 ft. x 3.5 ft. x 12 inch deep footing Uplift = 3.6 kips 8.5 in q (at face of wall) = 1052 Horizontal Force Use rebar hairpins to resist horizontal force. 60000 psi Top of Pier to Center of Hairpin = 26.5 in L req'd = 1.0 ft - reinf. slab (6x6 W1.4xW1.4 min.) Tensile Strength of Rebar = 24 ksi L req'd = 1.6 ft - unreinforced slab As (req'd by calc.) = Area Required = 0.038 inA2 Use # 4 hairpin w/ 4 foot legs. Weights Passive Soil Resistance Weight of Pier = 0.48 kips Wall Length for Passive Res. = 4 ft Weight of Soil Above Footing = 1.59 kips Ftg. Width for Passive Res. = 3.5 ft Weight of Spot Footing = 1.78 kips Passive Earth Pressure = 200 psf/ft Weight of Continuous Wall = 1.16 kips Passive Res. (Spot Footing) = 1.75 kips Weight of Continuous Ftg. = 0.00 kips Passive Res. (Wall & Pier) = 0.80 kips Weight of Slab 5 inches thick = 1.59 kips Passive Res. (Cont. Ftg.) = 0.00 kips Use Passive Res. to Resist Moment? NO Total Passive Resistance = 2.55 kips Check Soil Bearing Allowable Bearing Pressure = 1500 psf Moment Arm = 22083 ft Top of Wall to Grade = 24 in P (total) = 11.300 kips OS Conc. to CL A.R. = 5.5 in Overturning Moment = 3.5333 kip*ft Pier Width = 12 in OTM Eccentricity = 3.8 inches Pier Depth (wall included) = 10 in Footing Offset = 0 inches Pier Height = 48 in Offset Resisting Moment = - 0.00 kip*ft Wall Thickness = 8 in Passive Resisting Moment = 0.00 kip*ft Wall Height = 48 in Net Eccentricity = 3.8 inches Footing Width = 8 In B/6 = 7 inches OK Footing Depth = 16 in Bearing Pressure, q (max.) = Uplift Weight of Footing and Pier = Weight of Soil & Slab Above Footing = Weight of Cont. Wall & Footing = Total = 1417 psf OK 2.26 kips 3.19 kips 4.32 kips 9.76 kips Offset footirng 0 inches. Wall Length used for Uplift = Cont. Ftg. Length for Uplift = Factor of Safety = Check Footinq Flexure {Reinforcing in Direction of Horizontal Force q (min.) = 428 psf Rebar d' = 3.5 in OS Footing Edge from Wall = 1.292 ft Rebar d = 8.5 in q (at face of wall) = 1052 psf Rebar fy = 60000 psi Moment in Footing (Mu, ULT) = 5.09 k*ft Concrete f'c = 2500 psi As (req'd by calc.) = 0.134 in^2 ACI 7.12 As (min) = 0.907 in^2 Opposite Direction Reinforcing Min, Steel Ratio = 0.0018 As per ACI 7.12 Check Footing Shear Shear in Footing (Vu, ULT) _ Required Thickness = 10 ft 10 ft 2.71 > 1.0 OK Options 5 #4 bars 3 #5 bars 3 #6 bars Options 5 #4 bars 3 #5 bars Use (5) #4 bars in direction of horizontal force 3 #6 bars and use (5) #4 bars in the opposite direction. For Pier Desiqn Nu = 18 kips 7.88 kips **See pier calculation Mu = 6 kip*ft 6.00 in OK on page 5. Vu = 3 kips MOUNTAIN VIEW Page: 5 ENGINEERING, INC. Job: MVE #210679 R&M STEEL COMPANY Date: 05/07/21 345 No. Main, suite A • Brigham City, utO 84302 Subject: MENDOZA FARM By: JVL Phone (435) 734-9700 Fax (435) 731-9519 Concrete Column Analysis (ACI 318) For X -Axis Flexure with Axial Compression or Tension Load Assuming "Short", Non -Slender Member with Symmetric Reinforcing Input Column Geometry fc' = 2500 psi Bar Size = 4 Total # of Bars 4 b fy = 60 ksi # of Bars b Face 2 Tie Size = 3 I d'= 2.375 in # of Bars h Face 2 b = 12 in h = 10 in Placement of Reinforcement Steel = 0.65 d A, Loading Edge Layer (d1) 7.63 0.40 _.---._._._._ h di Pux = 18.1 kips Interor Layer (d2) 0.00 0.00 Mux = 5.7 kip -ft Interor Layer (d3) 0.00 0.00 Vux = 2.6 kips Edge Layer (d4) 2.38 0.40 i Y X-AXIS INTERACTION DIAGRAM Typical Member Section �- 250 — 200 150 -- - -- X 100 c 50 0 -50 -100 ❑1! • . • • • • Limits of Interaction Diagram M Design Loads --- --- Max. Allowable Axial Load (k) ................. .. .. 0 5 10 15 20 OMnx (k -ft) Shear Design �Vc = 7.3795 �Vc/2 = 3.6897 Vu < �V,/2 If Vu < �VJ2 then Vertical Spacing of ties shall not exceed the least of: 16 x (longitudal bar diameters) = 8 48 x (tie bar diameter) = 18 Least dimension of column = 10 DESIGN LOADS FALL WITHIN THE LIMITS OF THE INTERACTION DIAGRAM, THEREFORE, USE (4) # 4 VERTICAL BARS IN COLUMN. 25 If Vu > �Vc/2 then vertical spacing of ties shall not exceed the least of: in s max = A„fy/(0.75V(fc')b) = 29.333 in in s max = Avfy/(50b) = 22 in in s max = d/2 s 24 in = 3.8125 in USE # 3 TIES AT 8.00 INCHES ON CENTER WITH (3) IN THE TOP FIVE INCHES OF PIER. MOUNTAIN VIEW ENGINEERING, INC. 345 No, Moln, Sulte A Brigham My, Won 84302 Phone (435) 734-9700 rox (435) 734-9519 PD+L = 3.7 kips Uplift=- 0.8 kips Check Soil Bearing Allowable Pressure = 1500 psf B req'd = 1.57 ft Design uplift = 0.8 kips Slab Thickness = 5 inches Depth to top of Ftg. = 24 inches (EW) OS Conc. to CL Footing = 5.5 inches (SW) OS Conc. to CL Footing = 9.5 inches (EW) Length of Wall for Uplift = 5 feet (SW) Length of Wall for Uplift = 5 feet Wall Thickness = 8 inches Job: _ Subject: MVE #210679 R&M STEEL COMPANY MENDOZAFARM Corner Footings (Lines 1 & 6 / Grids A & D) Page: 6 Date: 05/07/21 By: JVL Use 2.0 ftz x 12 inch deep footing reinforced with (3) #4 bars each way. q = 925 psf OK Weight of Footing and Soil = 1.23 kips Weight of Concrete Slab = 0.82 kips Weight of Foundation Wall & Ftg. = 1.47 kips Total = 3.53 kips Factor of Safety = 4.41 > 1.0 OK