33,8 Oaktrail-Kartchner
ESchecKSoft ware Version 3.7.3
Compliance Certificate
Project Title: "Winchester G" Oakbrook Lot 17
Report Date; 02i16106
Data filename: C:1Documents and SettcngslAdminis#ratarlDesktop117Ookbrook - Winchester C.rck
Energy Code:
Locatlon:
Construction Type:
Glazing Area Percentage:
Heating Degree mays:
Construction Site.-
338
ite.338 Oaktrail Dr.
Rexburg, ID
2003 IECC
Rexburg, I ah
Single Family
16%
8693
Owner/Agent:
DesignerlConfractar:
Kartchner Homes
3456 E. 17 Street
Ammon City, ID 83406
-
(208)8898
Ceiling 1, Flat Ceiling or Scissor Truss:
Wali 1: Wood Framer 1641 0.G.:
Window 1 Vinyl Fr .no:f oubl Pane:
Door 1: Solid-,
Door : Glass:
Floor I* All -Wood Joist/Truss -Over Outside Air:
Basement Fall I# Solid Concrete or Masonry:
Window : Vinyl Fra r ne Chou bl Fane:
Fu mace I.- Forced Hot Air: 90 AFUE
1452
143
1
34
1
1438
64
21.00.0 72
40.0
13.0
.0 40
0.350 50
0.250
0.350 1
.
0 0
0.0 81
0.350 22
Compliance Statement: The proposed buil in design d s ribed here is consistent with the building Idrn plans, specifications, and other
calculations submittedith the permit application. The proposed Widing his been desi n di
r"%� r r—*. � � t o s
to rrt the IECC urnts wry
ply with the mandatory requirements listed in the REScheck Inspection Checklist.
Builder/Desi
Company fang
l Z
asiLem
1FGOh]C{KKi�YNiix ..,.
"Winchester " Oakbrook dot 17 �.� �.��.;�LL._.._._.Page 1 of 4
,�
Date: 02/16/06
Ceilings:
REScheck Software
Inspection Checklist
IJ Ceiling is Flat Ceiling or Scissor Truss, i-40.0 cavity insulation
o mrit :
Alb -o -Grade Walls-,
LJ Wall 1: Wood Frame, 1611 O.C., R-21 . a insulation
Comments:
Basement Walls-.
D Basement Wall 1 Solid Concrete or Masonry, .0' ht/ . ' b 1 . ' nsul, R-13.0 cavity insulation
Comments:
:
Windows:
LJ Window 1:. Vinyl F rams : L ou bl Pane, -fa tori 0.350
For windows without labeled -factors, describe features:
#Panes Frame Type
Comments:
Thermal Break> Yes I No
Window * Vinyl Frarne Doubt Pane, -f@ tor: 0.350
For windows without labeled -fafor , describe features:
#Panes Frame Type Thermal Brea _ Yes No
Comments-
Doors:
mmoats
Doors:
Door I: Solid, '-facto: 0.250
Comments.
Ll Door * Glass, U -factor; 0.350
Comments:
Floors;
0 Floor 1:. 11 -Wood Joist/Truss: Over Outside Air, R-40.0 cavity insulation
Comments:
Heating and CoolingEquipment:
Ll Furnace 1 : Fray Hot fir. 90 AFUE or higher
Flake and MocijEfl umber-:
Ir Leakage-,
U Joints, Penetrations, and ail other such openings in the building envelope that are sources of air leakage rust
be sealed,
0 Recessed lights u t be 1 Type IC rated, or installed in ide an appropriate air -fight ht bI with a 0.5 "clearance fry rn
combustible materials, If non -IC rate, the fixture ar t be installed with a 31P clearance from insulation.
Skylights:
[J Mi insulation req uir rn. nt for skyli ht shafts equal, to or greater than 12 in ches is R-1 9.
`pr Retarder:
j Required on the warm -in -winter side of all non -vented framed ceilings, walis, and floors.
+ 11
`Y�4rv.i s-..vxrn-mwu�ana 4'fFY4'i �YSC-k'{-A.'F}.
i n t i dKUMOK Lot -11 Page 2 of 4
Materials Identification:
F] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment must be identified so that compliance can be determined.
Ll Manufacturer manuals for all in t tl d beating , and o lin quip and service water'h t equipment must be provided,
L] Insulation -values, glazing -factors, and heating quipment e,fficiency must be clearlymarled on the building
specifications.
Duct Insulation:
LJ
Supply duets in
unconditioned
attics or outside the building must be ire ulated t -11.
LJ
Return ducts in
uncondltiorl d
attics or outside the building rust be insulated to R-6.
.
;:]
Supply ducts in
unconditioned
spaces rust be insulated to I -11 i
Ll
Return darts in
unconditioned
paCe (except basements) mut be insulated to R-2.
L]
'where exterior walls are used
as plenums, the wall must be insulated to R-1
D
Insulation 'Is not
required on return
duats in basements.
Duct Construction:
• duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened.
• All joints, sears, and Connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -Plus -embedded -fabric, or tape. Tape and mastics must be rated uL 1 BIA or UL 181 E.
Exception: Continuously gelded and locking -type longitudinal joints and se.ams on ducts operating at fess than 2 in. w.g. (500
).
L) The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required for each separate HVAC system*. A *manual or automatic means to partially restrict or shut off the
heating and/or cooling input to each zone or Poor shall be provided.
Service Water Heating:
LJ 'Fater heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater
has arl integral
heat {trap or is part of a circulating system
.J Insulate circulating hot water pipes to the levels in Table 1
Circulating Hot Water Systems:
L1 Insulate circulating hot Fater pipes to the levels in Table 1
Swimming Pools:
LJ HCl heated i m ming pools must have r onloff heater itch and require a cover unless over 0 c f the heating energyifromn
non -de table aur es. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[I HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
.
Winchester C Oakbrook Lot 17 Page 3
f
Table 1 Minimum insulation Thickness for Circulating Hot Water Pipes
Heated eater
Temperature (°F)
170-180
140-169
100T139
Insulation Thickness in Inches by pipe Sizes
Non -Circulating Runouts
Up to 1
.
t
.
Up to 1.T"
lr !u1 in
Mains and Runouts
1.0
1.
0.5
1.0
0.5
0.5
Table 2., Minimum Insuiation Thickness for 14VA C Pipes
Piping System Types
Heating Systems
Low Press ure/Tennperature
Low Temperature
Steam Condensate afar feed water)
Cooling Systems
Chilled Water, Refrigerant and
Brine
Over ":
Fluid Temp.
Insulation
Thickness
in Inches by Pipe
Saes
I n ' F
" Runouts lit
and Less
1.25" to 2.0"
2.514 to 4ri
201-
1.0
1.5
1.5
2.0
106-200
0.5
1.0
1.0
1.
Any
1.0
1.0
1.5
.0
40-55
0.75 5
1.0
Below
NOTES TO FIELD: (Building Department Use Only)
"Winchester " Oakbrook Lot 1
Page 4 of