HomeMy WebLinkAboutTRUSS LAYOUT - 21-00247 - 1133 Greenside Loop - New SFR.pdfJob
BOH - JAKE SOMMER
Truss
A01GD
Truss Type
Hip Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:35 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-CDSD6v3fXR8SX7noscnwmIjICByk5Uqel91LUHzPHLE
Scale = 1:72.4
T1
T2
T1
B1
W3 W1 W2
W3W1
T4
B1
W1 W2 W1 W2 W1 W2
B3
T3
B2
A
B
C D E F G H
I
J
P O N M L K
Q R
S T U V W X Y Z AA AB AC
AD
AE AF AG AH AI AJ AKAL AMAN AO AP AQ AR
5x8 5x6
4x6
7x10 2x4 4x4
4x4
7x10 2x4
5x8 5x6
4x6
1.5x4
7x10
5-5-8
5-5-8
11-1-14
5-8-6
16-11-15
5-10-2
22-10-1
5-10-2
28-8-2
5-10-2
34-4-8
5-8-6
39-10-0
5-5-8
-2-0-0
2-0-0
5-5-8
5-5-8
11-1-14
5-8-6
16-11-15
5-10-2
22-10-1
5-10-2
28-8-2
5-10-2
34-4-8
5-8-6
39-10-0
5-5-8
41-10-0
2-0-0
0-4-73-10-54-0-20-4-73-10-58.00 12
Plate Offsets (X,Y)-- [C:0-4-0,0-1-9], [E:0-3-0,0-3-4], [F:0-3-0,0-3-4], [H:0-4-0,0-1-9], [L:0-5-0,0-4-8], [N:0-5-0,0-4-8], [O:0-4-12,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.57
0.47
0.82
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.43
-0.62
0.11
0.35
(loc)
M-N
M-N
I
M-N
l/defl
>999
>766
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 435 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-2-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size) B=3367/0-5-8 (min. 0-1-13), I=3367/0-5-8 (min. 0-1-13)
Max HorzB=-130(LC 27)
Max UpliftB=-1179(LC 8), I=-1179(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-5299/2022, C-Q=-7264/2859, Q-R=-7265/2860, D-R=-7269/2860, D-S=-7300/2878,
S-T=-7300/2878, T-U=-7300/2878, E-U=-7300/2878, E-V=-8895/3483, V-W=-8895/3483,
W-X=-8895/3483, X-Y=-8895/3483, F-Y=-8895/3483, F-Z=-8897/3486, Z-AA=-8897/3486,
AA-AB=-8897/3486, G-AB=-8897/3486, G-AC=-7367/2903, AC-AD=-7363/2902, H-AD=-7362/2902,
H-I=-5298/2021
BOT CHORD B-P=-1701/4279, P-AE=-1696/4260, AE-AF=-1696/4260, O-AF=-1696/4260, O-AG=-3484/8887,
AG-AH=-3484/8887, AH-AI=-3484/8887, N-AI=-3484/8887, N-AJ=-3484/8929,
AJ-AK=-3484/8929, AK-AL=-3484/8929, AL-AM=-3484/8929, M-AM=-3484/8929,
M-AN=-2846/7362, AN-AO=-2846/7362, AO-AP=-2846/7362, L-AP=-2846/7362, L-AQ=-1594/4258,
AQ-AR=-1594/4258, K-AR=-1594/4258, I-K=-1598/4277
WEBS C-P=-142/474, G-M=-720/1811, G-L=-1809/865, H-K=-137/468, H-L=-1475/3701,
C-O=-1432/3610, D-O=-856/482, E-O=-1873/747, E-N=0/384, F-M=-786/467
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=1179,
I=1179.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
Continued on page 2
Job
BOH - JAKE SOMMER
Truss
A01GD
Truss Type
Hip Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:35 2021 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-CDSD6v3fXR8SX7noscnwmIjICByk5Uqel91LUHzPHLE
NOTES-
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 122 lb down and 122 lb up at 5-5-8, 126 lb down and 119 lb up at 7-6-4,
126 lb down and 119 lb up at 9-6-4, 126 lb down and 119 lb up at 11-6-4, 126 lb down and 119 lb up at 13-6-4, 126 lb down and 119 lb up at 15-6-4, 126 lb down and 119 lb
up at 17-6-4, 126 lb down and 119 lb up at 19-6-4, 126 lb down and 119 lb up at 20-3-12, 126 lb down and 119 lb up at 22-3-12, 126 lb down and 119 lb up at 24-3-12, 126
lb down and 119 lb up at 26-3-12, 126 lb down and 119 lb up at 28-3-12, 126 lb down and 119 lb up at 30-3-12, and 126 lb down and 119 lb up at 32-3-12, and 122 lb down
and 122 lb up at 34-4-8 on top chord, and 372 lb down and 207 lb up at 5-5-8, 54 lb down at 7-6-4, 54 lb down at 9-6-4, 54 lb down at 11-6-4, 54 lb down at 13-6-4, 54 lb
down at 15-6-4, 54 lb down at 17-6-4, 54 lb down at 19-6-4, 54 lb down at 20-3-12, 54 lb down at 22-3-12, 54 lb down at 24-3-12, 54 lb down at 26-3-12, 54 lb down at
28-3-12, 54 lb down at 30-3-12, and 54 lb down at 32-3-12, and 372 lb down and 207 lb up at 34-3-12 on bottom chord. The design/selection of such connection device(s) is
the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-C=-84, C-H=-84, H-J=-84, B-I=-14
Concentrated Loads (lb)
Vert: C=-90(B) P=-372(B) K=-372(B) H=-90(B) Q=-90(B) R=-90(B) S=-90(B) T=-90(B) U=-90(B) V=-90(B) W=-90(B) X=-90(B) Y=-90(B) Z=-90(B) AA=-90(B) AB=-90(B)
AC=-90(B) AD=-90(B) AE=-22(B) AF=-22(B) AG=-22(B) AH=-22(B) AI=-22(B) AJ=-22(B) AK=-22(B) AL=-22(B) AM=-22(B) AN=-22(B) AO=-22(B) AP=-22(B) AQ=-22(B)
AR=-22(B)
Job
BOH - JAKE SOMMER
Truss
A02
Truss Type
Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:37 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-8cazXb5w32OAnRxB_1pOrjocA?djZPpxDTWSY9zPHLC
Scale = 1:72.4
T1
T2
T1
B1
W3 W3W2 W1 W2 W1 W2 W1 W2
T3
B3B2
W4 W4
A
B
C
D E F G H
I
J
K
P O N M L
5x8 5x8
4x6
5x8 3x4 3x4
3x4
3x4 6x8
1.5x4 5x8
4x6
1.5x4 1.5x4
7-5-8
7-5-8
13-7-6
6-1-14
19-11-0
6-3-10
26-2-10
6-3-10
32-4-8
6-1-14
39-10-0
7-5-8
-2-0-0
2-0-0
3-8-12
3-8-12
7-5-8
3-8-12
13-7-6
6-1-14
19-11-0
6-3-10
26-2-10
6-3-10
32-4-8
6-1-14
36-1-4
3-8-12
39-10-0
3-8-12
41-10-0
2-0-0
0-4-75-2-55-4-20-4-75-2-58.00 12
Plate Offsets (X,Y)-- [B:0-0-0,0-0-4], [D:0-4-0,0-1-9], [F:0-4-0,0-3-0], [H:0-4-0,0-1-9], [J:Edge,0-0-4], [O:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.60
0.56
0.72
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.34
-0.48
0.15
0.18
(loc)
N
M-N
J
N
l/defl
>999
>977
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 203 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-10-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-5-6 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=2123/0-5-8 (min. 0-2-4), J=2123/0-5-8 (min. 0-2-4)
Max HorzB=164(LC 7)
Max UpliftB=-341(LC 5), J=-341(LC 4)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2996/541, C-D=-2802/546, D-E=-3504/758, E-F=-3879/813, F-G=-3497/755,
G-H=-3500/756, H-I=-2802/546, I-J=-2996/541
BOT CHORD B-P=-511/2342, O-P=-484/2278, N-O=-760/3501, M-N=-819/3885, L-M=-358/2279,
J-L=-373/2342
WEBS D-O=-435/1636, E-O=-942/324, E-N=-152/545, F-M=-562/159, G-M=-589/223, H-M=-433/1630
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=341,
J=341.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
A03
Truss Type
Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:38 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-co8Mlw6YqMW1OaWNYlKdOwLjTOwuIu84R7G?4czPHLB
Scale = 1:71.1
T1
T2
T4
B2
W4 W3 W1 W2
W1
W2
W1
W3 W4
T3
B4B3B1
A
B
C
D E F G
H
I
M L K J
N O P Q R S T
5x8 6x8
4x6
5x8 5x6
1.5x4
3x4
3x4 7x10
1.5x4
5x6
4x6
9-5-8
9-5-8
16-4-9
6-11-1
23-5-7
7-0-13
30-4-8
6-11-1
39-10-0
9-5-8
-2-0-0
2-0-0
7-8-12
7-8-12
9-5-8
1-8-12
16-4-9
6-11-1
23-5-7
7-0-13
30-4-8
6-11-1
32-1-4
1-8-12
39-10-0
7-8-12
0-4-76-6-56-8-20-4-76-6-58.00 12
Plate Offsets (X,Y)-- [B:0-0-0,0-0-4], [D:0-4-0,0-1-9], [F:0-4-0,Edge], [G:0-3-0,0-2-3], [I:0-0-0,0-0-4], [J:0-4-12,Edge], [L:0-2-12,0-3-4], [M:0-4-0,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.88
0.76
0.59
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.35
-0.52
0.15
0.16
(loc)
I-J
I-J
I
I-J
l/defl
>999
>904
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 200 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed.
BOT CHORD Rigid ceiling directly applied or 8-8-0 oc bracing.
WEBS 1 Row at midpt E-K, F-J
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) I=1924/0-5-8 (min. 0-2-2), B=2129/0-5-8 (min. 0-2-5)
Max HorzB=188(LC 5)
Max UpliftI=-268(LC 4), B=-324(LC 8)
Max GravI=1965(LC 2), B=2141(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3008/463, C-D=-2797/499, D-E=-3100/582, E-F=-3086/579, F-G=-2280/423,
G-H=-2796/505, H-I=-2983/471
BOT CHORD B-N=-469/2365, N-O=-469/2365, M-O=-469/2365, M-P=-439/2275, L-P=-439/2275,
L-Q=-601/3098, K-Q=-601/3098, K-R=-553/3081, J-R=-553/3081, J-S=-312/2370,
S-T=-312/2370, I-T=-312/2370
WEBS C-M=-391/278, D-M=-207/712, D-L=-345/1213, E-L=-720/285, F-K=0/290, F-J=-1187/342,
G-J=-256/1335, H-J=-427/295
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) I=268,
B=324.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
A04
Truss Type
Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:40 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-ZBF6Ac7oLzmleugmf9N5TLQ2ECb4mnfNvRl69UzPHL9
Scale = 1:72.0
T2
T3
T5
B1
W4 W4
W1 W2
W1
W2 W1W3 W3
T1
T4
B1B3B2 HW2
A
B
C
D E F G
H
I
M L K JN O P Q R
5x8
5x8 5x8 5x8
3x10 4x6
5x8
1.5x4
6x8 4x4 5x8
1.5x4
7-8-12
7-8-12
17-0-9
9-3-13
22-9-7
5-8-13
32-1-4
9-3-13
39-10-0
7-8-12
-2-0-0
2-0-0
7-8-12
7-8-12
11-5-8
3-8-12
17-0-9
5-7-1
22-9-7
5-8-13
28-4-8
5-7-1
32-1-4
3-8-12
39-10-0
7-8-12
0-4-77-10-58-0-20-4-77-10-58.00 12
Plate Offsets (X,Y)-- [B:0-0-0,0-0-4], [C:0-4-0,0-3-0], [D:0-4-0,0-1-9], [E:0-4-0,0-3-0], [G:0-4-0,0-1-9], [I:0-10-0,0-1-2], [J:0-4-0,Edge], [K:0-4-0,0-3-0], [M:0-4-0,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.93
0.71
0.65
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.36
-0.52
0.13
0.13
(loc)
L-M
L-M
I
I-J
l/defl
>999
>911
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 211 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
WEDGE
Right: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt E-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) I=1924/0-5-8 (min. 0-2-1), B=2129/0-5-8 (min. 0-2-4)
Max HorzB=222(LC 7)
Max UpliftI=-281(LC 9), B=-346(LC 8)
Max GravI=1960(LC 2), B=2129(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3050/372, C-D=-2947/573, D-E=-2580/409, E-F=-2575/410, F-G=-2578/412,
G-H=-2981/595, H-I=-3075/392
BOT CHORD B-M=-413/2389, M-N=-377/2073, N-O=-377/2073, L-O=-377/2073, L-P=-435/2586,
K-P=-435/2586, K-Q=-243/2079, Q-R=-243/2079, J-R=-243/2079, I-J=-223/2417
WEBS C-M=-448/323, H-J=-466/331, D-L=-246/953, E-L=-632/256, F-K=-524/197, G-K=-247/946,
D-M=-292/876, G-J=-312/920
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) I=281,
B=346.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
A05GD
Truss Type
Hip Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:42 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-VaNsaI92ta0TtCp8naPZYmVTI0KFEctgMlEDDNzPHL7
Scale = 1:71.7
W11
T1
T2
T3
T4
T5
W12
B1W7
W6 W5
W4 W4
W5 W6
W8
W1
W2
W3
W10
W9
B1B2
A B
C
D E F
G
H I
P O N M L K
JQ R
8x12
2x4 6x8
7x10 7x10
6x8 2x4
8x12 MT20HS7x10 4x4
4x6
7x10
4x6
4x4 4x12
6x8
7-8-12
7-8-12
13-3-8
5-6-12
20-4-8
7-1-0
26-6-8
6-2-0
32-1-4
5-6-12
39-10-0
7-8-12
2-9-0
2-9-0
7-8-12
4-11-12
13-3-8
5-6-12
20-4-8
7-1-0
26-6-8
6-2-0
32-1-4
5-6-12
35-3-8
3-2-4
39-10-0
4-6-8
2-0-109-1-03-3-09-2-133-3-09-1-08.00 12
Plate Offsets (X,Y)-- [D:0-6-0,0-2-8], [F:0-6-0,0-2-8], [L:0-4-12,0-4-8], [N:0-4-12,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.64
0.54
0.99
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.32
-0.44
0.15
0.17
(loc)
M
M
J
M
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT20HS
Weight: 570 lb FT = 20%
GRIP
220/195
165/146
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T2,T4: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std *Except*
W11: 2x6 DF 1800F 1.6E or 2x6 DF SS
W1,W2,W3: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F
BRACING-
TOP CHORD Sheathed or 4-9-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt E-N, E-L, H-J
REACTIONS.(lb/size) P=5066/0-5-8 (min. 0-2-13), J=5202/0-5-8 (min. 0-2-14)
Max HorzP=180(LC 26)
Max UpliftP=-1125(LC 8), J=-1165(LC 9)
Max GravP=5217(LC 2), J=5360(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-8779/1894, C-D=-8440/1893, D-E=-6813/1604, E-F=-7053/1660, F-G=-8713/1959,
G-H=-9098/1975
BOT CHORD O-P=-1785/7444, N-O=-1661/7253, N-Q=-2222/9835, M-Q=-2222/9835, M-R=-2222/9835,
L-R=-2222/9835, K-L=-1604/7525, J-K=-1700/7754
WEBS B-O=-255/158, C-O=-20/259, C-N=-647/298, D-N=-911/4198, F-L=-957/4396, G-L=-635/272,
G-K=-27/330, H-K=-357/131, E-N=-4830/1266, E-M=-1584/6844, E-L=-4819/1253,
B-P=-8792/1953, H-J=-9191/2017
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 3 rows staggered at 0-2-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) P=1125,
J=1165.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
Continued on page 2
Job
BOH - JAKE SOMMER
Truss
A05GD
Truss Type
Hip Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:42 2021 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-VaNsaI92ta0TtCp8naPZYmVTI0KFEctgMlEDDNzPHL7
NOTES-
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 6697 lb down and 1690 lb up at 20-4-8 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-B=-84, B-D=-84, D-F=-84, F-H=-84, H-I=-84, J-P=-14
Concentrated Loads (lb)
Vert: M=-6401(F)
Job
BOH - JAKE SOMMER
Truss
A14GD
Truss Type
Roof Special Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:44 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-RyVd?_AJPCGB6VzXu?R1dBbmqp24iWnzq3jKIFzPHL5
Scale = 1:73.8
W14
T1
T3
T4
T5
B1
W2 W1 W2
W5 W8 W10
W9
W2
W1
W13 W12
W11 W7
W6
W4
W3
T2
B3B2
A B
C
D
E F G H
I
J
R Q P O N M L K
S T U V W
8x12
2x4 6x8
8x12 MT20HS
6x8 1.5x4
8x12 4x6
4x6
5x6 4x8
5x6
4x6
12x12 4x4
7x10
7x10
2x4
2-9-0
2-9-0
7-8-12
4-11-12
15-5-8
7-8-12
20-4-8
4-11-0
25-11-11
5-7-3
31-8-11
5-8-15
35-9-5
4-0-11
39-10-0
4-0-11
2-9-0
2-9-0
7-8-12
4-11-12
15-5-8
7-8-12
16-8-5
1-2-13
20-4-8
3-8-3
25-11-11
5-7-3
31-8-11
5-8-15
35-9-5
4-0-11
39-10-0
4-0-11
2-0-1011-6-06-1-211-6-08.00 12
Plate Offsets (X,Y)-- [C:0-5-0,0-4-8], [E:0-9-4,0-2-4], [H:0-6-4,0-2-4], [K:Edge,0-3-8], [N:0-6-0,0-4-8], [O:0-3-8,Edge], [P:0-5-0,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.83
0.39
0.96
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.22
-0.30
0.09
0.12
(loc)
O
O
K
O
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT20HS
Weight: 695 lb FT = 20%
GRIP
220/195
165/146
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T3,T2: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std *Except*
W1: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 5-3-15 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt F-N
REACTIONS.(lb/size) R=4675/0-5-8 (min. 0-2-9), K=4805/Mechanical
Max HorzR=262(LC 8)
Max UpliftR=-1073(LC 8), K=-1029(LC 9)
Max GravR=4847(LC 2), K=5036(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-8250/1831, C-D=-7637/1763, D-E=-7832/2030, E-F=-7040/1737, F-G=-5386/1289,
G-H=-5387/1289, H-I=-4137/962, I-J=-2797/603, J-K=-4975/1038
BOT CHORD Q-R=-1865/7111, P-Q=-1731/6843, P-S=-1437/6046, S-T=-1437/6046, O-T=-1437/6046,
O-U=-1688/7040, N-U=-1688/7040, N-V=-725/3346, M-V=-725/3346, M-W=-459/2273,
L-W=-459/2273
WEBS G-N=-527/207, H-N=-1153/4492, H-M=-2046/612, I-M=-642/2493, I-L=-3223/715,
J-L=-813/4035, F-O=-839/3052, F-N=-3724/998, B-R=-8365/1899, B-Q=-333/141, C-Q=0/315,
C-P=-861/319, D-P=-951/450, E-P=-591/1623, E-O=-987/3359
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 3 rows staggered at 0-2-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) The Fabrication Tolerance at joint E = 16%
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
10) Refer to girder(s) for truss to truss connections.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) R=1073
, K=1029.
