HomeMy WebLinkAboutLOT LAYOUT - 21-00247 - 1133 Greenside Loop - New SFR.pdfR„
D,2 631
/
r
SVOQE
DSO'111 N \\ �/ '
CONCRETE
DRIVE \
\
\ 9
\
\
\
\
\
I '
/
/
/
,
/
I '
,
/
/
/
20'-0"
w SETBACK '
I
/
/
/
MAIN F.F.=100'-0"
11. 1
,
4
25�
/�ePG'h
/
/
,
/
/
,
/
v
v
V
GARAGE T.O.S.=98'-6" a
rI�s
o
0"
M �a
/
rn %
m
/ f/
/ a
�I
N / '
� f
/
/
/
U / f
N � ,
I '
co
to
f
26'-0" I 50.07' PROPEF TY LINE
24'-0 314"
NOTES:
1. DRIVEWAY SHALL BE GRADED SUCH THAT WATER DRAINING OFF THE DRIVE DOES NOT FLOW ONTO
THE ROAD AND IS DIVERTED INTO A ROADSIDE DITCH OR GUTTER.
2. MIN. DRIVEWAY FLARES TO BE 2'-0" AS REQ'D BY CODE.
3. HOUSE DRAINAGE FINAL GRADES TO BE MIN. 6" OF FALL FOR FIRST 10' FROM HOME.
4. LOT IS TO BE GRADED AND LANDSCAPED INA MANNER THAT WILL PREVENT WATER RUNOFF FROM
ADVERSELY AFFECTING ADJOINING PROPERTY LINES.
5. PROVIDE METALLIC WATER SERVICE & CONCRETE ENCASED ELECTRODE PER 2017 NEC.
6. ALL CONSTRUCTION TO COMPLY WI THE 2018 INTERNATIONAL BUILDING CODE.
7. STORM DRAINAGE TO FLOW TO APPROVED STORM DRAIN SYSTEM.
8. PROVIDE ROAD BASE RAMP TO PROTECT PAVED ROAD, CURB AND SIDEWALK AS REQUIRED.
9. PROVIDE 1"WATER LINE TO HOUSE.
10. DUST, MUD AND EROSION SHALL BE CONTROLLED BY WHATEVER MEANS NECESSARY, AND THE
ROADWAY SHALL BE KEPT FREE OF MUD AND DEBRIS AT ALL TIMES.
11. BUILDER/OWNER SHALL REPLACE ANY EXISTING SIDEWALK OR CURB & GUTTER ALONG THE
FRONTAGE OF THIS PROJECT THAT IS FOUND TO BE DEFECTIVE, AS DIRECTED BY THE CITY INSPECTOR.
12. SETBACKS ARE DETERMINED BY LOCAL ZONING ORDINANCES.
13. PROPERTY LINES AND SETBACKS VARY IN RELATIONSHIP TO THE STREET, SIDEWALK, ETC.
14. VERIFY WITH BUILDING DEPT. AND I OR SURVEYOR FOR ACCURATE PLACEMENT OF STRUCTURE.
15. SOME JURISDICTIONS REQUIRE MIN. DISTANCES BETWEEN ADJACENT STRUCTURES WHICH WILL
OVERRIDE A SETBACK. VERIFY WI LOCAL BUILDING I ZONING DEP.
16. VERIFY ALL HEIGHT RESTRICTIONS W/ LOCAL BUILDING 1 ZONING DEP.
CRAIG WALL
DESIGN
7707 SOUTH MAIN STREET
MIDVALE, UT 84047
801.285.8885
EACH SUB -CONTRACTOR SHALL
CHECK AND UNDERSTAND ALL
DIMENSIONS, NOTES AND OTHER
ASPECTS OF THIS PROJECT
APPLICABLE TO THEIR TRADE
AND AFFECTING OTHER TRADES
PRIOR TO AND DURING
CONSTRUCTION.
NOTIFY DESIGNER OR ENGINEER
IN WRITING OF ANY
DISCREPANCIES OR CHANGES
ON THE DRAWINGS BEFORE
PROCEEDING WITH ANY WORK.
EACH SUB -CONTRACTOR SHALL
COORDINATE WORK WITH OTHER
TRADE THROUGH THE GENERAL
CONTRACTOR.
THE DESIGNER WILL NOT
ASSUME RESPONSIBILITY FOR
ANY MISUSE OR MISREADING OF
THESE PLANS. WHERE
INFORMATION IS AVAILABLE BUT
UNCLEAR, THE PERSON USING
THESE PLANS IS RESPONSIBLE
FOR CLARIFYING ANY
QUESTIONS ACCORDING TO THE
CONDITIONS STATED ABOVE.
( revisions:
Project number
Date MARCH 26, 2021
Drawn by CVVD
Engineered by NIA
SITE PLAN
cl
no
W
(.)I(/)
Z
W
WT
C
Q <
Q
r._n
�./ /
�C'3
O
W
W
m��
CC
0D
�
COX
W0oocc
J
W
�
z
..
C7
Q_
�c/)
.0
L
Q.
( revisions:
Project number
Date MARCH 26, 2021
Drawn by CVVD
Engineered by NIA
SITE PLAN
cl