Loading...
HomeMy WebLinkAboutLATERAL LOAD ANALYSIS - 06-00121 - 377 Eagle Summit St - New SFRiig Des Tgn Intelligence, LLC Structural Engineering 685 W Hivy 33 Rexburg, I aho 83440 Date: August 24, 2004 To: City of Rexburg Bldg Department Rexburg, Idaho Subject: Mark Jensen Residence - Lateral Load Analysis Dear Sir or Madam: Call:* (208) 35�1-1461 FAX: (208) 359-0740 The fallowing comments refer to the house plan referenced above. All hold dawns shall be installed as required by the manufacturer. 1. All exterior framed walls are 2x6 16" ox. and are shear walls. Provide 1/2" APA rated sheathing with Sd nails at 4" o.c. at paned edges and 12" n.c.1n the field. Blocking is required at all panel edges. 2. Provide Simpson STHD14 at each side of each garage door. 3. The Great Room window wall shall be balloon framed as follows-, Provide (3) 1,75x I 1.875LVL vertically at each corner of the wail (1c)ng side parallel with the window wall). Connect these LVLs to the concrete foundation wall using Simpson HDTOA hold downs an each side of the LVL. Provide (3) 1.75xl 1.875 LVL headers above each window set (long side vertical). Connect horizontal LVL headers to vertical LVLs with 114"x 11. 7I$" steel plates on each side of tie walI with (4) �/�" A307 bolts with Tock washers and nuts on each side of thej'oint. Bolts shall be spaced 4" away from thejoint and 4"' on center minimum in two roars G" apart, one top of the plate and the ocher at the, bottom of the plate,, Please call me if you have any questions. Respectfully,, Scott A Spaulding, P Design Intelligence,/ I �C\� OF ti4a�,�Ci 3