12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
Continued on page 2
Job
BOH - JAKE SOMMER
Truss
A14GD
Truss Type
Roof Special Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:44 2021 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-RyVd?_AJPCGB6VzXu?R1dBbmqp24iWnzq3jKIFzPHL5
NOTES-
13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 5925 lb down and 1546 lb up at 20-4-8 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-B=-84, B-E=-84, E-H=-84, H-J=-84, K-R=-14
Concentrated Loads (lb)
Vert: O=-5604(B)
Job
BOH - JAKE SOMMER
Truss
A15
Truss Type
Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:45 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-v83?DKBxAVO2kfYjSjzGAP7y6DKSRzf62jStqizPHL4
Scale = 1:72.6
T2
T3
T4
B1
W1
W2
W1
W4
W8
W7
W9
W5
W6
W2
W3
T1
B3B2
A
B
C
D E F
G
H
M L K J
IN O P
5x8 6x8
2x4
3x10
3x4
3x4 6x8
4x4
3x6 1.5x4
7x10
1.5x4
5x8
7-8-12
7-8-12
15-5-8
7-8-12
24-0-12
8-7-4
30-11-8
6-10-12
39-10-0
8-10-8
7-8-12
7-8-12
15-5-8
7-8-12
17-5-8
2-0-0
24-0-12
6-7-4
30-11-8
6-10-12
35-4-12
4-5-4
39-10-0
4-5-4
0-4-711-10-512-0-26-1-211-10-58.00 12
Plate Offsets (X,Y)-- [A:0-10-0,0-0-14], [D:0-4-0,0-1-9], [F:0-5-5,Edge], [J:0-2-12,Edge], [L:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.73
0.64
0.99
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.28
-0.40
0.10
0.12
(loc)
K-L
K-L
I
A-M
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 263 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-2-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 8-2-4 oc bracing.
WEBS 1 Row at midpt E-K, E-J, G-I, C-L, B-L, D-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) A=1933/0-5-8 (min. 0-2-1), I=1933/Mechanical
Max HorzA=340(LC 8)
Max UpliftA=-323(LC 8), I=-250(LC 9)
Max GravA=1949(LC 2), I=1966(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-3042/481, B-C=-2365/415, C-D=-2222/580, D-E=-1682/349, E-F=-1191/284,
F-G=-1502/287
BOT CHORD A-M=-625/2502, L-M=-624/2506, L-N=-299/1677, N-O=-299/1677, K-O=-299/1677,
K-P=-284/1682, J-P=-284/1682, I-J=-107/853
WEBS E-K=-139/435, E-J=-1025/260, F-J=-72/451, G-J=-161/775, G-I=-1908/248, B-M=0/273,
C-L=-390/293, B-L=-808/331, D-K=-209/280, D-L=-405/1138
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=323,
I=250.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
A16
Truss Type
Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:47 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-rXBle?DBi7el_zi6Z7?kFqDGE11PvxdPW1x_vazPHL2
Scale = 1:72.4
T2
T3
T5
B1
W7
W4
W3 W3
W6
W5
W1 W2
W1
W2 W1
T1
T4
B3B2
A
B
C
D E F G
H
N M L K J I
O P Q R
7x10
5x8 5x8
5x8
4x6
1.5x4 5x6 4x6 3x4 3x4 5x8
1.5x4 5x8
7-8-12
7-8-12
15-5-8
7-8-12
21-2-15
5-9-7
27-2-1
5-11-3
32-11-8
5-9-7
39-10-0
6-10-8
-2-0-0
2-0-0
7-8-12
7-8-12
15-5-8
7-8-12
21-2-15
5-9-7
27-2-1
5-11-3
32-11-8
5-9-7
39-10-0
6-10-8
0-4-710-6-510-8-26-1-210-6-58.00 12
Plate Offsets (X,Y)-- [B:0-0-0,0-0-4], [D:0-4-0,0-1-9], [E:0-4-0,0-3-0], [G:0-4-0,0-1-9], [K:0-4-0,0-3-0], [M:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.88
0.54
0.76
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.17
-0.24
0.09
0.08
(loc)
L-M
M-N
I
B-N
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 261 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std *Except*
W6: 2x6 DF 1800F 1.6E or 2x6 DF SS
BRACING-
TOP CHORD Sheathed, except end verticals.
BOT CHORD Rigid ceiling directly applied or 8-10-1 oc bracing.
WEBS 1 Row at midpt C-M, G-J, E-L, E-K, F-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=2129/0-5-8 (min. 0-2-4), I=1924/Mechanical
Max HorzB=366(LC 8)
Max UpliftB=-372(LC 8), I=-226(LC 9)
Max GravB=2129(LC 1), I=2009(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3005/433, C-D=-2353/386, D-E=-1938/362, E-F=-1685/300, F-G=-1687/302,
G-H=-1424/198, H-I=-1896/249
BOT CHORD B-N=-559/2384, M-N=-560/2381, M-O=-354/1818, L-O=-354/1818, L-P=-377/1935,
K-P=-377/1935, K-Q=-164/1098, J-Q=-164/1098
WEBS C-N=0/278, C-M=-781/323, D-M=-127/681, G-J=-822/209, H-J=-229/1422, D-L=-229/463,
E-L=-321/250, E-K=-537/127, F-K=-537/211, G-K=-310/1250
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=372,
I=226.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
A17
Truss Type
Half Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:49 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-owIW2hEREkuTDHsUhY1CKFIecqiJNntizLQ5zTzPHL0
Scale = 1:71.3
T2
T3
W5
B1
W4 W3
W1
W2
W5 W5
W6W2
W5 W2
T1
T5
B3B2
T4
A
B
C
D E F G H
N M L K J
IO P Q R
5x8
5x6 2x4
6x8
4x6
5x8 1.5x4
5x8
1.5x4
6x8
1.5x4 6x8
1.5x4
7-8-12
7-8-12
13-5-8
5-8-12
19-10-15
6-5-7
26-6-2
6-7-3
33-1-5
6-7-3
39-10-0
6-8-11
-2-0-0
2-0-0
7-8-12
7-8-12
13-5-8
5-8-12
19-10-15
6-5-7
26-6-2
6-7-3
33-1-5
6-7-3
39-10-0
6-8-11
0-4-79-2-59-4-29-2-58.00 12
Plate Offsets (X,Y)-- [B:0-0-0,0-0-4], [C:0-4-0,0-3-4], [D:0-3-0,0-2-3], [E:0-4-0,0-3-4], [G:0-4-0,0-3-4], [K:0-2-12,0-3-4], [M:0-2-12,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.76
0.58
0.97
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.20
-0.29
0.11
0.09
(loc)
L-M
L-M
I
L
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 248 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-2-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 8-9-13 oc bracing.
WEBS 1 Row at midpt H-I, E-M, E-K, F-K
2 Rows at 1/3 pts G-I
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) I=1928/Mechanical, B=2133/0-5-8 (min. 0-2-4)
Max HorzB=411(LC 8)
Max UpliftI=-457(LC 5), B=-343(LC 8)
Max GravI=2028(LC 2), B=2133(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3006/437, C-D=-2473/469, D-E=-1968/418, E-F=-2032/451, F-G=-2039/454
BOT CHORD B-N=-552/2358, M-N=-553/2355, M-O=-498/2276, L-O=-498/2276, L-P=-498/2276,
K-P=-498/2276, K-Q=-291/1306, J-Q=-291/1306, J-R=-291/1306, I-R=-291/1306
WEBS C-M=-650/274, D-M=-129/965, E-M=-671/243, E-L=0/341, G-J=0/369, G-I=-2178/485,
E-K=-427/124, F-K=-529/204, G-K=-271/1215
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) I=457,
B=343.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
A18
Truss Type
Half Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:51 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-kIQGTNGimL9BSa?toz3gQgN0oeL4rhH?RfvC2LzPHL_
Scale = 1:71.3
T2
T3
W2
B1
W4 W1
W2
W3
W5 W6
W6
W5
W3
T1
T4
B3B2O1
A
B
C
D
E F G H I
J
Q P
O N M L KR S T U V W
3x6
6x12 MT20HS
3x6 3x4
6x8
4x6
5x8 WB
3x6
1.5x4 3x10
3x4
3x4
3x4
4x6
4x6
4x8
5-8-12
5-8-12
11-5-8
5-8-12
20-11-0
9-5-8
30-4-8
9-5-8
39-10-0
9-5-8
-2-0-0
2-0-0
5-8-12
5-8-12
11-5-8
5-8-12
18-6-10
7-1-2
25-7-12
7-1-2
32-8-14
7-1-2
39-10-0
7-1-2
0-4-77-10-58-0-27-10-58.00 12
Plate Offsets (X,Y)-- [B:0-0-0,0-0-4], [E:0-9-5,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.59
0.75
0.91
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.33
-0.48
0.13
0.10
(loc)
N-P
N-P
K
N
l/defl
>999
>979
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT20HS
Weight: 221 lb FT = 20%
GRIP
220/195
165/146
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-6-15 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 8-7-3 oc bracing.
WEBS 1 Row at midpt J-K, F-P, G-L
2 Rows at 1/3 pts I-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) K=1928/Mechanical, B=2133/0-5-8 (min. 0-2-4)
Max HorzB=357(LC 8)
Max UpliftK=-461(LC 5), B=-330(LC 8)
Max GravK=2009(LC 2), B=2133(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3053/484, C-D=-2630/493, D-E=-2504/507, E-F=-2129/457, F-G=-2631/572,
G-H=-1927/415, H-I=-1927/415
BOT CHORD B-Q=-525/2413, P-Q=-525/2413, P-R=-601/2626, O-R=-601/2626, O-S=-601/2626,
N-S=-601/2626, N-T=-562/2420, M-T=-562/2420, M-U=-562/2420, L-U=-562/2420,
L-V=-369/1563, V-W=-369/1563, K-W=-369/1563
WEBS C-P=-475/226, E-P=-133/1009, F-P=-870/301, G-N=-49/408, G-L=-985/277, I-L=-155/1222,
I-K=-2278/542
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) K=461,
B=330.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
A19
Truss Type
Half Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:52 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-CV_ehjGKXfH24ka3Mhbvytw8N2hWa7c8fIflZozPHKz
Scale = 1:70.1
T1
T2
W4
B1
W3 W1
W2
W4
W2
W4 W2 W4
W5
T4T3
B3B2
A
B
C
D E F G H
M L K J
IN O P Q R S
5x6 7x10 3x4
6x8
4x6
7x10
1.5x4
3x4
3x4
5x8
7x10
1.5x4
9-5-8
9-5-8
16-10-15
7-5-7
24-6-2
7-7-3
32-1-5
7-7-3
39-10-0
7-8-11
-2-0-0
2-0-0
7-8-12
7-8-12
9-5-8
1-8-12
16-10-15
7-5-7
24-6-2
7-7-3
32-1-5
7-7-3
39-10-0
7-8-11
0-4-76-6-56-8-26-6-58.00 12
Plate Offsets (X,Y)-- [B:0-0-0,0-0-4], [D:0-3-0,0-2-3], [K:0-4-0,0-3-0], [M:0-4-12,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.79
0.74
0.97
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.31
-0.46
0.14
0.14
(loc)
K-L
B-M
I
K-L
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 212 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-2-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 7-10-15 oc bracing.
WEBS 1 Row at midpt E-M, F-L
2 Rows at 1/3 pts G-I
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) I=1928/Mechanical, B=2133/0-5-8 (min. 0-2-4)
Max HorzB=302(LC 8)
Max UpliftI=-465(LC 5), B=-340(LC 5)
Max GravI=1998(LC 2), B=2133(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2991/551, C-D=-2771/583, D-E=-2274/493, E-F=-3141/718, F-G=-3066/705,
H-I=-272/104
BOT CHORD B-N=-520/2350, N-O=-520/2350, M-O=-520/2350, M-P=-720/3137, L-P=-720/3137,
L-Q=-705/3066, K-Q=-705/3066, K-R=-476/2068, J-R=-476/2068, J-S=-476/2068,
I-S=-476/2068
WEBS C-M=-384/275, D-M=-218/1283, E-M=-1225/365, E-L=0/268, F-K=-690/250, G-K=-296/1291,
G-J=0/381, G-I=-2644/608
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) I=465,
B=340.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
A20
Truss Type
Half Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:54 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-8t6P6PIa2GXmJ2kSU6dN1I?TKrQc26KR7c8segzPHKx
Scale = 1:70.1
T1
T2
W4
B1
W1 W2 W4 W2 W4 W2 W4 W2 W4 W5
T4T3
B3B2
W3
A
B
C
D E F G H I
O N M L K
J
5x8 5x8 5x8
3x6
4x6
5x8 3x4
3x4
3x4 7x10
1.5x4 5x8
5x8
1.5x4
7-5-8
7-5-8
13-9-8
6-4-0
20-3-4
6-5-12
26-9-0
6-5-12
33-2-12
6-5-12
39-10-0
6-7-4
-2-0-0
2-0-0
4-0-0
4-0-0
7-5-8
3-5-8
13-9-8
6-4-0
20-3-4
6-5-12
26-9-0
6-5-12
33-2-12
6-5-12
39-10-0
6-7-4
0-4-75-2-55-4-25-2-58.00 12
Plate Offsets (X,Y)-- [B:0-0-0,0-0-4], [D:0-4-0,0-1-9], [F:0-4-0,0-3-0], [H:0-4-0,0-3-4], [K:0-3-8,0-2-8], [L:0-4-12,Edge], [N:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.83
0.57
0.70
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.35
-0.50
0.13
0.20
(loc)
M
M-N
J
M
l/defl
>999
>954
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 209 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std *Except*
W2,W5: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F
1.6E
BRACING-
TOP CHORD Sheathed or 2-9-14 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-11-2 oc bracing.
