Heating calculation for Chris Huskinson, New home .796 (&DairyBamey Road.
As per the REScheck provided Uyfo'llows. the contractor the heat loss for the home is figured as
UA value.- 815
Design indoor temp. = 70 F
Design outdoor condi"tion — -10 F
Delta T: 80 F
Heat loss = 65,200 BTU
Infiltration value.- .45% = 29,340 BTU
Minimum BTU required = 94,540 BTU
it is proposed to install a 1 00,000 BTU #'urnace with a 4 ton air - conditioning.
I have also included a layout of proposed duct -work sizing and location drawn on blue
prints provided from contractor.
Andrew John.son
Johnson Heating LLC
HVAC License # 1327
State of Idaho