WEBS 1 Row at midpt I-J
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) J=1928/Mechanical, B=2133/0-5-8 (min. 0-2-4)
Max HorzB=248(LC 8)
Max UpliftJ=-468(LC 5), B=-372(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3013/595, C-D=-2810/602, D-E=-3557/851, E-F=-3923/943, F-G=-3484/840,
G-H=-3499/846, H-I=-2192/530, I-J=-1884/489
BOT CHORD B-O=-550/2355, N-O=-528/2293, M-N=-849/3554, L-M=-946/3929, K-L=-543/2238
WEBS D-N=-450/1667, E-N=-940/330, E-M=-157/531, F-L=-568/136, G-L=-513/198, H-L=-379/1581,
H-K=-1549/459, I-K=-656/2717
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) J=468,
B=372.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
A21GD
Truss Type
Half Hip Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:13:59 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-VrvI96Mjtp92QpdPGfDYkMiJbs8JjRJAGurdJuzPHKs
Scale = 1:70.4
T1
T2
W3
B1
W1 W2 W3 W2 W3 W2 W3 W3 W2W2
T4T3
B2B2
A
B
C D E F G H
N M L K J
I
O P Q R S T U V W X Y Z AA AB AC AD
AE AF
AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT
5x8 5x8 5x8
3x10
4x6
7x10 2x4
3x4
4x4 7x10
1.5x4
4x8
5x8
5-5-8
5-5-8
12-2-4
6-8-12
19-0-12
6-10-8
25-11-4
6-10-8
32-9-12
6-10-8
39-10-0
7-0-4
-2-0-0
2-0-0
5-5-8
5-5-8
12-2-4
6-8-12
19-0-12
6-10-8
25-11-4
6-10-8
32-9-12
6-10-8
39-10-0
7-0-4
0-4-73-10-54-0-23-10-58.00 12
Plate Offsets (X,Y)-- [C:0-4-0,0-1-9], [E:0-4-0,0-3-0], [G:0-4-0,0-3-0], [J:0-3-8,0-2-0], [K:0-5-0,0-4-8], [M:0-5-0,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.86
0.47
0.40
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.45
-0.64
0.09
0.36
(loc)
K-L
K-L
I
K-L
l/defl
>999
>739
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 437 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std *Except*
W2: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size) I=3151/Mechanical, B=3313/0-5-8 (min. 0-1-12)
Max HorzB=193(LC 8)
Max UpliftI=-1228(LC 5), B=-1147(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-5217/1979, C-O=-7615/2988, O-P=-7616/2989, P-Q=-7619/2990, D-Q=-7621/2990,
D-R=-8834/3439, R-S=-8834/3439, S-T=-8834/3439, E-T=-8834/3439, E-U=-8001/3108,
U-V=-8001/3108, V-W=-8001/3108, W-X=-8001/3108, F-X=-8001/3108, F-Y=-8001/3108,
Y-Z=-8001/3108, Z-AA=-8001/3108, G-AA=-8001/3108, G-AB=-5132/1985, AB-AC=-5132/1985,
AC-AD=-5132/1985, H-AD=-5132/1985, H-I=-3034/1267
BOT CHORD B-N=-1671/4216, N-AE=-1666/4196, AE-AF=-1666/4196, AF-AG=-1666/4196, M-AG=-1666/4196,
M-AH=-2987/7616, AH-AI=-2987/7616, AI-AJ=-2987/7616, L-AJ=-2987/7616, L-AK=-3453/8852,
AK-AL=-3453/8852, AL-AM=-3453/8852, AM-AN=-3453/8852, K-AN=-3453/8852,
K-AO=-2032/5232, AO-AP=-2032/5232, AP-AQ=-2032/5232, J-AQ=-2032/5232
WEBS C-N=-127/483, C-M=-1531/3912, D-M=-1655/821, D-L=-527/1395, E-L=-456/341,
E-K=-958/388, F-K=-836/484, G-J=-2393/1112, H-J=-2181/5656, G-K=-1212/3118
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) I=1228,
B=1147.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
Continued on page 2
Job
BOH - JAKE SOMMER
Truss
A21GD
Truss Type
Half Hip Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:00 2021 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-z1TgMSNLe6Hv1zBcqMknHZFULGUYSuZKVYbArKzPHKr
NOTES-
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 122 lb down and 122 lb up at 5-5-8, 126 lb down and 119 lb up at 7-6-4,
126 lb down and 119 lb up at 9-6-4, 126 lb down and 119 lb up at 11-6-4, 126 lb down and 119 lb up at 13-6-4, 126 lb down and 119 lb up at 15-6-4, 126 lb down and 119 lb
up at 17-6-4, 126 lb down and 119 lb up at 19-6-4, 126 lb down and 119 lb up at 21-6-4, 126 lb down and 119 lb up at 23-6-4, 126 lb down and 119 lb up at 25-6-4, 126 lb
down and 119 lb up at 27-6-4, 126 lb down and 119 lb up at 29-6-4, 126 lb down and 119 lb up at 31-6-4, 126 lb down and 119 lb up at 33-6-4, 126 lb down and 119 lb up at
35-6-4, and 126 lb down and 119 lb up at 37-6-4, and 132 lb down and 118 lb up at 39-8-4 on top chord, and 372 lb down and 207 lb up at 5-5-8, 54 lb down at 7-6-4, 54 lb
down at 9-6-4, 54 lb down at 11-6-4, 54 lb down at 13-6-4, 54 lb down at 15-6-4, 54 lb down at 17-6-4, 54 lb down at 19-6-4, 54 lb down at 21-6-4, 54 lb down at 23-6-4,
54 lb down at 25-6-4, 54 lb down at 27-6-4, 54 lb down at 29-6-4, 54 lb down at 31-6-4, 54 lb down at 33-6-4, 54 lb down at 35-6-4, and 54 lb down at 37-6-4, and 68 lb
down at 39-8-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-C=-84, C-H=-84, B-I=-14
Concentrated Loads (lb)
Vert: C=-90(F) H=-125(F) I=-28(F) N=-372(F) O=-90(F) P=-90(F) Q=-90(F) R=-90(F) S=-90(F) T=-90(F) U=-90(F) V=-90(F) W=-90(F) X=-90(F) Y=-90(F) Z=-90(F)
AA=-90(F) AB=-90(F) AC=-90(F) AD=-90(F) AE=-22(F) AF=-22(F) AG=-22(F) AH=-22(F) AI=-22(F) AJ=-22(F) AK=-22(F) AL=-22(F) AM=-22(F) AN=-22(F) AO=-22(F)
AP=-22(F) AQ=-22(F) AR=-22(F) AS=-22(F) AT=-22(F)
Job
BOH - JAKE SOMMER
Truss
AC01
Truss Type
Diagonal Hip Girder
Qty
3
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:01 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-RD12aoNzPQPmf7moO4F0qnohnguLBPmTkCKjNmzPHKq
Scale = 1:26.7
T1
B1
W1
W3 W2
A
B
C
D E
H G
F
I J
3x4 3x6
1.5x4
1.5x4
3x4
3-0-0
3-0-0
7-5-14
4-5-14
7-7-14
0-2-0
-2-9-15
2-9-15
3-0-0
3-0-0
7-5-14
4-5-14
7-7-14
0-2-0
0-4-73-11-125.66 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.75
0.24
0.15
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.03
-0.04
0.00
0.03
(loc)
G-H
G-H
G
G-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 38 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=669/0-7-6 (min. 0-1-8), G=370/Mechanical
Max HorzB=194(LC 8)
Max UpliftB=-242(LC 8), G=-195(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-511/179
BOT CHORD B-I=-251/358, H-I=-251/358, H-J=-251/358, G-J=-251/358
WEBS C-G=-378/265
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=242,
G=195.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 30 lb down and 100 lb up at 2-0-5,
30 lb down and 100 lb up at 2-0-5, and 66 lb down and 59 lb up at 4-10-4, and 66 lb down and 59 lb up at 4-10-4 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-E=-84, B-F=-14
Concentrated Loads (lb)
Vert: I=56(F=28, B=28) J=-105(F=-53, B=-53)
Job
BOH - JAKE SOMMER
Truss
AC02
Truss Type
Diagonal Hip Girder
Qty
2
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:02 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-vQbQn8ObAkXdHGL_ynmFM_KsX4Diwsgdys4HwDzPHKp
Scale = 1:27.2
T1
B1
W3
W1
W2
A
B
C
D E
H G
F
I J
3x4
3x4
1.5x4 4x6
1.5x4
3-0-0
3-0-0
7-8-11
4-8-11
7-10-11
0-2-0
-2-9-15
2-9-15
3-0-0
3-0-0
7-8-11
4-8-11
7-10-11
0-2-0
0-4-74-1-25.66 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.75
0.30
0.17
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.04
-0.05
0.00
0.04
(loc)
G-H
G-H
G
G-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 39 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=689/0-7-6 (min. 0-1-8), G=397/Mechanical
Max HorzB=199(LC 8)
Max UpliftB=-234(LC 8), G=-207(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-542/190
BOT CHORD B-I=-266/386, H-I=-266/386, H-J=-266/386, G-J=-266/386
WEBS C-G=-405/280
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=234,
G=207.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 21 lb down and 78 lb up at 2-3-2, 21
lb down and 78 lb up at 2-3-2, and 73 lb down and 66 lb up at 5-1-1, and 73 lb down and 66 lb up at 5-1-1 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-E=-84, B-F=-14
Concentrated Loads (lb)
Vert: I=51(F=26, B=26) J=-125(F=-63, B=-63)
Job
BOH - JAKE SOMMER
Truss
AC03
Truss Type
Diagonal Hip Girder
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:03 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-Nc8p?UPDx1fUuQwBVVHUvCt2MTaRfL3mBWpqSfzPHKo
Scale = 1:21.1
T1
B1
W1
A
B
C
D
F
E
G
2x4
3x4
1.5x4
5-2-3
5-2-3
-2-9-15
2-9-15
5-0-3
5-0-3
5-2-3
0-2-0
0-4-72-9-125.66 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.68
0.20
0.03
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
0.03
0.04
0.00
-0.03
(loc)
B-F
B-F
B-F
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 22 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-2-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=544/0-3-14 (min. 0-1-8), F=156/Mechanical
Max HorzB=147(LC 8)
Max UpliftB=-177(LC 8), F=-87(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) F except (jt=lb) B=177.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 22 lb down and 64 lb up at 2-4-9,
and 22 lb down and 64 lb up at 2-4-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-84, B-E=-14
Concentrated Loads (lb)
Vert: G=48(F=24, B=24)
Job
BOH - JAKE SOMMER
Truss
B01GD
Truss Type
Half Hip Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:06 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-oBqxdVR6Ey23lufmBdrCXqVe_hZ3sb0CtU2U3_zPHKl
Scale = 1:58.2
T1
T2
T1
B1
W5 W4 W2 W2 W1
W5W2W3 W1
B2 B3
T3
A
B
C D E F G
H
I
N M L K J
O P Q R S
T U V W X
5x6
4x4
7x10 4x4
3x4 3x4
7x10 4x4
5x8
2x4
4x4
5x6
5-7-8
5-7-8
10-8-2
5-0-10
14-11-4
4-3-2
20-3-12
5-4-8
25-6-8
5-2-12
31-2-0
5-7-8
-2-0-0
2-0-0
5-7-8
5-7-8
10-8-2
5-0-10
14-11-4
4-3-2
20-3-12
5-4-8
25-6-8
5-2-12
31-2-0
5-7-8
33-2-0
2-0-0
0-4-73-11-104-1-70-4-73-11-108.00 12
Plate Offsets (X,Y)-- [C:0-3-0,0-2-3], [E:0-4-0,0-3-0], [G:0-3-0,0-2-3], [K:0-5-0,0-4-8], [M:0-5-0,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.34
0.33
0.46
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.18
-0.26
0.07
0.13
(loc)
L
K-L
H
L
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 344 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-9-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size) B=2472/0-5-8 (min. 0-1-8), H=2916/0-5-8 (min. 0-1-9)
Max HorzB=133(LC 28)
Max UpliftB=-601(LC 5), H=-905(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3691/1008, C-D=-2878/845, D-E=-5088/1559, E-O=-5647/1908, O-P=-5647/1908,
P-Q=-5647/1908, F-Q=-5647/1908, F-R=-3520/1251, R-S=-3516/1250, G-S=-3515/1249,
G-H=-4476/1501
BOT CHORD B-N=-859/2940, M-N=-1557/5088, L-M=-2010/6339, L-T=-2010/6339, T-U=-2010/6339,
U-V=-2010/6339, K-V=-2010/6339, K-W=-1876/5647, W-X=-1876/5647, J-X=-1876/5647,
H-J=-1177/3592
WEBS C-N=-471/1645, D-N=-2755/944, D-M=-381/1139, F-K=-7/630, F-J=-2621/869, G-J=-605/1936,
E-L=-186/976, E-M=-1674/640, E-K=-866/162
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=601,
H=905.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 128 lb down and 124 lb up at
15-5-12, 128 lb down and 124 lb up at 17-5-12, 128 lb down and 124 lb up at 19-5-12, 128 lb down and 124 lb up at 21-5-12, and 128
lb down and 124 lb up at 23-5-12, and 131 lb down and 127 lb up at 25-6-8 on top chord, and 885 lb down and 256 lb up at 14-11-4,
57 lb down at 15-5-12, 57 lb down at 17-5-12, 57 lb down at 19-5-12, 57 lb down at 21-5-12, and 57 lb down at 23-5-12, and 401 lb
down and 218 lb up at 25-5-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) StandardContinued on page 2
Job
BOH - JAKE SOMMER
Truss
B01GD
Truss Type
Half Hip Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:06 2021 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-oBqxdVR6Ey23lufmBdrCXqVe_hZ3sb0CtU2U3_zPHKl
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-C=-84, C-G=-84, G-I=-84, B-H=-14
Concentrated Loads (lb)
Vert: J=-401(B) L=-885(B) G=-98(B) O=-98(B) P=-98(B) Q=-98(B) R=-98(B) S=-98(B) T=-23(B) U=-23(B) V=-23(B) W=-23(B) X=-23(B)
Job
BOH - JAKE SOMMER
Truss
B02
Truss Type
Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:07 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-GNOJqrSk_GAwN2EykKMR322h15ufb28M68n2bQzPHKk
Scale = 1:57.3
T1
T2
T1
B1
W3 W2 W1 W2 W3
B1
A
B
C D E
F
GJIH
6x8 6x8
4x6
1.5x4 5x8
1.5x4
1.5x4
4x6
7-7-8
7-7-8
15-7-0
7-11-8
23-6-8
7-11-8
31-2-0
7-7-8
-2-0-0
2-0-0
7-7-8
7-7-8
15-7-0
7-11-8
23-6-8
7-11-8
31-2-0
7-7-8
33-2-0
2-0-0
0-4-75-3-105-5-70-4-75-3-108.00 12
Plate Offsets (X,Y)-- [B:0-0-0,0-0-4], [C:0-5-5,Edge], [E:0-5-5,Edge], [F:0-0-0,0-0-4], [I:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.89
0.44
0.47
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.15
-0.22
0.07
0.09
(loc)
I
I-J
F
B-J
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 140 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=1699/0-5-8 (min. 0-1-13), F=1699/0-5-8 (min. 0-1-13)
Max HorzB=167(LC 7)
Max UpliftB=-269(LC 8), F=-269(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2233/340, C-D=-2379/453, D-E=-2379/453, E-F=-2233/340
BOT CHORD B-J=-323/1689, I-J=-325/1685, H-I=-203/1685, F-H=-201/1689
WEBS C-J=0/284, C-I=-298/960, D-I=-799/311, E-I=-298/960, E-H=0/284
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=269,
F=269.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
B03
Truss Type
Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:09 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-CmW4FXU_WtQecLNKslOv8T74JuXa3xvfZSG8gJzPHKi
Scale = 1:57.3
T1
T2
T1
B1
W4
W3 W2 W1 W2 W3
W4
B1
A
B
C
D E F
G
H
IL K J
M N O P Q R
5x8 5x8
4x6
3x4
1.5x4
5x8
1.5x4
3x4
1.5x4
4x6
9-7-8
9-7-8
15-7-0
5-11-8
21-6-8
5-11-8
31-2-0
9-7-8
-2-0-0
2-0-0
7-5-2
7-5-2
9-7-8
2-2-6
15-7-0
5-11-8
21-6-8
5-11-8
23-8-14
2-2-6
31-2-0
7-5-2
33-2-0
2-0-0
0-4-76-7-106-9-70-4-76-7-108.00 12
Plate Offsets (X,Y)-- [B:Edge,0-0-4], [D:0-4-0,0-1-9], [F:0-4-0,0-1-9], [H:Edge,0-0-4], [K:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.59
0.60
0.46
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.24
-0.38
0.07
0.08
(loc)
B-L
B-L
H
B-L
l/defl
>999
>977
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 158 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-5-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) H=1699/0-5-8 (min. 0-1-13), B=1699/0-5-8 (min. 0-1-13)
Max HorzB=202(LC 7)
Max UpliftH=-290(LC 9), B=-290(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2215/291, C-D=-1998/348, D-E=-1884/278, E-F=-1884/278, F-G=-1998/348,
G-H=-2215/291
BOT CHORD B-M=-287/1717, M-N=-287/1717, L-N=-287/1717, L-O=-245/1593, K-O=-245/1593,
K-P=-142/1593, J-P=-142/1593, J-Q=-111/1717, Q-R=-111/1717, H-R=-111/1717
WEBS C-L=-390/252, D-L=-173/694, D-K=-206/586, E-K=-623/229, F-K=-207/586, F-J=-173/695,
G-J=-390/252
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) H=290,
B=290.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
B04
Truss Type
Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:11 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-89dqgDVF2UgMsfXjzAQNEuCQsiEgXsFx1mlFkBzPHKg
Scale = 1:58.2
T2
T3
T2
B2
W4 W3
W2 W2
W3 W4T1 T1
B3B1
W1W1
A
B
C
D E F
G
H
I
M L K J
N O
5x8
5x6 5x6
5x8
6x8 6x8 1.5x4 1.5x4
3x6 3x6
3x4
7-5-2
7-5-2
11-7-8
4-2-6
19-6-8
7-11-0
23-8-14
4-2-6
31-2-0
7-5-2
-2-0-0
2-0-0
7-5-2
7-5-2
11-7-8
4-2-6
15-7-0
3-11-8
19-6-8
3-11-8
23-8-14
4-2-6
31-2-0
7-5-2
33-2-0
2-0-0
0-4-77-11-108-1-70-4-77-11-108.00 12
Plate Offsets (X,Y)-- [B:0-6-0,0-0-6], [C:0-4-0,0-3-0], [D:0-3-0,0-2-3], [F:0-3-0,0-2-3], [G:0-4-0,0-3-0], [H:0-6-0,0-0-6], [K:0-2-12,Edge], [L:0-2-12,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.58
0.50
0.40
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.22
-0.33
0.07
0.07
(loc)
K-L
K-L
H
B-M
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 170 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-5-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt E-K, E-L
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) H=1699/0-5-8 (min. 0-1-13), B=1699/0-5-8 (min. 0-1-13)
Max HorzB=237(LC 7)
Max UpliftH=-308(LC 9), B=-308(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2222/318, C-D=-1797/334, D-E=-1393/304, E-F=-1405/302, F-G=-1778/326,
G-H=-2222/318
BOT CHORD B-M=-256/1755, L-M=-256/1753, L-N=-165/1487, N-O=-165/1487, K-O=-165/1487,
J-K=-109/1686, H-J=-109/1688
WEBS C-L=-544/248, D-L=-120/748, F-K=-116/737, G-K=-550/247, E-K=-391/176, E-L=-401/177
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) H=308,
B=308.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
B05
Truss Type
Hip
Qty
2
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:13 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-5Xla5uXVa6w35zh65bTrJJHn?Vx1?hPEU4EMp4zPHKe
Scale = 1:59.4
T2
T3
T2
B2
W4 W3
W2
W1
W2
W3 W4T1 T1
B3B1
A
B
C
D E
F
G
H
L K J I
M
5x8
5x8 5x6
5x8
5x6 5x8 1.5x4 1.5x4
3x6 3x6
7-5-2
7-5-2
13-7-8
6-2-6
17-6-8
3-11-0
23-8-14
6-2-6
31-2-0
7-5-2
-2-0-0
2-0-0
7-5-2
7-5-2
13-7-8
6-2-6
17-6-8
3-11-0
23-8-14
6-2-6
31-2-0
7-5-2
33-2-0
2-0-0
0-4-79-3-109-5-70-4-79-3-108.00 12
Plate Offsets (X,Y)-- [B:0-6-0,0-0-6], [C:0-4-0,0-3-4], [D:0-4-0,0-1-9], [E:0-3-0,0-2-3], [F:0-4-0,0-3-4], [G:0-6-0,0-0-6], [J:0-2-12,0-3-0], [K:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.54
0.44
0.74
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.12
-0.18
0.07
0.06
(loc)
B-L
B-L
G
B-L
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 169 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-8-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt D-J
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) G=1699/0-5-8 (min. 0-1-13), B=1699/0-5-8 (min. 0-1-13)
Max HorzB=-272(LC 6)
Max UpliftG=-322(LC 9), B=-322(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2234/344, C-D=-1658/323, D-E=-1242/325, E-F=-1651/320, F-G=-2234/344
BOT CHORD B-L=-305/1847, K-L=-305/1844, K-M=-92/1310, J-M=-92/1310, I-J=-140/1696,
G-I=-139/1698
WEBS C-L=0/254, C-K=-685/277, D-K=-135/594, E-J=-107/556, F-J=-688/277, F-I=0/255
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) G=322,
B=322.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
B06
Truss Type
Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:14 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-ZkJzIEX7LP2wj7GIfI_4rWqxIvIZkF3Ojk_vLWzPHKd
Scale = 1:67.1
T2
T3
T2
B1
W4
W3
W2
W1
W2
W3
W4T1 T1
B3B2
A
B
C
D E
F
G
H
L K J I
6x8
5x8 5x6
6x8
3x6
5x6 3x4 7x10 1.5x4
3x6
7-5-2
7-5-2
14-10-4
7-5-2
16-3-12
1-5-8
23-8-14
7-5-2
31-2-0
7-5-2
-2-0-0
2-0-0
7-5-2
7-5-2
14-10-4
7-5-2
16-3-12
1-5-8
23-8-14
7-5-2
31-2-0
7-5-2
33-2-0
2-0-0
0-4-710-1-810-3-50-4-710-1-88.00 12
Plate Offsets (X,Y)-- [B:0-6-0,0-0-6], [C:0-4-0,Edge], [D:0-4-0,0-1-9], [E:0-3-0,0-2-3], [F:0-4-0,Edge], [G:0-6-0,0-0-6], [J:0-3-0,Edge], [L:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.63
0.36
0.27
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.10
-0.17
0.07
0.06
(loc)
K-L
K-L
G
B-L
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 175 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-9-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt C-K, D-J, F-J
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=1699/0-5-8 (min. 0-1-13), G=1699/0-5-8 (min. 0-1-13)
Max HorzB=-293(LC 6)
Max UpliftB=-330(LC 8), G=-330(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2245/360, C-D=-1590/337, D-E=-1165/333, E-F=-1578/336, F-G=-2244/360
BOT CHORD B-L=-336/1713, K-L=-337/1712, J-K=-82/1162, I-J=-163/1711, G-I=-162/1712
WEBS C-L=0/274, C-K=-676/308, D-K=-132/418, D-J=-301/339, E-J=-151/487, F-J=-679/309,
F-I=0/275
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=330,
G=330.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
B07
Truss Type
Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:16 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-V6RjjwZNt1IeyQQhmj0YwxvHXjyKC_9gA1T0PPzPHKb
Scale = 1:60.8
T2
T3
T4
T5
B1
W5
W7 W6
W1
W2
W4
W6 W3T1 T6
B2
A
B
C
D
E
F
G
H
I
M L K J
N O
5x6
6x8 5x6
5x8
3x6
5x8 1.5x4 3x10 1.5x4
5x8
3x6
7-5-2
7-5-2
13-7-0
6-1-14
19-6-8
5-11-8
23-8-14
4-2-6
31-2-0
7-5-2
-2-0-0
2-0-0
7-5-2
7-5-2
13-7-0
6-1-14
15-6-8
1-11-8
19-6-8
4-0-0
23-8-14
4-2-6
31-2-0
7-5-2
33-2-0
2-0-0
0-4-77-11-109-5-20-4-77-11-108.00 12
Plate Offsets (X,Y)-- [B:0-6-0,0-0-6], [C:0-4-0,0-3-4], [F:0-3-0,0-2-3], [G:0-4-0,0-3-0], [H:0-6-0,0-0-6], [K:0-2-12,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.59
0.47
1.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.15
-0.22
0.07
0.07
(loc)
K-L
K-L
H
H-J
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 176 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T3: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-5-10 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt E-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=1699/0-5-8 (min. 0-1-13), H=1699/0-5-8 (min. 0-1-13)
Max HorzB=274(LC 7)
Max UpliftB=-322(LC 8), H=-357(LC 9)
Max GravB=1705(LC 15), H=1699(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2235/348, C-D=-1666/375, D-E=-1530/376, E-F=-1383/378, F-G=-1767/418,
G-H=-2224/403
BOT CHORD B-M=-308/1887, L-M=-307/1891, L-N=-127/1558, N-O=-127/1558, K-O=-127/1558,
J-K=-166/1689, H-J=-166/1692
WEBS F-K=-124/701, G-K=-570/237, D-L=-332/1402, E-L=-906/330, E-K=-271/106, C-L=-667/272
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=322,
H=357.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
B08
Truss Type
Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:18 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-RVYT8cbePeYMCkZ3u8200M?etWcqgvSzeLy7UHzPHKZ
Scale = 1:60.8
T2
T3
T4
T5
B1
W6
W7
W5 W3
W1
W2 W4
T1
B2
A
B
C
D
E
F
G
H
I
L K JM N
5x8
5x6
6x8 5x6
3x6
5x8 3x10
1.5x4
1.5x4
4x6
7-5-2
7-5-2
13-7-0
6-1-14
21-6-8
7-11-8
31-2-0
9-7-8
-2-0-0
2-0-0
7-5-2
7-5-2
13-7-0
6-1-14
17-6-8
3-11-8
21-6-8
4-0-0
26-4-4
4-9-12
31-2-0
4-9-12
33-2-0
2-0-0
0-4-76-7-109-5-20-4-76-7-108.00 12
Plate Offsets (X,Y)-- [B:0-6-0,0-0-6], [C:0-4-0,0-3-4], [F:0-3-0,0-2-3], [K:0-2-12,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.53
0.53
0.95
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.20
-0.28
0.08
0.07
(loc)
J-K
J-K
H
B-L
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 167 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T3: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-8-6 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=1699/0-5-8 (min. 0-1-13), H=1699/0-5-8 (min. 0-1-13)
Max HorzB=274(LC 7)
Max UpliftB=-322(LC 8), H=-357(LC 9)
Max GravB=1704(LC 15), H=1699(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2231/347, C-D=-1657/374, D-E=-1611/356, E-F=-1539/380, F-G=-1955/394,
G-H=-2274/447
BOT CHORD B-L=-303/1879, K-L=-304/1876, K-M=-171/1812, M-N=-171/1812, J-N=-171/1812,
H-J=-240/1767
WEBS F-J=-87/760, G-J=-307/199, C-K=-664/275, D-K=-288/1365, E-K=-952/328, E-J=-440/138
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=322,
H=357.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
B09
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:19 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-vh6sLybGAygDpu8FRsaFYaXjlwwsPQe7t?hg0kzPHKY
Scale = 1:60.8
T2 T3
T4
T5
B1
W6W5W3
W1
W2
W4
B3B2
T1
A
B
C
D
E
F
G
H
K J IL M
5x8
5x6
6x8 5x6
3x6
7x10 5x8 1.5x4
4x6
7-5-2
7-5-2
13-7-0
6-1-14
23-6-8
9-11-8
31-2-0
7-7-8
-2-0-0
2-0-0
7-5-2
7-5-2
13-7-0
6-1-14
19-6-8
5-11-8
23-6-8
4-0-0
31-2-0
7-7-8
33-2-0
2-0-0
0-4-75-3-109-5-20-4-75-3-108.00 12
Plate Offsets (X,Y)-- [B:0-6-0,0-0-6], [C:0-4-0,0-3-4], [F:0-3-0,0-2-3], [G:0-0-0,0-0-4], [I:0-4-0,0-3-4], [J:0-4-12,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.91
0.67
0.69
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.30
-0.47
0.08
0.09
(loc)
I-J
I-J
G
G-I
l/defl
>999
>788
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 159 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T3: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt E-J
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=1699/0-5-8 (min. 0-1-13), G=1699/0-5-8 (min. 0-1-13)
Max HorzB=274(LC 7)
Max UpliftB=-322(LC 8), G=-357(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2229/349, C-D=-1661/370, D-E=-1631/341, E-F=-1681/395, F-G=-2232/382
BOT CHORD B-K=-304/1864, J-K=-305/1861, J-L=-227/2112, L-M=-227/2112, I-M=-227/2112,
G-I=-143/1717
WEBS F-I=-59/830, C-J=-649/280, D-J=-231/1304, E-J=-1110/373, E-I=-686/165
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=322,
G=357.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
B10GD
Truss Type
Half Hip Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:21 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-s4EcmddWhZxx3BIeZGcjd?dD_kjQtJ?QKJAn5czPHKW
Scale = 1:60.8
T2
T3
T4
T5
B1
W7W5
W1
W4 W3
W2 W6
B2 B3
T1
A
B
C
D
E
F
G
H
L K J I
5x6
5x6
6x12 5x8
3x4
7x10 2x4 7x10 2x4
4x4
7-5-12
7-5-12
13-7-0
6-1-4
21-6-8
7-11-8
25-6-8
4-0-0
28-4-4
2-9-12
31-2-0
2-9-12
-2-0-0
2-0-0
7-5-12
7-5-12
13-7-0
6-1-4
21-6-8
7-11-8
25-6-8
4-0-0
28-4-4
2-9-12
31-2-0
2-9-12
33-2-0
2-0-0
0-4-73-11-109-5-20-4-73-11-108.00 12
Plate Offsets (X,Y)-- [C:0-3-0,0-3-0], [F:0-4-0,0-1-9], [J:0-5-0,0-4-8], [K:0-4-12,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.29
0.22
0.77
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.11
-0.15
0.04
0.06
(loc)
J-K
J-K
G
J
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 372 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T3: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size) B=1915/0-5-8 (min. 0-1-8), G=2745/0-5-8 (min. 0-1-8)
Max HorzB=274(LC 7)
Max UpliftB=-403(LC 8), G=-746(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2624/489, C-D=-2059/518, D-E=-2103/478, E-F=-3978/1007, F-G=-4151/1097
BOT CHORD B-L=-419/2022, K-L=-419/2020, J-K=-804/3953, I-J=-746/3265, G-I=-763/3318
WEBS F-I=-439/1318, E-J=-665/280, D-K=-357/1550, C-K=-589/277, E-K=-2591/826,
F-J=-317/1096
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=403,
G=746.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1262 lb down and 482 lb up at
25-5-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-84, D-E=-84, E-F=-84, F-H=-84, B-G=-14
Continued on page 2
Job
BOH - JAKE SOMMER
Truss
B10GD
Truss Type
Half Hip Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:21 2021 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-s4EcmddWhZxx3BIeZGcjd?dD_kjQtJ?QKJAn5czPHKW
LOAD CASE(S) Standard
Concentrated Loads (lb)
Vert: I=-1262(F)
Job
BOH - JAKE SOMMER
Truss
C01GD
Truss Type
COMMON GIRDER
Qty
1
Ply
3 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:24 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-GfwlPffO_UJVwf1DEP9QFdFd8xZV4gZs0HPRhxzPHKT
Scale = 1:58.7
T2 T2
B1
W7 W4
W3 W2
W1
W2 W3
W5 W6
B1
T1
T3
HW2
HW1
A
B
C
D
E
F
G
H
M L K J I
N O P Q R S T U
6x8
8x12
5x8
6x12
2x4
4x8
3x4
12x12 10x20 MT20HS 7x10
3x6
3x10
4x6
7x10
4-2-0
4-2-0
8-4-0
4-2-0
13-7-0
5-3-0
18-10-0
5-3-0
21-7-0
2-9-0
27-2-0
5-7-0
4-2-0
4-2-0
8-4-0
4-2-0
13-7-0
5-3-0
18-10-0
5-3-0
21-7-0
2-9-0
27-2-0
5-7-0
29-2-0
2-0-0
0-4-79-5-20-4-78.00 12
Plate Offsets (X,Y)-- [A:0-10-10,0-3-4], [A:0-4-10,0-2-8], [B:0-0-8,0-2-0], [C:0-3-12,0-3-0], [D:Edge,0-3-8], [E:0-4-0,0-3-0], [G:0-4-1,0-3-0], [J:0-3-8,0-4-8], [K:0-10-0,0-4-8], [L:0-3-8
,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.74
0.90
0.71
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.31
-0.44
0.14
0.17
(loc)
K-L
K-L
G
J-K
l/defl
>999
>731
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT20HS
Weight: 551 lb FT = 20%
GRIP
220/195
165/146
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W7,W4,W5,W6: 2x4 DF Stud/Std
WEDGE
Right: 2x6 DF SS or 1800F 1.6E
SLIDER Left 2x8 DF 1950F 1.7E or SS -À 4-0-8
BRACING-
TOP CHORD Sheathed or 4-5-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size) G=12247/0-5-8 (min. 0-4-6), A=13653/0-5-8 (min. 0-4-14)
Max HorzA=-260(LC 25)
Max UpliftG=-3005(LC 9), A=-2511(LC 8)
Max GravG=12247(LC 1), A=13734(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-22780/4213, B-C=-20690/4077, C-D=-14244/3095, D-E=-14239/3098, E-F=-18667/4367,
F-G=-20592/4999
BOT CHORD A-N=-3531/18671, M-N=-3531/18671, M-O=-3531/18671, O-P=-3531/18671, L-P=-3531/18671,
L-Q=-3341/17078, Q-R=-3341/17078, K-R=-3341/17078, K-S=-3459/15429, S-T=-3459/15429,
J-T=-3459/15429, J-U=-4011/16837, I-U=-4011/16837, G-I=-4011/16837
WEBS B-M=-137/2246, B-L=-1786/208, C-L=-1423/9123, C-K=-7928/1412, D-K=-3284/15202,
E-K=-5401/1738, E-J=-1856/6096, F-J=-2242/964, F-I=-1075/2784
NOTES-
1) Special connection required to distribute bottom chord loads equally between all plies.
2) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-4-0 oc.
Bottom chords connected as follows: 2x6 - 3 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
4) Unbalanced roof live loads have been considered for this design.
5) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
6) All plates are MT20 plates unless otherwise indicated.
7) The Fabrication Tolerance at joint K = 16%
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) G=3005
, A=2511.
Continued on page 2
Job
BOH - JAKE SOMMER
Truss
C01GD
Truss Type
COMMON GIRDER
Qty
1
Ply
3 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:24 2021 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-GfwlPffO_UJVwf1DEP9QFdFd8xZV4gZs0HPRhxzPHKT
NOTES-
11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 963 lb down and 90 lb up at 2-0-4, 975 lb down and 88 lb up at 4-0-4, 975
lb down and 88 lb up at 5-2-4, 975 lb down and 88 lb up at 6-4-12, 5022 lb down and 1043 lb up at 8-4-0, 1952 lb down and 264 lb up at 9-7-12, 1995 lb down and 240 lb up
at 11-7-12, 2014 lb down and 471 lb up at 13-7-12, 1995 lb down and 475 lb up at 15-7-12, 1984 lb down and 479 lb up at 17-7-12, and 1914 lb down and 482 lb up at
19-7-12, and 3137 lb down and 1242 lb up at 21-7-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-84, D-H=-84, A-G=-14
Concentrated Loads (lb)
Vert: M=-919(F) L=-4791(F) K=-1914(F) I=-3137(F) N=-919(F) O=-919(F) P=-919(F) Q=-1919(F) R=-1910(F) S=-1914(F) T=-1914(F) U=-1914(F)
Job
BOH - JAKE SOMMER
Truss
C02
Truss Type
Common
Qty
2
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:26 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-C11VpLhfW5ZD9zBcMqCuK2K_3lM0Yak9UbuYmqzPHKR
Scale = 1:56.1
T2 T2
B1
W3W2
W1
W3 W2
T1
T3
B1
A
B
C
D
E
FI H G
6x8
4x6
6x8
4x6
1.5x4 5x8 1.5x4
4x6
7-5-2
7-5-2
13-7-0
6-1-14
19-8-14
6-1-14
27-2-0
7-5-2
7-5-2
7-5-2
13-7-0
6-1-14
19-8-14
6-1-14
27-2-0
7-5-2
29-2-0
2-0-0
0-4-79-5-20-4-78.00 12
Plate Offsets (X,Y)-- [A:0-0-0,0-0-4], [B:0-4-0,Edge], [D:0-4-0,Edge], [E:Edge,0-0-4], [H:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.58
0.51
0.74
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.12
-0.20
0.06
0.09
(loc)
A-I
A-I
E
A-I
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 130 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-9-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) A=1300/0-5-8 (min. 0-1-8), E=1511/0-5-8 (min. 0-1-10)
Max HorzA=-261(LC 4)
Max UpliftA=-233(LC 8), E=-299(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-1935/322, B-C=-1323/313, C-D=-1321/316, D-E=-1905/305
BOT CHORD A-I=-291/1460, H-I=-291/1458, G-H=-142/1426, E-G=-142/1427
WEBS D-G=0/251, D-H=-619/281, C-H=-201/856, B-I=0/256, B-H=-663/300
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=233,
E=299.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
C03
Truss Type
Common
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:27 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-gEbt1hiHHPh4n6movXj7tGt9p9iDH0_IiFd5IGzPHKQ
Scale = 1:54.9
T2 T2
B1
W3 W2
W1
W3W2
T1 T1
B1
A
B
C
D
E
H G F
6x8
4x6
6x8
4x6
1.5x4 5x8 1.5x4
4x6
7-5-2
7-5-2
13-7-0
6-1-14
19-8-14
6-1-14
27-2-0
7-5-2
7-5-2
7-5-2
13-7-0
6-1-14
19-8-14
6-1-14
27-2-0
7-5-2
0-4-79-5-20-4-78.00 12
Plate Offsets (X,Y)-- [A:0-0-0,0-0-4], [B:0-4-0,Edge], [D:0-4-0,Edge], [E:Edge,0-0-4], [G:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.58
0.51
0.74
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.12
-0.20
0.06
0.09
(loc)
A-H
A-H
E
A-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 127 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-9-12 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) A=1309/0-5-8 (min. 0-1-8), E=1309/0-5-8 (min. 0-1-8)
Max HorzA=-238(LC 4)
Max UpliftA=-234(LC 8), E=-234(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-1950/325, B-C=-1337/319, C-D=-1337/319, D-E=-1950/325
BOT CHORD A-H=-316/1472, G-H=-316/1471, F-G=-173/1471, E-F=-173/1472
WEBS B-H=0/256, B-G=-663/300, C-G=-205/877, D-F=0/256, D-G=-663/301
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=234,
E=234.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
D01
Truss Type
Roof Special
Qty
2
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:29 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-dcjeSNjXp0xo0QvA1ylbyhyW7yQTlxFbAZ6CN9zPHKO
Scale = 1:55.6
T2
T3
B2
W5
W3 W2
W1
W4
W3W2
B1
T1
A
B
C
D
E
F
J I H G
5x8
4x6
5x6
1.5x4 1.5x4 5x8 4x4
3x6
4x4
7-5-2
7-5-2
13-7-0
6-1-14
19-8-14
6-1-14
25-5-0
5-8-2
-2-0-0
2-0-0
7-5-2
7-5-2
13-7-0
6-1-14
19-8-14
6-1-14
25-5-0
5-8-2
0-4-79-5-21-6-78.00 12
Plate Offsets (X,Y)-- [B:0-0-11,Edge], [C:0-4-0,0-3-4], [I:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.53
0.33
0.69
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.07
-0.13
0.04
0.06
(loc)
B-J
B-J
G
B-J
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 134 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-3-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) G=1218/Mechanical, B=1430/0-5-8 (min. 0-1-8)
Max HorzB=257(LC 5)
Max UpliftG=-208(LC 9), B=-288(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-1762/284, C-D=-1181/290, D-E=-1176/290, E-F=-1446/249, F-G=-1180/227
BOT CHORD B-J=-309/1309, I-J=-310/1308, H-I=-147/1113
WEBS C-I=-619/279, D-I=-168/679, F-H=-135/1050, E-I=-410/229
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) G=208,
B=288.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
E01
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:30 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-5pH0fik9aK3feaUNbfGqVuUdpMgwUNJkPDsmvbzPHKN
Scale = 1:64.8
W5
T1
T3
W1
B1
W6
W5
W4
W3
W2T2
B2
A
B
C
D
H G F
EI
2x4
5x8
7x10
3x4
3x6 6x8 5x6
4x8
4-9-0
4-9-0
12-6-0
7-9-0
20-3-0
7-9-0
4-9-0
4-9-0
12-6-0
7-9-0
20-3-0
7-9-0
1-4-1011-10-71-4-108.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.79
0.70
0.76
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.26
-0.39
0.04
0.11
(loc)
F-G
F-G
E
F-G
l/defl
>905
>607
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 114 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std *Except*
W6: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 3-8-1 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 8-2-2 oc bracing.
WEBS 1 Row at midpt D-E, B-F, C-E
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) H=978/0-5-8 (min. 0-1-8), E=978/Mechanical
Max HorzH=423(LC 8)
Max UpliftH=-107(LC 8), E=-372(LC 8)
Max GravH=978(LC 1), E=1113(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-H=-919/113, A-B=-2872/221, B-C=-1145/0
BOT CHORD G-H=-439/218, F-G=-671/3102, F-I=-296/924, E-I=-296/924
WEBS A-G=-209/2829, B-G=-677/118, B-F=-2232/380, C-F=0/644, C-E=-1201/383
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) H=107,
E=372.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
E02
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:32 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-1BPm4OlQ6xJNtueli4IIaJa0gAPRyEE1sXLs_TzPHKL
Scale: 3/16"=1'
W5
T1
T3
B1
W6
W5
W4
W3
W2
W1T2
B2
A
B
C
D
H G F EI
2x4
7x10
7x10
3x6
5x8 4x6
4x8
3x6
5-11-8
5-11-8
13-1-4
7-1-12
20-3-0
7-1-12
5-11-8
5-11-8
13-1-4
7-1-12
19-11-0
6-9-12
20-3-0
0-4-0
2-2-511-7-1311-5-22-2-58.00 12
Plate Offsets (X,Y)-- [D:0-3-8,Edge], [G:0-2-12,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.64
0.51
0.93
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.14
-0.21
0.03
0.06
(loc)
F-G
F-G
E
F-G
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 117 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-10-5 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 9-2-1 oc bracing.
WEBS 1 Row at midpt B-F, D-E, C-E
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) H=978/0-5-8 (min. 0-1-8), E=978/Mechanical
Max HorzH=390(LC 8)
Max UpliftH=-109(LC 8), E=-370(LC 8)
Max GravH=978(LC 1), E=1104(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-H=-930/127, A-B=-2084/138, B-C=-1028/0
BOT CHORD G-H=-407/169, F-G=-533/2147, F-I=-263/812, E-I=-263/812
WEBS A-G=-125/2098, B-G=-597/100, B-F=-1444/281, C-F=-7/658, C-E=-1126/364
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) H=109,
E=370.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
E03
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:33 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-VNy8Hkm2tFREV1DyGoqX7X66ZZm8hjwB5B4QWwzPHKK
Scale: 3/16"=1'
W5
T1
T2
B1
W6 W5
W4
W3
W1
W2
B2
A
B
C
D
H G F EI
2x4
5x6 4x12
3x6
5x6 3x4
3x6
3x6
6-11-8
6-11-8
13-7-4
6-7-12
20-3-0
6-7-12
6-11-8
6-11-8
13-7-4
6-7-12
19-11-0
6-3-12
20-3-0
0-4-0
2-10-511-7-1311-5-22-10-58.00 12
Plate Offsets (X,Y)-- [D:0-3-8,Edge], [G:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.95
0.41
0.77
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.10
-0.14
0.02
0.04
(loc)
F-G
F-G
E
F-G
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 120 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-3-12 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 9-10-6 oc bracing.
WEBS 1 Row at midpt B-F, C-E, D-E
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) H=978/0-5-8 (min. 0-1-8), E=978/Mechanical
Max HorzH=363(LC 8)
Max UpliftH=-112(LC 8), E=-367(LC 8)
Max GravH=978(LC 1), E=1093(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-H=-927/135, A-B=-1713/95, B-C=-941/0
BOT CHORD G-H=-382/156, F-G=-462/1741, F-I=-239/734, E-I=-239/734
WEBS A-G=-80/1743, B-G=-542/91, B-F=-1156/240, C-F=-27/673, C-E=-1076/350
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) H=112,
E=367.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
E04
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:34 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-zaWXV4ngeZZ56Bo8qVLmfkfPVz79QCGKJrqz2MzPHKJ
Scale = 1:64.7
W5
T1
T2
B1
W6 W6 W5 W4
W3
W2
W1
B2
A
B
C
D
E
I H G
FJ
3x6
1.5x4 4x8
1.5x4
5x6
3x4
3x4
3x6
3x6
8-9-0
8-9-0
14-3-12
5-6-12
19-10-8
5-6-12
4-4-8
4-4-8
8-9-0
4-4-8
14-3-12
5-6-12
19-6-8
5-2-12
19-10-8
0-4-0
4-3-1011-7-1311-5-24-3-108.00 12
Plate Offsets (X,Y)-- [E:0-2-0,0-0-11], [H:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.43
0.36
0.70
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.14
-0.23
0.02
0.02
(loc)
H-I
H-I
F
H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 129 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt E-F, D-F
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) I=960/0-5-8 (min. 0-1-8), F=960/Mechanical
Max HorzI=304(LC 8)
Max UpliftI=-115(LC 8), F=-355(LC 8)
Max GravI=960(LC 1), F=1046(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-1173/27, C-D=-738/0
BOT CHORD H-I=-396/814, G-H=-329/1176, G-J=-186/552, F-J=-186/552
WEBS B-I=-1096/130, B-H=0/558, C-G=-812/178, D-G=-59/667, D-F=-962/324
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) I=115,
F=355.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
E05
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:36 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-wyeHwmpw9AppMVyXxwNEk9kjVnmeu7hdn9J47FzPHKH
Scale: 3/16"=1'
W5
T1
T2
B1
W4
W5 W4 W3
W2
B2
W1
A B
C
D
H G F
EI
3x4
2x4 5x8
2x4
5x8
3x10
1.5x4 3x6
5-6-4
5-6-4
10-9-0
5-2-12
19-10-8
9-1-8
5-6-4
5-6-4
10-9-0
5-2-12
19-6-8
8-9-8
19-10-8
0-4-0
5-7-1011-7-130-3-85-7-108.00 12
Plate Offsets (X,Y)-- [C:0-6-4,0-2-4], [F:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.52
0.49
0.58
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.22
-0.36
0.02
0.02
(loc)
E-F
E-F
E
F
l/defl
>999
>658
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 134 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T2: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt B-H, D-E, C-E
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) H=960/0-5-8 (min. 0-1-8), E=960/Mechanical
Max HorzH=245(LC 8)
Max UpliftH=-152(LC 4), E=-340(LC 8)
Max GravH=960(LC 1), E=1001(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-956/37, C-D=-250/160
BOT CHORD G-H=-322/744, F-G=-322/744, F-I=-263/958, E-I=-263/958
WEBS B-H=-1028/146, B-F=0/337, D-E=-352/213, C-E=-1116/306
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) H=152,
E=340.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
E06
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:37 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-O9Cf76pYwUyfzfWjVeuTHNHxNBAHdUfm0p2dfhzPHKG
Scale = 1:67.4
W7
T1
T2
B1
W6 W7 W6 W5
W2
B2
W4
W3
W1
A B
C
D
E
K J I H G
FL
3x4
2x4
5x6
3x4
3x10
1.5x4
3x4 3x6
4x12
3x4
3x6
5-4-0
5-4-0
10-4-8
5-0-8
15-1-8
4-9-0
19-10-8
4-9-0
5-4-0
5-4-0
10-4-8
5-0-8
15-1-8
4-9-0
19-6-8
4-5-0
19-10-8
0-4-0
5-4-1011-7-130-3-85-4-108.00 12
Plate Offsets (X,Y)-- [E:0-1-12,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.32
0.21
0.98
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.04
-0.06
0.02
0.02
(loc)
H-I
H-I
F
H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 143 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt E-F, D-F
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) K=960/0-5-8 (min. 0-1-8), F=960/Mechanical
Max HorzK=259(LC 8)
Max UpliftK=-145(LC 4), F=-345(LC 8)
Max GravK=960(LC 1), F=1015(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-934/43, C-D=-617/2
BOT CHORD J-K=-336/771, I-J=-336/771, H-I=-336/771, G-H=-269/928, G-L=-149/444, F-L=-149/444
WEBS B-K=-1061/133, B-H=0/260, C-G=-734/177, D-G=-86/710, D-F=-923/309
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) K=145,
F=345.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
E07
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:39 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-KXKQYnrpS5CNDyg5c2xxMoMGq_qd5S_3T6XkjZzPHKE
Scale: 3/16"=1'
W6
T1
T2
T3
W3
B1
W7 W7 W6 W5
W4
W1 W2
A
B
C
D
E F
J I H GK L
3x6
1.5x4 4x8
5x8 1.5x4
3x6
3x4
3x4
1.5x4
4x8
8-4-8
8-4-8
14-1-8
5-9-0
19-10-8
5-9-0
4-2-4
4-2-4
8-4-8
4-2-4
14-1-8
5-9-0
18-11-0
4-9-8
19-10-8
0-11-8
4-0-1011-1-011-2-1311-1-08.00 12
Plate Offsets (X,Y)-- [E:0-4-0,0-1-9]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.39
0.34
0.73
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.11
-0.20
0.02
0.03
(loc)
I-J
I-J
G
H-I
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 144 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-11-3 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt F-G, E-H, E-G
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) J=960/0-5-8 (min. 0-1-8), G=960/Mechanical
Max HorzJ=287(LC 8)
Max UpliftJ=-128(LC 8), G=-328(LC 8)
Max GravJ=960(LC 1), G=1031(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-1231/67, C-D=-764/0, D-E=-766/177
BOT CHORD I-J=-395/837, H-I=-354/1238
WEBS B-J=-1118/150, B-I=0/607, C-I=-256/27, C-H=-846/196, D-H=-495/306, E-H=-400/1208,
E-G=-936/366
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) J=128,
G=328.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
E08
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:40 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-oktom7sRDPKEq6FIAmSAv?vJLO9XquHDimHHG0zPHKD
Scale = 1:57.0
W6
T1
T2
T3
W3
B1
W7 W6
W5
W4
W1
W2
B2
A
B
C
D E
I H G FJ K
2x4
5x8 6x8
7x10 1.5x4
3x6 5x6
2x4
4x8
6-11-0
6-11-0
13-7-0
6-8-0
20-3-0
6-8-0
6-11-0
6-11-0
13-7-0
6-8-0
17-5-8
3-10-8
20-3-0
2-9-8
2-10-09-10-510-0-29-10-58.00 12
Plate Offsets (X,Y)-- [D:0-5-0,0-2-0], [H:0-2-12,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.92
0.43
0.79
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.11
-0.15
0.02
0.05
(loc)
G-H
G-H
F
G-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 141 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T2: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-5-15 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 9-7-1 oc bracing.
WEBS 1 Row at midpt E-F, B-G, D-F
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) I=978/0-5-8 (min. 0-1-8), F=978/Mechanical
Max HorzI=287(LC 8)
Max UpliftI=-149(LC 8), F=-283(LC 8)
Max GravI=978(LC 1), F=1013(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-I=-927/172, A-B=-1765/195, B-C=-941/44, C-D=-942/238
BOT CHORD H-I=-307/139, G-H=-489/1797
WEBS A-H=-187/1800, B-H=-562/130, B-G=-1221/283, C-G=-516/317, D-G=-386/1255, D-F=-883/300
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) I=149,
F=283.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
E09
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:42 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-k6?YApthl0ay4QPgIBUe_Q_kkCm1Ip4V94mOKuzPHKB
Scale = 1:48.7
W6
T1
T2
T3
W5
B1W7W6 W4
W3
B2
W2
W1
A
B
C
D E
I H G FJ K
2x4
5x8 6x8
6x8 1.5x4
3x6 7x10 5x8
2x4
4-11-0
4-11-0
12-7-0
7-8-0
20-3-0
7-8-0
4-11-0
4-11-0
12-7-0
7-8-0
15-5-8
2-10-8
20-3-0
4-9-8
1-6-08-6-58-8-28-6-58.00 12
Plate Offsets (X,Y)-- [D:0-4-0,0-2-4], [G:0-4-12,Edge], [H:0-3-8,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.54
0.68
0.71
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.24
-0.35
0.04
0.12
(loc)
G-H
G-H
F
G-H
l/defl
>999
>680
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 129 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T2: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std *Except*
W7: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 3-6-14 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 7-11-9 oc bracing.
WEBS 1 Row at midpt E-F, B-G, D-F
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) I=978/0-5-8 (min. 0-1-8), F=978/Mechanical
Max HorzI=287(LC 8)
Max UpliftI=-162(LC 8), F=-235(LC 8)
Max GravI=978(LC 1), F=997(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-I=-919/170, A-B=-2826/402, B-C=-1095/97, C-D=-1182/323
BOT CHORD H-I=-314/194, G-H=-708/2908, G-J=-129/438, J-K=-129/438, F-K=-129/438
WEBS A-H=-388/2768, B-H=-667/163, B-G=-2120/456, C-G=-612/374, D-F=-873/264, D-G=-401/1331
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) I=162,
F=235.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
G01
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:44 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-hV7JbVvxHdqgJkZ3PcW63r40J?W3mmIodOFVPnzPHK9
Scale = 1:60.4
W6
T1
T2
T3
W4
B1
W7 W6
W5
W3 W1 W2
B2
A
B
C
D E
I H G F
J K L
1.5x4
5x6 6x8
7x10
1.5x4 6x8
4x4
4x8
5x6
6-6-8
6-6-8
15-3-8
8-9-0
19-4-0
4-0-8
6-6-8
6-6-8
10-11-0
4-4-8
15-3-8
4-4-8
19-4-0
4-0-8
4-7-010-5-010-6-1310-5-08.00 12
Plate Offsets (X,Y)-- [D:0-7-5,Edge], [H:0-2-12,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.79
0.39
0.54
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.18
-0.26
0.01
0.03
(loc)
G-H
G-H
F
G-H
l/defl
>999
>870
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 147 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T2: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-3-15 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt E-F, C-G, D-G
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) I=933/0-5-8 (min. 0-1-8), F=933/Mechanical
Max HorzI=238(LC 8)
Max UpliftI=-131(LC 8), F=-257(LC 8)
Max GravI=936(LC 2), F=975(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-I=-894/150, A-B=-1012/86, B-C=-1299/182, C-D=-482/63, D-E=-336/96, E-F=-937/263
BOT CHORD H-J=-235/654, J-K=-235/654, G-K=-235/654
WEBS A-H=-91/1182, B-H=-1115/271, C-H=-172/761, C-G=-631/277, E-G=-256/901
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) I=131,
F=257.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
G02
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:45 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-9hhhprwZ2xyXxt8FzJ1Lc3cHkPrNV8Zyr2_2xDzPHK8
Scale = 1:67.1
W5
T1
T2
T3
W4
B1
W6 W6 W5
W1
W2
W3
B2
A
B
C
D E
I H G FJ K L
4x4
1.5x4 5x8
6x8 1.5x4
3x6 5x8
3x4
3x4
8-6-8
8-6-8
17-3-8
8-9-0
19-4-0
2-0-8
4-3-4
4-3-4
8-6-8
4-3-4
17-3-8
8-9-0
19-4-0
2-0-8
5-11-011-9-011-10-1311-9-08.00 12
Plate Offsets (X,Y)-- [D:0-4-0,0-2-8], [H:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.43
0.45
0.79
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.15
-0.22
0.02
0.03
(loc)
H-I
H-I
F
G-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 155 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T2: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt E-F, D-F, C-G
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) I=933/0-5-8 (min. 0-1-8), F=933/Mechanical
Max HorzI=238(LC 8)
Max UpliftI=-120(LC 8), F=-304(LC 8)
Max GravI=957(LC 2), F=951(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-866/37, C-D=-405/13
BOT CHORD I-J=-303/549, J-K=-303/549, H-K=-303/549, H-L=-276/868, G-L=-276/868
WEBS B-I=-910/110, B-H=0/555, D-G=-75/660, D-F=-1068/353, C-G=-830/260
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) I=120,
F=304.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
G03
Truss Type
Piggyback Base
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:47 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-54pREWxqaYCFABHe4k4phUib_DZvz6WEJMT9?6zPHK6
Scale = 1:68.1
T1
T2
T3
T4
W2
B1
W6
W5
W5 W4
W1
W2
W3
W8
W7
B2
A
B
C
D
E F
K J I H
GL M N
5x6 4x8
1.5x4
3x6 1.5x4 5x8 4x8
3x4
3x4
4x8
5x6
1-11-8
1-11-8
10-6-8
8-7-0
16-8-5
6-1-13
19-4-0
2-7-11
1-11-8
1-11-8
6-1-4
4-1-12
10-6-8
4-5-4
16-8-5
6-1-13
19-4-0
2-7-11
6-1-27-3-011-6-08.00 12
Plate Offsets (X,Y)-- [B:0-3-0,0-2-3], [E:0-6-4,0-2-4], [I:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.57
0.38
0.57
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.15
-0.22
0.01
0.02
(loc)
I-J
I-J
G
H-I
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 167 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: J-K.
WEBS 1 Row at midpt F-G, C-J, D-H, E-G
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) G=933/Mechanical, K=933/0-5-8 (min. 0-1-8)
Max HorzK=218(LC 8)
Max UpliftG=-285(LC 8), K=-128(LC 8)
Max GravG=953(LC 2), K=963(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-313/48, C-D=-704/53, D-E=-371/18, A-K=-1051/104
BOT CHORD J-L=-274/571, L-M=-274/571, I-M=-274/571, I-N=-225/700, H-N=-225/700
WEBS C-J=-649/117, C-I=0/274, D-H=-762/238, E-H=-134/690, E-G=-918/308, A-J=-66/885
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) G=285,
K=128.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
G04
Truss Type
Piggyback Base
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:49 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-1SwBeCz45ASyQVR0C96Hmvnw60DpRzFXmgyG4_zPHK4
Scale = 1:66.1
T1
T2
T3
T4
W3
B1
W6
W5 W5
W4
W1
W8
W7
B2
W2A
B
C
D
E F
K J I H GL M N O
5x6 6x8
8x12 1.5x4
3x6 1.5x4 3x4 3x10
3x4
4x8
5x6
3-11-8
3-11-8
12-6-8
8-7-0
19-4-0
6-9-8
3-11-8
3-11-8
8-1-4
4-1-12
12-6-8
4-5-4
16-8-5
4-1-13
19-4-0
2-7-11
6-1-28-7-011-6-08.00 12
Plate Offsets (X,Y)-- [B:0-3-0,0-2-3], [E:0-10-4,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.59
0.42
0.75
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.16
-0.23
0.01
0.02
(loc)
H-J
H-J
G
H-J
l/defl
>999
>988
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 168 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T3: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt F-G, B-J, C-J, C-H, D-H, E-G
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) G=933/Mechanical, K=933/0-5-8 (min. 0-1-8)
Max HorzK=217(LC 8)
Max UpliftG=-284(LC 8), K=-129(LC 8)
Max GravG=988(LC 2), K=957(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-510/92, B-C=-376/123, C-D=-547/53, D-E=-754/151, A-K=-953/132
BOT CHORD J-L=-245/546, I-L=-245/546, I-M=-245/546, H-M=-245/546
WEBS C-J=-402/111, D-H=-690/213, E-H=-302/1033, A-J=-61/697, E-G=-837/303
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) G=284,
K=129.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
G05
Truss Type
Piggyback Base
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:51 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-_r2y3u_KdnigfobPJa8lrKsBFqvivu1qE_RN9tzPHK2
Scale = 1:68.7
T1
T2
T3
T4
W4
B1
W6
W5 W5
W3
W1
W8
W7
B2
W2A
B
C
D
E F
K J I H GL M N O
5x6 6x8
8x12 1.5x4
3x6 1.5x4 3x4
3x10
3x4
4x8
5x6
5-11-8
5-11-8
14-6-8
8-7-0
19-4-0
4-9-8
5-11-8
5-11-8
10-1-4
4-1-12
14-6-8
4-5-4
16-8-5
2-1-13
19-4-0
2-7-11
6-1-29-11-011-6-08.00 12
Plate Offsets (X,Y)-- [B:0-3-0,0-2-3], [E:0-10-4,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.94
0.39
0.66
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.19
-0.26
0.01
0.02
(loc)
H-I
H-I
G
H-I
l/defl
>999
>870
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 173 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T3: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt F-G, B-I, C-I, C-H, D-H, E-G
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) G=933/Mechanical, K=933/0-5-8 (min. 0-1-8)
Max HorzK=217(LC 8)
Max UpliftG=-284(LC 8), K=-129(LC 8)
Max GravG=983(LC 2), K=949(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-617/113, B-C=-433/163, C-D=-388/57, D-E=-519/119, A-K=-903/143
BOT CHORD I-L=-205/480, L-M=-205/480, H-M=-205/480
WEBS C-H=-280/207, D-H=-505/168, E-H=-297/987, A-I=-50/598, E-G=-886/287
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) G=284,
K=129.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
G06
Truss Type
Piggyback Base
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:52 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-S1cKHE?yO5qXHyAbtHf_OXPNpEF3eQl_SeBwhJzPHK1
Scale = 1:66.6
T1
T2 T3
W4
B1
W5 W3 W1
W7
W6
W3
W2
B2
A
B C D E
J I H G FK L M
5x8
5x6 2x4
2x4
7x10
1.5x4 2x4 3x4 3x10
3x4
3x10
7-11-8
7-11-8
16-6-8
8-7-0
16-8-5
0-1-13
19-4-0
2-7-11
7-11-8
7-11-8
12-3-15
4-4-7
16-6-8
4-2-9
16-8-5
0-1-13
19-4-0
2-7-11
6-1-211-3-011-6-08.00 12
Plate Offsets (X,Y)-- [A:Edge,0-1-14], [B:0-3-0,0-2-3]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.88
0.45
0.38
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.21
-0.29
0.01
0.02
(loc)
G-H
G-H
F
G-H
l/defl
>999
>785
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 167 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T3: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 2-2-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt E-F, B-H, D-G, C-G
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=933/Mechanical, J=933/Mechanical
Max HorzJ=213(LC 8)
Max UpliftF=-256(LC 5), J=-76(LC 8)
Max GravF=965(LC 2), J=977(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-677/88, B-C=-446/156, E-F=-1022/243, A-J=-886/99
BOT CHORD H-L=-116/387, L-M=-116/387, G-M=-116/387
WEBS B-H=-260/157, D-G=-296/114, A-H=-38/527, C-G=-512/185, E-G=-220/987
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) J except (jt=lb) F=256.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
G07
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:54 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-OQk4iw0Dwi5FWGK_?iiSTyUpi1xK6GTGwyg1lCzPHK?
Scale = 1:65.3
T1
T2
W2
B1
W1
W2 W3 W2
W3
W5
W4
B2
A
B
C D E
I H G
FJ K L M
1.5x4
4x6 1.5x4
3x6 6x8
3x4
1.5x4
3x10
3x6
8-1-5
8-1-5
13-8-11
5-7-5
19-4-0
5-7-5
4-0-11
4-0-11
8-1-5
4-0-11
13-8-11
5-7-5
19-4-0
5-7-5
6-1-211-6-08.00 12
Plate Offsets (X,Y)-- [C:0-4-4,0-2-4], [H:0-2-12,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.47
0.40
0.62
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.18
-0.26
0.01
0.01
(loc)
H-I
H-I
F
G-H
l/defl
>999
>894
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 164 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt E-F, C-H, D-F, B-I
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=933/Mechanical, I=933/Mechanical
Max HorzI=218(LC 8)
Max UpliftF=-255(LC 5), I=-74(LC 8)
Max GravF=997(LC 2), I=989(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-605/129, C-D=-436/149
BOT CHORD I-J=-230/390, J-K=-230/390, H-K=-230/390, H-L=-100/379, G-L=-100/379, G-M=-100/379,
F-M=-100/379
WEBS B-H=-71/272, D-G=0/276, D-F=-854/227, B-I=-815/59
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) I except (jt=lb) F=255.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
G08
Truss Type
Half Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:56 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-Kprr6b2TSJLzlaTN67kwYNZ8rrcaaAyZNG98p4zPHJz
Scale = 1:65.3
T1
T2
W2
B1
W1
W2 W3 W2
W3
W5
W4
B2
A
B
C D E
J I H G
FK L M N
1.5x4
4x6 1.5x4
3x6 3x6 3x10
3x4
1.5x4
3x10
3x6
8-1-5
8-1-5
13-8-11
5-7-5
19-4-0
5-7-5
4-0-11
4-0-11
8-1-5
4-0-11
13-8-11
5-7-5
19-4-0
5-7-5
6-1-211-6-08.00 12
Plate Offsets (X,Y)-- [C:0-4-4,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.50
0.41
0.62
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.20
-0.27
0.01
0.01
(loc)
H-J
H-J
F
G-H
l/defl
>999
>834
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 164 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt E-F, C-H, D-F, B-J
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=933/Mechanical, J=933/Mechanical
Max HorzJ=218(LC 8)
Max UpliftF=-255(LC 5), J=-74(LC 8)
Max GravF=997(LC 2), J=989(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-605/127, C-D=-436/147
BOT CHORD J-K=-230/389, I-K=-230/389, I-L=-230/389, H-L=-230/389, H-M=-101/379, G-M=-101/379,
G-N=-101/379, F-N=-101/379
WEBS B-H=-71/270, D-G=0/269, D-F=-853/227, B-J=-814/60
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) J except (jt=lb) F=255.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
G09
Truss Type
Hip
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:58 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-GBzbXH4j_xbh?tdlEYmOdofULeI224SsraeEtzzPHJx
Scale = 1:65.3
T1
T2
W2
B1
W1
W2 W3 W2
W3
W5
W4
B2
A
B
C D E
J I H G
FK L M N
1.5x4
4x6 1.5x4
3x6 3x6 3x10
3x4
1.5x4
3x10
3x6
8-1-5
8-1-5
13-8-11
5-7-5
19-4-0
5-7-5
4-0-11
4-0-11
8-1-5
4-0-11
13-8-11
5-7-5
19-4-0
5-7-5
6-1-211-6-08.00 12
Plate Offsets (X,Y)-- [C:0-4-4,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.50
0.41
0.62
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.20
-0.27
0.01
0.01
(loc)
H-J
H-J
F
G-H
l/defl
>999
>834
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 164 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt E-F, C-H, D-F, B-J
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=933/Mechanical, J=933/Mechanical
Max HorzJ=218(LC 8)
Max UpliftF=-255(LC 5), J=-74(LC 8)
Max GravF=997(LC 2), J=989(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-605/127, C-D=-436/147
BOT CHORD J-K=-230/389, I-K=-230/389, I-L=-230/389, H-L=-230/389, H-M=-101/379, G-M=-101/379,
G-N=-101/379, F-N=-101/379
WEBS B-H=-71/270, D-G=0/269, D-F=-853/227, B-J=-814/60
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) J except (jt=lb) F=255.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
H01G
Truss Type
Common Structural Gable
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:14:59 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-lOXzld4LlEjYc1CxnFHdA0Bi62gdndA03ENoQPzPHJw
Scale = 1:39.5
T1 T2
B1
W1
W2
W2
ST3
ST4
ST2ST1
ST3
ST4
ST2 ST1
B1
A
B
C
D
E
F
GIJH
4x4
3x4 5x8 3x4
0-11-8
0-11-8
9-0-0
8-0-8
17-0-8
8-0-8
18-0-0
0-11-8
-2-0-0
2-0-0
4-6-0
4-6-0
9-0-0
4-6-0
13-6-0
4-6-0
18-0-0
4-6-0
20-1-0
2-1-0
0-4-76-4-70-4-78.00 12
Plate Offsets (X,Y)-- [I:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.30
0.26
0.21
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.05
-0.09
0.02
0.02
(loc)
I-J
H-I
F
I
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 106 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-11-1 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 1-3-0 except (jt=length) J=0-3-8, H=0-3-8.
(lb) - Max HorzB=-194(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) except B=-291(LC 8), F=-302(LC 9)
Max Grav All reactions 250 lb or less at joint(s) except B=932(LC 1), F=951(LC 1), J=310(LC 3), H=308(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-1208/247, C-D=-868/208, D-E=-868/207, E-F=-1208/248
BOT CHORD B-J=-220/912, I-J=-220/912, H-I=-120/911, F-H=-120/911
WEBS D-I=-104/467, E-I=-354/221, C-I=-355/220
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 291 lb uplift at joint B and 302 lb uplift at joint
F.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
H02
Truss Type
Common
Qty
6
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:01 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-hmfkAJ6cHszFsLMKvgK5FRH2QsLHFXbIXYsvUIzPHJu
Scale = 1:39.3
T1 T1
B1
W1
W2W2
B1
A
B
C
D
E
F
GH
4x4
4x4 5x8
1.5x4 1.5x4
4x4
9-0-0
9-0-0
18-0-0
9-0-0
-2-0-0
2-0-0
4-6-0
4-6-0
9-0-0
4-6-0
13-6-0
4-6-0
18-0-0
4-6-0
20-0-0
2-0-0
0-4-76-4-70-4-78.00 12
Plate Offsets (X,Y)-- [B:0-0-15,0-0-0], [F:0-0-15,0-0-0], [H:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.32
0.38
0.21
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.10
-0.17
0.02
0.02
(loc)
F-H
F-H
F
H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 83 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-11-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=1055/0-3-0 (min. 0-1-8), F=1055/0-3-0 (min. 0-1-8)
Max HorzB=193(LC 7)
Max UpliftB=-218(LC 8), F=-218(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-1209/214, C-D=-875/183, D-E=-875/183, E-F=-1209/215
BOT CHORD B-H=-187/911, F-H=-91/911
WEBS D-H=-73/478, E-H=-348/202, C-H=-348/202
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 218 lb uplift at joint B and 218 lb uplift at joint
F.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
HF1
Truss Type
GABLE
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:02 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-9zD6Nf7E2956TVxWTOrKoepG4Glg__KSlBcS0kzPHJt
Scale = 1:61.6
T1
T2
T3
B1
B3
ST5
ST4
ST3
ST2
ST1
B2
ST6
ST7
ST8
ST9
A
B
C
D
E
F G
H
I
J
K
L
W V U T S R Q P O N M
3x4
3x4
3x4
3x4 3x4
6x8
16-6-5
16-6-5
18-1-13
1-7-8
9-1-15
9-1-15
10-7-7
1-5-8
18-1-13
7-6-7
11-0-21-11-711-0-214.42 12
14.42 12
Plate Offsets (X,Y)-- [F:0-2-11,Edge], [G:0-1-5,Edge], [L:Edge,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.05
0.24
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.01
(loc)
-
-
L
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 133 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt F-R, H-Q
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 18-1-13.
(lb) - Max HorzA=287(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) R, Q except A=-211(LC 6), L=-290(LC 7), N=-296(LC 9), S=-184(LC 8),
T=-163(LC 8), V=-171(LC 8), W=-138(LC 8), P=-191(LC 9), O=-171(LC 9), M=-122(LC 9)
Max Grav All reactions 250 lb or less at joint(s) N, R, S, T, V, W, Q, P, O, M except A=381(LC 8), L=549(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-491/281, B-C=-376/238, K-L=-351/200
BOT CHORD M-N=-211/386, L-M=-204/368
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) R, Q except (jt=lb)
A=211, L=290, N=296, S=184, T=163, V=171, W=138, P=191, O=171, M=122.
9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) L, M.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
HF2
Truss Type
GABLE
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:04 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-5LKsoL8UZnLqjo5vaotot3vdl3RYSvUlDV5Z5dzPHJr
Scale = 1:60.0
T1
T2
T3
B1
B2
ST2
ST2
ST1
ST2
ST3
A
B
C
D
E
F G H I
N M
L
K
J
3x4
3x4 3x4
3x4
6x8
3-10-5
3-10-5
11-9-13
7-11-8
9-1-15
9-1-15
10-7-7
1-5-8
11-9-13
1-2-7
11-0-29-6-1211-0-214.42 12
14.42 12
Plate Offsets (X,Y)-- [F:0-1-5,Edge], [H:0-1-5,Edge], [I:Edge,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.05
0.02
0.07
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
-0.00
(loc)
-
-
I
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 69 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 11-9-13.
(lb) - Max HorzA=407(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) M, J except A=-143(LC 6), I=-146(LC 8), L=-175(LC 8), N=-165(LC 8),
K=-136(LC 8)
Max Grav All reactions 250 lb or less at joint(s) I, L, M, N, K, J except A=373(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-499/226, B-C=-358/169
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) M, J except (jt=lb)
A=143, I=146, L=175, N=165, K=136.
9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) I, L, K, J.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
HF3
Truss Type
GABLE
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:05 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-ZXuF?g96K4ThKyf58WO1QHRoPTntBM4uS9q6d3zPHJq
Scale = 1:58.5
T1
T2
W1
B1
ST5ST5ST5ST5ST5
ST4
ST3
ST2
ST1
T3
B3B2
ST5 ST5 ST5 ST5 ST5 ST5 ST5 ST5
A
B
C
D
E
F G H I J K L M N O P Q R S T
AL AK AJ AI AH AG AF AE AD AC AB AA Z Y X W V U
3x4
3x4
5x6
5x6
5x6
34-3-11
34-3-11
8-0-11
8-0-11
34-3-11
26-3-0
9-8-314.42 12
Plate Offsets (X,Y)-- [F:0-1-5,Edge], [M:0-3-0,0-3-0], [AA:0-3-0,0-3-0], [AE:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.06
0.01
0.12
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
-0.00
(loc)
-
-
U
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 295 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt T-U, K-AD, J-AE, I-AF, H-AG, G-AH, E-AI,
L-AC, M-AB, N-AA, O-Z, P-Y, Q-X, R-W, S-V
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 34-3-11.
(lb) - Max HorzA=383(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) U, AD, AE, AF, AG, AH, AC, AB, AA, Z, Y, X, W, V except A=-176(LC
6), AI=-147(LC 8), AJ=-169(LC 8), AK=-170(LC 8), AL=-139(LC 8)
Max Grav All reactions 250 lb or less at joint(s) U, AD, AE, AF, AG, AH, AI, AJ, AK, AL, AC, AB, AA, Z, Y, X, W, V
except A=450(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-583/240, B-C=-468/195, C-D=-310/141
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Provide adequate drainage to prevent water ponding.
3) All plates are 1.5x4 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) U, AD, AE, AF, AG,
AH, AC, AB, AA, Z, Y, X, W, V except (jt=lb) A=176, AI=147, AJ=169, AK=170, AL=139.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
HF4
Truss Type
GABLE
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:07 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-Ww0?QMBNsijPaGpUFxRVViX7lHSTfFpBvTJDiyzPHJo
Scale = 1:50.2
T1
T2
T1
B1
ST4ST4ST3
ST2
ST1
B2
ST4 ST3
ST2
ST1
A
B
C
D
E F G H I
J
K
L
M
W V UT S R Q P O N
3x4
3x4 3x4
3x4
3x4
21-4-5
21-4-5
7-4-3
7-4-3
14-0-3
6-8-0
21-4-5
7-4-3
8-9-158-9-1514.42 12
Plate Offsets (X,Y)-- [E:0-1-5,Edge], [I:0-1-5,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.07
0.16
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.01
(loc)
-
-
M
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 143 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt G-R, F-S, H-Q
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 21-4-5.
(lb) - Max HorzA=-235(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) M, R, S, T, Q, P except A=-115(LC 6), V=-172(LC 8), W=-207(LC 8),
O=-175(LC 9), N=-207(LC 9)
Max Grav All reactions 250 lb or less at joint(s) A, M, R, S, T, V, Q, P, O except W=279(LC 15), N=279(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-337/213, L-M=-308/168
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) M, R, S, T, Q, P
except (jt=lb) A=115, V=172, W=207, O=175, N=207.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
HF5
Truss Type
GABLE
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:09 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-SJ8lr2CdOJ_7pZzsNMTza6cQR47H781UMnoKmqzPHJm
Scale = 1:108.7
W1
T2
T3 T4
B1
B3
ST3
ST3
ST3
ST2
ST1
ST3
ST4
ST5
ST6
T1
B2
A
B
C
D
E
F
G H
I J K L
M
X W VU
T
S
R
Q
P
O
N
2x4
4x6 3x10
3x4
3x4
5x6
5x6
4-5-11
4-5-11
19-10-3
15-4-8
12-3-8
12-3-8
18-11-8
6-8-0
19-10-3
0-10-11
4-9-519-6-99-3-119-6-914.42 12
14.42 12
Plate Offsets (X,Y)-- [D:0-3-0,0-3-0], [H:0-3-2,0-1-10], [L:0-6-6,0-1-2], [M:Edge,0-1-8], [Q:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.31
0.11
0.25
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
-0.05
(loc)
-
-
M
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 176 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt F-R, E-S, D-T, C-V, G-Q
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 19-10-3.
(lb) - Max HorzX=578(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) P except M=-1074(LC 8), U=-259(LC 6), R=-228(LC 8), S=-163(LC 8),
T=-202(LC 8), V=-124(LC 8), W=-240(LC 8), Q=-151(LC 6), O=-171(LC 8), N=-184(LC 6)
Max Grav All reactions 250 lb or less at joint(s) X, R, S, T, V, W, O except M=440(LC 6), U=687(LC 8), Q=489(LC
8), P=259(LC 17), N=474(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD C-D=-149/338, D-E=-206/496, E-F=-266/646, F-G=-349/847, G-H=-181/467, H-I=-234/586,
I-J=-234/586, J-K=-234/586, K-L=-234/586, L-M=-247/618
BOT CHORD W-X=-561/218, V-W=-561/218, U-V=-561/218, T-U=-902/359, S-T=-881/350, R-S=-880/350,
Q-R=-881/350, P-Q=-888/352, O-P=-892/354, N-O=-879/347, M-N=-935/367
WEBS G-Q=-467/177, K-N=-384/184
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Bearing at joint(s) M, P, O, N considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) P except (jt=lb)
M=1074, U=259, R=228, S=163, T=202, V=124, W=240, Q=151, O=171, N=184.
10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) M, R, S, T, Q, P, O, N.
11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
HF6
Truss Type
GABLE
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:11 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-OhFWGkEtwwEr2t7FUnVRfXhiDuqma3Gnq5HQrjzPHJk
Scale = 1:59.7
W2
T1
W1
T2
B1
B2
ST3
ST2
ST1
ST4
ST5
AB
C D E F G H I
QP O N
M
L
K
J
3x4
3x4
3x4
0-4-8
0-4-8
2-8-3
2-3-11
11-10-5
9-2-3
0-4-8
0-4-8
11-10-5
11-5-13
7-0-511-0-611-0-614.42 12
Plate Offsets (X,Y)-- [I:0-0-11,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.55
0.05
0.13
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
-0.01
(loc)
-
-
I
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 105 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: I-J.
WEBS 1 Row at midpt E-M, D-O
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 11-10-5.
(lb) - Max HorzQ=163(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) L, M, O, K, J except Q=-148(LC 6), P=-287(LC 8), I=-178(LC 8),
N=-110(LC 6)
Max Grav All reactions 250 lb or less at joint(s) Q, P, I, N, L, M, O, K, J
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) L, M, O, K, J except
(jt=lb) Q=148, P=287, I=178, N=110.
9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) I, L, M, K, J.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
HF7
Truss Type
GABLE
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:12 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-supuT4EVhEMig1iR2U0gClEszIA?JWWw3l1_N9zPHJj
Scale = 1:59.7
W2
T1
W1
T2
B1
B2
ST3
ST2
ST1
ST4
ST5
AB
C D E F G H I
QP O N
M
L
K
J
3x4
3x4
3x4
0-4-8
0-4-8
2-8-3
2-3-11
11-10-5
9-2-3
0-4-8
0-4-8
11-10-5
11-5-13
7-0-511-0-611-0-614.42 12
Plate Offsets (X,Y)-- [I:0-0-11,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.55
0.05
0.13
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
-0.01
(loc)
-
-
I
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 105 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: I-J.
WEBS 1 Row at midpt E-M, D-O
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 11-10-5.
(lb) - Max HorzQ=163(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) L, M, O, K, J except Q=-148(LC 6), P=-287(LC 8), I=-178(LC 8),
N=-110(LC 6)
Max Grav All reactions 250 lb or less at joint(s) Q, P, I, N, L, M, O, K, J
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) L, M, O, K, J except
(jt=lb) Q=148, P=287, I=178, N=110.
9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) I, L, M, K, J.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
HF8
Truss Type
GABLE
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:14 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-oGxeulGmDrcPwLrqAv38HAJK45rJnQJDW3W5S2zPHJh
Scale = 1:54.9
T1
T2
T1
B1
ST4ST4ST4ST4
ST3
ST2
ST1
B2
ST4 ST4 ST4
ST3
ST2
ST1
A
B
C
D
E F G H I J K L M
N
O
P
Q
AE AD AC AB AA Z Y X W V U T S R
3x4
3x4 3x4
3x4
3x4
28-9-5
28-9-5
8-0-3
8-0-3
20-9-3
12-9-0
28-9-5
8-0-3
9-7-99-7-914.42 12
Plate Offsets (X,Y)-- [E:0-1-5,Edge], [M:0-1-5,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.06
0.06
0.18
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.01
(loc)
-
-
Q
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 213 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt I-X, H-Z, G-AA, F-AB, J-W, K-V, L-U
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 28-9-5.
(lb) - Max HorzA=-257(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) Q, X, Z, AA, AB, W, V except A=-140(LC 6), AC=-149(LC 8),
AD=-167(LC 8), AE=-191(LC 8), T=-143(LC 9), S=-169(LC 9), R=-190(LC 9)
Max Grav All reactions 250 lb or less at joint(s) A, Q, X, Z, AA, AB, AC, AD, W, V, U, T, S except AE=256(LC 15),
R=255(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-344/237, P-Q=-298/165
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) Q, X, Z, AA, AB, W, V
except (jt=lb) A=140, AC=149, AD=167, AE=191, T=143, S=169, R=190.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
HF9
Truss Type
GABLE
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:15 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-HTV165HO_9kGXUQ0jcaNqNsVwVBsWudMljFe_UzPHJg
Scale: 1/4"=1'
W1
T1
T2
B1
ST2
ST1
ST3
A B
C
D
E
F
J I H G
3x4
2x4
6-10-11
6-10-11
0-4-0
0-4-0
6-10-11
6-6-11
7-5-127-10-914.42 12
Plate Offsets (X,Y)-- [B:Edge,0-3-1]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.06
0.04
0.11
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.00
(loc)
-
-
F
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 48 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 6-10-11.
(lb) - Max HorzJ=-302(LC 9)
Max Uplift All uplift 100 lb or less at joint(s) J except F=-128(LC 7), H=-177(LC 9), I=-137(LC 9), G=-144(LC 9)
Max Grav All reactions 250 lb or less at joint(s) J, H, I, G except F=334(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD D-E=-318/153, E-F=-447/195
BOT CHORD I-J=-126/302, H-I=-126/302, G-H=-126/302, F-G=-126/302
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) All plates are 1.5x4 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) J except (jt=lb) F=128,
H=177, I=137, G=144.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
HF10
Truss Type
GABLE
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:16 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-lf3PJRI0lTs79e?DHK5cMbOf?vXDFL1WzN?BWwzPHJf
Scale = 1:44.5
T1 W1
B1
ST1
ST2
A
B
C
D
G F E
2x4
1.5x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
5-11-11
5-11-11
7-2-214.42 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.10
0.03
0.10
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.00
(loc)
-
-
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 40 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-11-11 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 5-11-11.
(lb) - Max HorzA=270(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) A, E except G=-239(LC 8), F=-104(LC 8)
Max Grav All reactions 250 lb or less at joint(s) A, E, F except G=318(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-345/183
WEBS B-G=-278/263
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) A, E except (jt=lb)
G=239, F=104.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
J01
Truss Type
Jack-Open
Qty
6
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:17 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-DrdnWnIeVm__noaPr1crvoxnkJtl_prfC1kl2MzPHJe
Scale = 1:13.5
T1
B1
A
B
C
D2x4
1-5-3
1-5-3
-2-0-0
2-0-0
1-5-3
1-5-3
0-4-71-3-150-10-111-3-158.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.29
0.01
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.00
-0.00
-0.00
0.00
(loc)
B
B
C
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 8 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 1-5-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) C=-81/Mechanical, B=384/0-5-8 (min. 0-1-8), D=10/Mechanical
Max HorzB=87(LC 8)
Max UpliftC=-81(LC 1), B=-125(LC 8)
Max GravC=36(LC 12), B=384(LC 1), D=23(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) C except (jt=lb)
B=125.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
J02
Truss Type
Jack-Open
Qty
6
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:18 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-h2A9k7JGG46rOy9bPl74R0UxeiDCjG5pRhUIbpzPHJd
Scale = 1:20.0
T1
B1
A
B
C
D2x4
3-5-3
3-5-3
-2-0-0
2-0-0
3-5-3
3-5-3
0-4-72-7-152-2-112-7-158.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.35
0.06
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.01
-0.00
0.00
(loc)
B-D
B-D
C
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 14 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 3-5-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) C=61/Mechanical, B=419/0-5-8 (min. 0-1-8), D=22/Mechanical
Max HorzB=140(LC 8)
Max UpliftC=-53(LC 8), B=-97(LC 8)
Max GravC=67(LC 15), B=419(LC 1), D=53(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) C, B.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
J03
Truss Type
Jack-Open
Qty
34
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:19 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-9EkXxTKu1OEi06knySeJ_D06O6XfSjLygLDs7FzPHJc
Scale = 1:26.5
T1
B1
A
B
C
D2x4
5-5-8
5-5-8
-2-0-0
2-0-0
5-5-8
5-5-8
0-4-74-0-23-6-154-0-28.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.35
0.17
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.04
-0.06
-0.00
0.00
(loc)
B-D
B-D
C
B
l/defl
>999
>975
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 20 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 5-5-8 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) C=174/Mechanical, B=491/0-5-8 (min. 0-1-8), D=36/Mechanical
Max HorzB=196(LC 8)
Max UpliftC=-117(LC 8), B=-90(LC 8)
Max GravC=176(LC 15), B=491(LC 1), D=88(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B except (jt=lb)
C=117.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
J04
Truss Type
Jack-Open
Qty
4
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:20 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-dQIw9pLXohMZeGJ_W9AYWRZI_WvPBAb5u?zPfhzPHJb
Scale = 1:14.0
T1 B1
A
B
C
D2x4
1-7-3
1-7-3
-2-0-0
2-0-0
1-7-3
1-7-3
0-4-71-5-41-0-11-5-48.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.29
0.01
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.00
-0.00
-0.00
0.00
(loc)
B
B
C
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 8 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 1-7-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) C=-59/Mechanical, B=377/0-5-8 (min. 0-1-8), D=11/Mechanical
Max HorzB=92(LC 8)
Max UpliftC=-59(LC 1), B=-118(LC 8)
Max GravC=28(LC 12), B=377(LC 1), D=26(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) C except (jt=lb)
B=118.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
J05
Truss Type
Jack-Open
Qty
4
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:21 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-5csIM9L9Z?UQFPuA4thn3e6SuwDowdqF7fiyB8zPHJa
Scale = 1:20.6
T1
B1
A
B
C
D2x4
3-7-3
3-7-3
-2-0-0
2-0-0
3-7-3
3-7-3
0-4-72-9-42-4-12-9-48.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.35
0.07
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.01
-0.00
0.00
(loc)
B-D
B-D
C
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 14 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 3-7-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) C=71/Mechanical, B=424/0-5-8 (min. 0-1-8), D=23/Mechanical
Max HorzB=145(LC 8)
Max UpliftC=-59(LC 8), B=-96(LC 8)
Max GravC=77(LC 15), B=424(LC 1), D=56(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) C, B.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
J06
Truss Type
Jack-Open
Qty
6
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:22 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-ZpQgaUMnKJcHtZTMeaC0csedeKY9f34OMJSWkazPHJZ
Scale = 1:27.0
T1
B1
A
B
C
D2x4
5-7-8
5-7-8
-2-0-0
2-0-0
5-7-8
5-7-8
0-4-74-1-78.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.35
0.19
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.04
-0.07
-0.00
0.00
(loc)
B-D
B-D
C
B
l/defl
>999
>887
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 20 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 5-7-8 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) C=182/Mechanical, B=497/0-5-8 (min. 0-1-8), D=37/Mechanical
Max HorzB=200(LC 8)
Max UpliftC=-121(LC 8), B=-90(LC 8)
Max GravC=184(LC 15), B=497(LC 1), D=91(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B except (jt=lb)
C=121.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
J07GD
Truss Type
Jack-Closed Girder
Qty
2
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:23 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-2?_2nqNP5ck8Vj2ZBIjF83BsPjsuOP5YbzB3G0zPHJY
Scale: 1/2"=1'
T1 W1
B1
W3 W2
A
B
C
E D
F G
4x4
1.5x4
4x4
3x6
3x10
2-9-12
2-9-12
5-7-8
2-9-12
2-9-12
2-9-12
5-7-8
2-9-12
0-4-74-1-78.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.09
0.28
0.46
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.02
0.00
0.01
(loc)
E
A-E
D
E
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 32 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-7-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) A=986/0-5-8 (min. 0-1-8), D=899/Mechanical
Max HorzA=148(LC 25)
Max UpliftA=-157(LC 8), D=-242(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-1184/161
BOT CHORD A-F=-243/933, E-F=-243/933, E-G=-243/933, D-G=-243/933
WEBS B-E=-180/1049, B-D=-1134/296
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=157,
D=242.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 685 lb down and 142 lb up at 1-8-4,
and 685 lb down and 142 lb up at 3-8-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of
others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-C=-84, A-D=-14
Concentrated Loads (lb)
Vert: F=-685(F) G=-685(F)
Job
BOH - JAKE SOMMER
Truss
J08
Truss Type
Jack-Open
Qty
2
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:24 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-WBYQ?AO1swt?6tcll?EUhHk_37GJ7zahpdxcoSzPHJX
Scale = 1:14.3
T1 B1
A
B
C
D2x4
1-8-3
1-8-3
-2-0-0
2-0-0
1-8-3
1-8-3
0-4-71-5-151-0-111-5-158.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.29
0.01
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.00
-0.00
-0.00
0.00
(loc)
B
B
C
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 9 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 1-8-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) C=-44/Mechanical, B=371/0-3-0 (min. 0-1-8), D=12/Mechanical
Max HorzB=94(LC 8)
Max UpliftC=-44(LC 1), B=-114(LC 8)
Max GravC=23(LC 12), B=371(LC 1), D=28(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) C except (jt=lb)
B=114.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
J09
Truss Type
Jack-Open
Qty
3
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:25 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-_O5oCWOfdE?sk1BxJjljDUG9MXbbsQqq2GgAKvzPHJW
Scale = 1:20.9
T1
B1
A
B
C
D2x4
3-8-8
3-8-8
-2-0-0
2-0-0
3-8-8
3-8-8
0-4-72-10-22-4-152-10-28.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.32
0.08
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.01
-0.00
0.00
(loc)
B-D
B-D
C
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 15 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 3-8-8 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) C=90/Mechanical, B=416/0-3-0 (min. 0-1-8), D=25/Mechanical
Max HorzB=148(LC 8)
Max UpliftC=-66(LC 8), B=-92(LC 8)
Max GravC=94(LC 15), B=416(LC 1), D=60(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) C, B.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
J10
Truss Type
Jack-Open
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:26 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-SafBPsPHOX7iMBm8tQGymipLlxxqbt4_HwQjtLzPHJV
Scale = 1:16.8
T1
B1
A
B
C2x4
3-8-8
3-8-8
3-8-8
3-8-8
0-4-72-10-22-4-152-10-28.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.21
0.08
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.01
-0.00
0.00
(loc)
A-C
A-C
B
A
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 11 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 3-8-8 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) A=173/0-3-0 (min. 0-1-8), B=148/Mechanical, C=25/Mechanical
Max HorzA=101(LC 8)
Max UpliftA=-7(LC 8), B=-93(LC 8)
Max GravA=173(LC 1), B=148(LC 1), C=60(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) A, B.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
J11
Truss Type
Jack-Open
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:27 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-wmDZdCQw9rFZzLLKQ8oBJvMZ0LH_KKe7Va9HPnzPHJU
Scale = 1:16.8
T1 W1
B1
ST1
A
B
C
E D
2x4
1.5x4
1.5x4 1.5x4
1.5x4
3-8-8
3-8-8
0-4-72-10-28.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.05
0.02
0.04
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.00
(loc)
-
-
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-8-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) A=70/3-8-8 (min. 0-1-8), D=62/3-8-8 (min. 0-1-8), E=217/3-8-8 (min. 0-1-8)
Max HorzA=99(LC 8)
Max UpliftD=-27(LC 8), E=-96(LC 8)
Max GravA=71(LC 17), D=62(LC 1), E=217(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) Gable requires continuous bottom chord bearing.
4) Gable studs spaced at 2-0-0 oc.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) D, E.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
K01G
Truss Type
Common Supported Gable
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:28 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-OznxqYRYw9NQbUwW_rJQr7ufAkcC3naHkEvqxEzPHJT
Scale = 1:33.2
T1 T1
B1
ST3
ST2
ST1
ST2
ST1
A
B
C
D
E
F
G
H
IN M L K J
4x4
3x4 3x4
14-6-0
14-6-0
-2-0-0
2-0-0
7-3-0
7-3-0
14-6-0
7-3-0
16-6-0
2-0-0
0-4-75-2-70-4-78.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.28
0.08
0.06
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.04
-0.05
0.00
(loc)
I
I
H
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 71 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 14-6-0.
(lb) - Max HorzB=162(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) B, H, M, N, K, J
Max Grav All reactions 250 lb or less at joint(s) L, M, N, K, J except B=393(LC 1), H=393(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, H, M, N, K, J.
10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) B, H.
11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
K02
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:30 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-KLvhFDSoRmd8qo4v5GLuwY_voYCgXgGaCYOx06zPHJR
Scale = 1:32.8
T1
T2
B1
W1
A
B
C
D
E
4x6
4x6 4x6 1.5x4
7-3-0
7-3-0
14-6-0
7-3-0
-2-0-0
2-0-0
7-3-0
7-3-0
14-6-0
7-3-0
0-4-75-2-70-4-78.00 12
Plate Offsets (X,Y)-- [B:Edge,0-0-4], [D:0-0-0,0-0-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.65
0.47
0.12
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.12
-0.17
0.01
0.09
(loc)
D-E
D-E
D
D-E
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 53 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-3-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) D=672/0-5-8 (min. 0-1-8), B=898/0-5-8 (min. 0-1-8)
Max HorzB=151(LC 5)
Max UpliftD=-120(LC 9), B=-191(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-845/158, C-D=-837/146
BOT CHORD B-E=-50/548, D-E=-50/548
WEBS C-E=0/285
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) D=120,
B=191.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
K03
Truss Type
Roof Special
Qty
2
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:31 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-pYT4TZTQC4l?Syf5fzs7TlW2jyXoG7RjQC7UYZzPHJQ
Scale = 1:32.8
T1
T2
B1
W1
A
B
C
D
E
4x6
3x10 4x4 1.5x4
7-3-0
7-3-0
14-10-8
7-7-8
-2-0-0
2-0-0
7-3-0
7-3-0
14-10-8
7-7-8
0-4-75-2-70-1-78.00 12
Plate Offsets (X,Y)-- [B:0-0-15,Edge], [D:0-3-11,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.77
0.54
0.12
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.15
-0.22
0.01
0.11
(loc)
D-E
D-E
D
D-E
l/defl
>999
>781
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 54 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-1-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) D=699/Mechanical, B=924/0-5-8 (min. 0-1-8)
Max HorzB=151(LC 5)
Max UpliftD=-128(LC 9), B=-194(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-898/168, C-D=-880/149
BOT CHORD B-E=-54/593, D-E=-54/593
WEBS C-E=0/296
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) D=128,
B=194.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
M01GD
Truss Type
Half Hip Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:32 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-Hk1SgvU2zNts46EHDhNM0z3NoM?T?YQsfst24?zPHJP
Scale = 1:22.9
T1
T2
W1
B1
W1 W2 W1 W2
A
B
C D E
H G
F
I J
K L M
4x8
2x4 3x4 2x4
1.5x4
3x10
5x6
3-8-8
3-8-8
7-10-8
4-2-0
12-0-8
4-2-0
-2-0-0
2-0-0
3-8-8
3-8-8
7-10-8
4-2-0
12-0-8
4-2-0
0-4-72-10-28.00 12
Plate Offsets (X,Y)-- [C:0-6-4,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.17
0.06
0.20
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.02
0.00
0.01
(loc)
G
G-H
F
G
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 133 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size) F=735/0-5-8 (min. 0-1-8), B=915/0-3-0 (min. 0-1-8)
Max HorzB=150(LC 8)
Max UpliftF=-282(LC 5), B=-293(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-988/345, C-I=-811/315, D-I=-810/315, D-J=-811/316, E-J=-811/316, E-F=-649/263
BOT CHORD B-H=-305/736, H-K=-308/746, G-K=-308/746
WEBS D-G=-438/248, E-G=-353/911
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) F=282,
B=293.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 88 lb down and 66 lb up at 3-8-8, 96
lb down and 63 lb up at 5-9-4, and 96 lb down and 63 lb up at 7-9-4, and 96 lb down and 95 lb up at 9-9-4 on top chord, and 147 lb
down and 105 lb up at 3-8-8, 26 lb down at 5-9-4, 26 lb down at 7-9-4, and 26 lb down at 9-9-4, and 50 lb down and 37 lb up at
11-2-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-C=-84, C-E=-84, B-F=-14
Continued on page 2
Job
BOH - JAKE SOMMER
Truss
M01GD
Truss Type
Half Hip Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:32 2021 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-Hk1SgvU2zNts46EHDhNM0z3NoM?T?YQsfst24?zPHJP
LOAD CASE(S) Standard
Concentrated Loads (lb)
Vert: C=-6(B) H=-147(B) D=-6(B) G=-11(B) I=-6(B) J=-64(B) K=-11(B) L=-11(B) M=-50
Job
BOH - JAKE SOMMER
Truss
N01
Truss Type
Monopitch
Qty
2
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:33 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-lwaqtFVgkh?jhGoUnOvbYAbT0lH5k2p0uWcbdRzPHJO
Scale = 1:29.9
T1
W1
B1
A
B
C
D
1.5x4
1.5x4
2x4
6-1-8
6-1-8
-2-0-0
2-0-0
6-1-8
6-1-8
0-4-74-5-78.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.46
0.23
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.06
-0.10
0.00
0.00
(loc)
B-D
B-D
B
l/defl
>999
>670
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 27 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) D=252/0-5-8 (min. 0-1-8), B=507/0-3-0 (min. 0-1-8)
Max HorzB=211(LC 8)
Max UpliftD=-111(LC 8), B=-88(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B except (jt=lb)
D=111.
5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
P01
Truss Type
Roof Special
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:35 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-hJiaIxWxGIFRxZysupx3dbhtkZ?XCyUJLq5ihKzPHJM
Scale = 1:25.5
T1
T2
T1
B1
ST1
A B
C D E
F G
H
3x4 3x4
3x4 3x4
1.5x4
1.5x4
15-0-6
15-0-6
2-0-3
2-0-3
13-0-3
11-0-0
15-0-6
2-0-3
0-4-71-2-51-4-20-1-80-4-70-1-81-0-138.00 12
Plate Offsets (X,Y)-- [C:0-2-0,Edge], [E:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.19
0.10
0.05
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.00
0.00
0.00
(loc)
G
G
F
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 81 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size) B=373/13-6-8 (min. 0-1-8), F=373/13-6-8 (min. 0-1-8), H=662/13-6-8 (min. 0-1-8)
Max HorzB=29(LC 7)
Max UpliftB=-66(LC 5), F=-66(LC 4), H=-153(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-546/135, C-D=-464/113, D-E=-464/113, E-F=-546/134
BOT CHORD B-H=-111/462, F-H=-111/462
WEBS D-H=-553/212
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
5) Provide adequate drainage to prevent water ponding.
6) Gable requires continuous bottom chord bearing.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, F except (jt=lb)
H=153.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
P02
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:36 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-9VGzWHXZ1cNIYjX3SXSIApD?dzLNxO0SaUrFDmzPHJL
Scale = 1:19.9
T1
T2
W1
B1
ST1
A
B
C D E
G F
3x4 3x4
1.5x4 3x4 1.5x4
1.5x4
11-2-11
11-2-11
4-0-3
4-0-3
11-0-3
7-0-0
11-2-11
0-2-8
0-4-72-6-52-8-20-1-82-4-130-1-88.00 12
Plate Offsets (X,Y)-- [C:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.44
0.13
0.10
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
A
A
F
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 35 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=235/10-5-12 (min. 0-1-8), B=244/10-5-12 (min. 0-1-8), G=575/10-5-12 (min. 0-1-8)
Max HorzB=96(LC 8)
Max UpliftF=-65(LC 4), B=-40(LC 8), G=-129(LC 5)
Max GravF=246(LC 22), B=244(LC 1), G=575(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS D-G=-477/175
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) F, B except (jt=lb)
G=129.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
P03
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:37 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-diqLjdYBowV9At6F0EzXj0m94NhdgrNcp8apmCzPHJK
Scale = 1:19.7
T1
T2
W1
B1
ST1
A
B
C D E
G F
3x4 3x4
1.5x4 3x4 1.5x4
1.5x4
11-2-11
11-2-11
3-0-3
3-0-3
11-2-11
8-2-8
0-4-71-10-52-0-20-1-81-8-130-1-88.00 12
Plate Offsets (X,Y)-- [C:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.46
0.13
0.09
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
0.00
0.00
(loc)
A
A
F
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 33 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=243/10-5-12 (min. 0-1-8), B=253/10-5-12 (min. 0-1-8), G=557/10-5-12 (min. 0-1-8)
Max HorzB=69(LC 8)
Max UpliftF=-61(LC 4), B=-50(LC 8), G=-130(LC 5)
Max GravF=243(LC 22), B=253(LC 1), G=557(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS D-G=-465/177
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) F, B except (jt=lb)
G=130.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
P04
Truss Type
Roof Special
Qty
1
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:38 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-5uOjxzZpZDd?o1hRZxUmFEJIkm0jPIdl1oKMIfzPHJJ
Scale = 1:19.7
T1
T2
T3
W1
B1
ST1
A
B
C D
E
F
H G
3x4 3x4
4x4
1.5x4 3x4 1.5x4
1.5x4
11-2-11
11-2-11
1-11-11
1-11-11
10-6-11
8-7-0
11-2-11
0-8-0
0-4-71-2-01-9-20-1-81-7-100-1-81-0-88.00 12
Plate Offsets (X,Y)-- [C:0-2-0,Edge], [E:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.59
0.13
0.09
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
0.00
0.00
(loc)
A
A
G
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 32 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) G=200/10-5-12 (min. 0-1-8), B=281/10-5-12 (min. 0-1-8), H=572/10-5-12 (min. 0-1-8)
Max HorzB=59(LC 8)
Max UpliftG=-51(LC 8), B=-69(LC 8), H=-141(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS D-H=-474/182
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Provide adequate drainage to prevent water ponding.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) G, B except (jt=lb)
H=141.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
P05
Truss Type
Roof Special
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:39 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-a4y58IZRKXlsPBGd7f??oRrZ1ANV8mPuGS3vq5zPHJI
Scale = 1:26.4
T1
T2
T3
T4
T5
W1
B1
ST1
ST2
A B
C D
E
F G
H
K J I
3x4 4x6
4x6
2x4
2x4
3x4
1.5x4
1.5x4
1.5x4
6x8
14-10-3
14-10-3
2-7-11
2-7-11
11-4-11
8-9-0
12-3-11
0-11-0
13-6-11
1-3-0
14-10-3
1-3-8
0-4-71-7-52-2-102-4-70-1-81-4-100-1-82-1-28.00 12
Plate Offsets (X,Y)-- [C:0-2-0,Edge], [E:0-2-11,Edge], [F:0-3-5,Edge], [G:0-5-5,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.24
0.10
0.06
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.00
0.00
0.00
(loc)
A
A
I
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 94 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
T3: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.All bearings 14-1-4.
(lb) - Max HorzB=68(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) I, B, J except K=-186(LC 8)
Max Grav All reactions 250 lb or less at joint(s) I, J except B=327(LC 1), K=728(LC 21)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-267/65
WEBS D-K=-597/229
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
5) Provide adequate drainage to prevent water ponding.
6) Gable requires continuous bottom chord bearing.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) I, B, J except (jt=lb)
K=186.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
P06
Truss Type
Roof Special
Qty
4
Ply
1 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:40 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-2GWTLea35ruj1KrqhMXEKfOnuaj1tCX2V6pTMXzPHJH
Scale = 1:10.8
T1 W1
B1A
B
C
D
1.5x4
1.5x4 2x4
2-7-11
2-7-11
2-7-11
2-7-11
0-4-71-9-20-1-81-7-100-1-88.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.04
0.02
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
0.00
0.00
(loc)
A
A
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 8 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-7-11 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) D=80/1-10-12 (min. 0-1-8), B=132/1-10-12 (min. 0-1-8)
Max HorzB=59(LC 8)
Max UpliftD=-36(LC 8), B=-19(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) D, B.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
LOAD CASE(S) Standard
Job
BOH - JAKE SOMMER
Truss
R01GD
Truss Type
Roof Special Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:43 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-SrBc_gcyOmGIuoZPMV4xyH04_ndp4NUUB417zszPHJE
Scale = 1:68.2
T1
T2
W2
B1
W2 W3 W2 W3 W2
W5
W4
W1
B6
B8B7B4B5B5B4B2 B3
A
B C D E
R O L I
H
G
FJ
K
M
N
PS
Q
T
U
V W X Y Z AA AB AC AD AE
AF AG AHAI AJ AKALAM ANAO
6x8 1.5x4
10x12 MT20HS7x10 12x12 7x10
1.5x4
3x10
5x8
7x10
3x4
5x6
5x8 5x6
5x8
5x6 5x6
3x6
5x8
3-1-13
3-1-13
8-2-15
5-1-2
13-2-6
4-11-6
18-0-0
4-9-10
3-1-13
3-1-13
8-2-15
5-1-2
13-2-6
4-11-6
18-0-0
4-9-10
9-4-1311-6-02-0-08.00 12
Plate Offsets (X,Y)-- [B:0-4-0,0-1-9], [L:0-5-0,0-4-8], [O:0-3-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.94
0.52
0.82
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.08
-0.11
0.01
0.05
(loc)
H-I
H-I
H
H-I
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT20HS
Weight: 470 lb FT = 20%
GRIP
220/195
165/146
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std *Except*
W5,W1: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F
1.6E
W4: 2x6 DF 1800F 1.6E or 2x6 DF SS
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt E-H, B-O, D-G, A-R
JOINTS 1 Brace at Jt(s): G, J, K, N, Q
REACTIONS.(lb/size) H=5618/Mechanical, R=6415/Mechanical
Max HorzR=80(LC 8)
Max UpliftH=-1532(LC 5), R=-1676(LC 5)
Max GravH=5961(LC 2), R=6737(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-T=-2201/570, B-T=-1624/453, B-U=-2484/673, C-U=-2482/672, C-D=-2482/673,
F-H=-527/161, R-S=-6375/1607, A-S=-6123/1565
BOT CHORD O-W=-503/1831, W-X=-503/1831, X-Y=-503/1831, L-Y=-503/1831, L-Z=-588/2307,
Z-AA=-588/2307, AA-AB=-588/2307, I-AB=-588/2307, I-AC=-580/2283, AC-AD=-580/2283,
AD-AE=-580/2283, H-AE=-580/2283, F-G=-296/73, J-AF=-332/65, AF-AG=-332/65,
AG-AH=-332/65, G-AH=-332/65, K-AI=-355/73, AI-AJ=-355/73, AJ-AK=-355/73, J-AK=-355/73,
P-AM=-274/59, AM-AN=-274/59, N-AN=-274/59
WEBS O-P=-2078/491, B-P=-2560/688, B-N=-584/2214, L-N=-524/1862, C-M=-552/206,
K-L=-310/788, D-K=-388/1310, I-J=-788/3163, D-J=-720/3156, D-G=-5046/1332,
G-H=-4864/1241, A-Q=-1258/4797, O-Q=-1148/4403
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-3-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
4) Provide adequate drainage to prevent water ponding.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) H=1532,
R=1676.
Continued on page 2
Job
BOH - JAKE SOMMER
Truss
R01GD
Truss Type
Roof Special Girder
Qty
1
Ply
2 Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Mon Apr 19 15:15:43 2021 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:MdswrBQbWAlpQyQTof2ldAzQHPK-SrBc_gcyOmGIuoZPMV4xyH04_ndp4NUUB417zszPHJE
NOTES-
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 931 lb down and 264 lb up at 1-9-12, and 932 lb down and 286 lb up at
3-9-12 on top chord, and 946 lb down and 271 lb up at 1-9-12, 919 lb down and 318 lb up at 3-9-12, 919 lb down and 299 lb up at 5-9-12, 959 lb down and 298 lb up at
7-9-12, 954 lb down and 298 lb up at 9-9-12, 922 lb down and 270 lb up at 11-9-12, 965 lb down and 269 lb up at 13-9-12, and 968 lb down and 269 lb up at 14-11-12, and
968 lb down and 269 lb up at 16-2-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-B=-84, B-E=-84, H-R=-14, F-AH=-14, AH-AK=-14, AK-AL=-14, AL-AN=-14, Q-AN=-14, Q-S=-14
Concentrated Loads (lb)
Vert: T=-894(F) U=-894(F) V=-919(B) W=-919(B) X=-919(B) Y=-919(B) Z=-919(B) AB=-919(B) AC=-919(B) AD=-919(B) AE=-919(B)